• Title/Summary/Keyword: 방법론 평가

Search Result 3,687, Processing Time 0.046 seconds

Comparison of the Awareness of Garden Functions (정원 기능에 대한 인식 비교)

  • Park, Mi-Ok;Choi, Ja-Ho;Koo, Bon-Hak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.2
    • /
    • pp.34-44
    • /
    • 2020
  • The purpose of this study was to investigate the difference in perceptions between gardens and park functions as recognized by two groups, Group A and Group B, in order to confirm the distinction between concepts and functions and then establish the importance of individual functions. The AHP was used to analyze the importance of each group's perceptions by dividing them into garden and park, Group A and non-Group A, respectively. In Group A, the importance of garden functions were considered in descending order of importance to be cultural function, ecological function, and social function. In the general group, ecological function, cultural function, and social function also appeared, but in a different order of importance. As for the park functions, Group A recognized the importance of functions in a similar order of importance to the gardens: cultural function, ecological function, and social function. Group B thought that social function, ecological function, and cultural function have the same significance. At the major classification level, Group A and Group B emphasized the social function of the parks. Group A recognized the importance of the garden's cultural function as the most important, whereas the general group emphasized the importance of the garden's ecological function. As for the mid-class level, Group A recognized the aesthetic beauty, health, ecological environment protection, and water circulation as important functions of the garden. For Group B, the ecological environment protection, aesthetic beauty, water cycle, and health were important. The concepts and functions of gardens and parks are still largely mixed but are gradually becoming differentiated. As a follow-up study, it is important to systematically manage the functions of gardens by establishing design, construction, and monitoring DB techniques for the garden type and examine the hierarchy of various other gardens.

Procedural Changes of Zhuzi(朱子)'s Theory of ZhongHe(中和) and the Theory of Jing(敬) (주자(朱子)의 중화설(中和說) 변천과정과 '경(敬)'공부론(工夫論))

  • Seo, Geun-Sik
    • (The)Study of the Eastern Classic
    • /
    • no.48
    • /
    • pp.225-252
    • /
    • 2012
  • In this paper, the writer examined the procedural changes of Zhuzi(朱子)'s theory of ZhongHe(中和), and also investigated the evaluations thereof made by the later generations. In the stage of ZhongHeJiuShuo(中和舊說), Zhuzi(朱子) ignored the theory of Lidong(李?), which was traditional theory argued by DaoNam School(道南學派). He met Zhangshi(張?) of HuXiang School(湖湘學派) and followed the school's philosophy, 'XianChaShiHouHanYang(先察識後涵養)', meaning what you should do first prior to making great efforts in self-cultivation is to examine the past, when desiring to know yourself. Even though Zhuzi(朱子) had learned the method of moral cultivation from Lidong(李?), he was fascinated by such method of moral cultivation as 'XianChaShiHouHanYang(先察識後涵養)' advocated by HuXiang School(湖湘學派) through discussion with Zhangshi(張?). This tells that he only recognized the fact that there were no achievements WeiFa(未發), but only the achievements YiFa(已發). In the stage of ZhongHeXinShuo(中和新說), he realized the mistakes committed in the time of ZhongHeJiuShuo(中和舊說), and put emphasis upon the achievements in the time WeiFa(未發). Zhuzi(朱子) had explained the relationships among mind, nature, and emotional bond as by his theory, 'XinTongXingQing(心統性情)', meaning that mind controls humans' original nature. Also he followed self-cultivation of Respect, no longer believing the Huhong(胡宏)'s XianChaShiHouHanYang(先察識後涵養). Such a method of self-cultivation means that his method of moral cultivation centered on the achievements YiFa(已發), which was originated from HuXiang School(湖湘學派), had been changed into the method of moral cultivation with a focus on the achievements WeiFa(未發), which was theory argued by DaoNam School(道南學派). However, Zhuzi(朱子)'s theory of ZhongHe(中和) that had seemed perfect began to be discussed and polished again during Joseon Period through the debates between Ligu(栗谷) and Niuxi(牛溪) in the 16th century, and through the debates between Youan(尤庵) and Yuxuan(寓軒) in the 17th century, also through the HuLuoLunZheng(湖洛論爭) represented by Nantang(南塘) and Weiyan(巍巖). Since Zhuzi(朱子)'s theory of ZhongHe(中和) had some flaws, it had to put through such debates as mentioned above. Those debates were generated because imperfections were found in the theory of ZhongHe(中和) by Zhuzi(朱子).

Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output (일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가)

  • Lee, Sang Hyeon;Ahn, Woo Sang;Lee, Woo Seok;Choi, Jin Hyeok;Kim, Seon Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose: Machine Performance Check (MPC) is a self-checking software based on the Electronic Portal Imaging Device (EPID) to measure daily beam outputs without external installation. The purpose of this study is to verify the usefulness of MPC by comparing and correlating daily beam output of QA Beamchecker PLUS. Materials and Methods: Linear accelerator (Truebeam 2.5) was used to measure 10 energies which are composed of photon beams(6, 10, 15 MV and 6, 10 MV-FFF) and electron beams(6, 9, 12, 16 and 20 MeV). A total of 80 cycles of data was obtained by measuring beam output measurement before treatment over five months period. The Pearson correlation coefficient was used to evaluate the consistency of the beam output between the MPC and the QA Beamchecker PLUS. In this study, if the Pearson correlation coefficient is; (1) 0.8 or higher, the correlation is very strong (2) between 0.6 and 0.79, the correlation is strong (3) between 0.4 and 0.59, the correlation is moderate (4) between 0.2 and 0.39, the correlation is weak (5) lower than 0.2, the correlation is very weak. Results: Output variations observed between MPC and QA Beamchecker PLUS were within 2 % for photons and electrons. The beam outputs variations of MPC were $0.29{\pm}0.26%$ and $0.30{\pm}0.26%$ for photon and electron beams, respectively. QA Beamchecker PLUS beam outputs were $0.31{\pm}0.24%$ and $0.33{\pm}0.24%$ for photon and electron beams, respectively. The Pearson correlation coefficient between MPC and QA Beamchecker PLUS indicated that photon beams were very strong at 15 MV, and strong at 6 MV, 10 MV, 6 MV-FFF and 10 MV-FFF. For electron beams, the Pearson correlation coefficient were strong at 16 MeV and 20 MeV, moderate at 9 MeV and 12 MeV, and very weak at 6 MeV. Conclusion: MPC showed significantly strong correlation with QA Beamchecker PLUS when testing with photon beams and high-energy electron beams in the evaluation of daily beam output, but the correlation when testing with low-energy electron beams (6 MeV) appeared to be low. However, MPC and QA Beamchecker PLUS are considered to be suitable for checking daily beam output, as they performed within 2 % of beam output consistency during the observation. MPC which can perform faster than the conventional daily beam output measurement tool, is considered to be an effective method for users.

  • PDF

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

Pulse wave velocity and ankle brachial index in adolescents with essential hypertension (본태성 고혈압 청소년에서 pulse wave velocity와 ankle brachial index에 대한 연구)

  • Joo, Sun Young;Cho, Ki Young;Cho, Su Jin;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.7
    • /
    • pp.769-776
    • /
    • 2006
  • Purpose : Pulse wave velocity(PWV) and ankle brachial index(ABI) are not only noninvasive methods used to assess arterial stiffness in adults, but also useful, simple ways to estimate the severity of hypertension, end stage renal disease and atherosclerosis in adults. But there are few studies on PWV and ABI in adolescents and children. In this study, hypertensive adolescents were compared to normal individuals to find out the usefulness of PWV as the index of progress in the disease. Methods : 413 teenagers were divided into three groups. The first group consisted of adolescents that only had hypertension(Group 1 : 23 teenagers). The second group consisted of the adolescents who had hypertension with obesity(Group 2 : 17 teenagers), and the last group was the normal subjects(Group 3 : 328 teenagers). Weight, height and body mass index were measured. Simultaneous measurements of systolic, diastolic and average blood pressure were obtained from the four extremities. PWV, ABI, ejection time and preejection period were also measured. Results : Right brachial-ankle PWV was significantly higher in both group 1 and group 2 compared with group 3, and significantly higher in group 2 compared with group 1. Likewise, left brachial-ankle PWV also showed significantly higher values in both group 1 and group 2 compared with group 3, and also higher values in group 2 compared with group 1. Positive correlations were found between the systolic, diastolic, average blood pressure and PWV. There were also positive correlations between the blood pressure and weight, body mass index. Conclusion : Higher PWV was demonstrated in adolescents with essential hypertension compared to normal subjects. Follow-up study is needed to evaluate the progress.

