• Title/Summary/Keyword: 방사(放飼)

Search Result 17,175, Processing Time 0.045 seconds

Coupled Hydro-Mechanical Modelling of Fault Reactivation Induced by Water Injection: DECOVALEX-2019 TASK B (Benchmark Model Test) (유체 주입에 의한 단층 재활성 해석기법 개발: 국제공동연구 DECOVALEX-2019 Task B(Benchmark Model Test))

  • Park, Jung-Wook;Kim, Taehyun;Park, Eui-Seob;Lee, Changsoo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.670-691
    • /
    • 2018
  • This study presents the research results of the BMT(Benchmark Model Test) simulations of the DECOVALEX-2019 project Task B. Task B named 'Fault slip modelling' is aiming at developing a numerical method to predict fault reactivation and the coupled hydro-mechanical behavior of fault. BMT scenario simulations of Task B were conducted to improve each numerical model of participating group by demonstrating the feasibility of reproducing the fault behavior induced by water injection. The BMT simulations consist of seven different conditions depending on injection pressure, fault properties and the hydro-mechanical coupling relations. TOUGH-FLAC simulator was used to reproduce the coupled hydro-mechanical process of fault slip. A coupling module to update the changes in hydrological properties and geometric features of the numerical mesh in the present study. We made modifications to the numerical model developed in Task B Step 1 to consider the changes in compressibility, Permeability and geometric features with hydraulic aperture of fault due to mechanical deformation. The effects of the storativity and transmissivity of the fault on the hydro-mechanical behavior such as the pressure distribution, injection rate, displacement and stress of the fault were examined, and the results of the previous step 1 simulation were updated using the modified numerical model. The simulation results indicate that the developed model can provide a reasonable prediction of the hydro-mechanical behavior related to fault reactivation. The numerical model will be enhanced by continuing interaction and collaboration with other research teams of DECOVALEX-2019 Task B and validated using the field experiment data in a further study.

Site Competition of Ca2+ and Cs+ Ions in the Framework of Zeolite Y (Si/Al = 1.56) and Their Crystallographic Studies (제올라이트 Y (Si/Al = 1.56) 골격 내의 Ca2+과 Cs+ 이온의 자리 경쟁 및 그들의 결정학적 연구)

  • Kim, Hu Sik;Park, Jong Sam;Lim, Woo Taik
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.235-248
    • /
    • 2018
  • The present work was performed in order to study the effect of competing cation of $Ca^{2+}$ ion on ion exchange of $Cs^+$ on zeolite Y (Si/Al = 1.56). Three single-crystals of fully dehydrated and partially $Cs^+$-exchanged zeolites Y (Si/Al = 1.56) were prepared by the flow method using mixed ion-exchange solutions. The $CsNO_3:Ca(NO_3)_2$ molar ratios of the ion exchange solution were 1 : 1 (crystal 1), 1 : 100 (crystal 2), and 1 : 250 (crystal 3) with a total concentration of 0.05 M. The single-crystals were then vacuum dehydrated at 723 K and $1{\times}10^{-4}Pa$ for 2 days. The structures of the crystals were determined by single-crystal synchrotron X-ray diffraction technique in the cubic space group $Fd{\bar{3}}m$, at 100(1) K. The unit-cell formulas of crystals 1, 2, and 3 were ${\mid}Cs_{21}Ca_{27}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$, ${\mid}Cs_2Ca_{36.5}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$, and ${\mid}Cs_1Ca_{37}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$, respectively. In all three crystals, the $Ca^{2+}$ ions preferred to occupy site I in the D6Rs, with the remainder occupying sites I', II', and II. On the other hand, the significant differences in the fractional distribution of $Cs^+$ ions are observed depending on the intial $Cs^+$ concentrations in given ion exchange solution. In Crystal 1, $Cs^+$ ion are located at sites II', II, III, and III', and in crystal 2, at sites II, IIIa, and IIIb. In crystal 3, $Cs^+$ ions are only located at sites IIIa and IIIb. The degree of $Cs^+$ ion exchange decreased sharply from 28.0 to 2.7 to 1.3 % as the initial $Ca^{2+}$ concentration increases and the $Cs^+$ content decreases.

