The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

Acoustic radiation characteristics of a tile projector with performance variations among unit transducers (단위 트랜스듀서 간 성능편차를 갖는 타일형 프로젝터의 음향방사 특성)

  • Chun, Wonjong;Noh, Eunghwy;Ohm, Won-Suk;Seo, Youngsoo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.436-444
    • /
    • 2016
  • Uniformity in transducer performance is a must-have to ensure the reliable acoustic performance of a tile projector, used for active echo reduction. However, practical limitations imposed by variations in material properties and fabrication errors lead to performance variations among unit transducers, which could degrade the radiation characteristics (transmitting voltage response and directivity) of the tile projector and ultimately the echo reduction performance. In this paper we present a method to minimize these adverse effects via an appropriate placement of unit transducers within the tile projector. To this end, we perform a series of coupled acoustic-piezoelectric simulations, assuming a group of 36 unit transducers having 6 dB variations in transmitting voltage response, to analyze and compare the radiation characteristics of tile projectors under different transducer placement schemes.

ART 에어로졸 재부유실험 데이터를 이용한 재부유모델의 평가

  • 박재우
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.790-797
    • /
    • 1997
  • 에어로졸 재부유현상은 중대사고 방사선원항 평가에서 그 중요성이 인식되고 있으나 거의 모든 사고해석 코드에서 다루어지지 않고 있다. 따라서 본 연구는 지금까지 제시된 몇가지 유형의 에어로졸 재부유모델을 ORNL에서 실시된 에어로졸 재부유실험 데이터를 이용하여 정확도와 중대사고 해석코드에 적용가능성을 분석하였다. 본 연구에서 고려한 모델은 시간의 멱승함수와 지수함수형으로 표시된 모델들이다. 본 연구에서 분석한 바에 의하면 두 유형에 속하는 대부분의 모델이 재부유량뿐만 아니라 재부유율을 계산하는 데서 실험데이터와 상당한 편차를 보여 현재의 형태로 중대사고 해석 코드에 접목하는 데는 문제가 있는 것으로 분석되었다. 그러나 보다 광범위한 실험데이터를 통한 보완이 이루어진다면 모델식 자체의 간편함으로 접목이 용이할 것이다.

  • PDF

The application of an improved algorithm for optimal reconfiguration of distribution systems (배전계통 재구성 최적화 알고리즘 개선 적용)

  • Jeong, Jong-Man;Park, Chang-Ho;Chae, Woo-Kyu;Jang, Su-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.272-274
    • /
    • 2006
  • 본 논문에서는 한국전력공사의 배전계통 운영계획시스템(Distribution Line PLANning system)에서 배전계통 재구성 최적화에 적용하고 있는 선로간의 부하 평준화 알고리즘에 대하여 연구하였다. 기존의 알고리즘은 계통 내 임의의 연계 개폐기 혹은 구분 개폐기를 조작한 후 방사상의 운전조건을 만족하면 선로별 부하를 계산한다. 그리고 최대부하 선로와 최소부하 선로간의 부하 편차를 구하고 직전의 최적해와 비교하여 최적의 해를 찾아내는 방법이다. 그러나 계통이 커질 경우 시험해야할 경우의 수가 많아져서 시간이 많이 소요되고 또한 수렴속도를 빠르게 하기위하여 반복횟수를 제한하기 때문에 절대적인 최적의 해를 보장하지 못하였다. 따라서 본 연구에서는 탐색시간을 만족시키면서 전수조사하는 정도의 부하 평준화 최적해를 찾아서 배전계통의 재구성을 최적화하는 알고리즘을 구현하고자 한다.

  • PDF

Effective Doses in the Radial Gamma Radiation Field near a Point Source: Gender Difference and Deviation from the Personal Dose Equivalent (점선원 감마선장에서 유효선량의 성별차 및 개연선량당량과의 차이)

