• Title/Summary/Keyword: 방류수 수질기준

Search Result 115, Processing Time 0.027 seconds

Performance Evaluation of WWTP Based on Reliability Concept (신뢰성에 기초한 하수처리장 운전효율 평가)

  • Lee, Doo-Jin;Sun, Sang-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.348-356
    • /
    • 2007
  • Statistical and probabilistic method was used in the analysis of data, which is the most effective one in describing the various natures, and the methodology relating the results with the design was developed. Influents and effluents of three treatment plants were analyzed and the focus was made on BOD, COD, SS, IN, TP The fluctuations of influent such as BOD, COD, SS were extremely large and their standard deviations(st.dev) were more than 10 mg/L. but those of TN, TP were small; the st.dev was 6.6 mg/L for TN, 0.6 mg/L for TP, respectively. But, effluent concentration showed consistent pattern regardless of the influent fluctuations, the st.dev was ranged between 0.28 and 4.48 mg/L. Effluent distributional characteristics were as follows; BOD, COD were distributed normally, but SS, TN, and TP, log-normally; unsymmetric and skewed to the right. The coefficient of reliability(COR) based on the results of statistics of data was introduced to evaluate the process performance an4 to reflect the process performance to the process design. The coefficient of reliability relates the design value(the goal) with the standards and it can be used in operating treatment facilities under a certain reliability level and/or in evaluating the reliability of the treatment facilities on operation. Each treated water quality of effluent showed the half of water quality standards in the level of 50% percentile and all treatment plant was achieved 100% probability of water quality standards. It was concluded that the variability of the process performance should be reflected to the design procedure and the standards through the analysis based on the statistics and the probability.

Water Quality Impact Assessment in Korea - Comparing with the Integrated Control of Pollutant-Discharging Facilities - (수질분야 환경영향평가의 개선방안 - 환경오염시설의 통합관리와 대비하여 -)

  • Lee, Jong Ho;Cho, Jae Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.5
    • /
    • pp.331-343
    • /
    • 2017
  • The important changes in water environment management in Korea can be summarized as the enactment of Act on the Integrated Control of Pollutant-Discharging Facilities. Therefore water quality impact assessment should be reexamined and be revised. This study examines the present water quality impact assessment items (permissible discharge limits, standards for effluent water quality including Total Pollutant Load Management System) and considers the land use regulation for water quality conservation and NVZs(Nitrate Vulnerable Zones of EU and England). It also considers lately adopted standards(maximum discharge standards, permissible discharge standards, and marginal discharge standards etc) based on Act on the Integrated Control of Pollutant-Discharging Facilities and then compares Korean BAT and its counterpart control technology of U.S.A. And it also compares the items of water quality impact assessment with those of Integrated Control of Pollutant-Discharging Facilities, based on EIS reporting items. This study suggests five improvement measures for water quality impact assessment. First reflection of discharge impact analysis on impact prediction and assessment, second reflection of permissible discharge standards on agreed standards in the EIA procedure, third, reflection of diversified BAT on mitigation measures in the EIA procedure, forth introduction of land use regulation such as NVZs, finally strengthening linkage between water quality items and land use items etc.

