• Title/Summary/Keyword: 방사능측정기

Search Result 18, Processing Time 0.021 seconds

Comparison of Radioactivity Measurement with Radionuclide Calibrators in Nuclear Medicine Centers (의료용 방사능측정기의 측정 정확도 평가)

  • Son, Hye-Kyung;Kim, Ji-Hye;Lim, Chun-Il;Yang, Hyun-Kyu;Park, Ki-Jung;Oh, Heon-Jin;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.16-21
    • /
    • 2010
  • To acquire good image quality and to minimize unnecessary radiation dose to patients, it is important to ensure that the radiopharmaceutical administered is accurately measured. Quality control of radionuclide calibrators should be performed to achieve these goals. The purpose of this study is to support the quality control of radionuclide calibrators in nuclear medicine centers and to investigate the level of measurement accuracy of the radionuclide calibrators. 58 radionuclide calibrators from 45 nuclear medicine centers, 74 radionuclide calibrators from 58 nuclear medicine centers, and 60 radionuclide calibrators from 45 nuclear medicine centers were tested with I-131, Tc-99m and I-123, respectively. The results showed that 81% of calibrators for I-131, 61% of calibrators for Tc-99m and 67% of calibrators for I-123 were within ${\pm}5%$. 17% of calibrators for I-131, 20% of calibrators for Tc-99m and 15% of calibrators for I-123 had a deviation in the range 5%< $|{\Delta}|{\leq}10%$. 2% of calibrators for I-131, 19% of calibrators for Tc-99m and 18% of calibrators for I-123 had a deviation of $|{\Delta}|$ >10%. Follow-up measurements were performed on the calibrators whose error exceeded the ${\pm}10%$ limit. As a result, some of the calibrator showed an improvement and their deviation decreased below the ${\pm}10%$ limit. The results have shown that such comparisons are necessary to improve the accuracy of the measurement and to identify malfunctioning radionuclide calibrators.

Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements (방사능 측정기를 이용한 F-18 FDG 방사능의 비교)

  • Jin, Gye-Hwan;Kweon, Dae-Cheol;Oh, Ki-Baek;Park, Hoon-Hee;Kim, Jung-Yul;Park, Min-Soo;Park, Dae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.159-166
    • /
    • 2009
  • Obviously, the administration of the prescribed amount of activity to the patient requires proper operation of the dose calibrator, which shall be verified by implementing the required quality control on the instrument. This investigation examined the accuracy and precision of dose calibrator activity measurement of the radiopharmaceutical F-18 FDG. To investigate the status of the nuclear medicine centers in Korea for the performance of dose calibrators, 10 centers providing PET/CT system services in Korea were inspected in 2008. We measured accuracy and precision in 10 equipments in consideration of PET/CT model, installation area, and installation time. According to the results of comparative analysis of 10 dose calibrators used to measure radioactivity of F-18 FDG, accuracy was -5.00~4.50% and precision was 0.05~0.45%, satisfying the international standards, which are accuracy ${\pm}$10% and precision ${\pm}$5%. This study demonstrated that, for accurate measurements, no adjustment is necessary for a dose calibrator setting when measuring different dose calibrators of F-18 FDG activity prescriptions.

  • PDF

Quality Management of Radionuclide Activity Meter using Ge-68/Ga-68 Rod Sources (Ge-68/Ga-68 Rod Sources을 이용한 방사능측정기의 정도관리)

  • Jung, Seung Hwan;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.575-582
    • /
    • 2018
  • This article compared accuracy of 5 types of radionuclide activity meters that are being used in medical institutions and proposed the correction factor for each radionuclide activity meters type, using Ge-68/Ga-68 radiation sources for scanner setting, regular scanner correction, attenuation correction, and normalization. The calibration constant between baseline values and measured values by CRC-15R, CRC-15 PET, CRC-712M, CRC-15 Beta, and CRC-25PET was 0.99999(P<0.0001), which showed very high linearity. In the accuracy test, CRC-15R, CRC-15 PET, CRC-712M, CRC-15 Beta, and CRC-25PET model showed -3.232%, -1.342%, -2.815%, -2.913%, and -3.089% respectively.