  • Chang, Jai-Kwon;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.299-307
    • /
    • 1997
  • The individual dose equivalent, $H_p$, effective dose, E, and gender specific effective dose, $E^m$ and E$^f$, were evaluated using the male and female phantoms of MIRD type located in the radial gamma radiation field near a point source. The point sources were placed at the distances of 15, 40 and 100 cm in front of the body at different heights. Two radionuclides, $^{137}Cs$ and $^{131}I$, were selected for the illustrative examples. In terms of the gender specific effective doses, $E^f$ is higher than $E^m$ with a few exceptions, e.g. the case where the point source is at the height of reproductive organs, but the differences from the sex- averaged values are not significant enough to justify use of gender specific dose conversion factors for the radial gamma field. The ratios $H_p$/E were in the range of 1 to 3 depending on the source and dosimeter positions when the dosimeter is worn on the front surface of the torso covering from chest to lower abdomen, but varied from 0.34 to 6.5 in extreme cases. When it is assumed that the typical handling procedure of radioactive source material and the typical dosimeter position(on the chest) be respected, the dosimeters calibrated against the broad parallel field appear to provide estimates with acceptable errors for the effective dose of workers exposed to radial broad gamma field around a point source.

  • PDF

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF

Submentovertex cephalometrics in korean adults (한국 성인에서 이하 두정 방사선 계측사진 분석)

  • Nahm, Dong-Seok;Suhr, Chung-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.1-7
    • /
    • 2000
  • It is important that the orthodontist accurately assess the degree to which facial asymmetry contributes to a given malocclusion before treatment planning. P-A, submentovertex and verticosubmental view have been used in the assessment of facial asymmetry. Among them, submentovertex view is rarely used because it has low reproducibility and is short of normal data and proper analysis method. The purpose of this study was to develop a submentovertex cephalomentrics and obtain normal data in Korean adults. The subjects consisted of 40 normal adults (male : 22, female 18) without the experience of orthodontic treatment. We find the 2 angular and 9 linear measurements. Though submentovertex cephalomentrics has the limitation in comparing the absolute length between right and left, it is useful to examine the relationship of skeletal and dental midline, the shape and location of condyle head and the shape of mandibular body in submentovertex view Therefore, if we understand the limitation of submentovertex cephalomentrics and use lateral , P-A and submentovertex cephalomentrics together, we will measure the location and amount of skeletal disharmony more exactly.

  • PDF

A study on the impact of Professional burnout and job autonomy on turnover intention in radiologic technologists (방사선사의 업무소진과 업무자율성이 이직의사에 미치는 연구)

  • Hwang, Sang-Kyu;Jeong, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.267-275
    • /
    • 2011
  • The purpose of this study was to examine the impact of the professional burnout and job autonomy of radiologic technologists on their turnover intention in hospitals. The major findings of the study were as follows: As for the average and standard deviation of the radiologic technologists in professional burnout and job autonomy, they got a mean of 3.15 in overall professional burnout, which was above the average. They got 2.88 in job autonomy, which was below the average. And they got 3.30 in turnover intention, which indicated that they had a strong tendency to change jobs. Regarding the influential factors for turnover intention, emotional burnout, loss of interest and loss of enthusiasm were identified as the factors that exerted a significant influence on turnover intention. If the kind of environments that stimulate their professional enthusiasm and allow them to make a decision on radiographic examinations based on their own professional knowledge is created, their burnout will be minimized. And the development of programs geared toward bolstering their job autonomy is expected to weaken their turnover intention, to enhance the efficiency of the personnel administration of radiologic technologists and their qualifications, and ultimately to boost their status in hospital organizations.

Study on the Characteristics of Far Infrared Ray Drying for Rough Rice(I) (벼의 원적외선 건조특성에 관한 연구(I))