Mass-rearing Techniques of Anastatus orientalis (Hymenoptera: Eupelmidae), as the Egg-parasitoid of Lycorma delicatula (Hemiptera: Fulgoridae): An Using Method of Antheraea pernyi (Lepidoptera: Saturniidae) and L. delicatula Eggs in Laboratory (꽃매미 알 기생천적인 꽃매미벼룩좀벌의 대량사육기술: 산누에나방과 꽃매미 알 활용 방법)

  • Seo, Meeja;Kim, Jeong Hwan;Seo, Bo Yoon;Park, Changgyu;Choi, Byeong Ryeol;Kim, Kwang Ho;Ji, Chang Woo;Cho, Jum Rae
    • Korean journal of applied entomology
    • /
    • v.57 no.4
    • /
    • pp.243-251
    • /
    • 2018
  • Eggs, immature eggs, and pupae of 8 different insects (Halyomopha halys, Riptortus pedestris, Lymantria dispar, Antheraea yamamai, Verlarifictorus spp, Antheraea pernyi, and Musca domestica) including Lycorma delicatura were used to select the alternative host for laboratory mass rearing of A. orientalis. Except L. delicatula's eggs and immature eggs of A. pernyi, other 7 tested insects were not parasitized by A. orientalis. A. pernyi was reared with oak tree leaves and its cocoons were harvested on mid-July and early October. On 4 or 5 days after emergence, only female adults showing swollen abdomen were collected and stored at $1{\sim}5^{\circ}C$. We could get 150~200 eggs per one female by dissecting the female's abdomen. For examining the possibility for laboratory mass rearing of A. orientalis with A. pernyi's immature eggs, developmental periods from egg to pupa between the two different hosts were compared. Developmental periods were 36.1 days on immature eggs of A. pernyi and 36.8 days on an original host's eggs, respectively. The number of parasitized eggs by A. orientalis' female for 24 h was 3.4 on immature eggs of A. pernyi and 4.2 on an original host's eggs, respectively. However, there were no significant statistical differences in developmental period and parasitization between the two hosts. By supplying honeyed water to newly emerged female parasitoids, it was able to maximize their longevities up to 64.3 days after emergence. Therefore, our results support potential for laboratory mass-rearing of A. orientalis using A. pernyi's immature eggs as an alternative host.

A Study on Reduction of Radiation Exposure by Nuclear Medicine Radiation Workers (핵의학 방사선 작업종사자 피폭 감소 방안에 대한 연구)

  • Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.271-281
    • /
    • 2019
  • This study investigated the shielding efficiency of various types of shielding materials and measured the dose by organ using the phantom. Results of Shielding Efficiency Measurement Using Personal Radiation Meter. Among the various shielding materials, 1.1 mm RNS-TX composed of nano tungsten showed the highest shielding efficiency and 0.2 mm lead shielding showed the lowest shielding efficiency. 99mTc 30 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 20.53 mSv without radiation protective clothing, 8.75 mSv when wearing 0.25 mm Pb protective clothing, 6.03 mSv when wearing 0.5 mm Pb protective clothing. 131I 2 mCi mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 7.71 mSv without radiation protective clothing, 4.88 mSv when wearing 0.25 mm Pb protective clothing, 2.79 mSv when wearing 0.5 mm Pb protective clothing. 18F 5 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 16.39 mSv without radiation protective clothing, 15.84 mSv when wearing 0.25 mm Pb protective clothing, 12.52 mSv when wearing 0.5 mm Pb protective clothing. None of the radiation workers working in the nuclear medicine department exceeded the dose limit. However, when compared with other workers in the hospital, they showed a relatively high dose. Therefore, it is necessary to prepare measures to reduce and manage the dose of radiation workers in the nuclear medicine department through the wearing of radiation protective clothing made of lightweight, shielding material with good shielding efficiency, circulation task, task sharing, and substitution equipment such as auto dispenser.

Notes on the Status and Conservation of Callipogon Relictus Semenov in Korea (장수하늘소 현황 및 보전방안)

  • An, Seung Lak
    • Korean Journal of Heritage: History & Science
    • /
    • v.43 no.1
    • /
    • pp.260-279
    • /
    • 2010
  • The analysis on bibliography and field investigation of Callipogon relictus Semenov, 1898 (Korean natural monument number 218) shows that the size varies from country to country, and Korean specimens, for which male is 85~120mm and female is 65~85mm, are found to be the largest. The average diameter and length of egg are 2.60mm and 6.72mm respectively. The larva has milky color and is about 100~150mm in length. The pupa is nearly 70~110mm. An adult generally appears from June to September in Korea in the broadleaf forest of lowland, whereas it appears from June to July in China. It is known that the pupa largely feed on the old tree trunk of Carpinus laxiflora (Siebold & Zucc.) blume in Korea, but no such data have been reported in China and Russia, showing differences in host plants. While the larva period is not exactly known in Korea, it is reported to be two years in China. It appears that the species inhabits in very limited regions of approximately between geographical latitude $37.5^{\circ}{\sim}47.8^{\circ}$ and longitude $126^{\circ}{\sim}140^{\circ}$ including Korea, China and Russia. To conserve the long-horned beetle in Korea, this research drew out following some conclusions through analyzing the references and field survey data. First, it need to perform precise survey on the natural environment of occurring and collected area or place including host plant kinds, temperate, humidity, latitude, longitude etc. Second, habitat region must be designated as a restricted development area, and it need to exclude or reduce the damage factors to prosper reproduction of the species. Third, it is necessary to keep loosing cautiously artificial breeding individuals in the reported sites, not disturbing scope of natural populations. Fourth, it needs to educate or publicize many people importance and value of this species through many methods.