Counting Strategies in Radioactivity Measurement for the Monitoring and Screening (방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략)

  • Seo, Kyung-Won
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • One of the important things in low level radioactivity measurement is determination of the optimized counting time. Counting strategy has to be established, in order to count the radioactivity of the sample by condition of optimized measurement. There were three kinds of counting strategies in this report ; about fixed time, about fixed count, to compared sample, background, and reference level. The best of them was satisfied rendition to give about condition of instrument and process, as an example, efficiency of detector, counter capacity, maximum and average background count rate of counter, reference level and limit of derision and detection, etc. Therefore, we can decide the optimized counting time in the screening and monitoring. And we can save the time for courting the sample of course the data of count will be counted by optimized accuracy finally, in rountine measurement of radioactivity these strategies will be used available.

  • PDF

Determination of Minimum Detectable Activity in Environmental Samples (환경방사능 측정에서의 검출한계치의 정량적 고찰 및 최소검출방사능 농도 계산)

  • Lee, Myung-Ho;Shin, Hyun-Sang;Hong, Kwang-Hee;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.171-184
    • /
    • 1999
  • In this paper, using statistical theory the basic concepts and the formulars of lower limit of detection were deasribed. Assuming that risks of 5% are acceptable (95% confidence level), lower limits of detection were calculated on the measuring apparatus for alpha, beta and gamma nuclides. Also, on the basis concepts of lower limit of detection, the MDA values were calculated for the radionuclides detected easily in the environment. These results make it possible to evaluate confidence limits on the radioanalytical results in the environmental sample.

  • PDF

Direction detection technique of radioactive contaminants based on rotating collimator (회전형 콜리메이터 기반 방사능 오염원의 방향탐지 기법)

  • Hwang, Young-Gwan;Song, Keun-Young;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1519-1527
    • /
    • 2020
  • AGeneral radiation measuring devices have been developed in the form of spatial dose rate detection devices that measure dose rates to radioactive contaminant and 2D or 3D imaging devices for radioactive contamination information. Each of these radiation detection techniques has advantages. The advantages of both detection devices are necessary to minimize personal injury and rapid decontamination in the area of a radioactive accident. In this paper, we proposed a technique that can measure the dose rate and direction information about the radioactive pollutant source in real time using a detection sensor, a rotating body, and a directional shield for radioactive pollutant detection. The rotational-based detection device is configured to check the dose rate and direction using the location information of the rotator and measurement value. We proposed a measurement technique for vertical and horizontal directions through multiple holes. It was confirmed that the measurement error for direction information was less than 1% when detected in the horizontal direction.

Determination of % Contents of Uranium and Thorium in Natural Radioactive Ores by ${\gamma}$-ray Spectrometry (${\gamma}$-선 분광법을 이용한 한국산 방사성 원광내의 Uranium Thorium 함유량 측정)

  • 조성원;정문규;유건중;홍치유
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.273-278
    • /
    • 1970
  • The Contents of uranium and thorium in radioactive ores produced in Korea were determined by gamma-ray spectrometry utilizing Ge (Li) diode detector. Both methods, namely, gamma-ray spectrometries of activated samples and non-activated samples, were tested and compared for their accuracies and rapidness in determination of contents. Also the useful-ness of application of Ge(Li) diode detector to the determination of uranium and thorium contents in ores was discussed in detail.

  • PDF

A Study on the Counter Program of the Radiation Detector Using 8051 Micro-controller (8051 마이크로 콘트롤러를 이용한 휴대용 방사능 측정기의 카운터 프로그램 연구)

  • Kim, Yong-Duk;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.228-236
    • /
    • 1997
  • Radioactive materials need to control, measure and protect precisely the overflow because they are dangerous. In this paper, GM-counter type radiation detector system, that can precisely measure the quantity of radioactivity using improved counting program is designed and program that can store and transfer the counted data is studied. The manufactured system, counting system of GM-counter type radiation detector, and counter program can be utilized to measure them at various methods in an atomic power plant and research centers.

  • PDF

성토다짐의 밀도 및 수분 측정에 관한 연구

  • 김기준
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.38-46
    • /
    • 2002
  • 본 연구에서는 성토 다짐용 밀도 및 수분의 측정을 위하여 중성자 검출기는 2개 이상 그리고 감마선 검출기는 5개 이상 사용하여 함을 알 수 있었고, 또한 방사능 대비 방사선 방출수가 다른 선원에 비하여 우수한 Co-60 감마선원과 Cf-252 중성자 선원을 본 계기에 이용하는 것이 정밀도를 향상시키기 위하여 유리하다는 것을 알 수 있었다. 본 연구에서 설계하고 제작한 성토 다짐용관리용 밀도 및 수분 함량 측정기는 국내의 도로 공사 현장에서 성토의 다짐관리를 위하여 이용될 수 있을것으로 사료된다.

  • PDF