  • 김유호;조영길;조광환;이선호;김영민;한충수;이호필
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.355-361
    • /
    • 2002
  • 본 연구에서는 원적외선.열풍 복합건조특성을 구명하기 위하여 건조용량 150-500kg이고, 승강기, 상.하부스크류, 건조실, 템퍼링실, 송풍기 및 가열장치로 구성된 시뮬레이터를 제작하여 건조특성시험을 실시하였다. 그 결과를 요약하면 다음과 같다. 가. 열풍온도에 따른 곡온변화를 시험한 결과 열풍온도 45$^{\circ}C$일 때 곡온 32-33$^{\circ}C$를 유지하였으며, 48, 51$^{\circ}C$일 때는 곡온이 35$^{\circ}C$가 넘어서는 현상을 나타났다. 건조중 곡온이 35$^{\circ}C$를 넘어서게 되면 동할미 발생량이 많아지고 품질저하가 급격히 일어난다. 나. 템퍼링실의 온도편차가 2,5$^{\circ}C$ 정도로 고른 온도분포를 나타내었고, 버너 입구쪽과 템퍼링실 중앙지점에서 온도가 약간 높게 나타났으며, 원적외선방사체 표면온도분포는 열풍온도가 45$^{\circ}C$일 때 평균 17$0^{\circ}C$를 유지하였고, 48$^{\circ}C$, 51$^{\circ}C$일 때 각각 22$0^{\circ}C$, 23$0^{\circ}C$에서 유지하는 것으로 나타났다. 다. 원적외선방사체 길이방향으로 온도편차는 버너를 기준으로 해서 버너쪽에서 멀수록 온도가 높았고, 중간, 근거리 순으로 나타났다. 버너의 원거리쪽에서 온도가 높게 나타난 것은 원적외선방사체를 통과하는 열풍이 빠져나가도록 되어있는 열풍 유동관이 버너 원거리에 위치하고 있어 버너에 불꽃이 점화되면서 열풍이 방사체 끝쪽으로 일시 머물렀다가 배출되기 때문으로 판단된다. 라. 건조기의 송풍량을 요인으로 하여 건조속도와 건조에너지를 비교한 결과 송풍량이 30cmm일 때가 25cmm에서보다 약 33%의 건조속도가 증가되어 송풍량이 많을수록 건조속도가 빨라졌으나, 건조에너지는 1,391kcal/kg.water로 나타나 약 4.2%정도가 더 소요 되었다. 곡물순환속도를 요인으로 하여 비교 시험한 결과 곡물순환속도가 33kg/min일때가 26kg/min보다 약 25%의 건조속도가 증가되어 곡물의 순환속도가 빠를수록 건조속도가 빨라졌으며, 건조에너지도 1,334kcal/kg.water로 비슷하게 소요되었다. 마. 시험구와 대비구의 건감률은 시험구에서 1.08~1.36w.b./h로 나타나 대비구보다 약 9.9~18.3%가 높게 나타났고, 건조에너지는 10.2~14.6%가 절감되었다. 발아율은 열풍온도가 낮을수록 높게 나타났고 시험구가 대비구보다 발아율이 낮게 나타났으며, 동할률 증가량도 원적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.

  • PDF

Hydrogeochemical Characteristics, Occurrence, and Distribution of Natural Radioactive Materials (Uranium and Radon) in Groundwater of Gyeongnam and Gyeongbuk Provinces (경상남북도 지하수 중 자연방사성물질 우라늄과 라돈의 산출특징과 함량분포에 대한 수리지화학적 연구)

  • Cho, Byong Wook;Choo, Chang Oh;Yun, Uk;Lee, Byeong Dae;Hwang, Jae Hong;Kim, Moon Su
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.551-574
    • /
    • 2014
  • The occurrence, distribution, and hydrogeochemical characteristics of uranium and radon in groundwater within different lithologies in Gyeongnam and Gyeongbuk provinces were investigated. A total of 201 groundwater samples from sedimentary rocks taking a large portion of the geology and from igneous rocks taking a small portion of the geology were analyzed and examined using factor analysis. Their radionuclide levels were used to construct detailed concentration maps. The groundwater types, defined using a Piper diagram, are mainly Ca-$HCO_3$ with less Na-$HCO_3$. Among the samples, one site exceeds $30{\mu}g/L$ of uranium (i.e., the maximum contaminant level of the USEPA) and three sites exceed 4,000 pCi/L of radon (i.e., the alternative maximum contaminant level). No samples were found to exceed the 15 pCi/L level of gross alpha or the 5 pCi/L level of radium. The concentration of uranium ranges from 0.02 to $53.7{\mu}g/L$, with a mean of $1.56{\mu}g/L$, a median of $0.47{\mu}g/L$, and a standard deviation of $4.3{\mu}g/L$. The mean concentrations of uranium for the different geological units increase in the following order: Shindong Group, Granites, Hayang Group, Yucheon Group, and Tertiary sedimentary rocks. The concentration of radon ranges from 2 to 8,740 pCi/L, with an mean of 754 pCi/L, a median of 510 pCi/L, and a standard deviation of 907 pCi/L. The mean radon concentrations for the investigated geological units increase in the following order: Granites, Yucheon Group, Tertiary sedimentary rocks, Hayang Group and Shindong Group. According to the factor analysis for each geological unit, uranium and radon behave independently of each other with no specific correlation. However, radionuclides show close relationships with some components. Regional investigations of radionuclides throughout the country require an integrated approach that considers the main lithological units as well as administrative districts.