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus by Improved Sewage Treatment Process in Constructed Wetland by Natural Purification Method (자연정화공법에 의한 인공습지 하수처리장에서 하수처리 공정개선에 따른 질소 및 인의 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Woo-Young;Lim, Jong-Sir;Park, Chan-Hoon;Lee, Hong-Jae;Kim, Hong-Chul;Lee, Sang-Won;Lee, Do-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • To effectively treat the domestic sewage that was produced on a small-scale in farming and fishing village in order to encourage an ecologically friendly environment, a small-scale sewage treatment apparatus using natural purification methods that consisted of an aerobic and an anaerobic plots were constructed. The efficiency of sewage treatment according to the sewage loading was investigated to obtain the optimum sewage loading in small-scale sewage treatment apparatus. Removal rate of pollutants according to the sewage loading were in the order of $150\;Lm^{-2}day^{-1}{\fallingdotseq}300\;Lm^{-2}day^{-1}>600\;Lm^{-2}day^{-1}$. Therefore, the optimum sewage loading was 300 L m-2 day-1. Under the optimum sewage loading, removal rate of BOD, $COD_{Mn}$, turbidity, T-N and T-P were 99, 94, 99, 49 and 89%, respectively. However, to satisfy the water quality standard in effluent in small-sclae sewage treatment apparatus for domestic sewage treatment, the low removal efficiency of T-N and T-P must be improved. So to improve the removal rate of T-N and T-P, the efficiency of sewage treatment according to the improved sewage treatment process such as, re-treatment at aerobic plot, anaerobic condition of aerobic plot, changing the filter media sizes and the depths in anaerobic plot, and also addition of oyster shells to filter media at anaerobic plot were investigated. In case of 150 cm depth in anaerobic plot with filter medium A (effectivity particle size 1.50 mm) and addition of oyster shells to filter media at anaerobic plot, removal rate of T-N and T-P in both plots were increased by 10 and 3%, and 14 and 7% in comparison with 100 cm depth in anaerobic plot with filter medium B(effectivity particle size 0.95 mm), respectively. The optimum improved sewage treatment process in small-scale sewage treatment apparatus were 150 cm depth in anaerobic plot with filter medium A and addition of oyster shells to filter media at anaerobic plot.

Advanced Swine Wastewater Treatment with using Membrane Bioreator(A/O) and Nanofiltration (MBR(Membrane Bioreactor: A/O)공정과 나노여과를 이용한 축산폐수 고도처리)

  • 장경국;배태현;김은영;장하원;탁태문
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.115-118
    • /
    • 2004
  • 축산폐수에 대한 방류수 수질기준 항목에 COD의 추가 및 질소와 인의 기준이 강화(1999년)됨에 따라 많은 축산폐수처리시설의 보강과 새로운 기술도입이 요구되고 있다. 따라서 대부분의 공공처리시설에서는 질소 및 인을 제거하기 위하여 2차 처리단계에서 무산소조(탈질조)와 호기성(포기조)를 연계한 생물학적 질소제거를 실시하고, 최종처리단계에서 응집제 투입에 의한 응집ㆍ침전공정후 모래여과 또는 활성탄 흡착공정에 의한 인과 색도제거 하는 등, 생물학적 처리 및 물리ㆍ 화학적 처리시설이 추가적으로 보완ㆍ적용단계에 있다.(중략)

  • PDF

A Study on Reuse of Reclaimed Water in Jeonbuk Province (전북지역 하수처리수 재이용 방안 연구)

  • Cho, Changwoo;Kim, Jintae;Park, Jeongjae;Song, Juhoon;Lee, Miseon;Jeong, Juri;Ryou, Jaewoong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.237-245
    • /
    • 2017
  • This study was aimed at investigating effluent water quality and proposing reuse possibilities for 12 sewage treatment plants discharged more than $5,000m^3/day$ in order to recycle the sewage treatment plant effluent of Jeollabuk-do effectively. Additionally, a laboratory scale test for reprocessing water discharge was performed. Categories of reclaimed sewage water reuse were divided into 7 topics and analyzed a total of 28 items including 16 heavy metals based on water quality standard. As a results, color, BOD, TN, chloride and Electrical Conductivity (EC) exceeded reused water quality standard. In particular, color and TN exceeded in 8 and 5 sewage treatment plants, respectively. The value of chloride and EC were high in sewage treatment plants including the food and industrial wastewater. At 4 sewage treatment plants were possible to reuse without re-treatment. The laboratory scale test was conducted to SandFilter (SF)-Granular Activated Carbon (GAC)-MicroFiltraion (MF)-Reverse Osmosis (RO). Both the removal efficiencies and economic feasibility of total E. coli., color and Suspended Solid (SS) suited in case using the SF-GAC treatment method. The removal of chloride and EC had little effect in the case of SF-GAC-MF system, but RO showed over 90% of removal efficiency. After using SF-GAC process only, the concentration of $UV_{254}$ decreased sharply from 0.3651 /cm to 0.0306 /cm and it showed over 92% of removal efficiency rate. In conclusion, for the effective reuse of sewage discharged water, water quality and the surrounding terrain of treatment plants should be all taken into account. If it needed for the reprocessing, both the selection for treatment and economic combination treatment methods will have to be considered.