The immunogenicity and reactogenicity of Td booster vaccination in Korean preadolescents, aged with 11-12 years old (국내 11-12세 소아에서 Td 백신 추가접종의 면역원성과 안전성 평가)

  • Lee, Soo Young;Kwak, Ga Young;Mok, Hye Rin;Kim, Jong Hyun;Hur, Jae Kyun;Lee, Kyung Il;Park, Joon Su;Ma, Sang Hyuk;Kim, Hwang Min;Kang, Jin Han
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1185-1190
    • /
    • 2008
  • Purpose : This study was undertaken to evaluate the immunogenicity and reactogenicity of Td booster immunization in early preadolescents of Korea. Methods : Healthy preadolescents, who had been vaccinated with 4 or 5 doses of DTaP vaccines until 6 years old age, were enrolled in this study from August 2006 to April 2007. Diphtheria and tetanus anti-toxoid antibodies in sera were measured by ELISA just before vaccination and 4 weeks after vaccination to evaluate immunogenicity. Local and systemic adverse reactions observed for 4 weeks after vaccination to access reactogenicity. Results : 183 preadolescents were enrolled and mean age was $11.40{\pm}0.51$ years old. All subjects achieved seroprotective diphtheria and tetanus anti-toxoid antibodies (titers ${\geq}0.1IU/mL$) after Td booster vaccination. Among 183 vaccinees, 73.8% showed local adverse reactions and 37.2% systemic adverse reactions. Pain at injection site (66.1%) was the most common local reaction, and the most commonly shown systemic reaction was myalgia (17.5%). The adverse reactions were spontaneously relieved within three days after vaccination. Conclusion : Td vaccine in this study was high immunogenic and showed an acceptable tolerance in Korean preadolescents. Td booster vaccination at 11-12 years old is the most effective method to increase compliance of the vaccination and to decrease the incidence of diphtheria and tetanus.

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

The evaluation of lens absorbed dose according to the Optimold for whole brain radiation therapy (전뇌 방사선치료 시 Optimold에 따른 수정체의 흡수선량 평가)

  • Yang, Yong Mo;Park, Byoung Suk;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.77-81
    • /
    • 2014
  • Purpose : In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. Materials and Methods : In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made ??up to 5mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. Results : When there was the Optimold mask in the eyeball part, it was measured at $10.2cGy{\pm}1.5$ in the simulation therapy, and at $24.8cGy{\pm}2.7$ in the treatment, and when the Optimold mask was removed in the eye part, it was measured at $12.9cGy{\pm}2.2$ in the simulation therapy, and at $17.6cGy{\pm}1.5$ in the treatment. Conclusion : In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3 cGy in the simulation therapy and was reduced approximately 7 cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause cataracts and side effects was considered to be reduced due to decrease of the absorbed dose to the eye lens which had the high sensitivity on the radiation.

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.

Evaluating Global Container Ports' Performance Considering the Port Calls' Attractiveness (기항 매력도를 고려한 세계 컨테이너 항만의 성과 평가)

  • Park, Byungin
    • Journal of Korea Port Economic Association
    • /
    • v.38 no.3
    • /
    • pp.105-131
    • /
    • 2022
  • Even after the improvement in 2019, UNCTAD's Liner Shipping Connectivity Index (LSCI), which evaluates the performance of the global container port market, has limited use. In particular, since the liner shipping connectivity index evaluates the performance based only on the distance of the relationship, the performance index combining the port attractiveness of calling would be more efficient. This study used the modified Huff model, the hub-authority algorithm and the eigenvector centrality of social network analysis, and correlation analysis for 2007, 2017, and 2019 data of Ocean-Commerce, Japan. The findings are as follows: Firstly, the port attractiveness of calling and the overall performance of the port did not always match. However, according to the analysis of the attractiveness of a port calling, Busan remained within the top 10. Still, the attractiveness among other Korean ports improved slowly from the low level during the study period. Secondly, Global container ports are generally specialized for long-term specialized inbound and outbound ports by the route and grow while maintaining professionalism throughout the entire period. The Korean ports continue to change roles from analysis period to period. Lastly, the volume of cargo by period and the extended port connectivity index (EPCI) presented in this study showed a correlation from 0.77 to 0.85. Even though the Atlantic data is excluded from the analysis and the ship's operable capacity is used instead of the port throughput volume, it shows a high correlation. The study result would help evaluate and analyze global ports. According to the study, Korean ports need a long-term strategy to improve performance while maintaining professionalism. In order to maintain and develop the port's desirable role, it is necessary to utilize cooperation and partnerships with the complimentary port and attract shipping companies' services calling to the complementary port. Although this study carried out a complex analysis using a lot of data and methodologies for an extended period, it is necessary to conduct a study covering ports around the world, a long-term panel analysis, and a scientific parameter estimation study of the attractiveness analysis.