A Scientific Study of Roof Tiles in Joseon Dynasty from Dongdaemoon Stadium (동대문운동장유적 출토 조선시대 기와의 특성 연구)

  • Chung, Kwang-Yong
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.3
    • /
    • pp.160-173
    • /
    • 2012
  • Roofing tile research conducted in Korea so far is mostly related to studies on roofing tile patterns excavation report on the roof tile klin site in the aspects of archeology architecture and history of art. There have been continuous studies on kiln ground and manufacture techniques of roofing tiles. However it is difficult to find roofing tiles research based on scientific experiments. The research on this paper performs physical and chemical experimental study to understand order, manufacturing techniques and other characteristics of Chosun Dynasty roofing tiles excavated in Dongdaemun stadium. As for physical experimental study water absorption, specific gravity, whole-rock Magnetic susceptibility rate and Differential Thermal Analysis are conducted. As for chemical experimental study, neutron activation analysis(NAA), microstructure observation, X-ray diffractometry(XRD) analysis are conducted. Result of neutron activation analysis and statistical analysis on piece of roof tile 22 samples clearly show that the roofing tile samples are from different time line and places. It also shows different composition when compare average value of rare earth resources per findspots. It means roofing tiles were manufactured from clay mineral from several places. Close inspection using XRD and polarization microscope reveals that main components of roofing tiles are quartz and felspar. Mica and Illite are found partially. XRD analysis shows mullite mineral composition which occurs when roofing tile is calcined around $1000^{\circ}C$. Differential thermal analysis shows gradual exothermic peak near $900^{\circ}C$. Based on these results, it is assumed that roofing tile is made at $900{\sim}1000^{\circ}C$. result of XRD analysis shows mullite were made near $1000^{\circ}C$. in Differential Thermal Analysis shows gradual exothermic peak near $900^{\circ}C$. this results shows that roof tiles were made near 900~1000 near $1000^{\circ}C$ mean value of whole-rock Magnetic susceptibility rate. When performed comparative analysis using whole-rock Magnetic susceptibility rate average value, findspots provided no certain classification to arrange. Nonetheless low whole-rock Magnetic susceptibility rate 0.2~0.78(${\times}103$ SI unit) is found when roofing tile patterns are Pasangmun, Taesangmun, Eosangmun, Kyukjamun, Heongsunmun. Overall absorptivity is 14~21%. It is similar to 14~18% of roofing tile from Chosun Dynasty. There is only 1.4~2.5g/cm3 of roof tile sample specific gravity. The analysis finds no difference in specific gravity by findspots.

Conservation of Removing Surface Contaminants on Silla monument at Jungsung-ri using Nd:YAG Laser Cleaning System (Nd/YAG레이저를 이용한 포항중성리신라비 표면오염물 제거와 보존처리)

  • Lee, Tae Jong;Kim, Sa Dug;Lee, Joo Wan;Oh, Jung Hyeon;Lee, Myeong Seong
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.4
    • /
    • pp.142-153
    • /
    • 2011
  • 'Silla Monument Stone in Jungseong-ri, Pohang' was discovered in Pohang City, Gyeongsangbuk Province of Korea in 2009. The monument stone with irregular shape has dimensions of maximum height of 105cm, width of 47.6~49.6cm, thickness of 13.8~14.7cm and weight of 115kg. The results of monument stone was found to be granitite. Conservation treatment procedure was carried out in the order of production of Weathering map, cleaning of surface pollutants, consolidation using ethyl silicate. Black pollutant(crust) that covered more than 60% of the surface was analyzed first in order to remove the pollutants on the surface of the monumental stone by cleaning of surface pollutants using laser. The purpose on analysis was not only to verify the pollutants on the stone but also to carry out preliminary cleaning by securing rocks with same pollutant as the monumental stone. As the results of analysis using p-XRF(PMI. INNOV-X, USA) on the site, high level of Mn and Fe were detected, and the analysis of small section that had been fallen off with SEM/EDX for the purpose of quantitative analysis also detected high level of Mn. The Similar contaminants on Stone secured in the manner described above were made into 10 samples ($5cm{\times}5cm$) and was subjected to preliminary cleaning by Nd-YAG Laser(Laser&Physics, Korea). The results of surface observation through portable microscope during cleaning revealed that the power of 460mJ, wavelength of 1064nm and irradiation frequency of 1,800~2,300 per $25cm^2$ were most effective. Evaluation on the preservative treatment was made through confirmation of the extent of removal through color-difference meter measurement and component analysis prior to and following removal of the pollutants. As the result of color-difference meter measurement increase in the brightness was evidenced by the increase in the brightness ($L^*$)value from 33 to 49, and it was possible to ascertain the reduction in the pollutants as the content of Mn was reduced by about 80% from $50,000{\pm}5,000ppm$ to $10,000{\pm}2,000pmm$ from the result of component analysis.