Guidelines and Optimum Treatment for Agriculture Reuse of Reclaimed Water (농업적 용수재이용 수질기준을 고려한 적정 하수재처리에 관한 연구)

  • Jung, Kwang-Wook;Jeon, Ji-Hong;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.356-368
    • /
    • 2003
  • Water quality of effluent from wastewater treatment plants (WWTPS) was reviewed to examine the feasibility of agricultural reuse using USEPA and WHO guidelines. It might meet the guidelines for BOD and SS, however, the most critical microbiological concentration was too high and further treatment is required. The pilot study of three treatments were performed to reduce microbiological concentrations. The UV irradiation was proved to be very effective in disinfection of secondary level effluent, and about 30 mW ${\cdot}$ s/$cm^2$ of dose was suggested to meet the even most stringent USEPA guidelines. Slow sand filter demonstrated effective removal of bacteria, and effluent concentration of total coliform (TC), fecal coliform (FC), and E. coli. dropped from about 10,000/100 mL to 300, 200, and 150 MPN/100 mL, respectively, showing over 95% removal. These level of bacterial concentration sufficiently meet the WHO guidelines ($10^3\;{\sim}\;10^5$ FC/100 mL), and could meet the more stringent USEPA guidelines (200 FC/100 mL) if properly applied. Slow sand filter also provided about 50% removal of SS, turbidity, and BOD in addition to bacterial removal. The removal efficiency of pond system was relatively poor, but still showed over 85% removal and effluent concentration of TC, FC, and E. coli was all below 10,000/100 mL. The pond system alone could meet the WHO guidelines, but hardly meet the USEPA guidelines and further treatment might be necessary. Overall, three methods evaluated in the study treat the effluent to meet the WHO microbiological guidelines for agricultural reuse. The UV disinfection and slow sand filter might also could the USEPA guidelines, while the pond system can hardly meet the USEPA guidelines if applied alone. The WHO and USEPA guidelines were made based on data from upland field agricultural system and may not be directly applicable to the paddy field agricultural system. Therefore, national standards for agricultural reuse of reclaimed water should be made considering domestic agricultural systems as well as international guidelines. Also, further investigation is recommended to develop optimum and feasible treatment measures for agricultural reuse of effluent from WWTPs.

Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling (모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구)

  • Lee, Hyunseop;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.251-256
    • /
    • 2019
  • In the upstream and nearby areas of the water source, there are many areas where the sewerage penetration rate is relatively low due to development restrictions. This has been continuously affecting the pollution of the water source. As a measure to prevent this, method of distributing sewage and improving existing facilities are suggested. In this study, A MWTP(Municipal Watewater Treatment Plant) using the Air-vent SBR process located at upstream of An-dong and Im-ha Dam was selected as a modeling facility. And, the retrofit method to improve the effluent from RCSTP(Rural Community Sewage Tratment Plant) was induced based on A MWTP modeling result. The model construction and verification were carried out based on the operating data for 5 years (2012 ~ 2016). As a result, it was analyzed that the water quality of the effluent during the winter could be improved through control of cycle time in Air-vent SBR process and decreasing SRT (BOD: 1.8%, COD: 54.5%, SS: 4.3%, T-N; 0.8% and T-P: 7.7%). This research suggests that result of this research can be utilized as a retrofit method to improve the effluent overall treatment efficiency of the MWTP and the RCSTP which have similar operation process.

Analysis on Nitrogen Faction of Influent Sewage in Domestic STP Based on Long-term Incubation Method (장기 배양법을 이용한 국내 하수처리장 유입 하수의 질소 성상 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.2
    • /
    • pp.216-222
    • /
    • 2017
  • Recently, opinions on the need for revision regarding the nitrogen effluent standard of nitrogen from sewage treatment plant(STP) are consistently suggested. However, it is axiomatic that if nitrogen effluent standard is strengthened without a clear basis, it will cause confusion in domestic STP. In this research, nitrogen fraction was analyzed based on a long-term incubation method, according to STP capacity, and the linked treatment of industrial wastewater. As a result, NBDDON, which is difficult to treat in STP, ranged from 1.0 to 1.9 mg/L. larger DON and NBDDON/DON was detected in small STP (under 10,000 m3 /d) as opposed to the large STP. NBDDON/DON in industrial STP was about 0.7 and it was higher than municipal STP. This research result will be used in the important raw data for revision of nitrogen effluent standard of nitrogen from STP.

Study on indirect reuse of reclaimed wastewater for agriculture (하수처리수의 농업용수 간접재이용에 관한 연구)

  • Jeong, Han-Seok;Seong, Choung-Hyun;Jang, Tae-Il;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.436-436
    • /
    • 2012
  • 하수처리수의 농업용수 재이용에는 직접재이용과 간접재이용이 있으며 대부분의 경우 간접재이용의 형식으로 하수처리수가 농업용수로 이용되고 있다. 전국 130여개의 하수처리장 방류수가 논을 포함한 인근 농경지의 관개용수에 영향을 미치고 있으나 적절한 처리과정 없이 농업용수로 사용되고 있으며, 이는 농민과 농산물 그리고 소비자에게 보건 위생적 영향을 미칠 수 있다. 따라서 하수처리수를 안전하게 농업용수로 간접재이용할 수 있는 연구가 수반되어야 한다. 본 연구에서는 하수처리수의 농업용수 간접재이용에 따른 작물생육, 수질, 토양 환경영향 및 인체위해성 평가 등을 포함한 기초연구를 3년간 진행할 계획이다. 또한 본 연구를 통해서 간접재 이용지구의 유형을 구분하고 이에 따른 저비용, 고효율의 수처리 공정을 개발하며, 간접재이용을 위한 적정 수질기준을 정립하고자 한다.

  • PDF

Characteristics of Water Quality Change of Urban River according to Installation of Interceptors and Wastewater Treatment Plant (차집관로와 하수처리시설의 설치에 따른 도시하천의 수질변화 특성)

  • Zhou, Juan Juan;Lim, Bong Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.813-820
    • /
    • 2014
  • In this study, the characteristics of water quality change of the three streams in Daejeon were analyzed according to the expanded installation of interceptors and wastewater treatment plant (WTP). Gabcheon 5 (Singu Bridge) location showed the maximum difference of the highest and lowest concentrations in the last decade. However, the recent water quality of this location was worse than other locations, because of the impact of the effluent from the WTP. In the upstream of the WTP, the Daejeon stream was relatively better than the other locations in organic pollution reduction, and this was caused by the investment for the management of the interceptors in three streams of Daejeon. According to the water quality standard of the stream water quality, the recent water quality of the three streams in Daejeon was acceptable within them in the most of the water quality items, but because the total phosphorus concentration of the upstream such as Daejeon stream, Yudeng stream, Gabchen 3 location did not reach the standard values, a better management of the interceptor was required in the upstream of WTP than its downstream. The upstream of WTP also required a better management of the interceptor than the downstream. The operation and management of WTP was required a high efficiency because the water quality of the effluent from the WTP incurred an adverse effect to the target water quality in the location of the total water pollution load management system.