Temporal-Spatial Location of Dwelling Site in Asan Bay in the Neolithic Age (아산만지역(牙山灣地域) 신석기시대(新石器時代) 집자리의 시공적(時空的) 위치(位置))

  • Koo, Ja Jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.3
    • /
    • pp.26-47
    • /
    • 2009
  • This study examined dwelling site from among the sites of the Neolithic age found in the Asan Bay(牙山灣) area, and the temporal-spatial location and meaning of the dwelling site (settlement). The majority of the settlements in the area are of a square style but some coexist with rectangular-style settlements, which is noteworthy. The dwelling sites of the Neolithic age found in Asan Bay area are mostly located in a ridge of hilly areas, divided into gentle, low areas (20~50 meters above sea level) and relatively high areas (50~80 meters above the sea level). Although location strongly corresponded to the residents' subsistence and the technical levels within the culture, it likely was greatly affected by natural environment where they lived, as well. In examining radiocarbon dating results and the excavated artifacts, the settlements found in Asan Bay were determined to belong to the period II(3,500~3,000 B.C.) stated in the Relative Chronological table of Dwelling sites in the Neolithic age, written by the author. Said Dwelling sites are proven to have a close relationship with those found on the coast of Gyeonggi Province(京畿道) and in the Geum River(錦江) valley. This is deemed to be the result of expansion and interchange between Gyeonggi Province(京畿道) group and Geum River(錦江) valley group, who constituted the large settlements. Additionally, the Daecheon-ri type dwelling sites in the Geum River valley were verified to be the result of exchange, and spread to the Asan Bay area in the same era. Two forms of Dwelling sites coexisted dynamically in the Asan Bay area around 3,500 B.C. Such a phenomenon resulted primarily from the expansion of the dwelling site due to the introduction of primitive agriculture, as well as environmental (temperature), biological and social changes at those times.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

A Study on the Correlation between Lung Ventilation Scan using Technegas and Pulmonary Function Test in Patients with COPD (Technegas를 이용한 폐환기 검사와 폐기능 검사의 상관관계에 관한 고찰)

  • Kim, Sang-Gyu;Kim, Jin-Gu;Baek, Song-EE;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.45-49
    • /
    • 2019
  • Purpose Lung Ventilation Scan(LVS) images directly inhaled radiation gas to evaluate lung ventilation ability. Therefore, it is influenced by various factors related to inhalation, including number of breaths, respiratory duration, respiration rate, and breathing method. In actual LVS examinations, it is difficult for objectify the patient's ability to inhale, and there is currently no known index related to inhalation. Therefore, this study confirms the correlation between counts per second(cps) in LVS and the results of pulmonary function test(PFT) and evaluate its usefulness as an objective indicator of inhalation. Materials and Methods From October 2010 to September 2018, 36 Chronic Obstructive Pulmonary Disease(COPD) patients who had both LVS and PFT were classified by severity(Mild, Moderate, Severe). LVS was performed by creating Technegas with Vita Medical's Technegas Generator and inhaling it to the patient. LVS images were acquired with Philips's Forte equipment., and PFT used Carefusion's Vmax Encore 22. The correlation between the cps measured by setting the region of interest(ROI) of both lungs on the LVS and the forced vital capacity(FVC), forced expiratory volume in one second($FEV_1$), $FEV_1/FVC$ of the results of PFT was compared and analyzed. Results We analyzed the correlation between cps of LVS using Technegas and the results of PFT by classifying COPD patients according to severity. Correlation coefficient between $FEV_1/FVC$ and cps was Severe -0.773, Moderate -0.750, and Mild -0.437. The Severe and Modulate result values were statistically significant(P<0.05) and Mild was not significant(P=0.155). On the other hand, the correlation coefficient between FVC and cps was statistically significant only in Mild and it was 0.882(P<0.05). Conclusion According to the study, we were able to analyze correlation between cps of LVS using Technegas and the results of PFT in COPD Patients. Using this result, when performing a LVS, the results of PFT can be used as an index of inhaling capacity. In addition, it is thought that it will be more effective for the operation of the exam rooms.