• Title/Summary/Keyword: 방광 용적

Search Result 33, Processing Time 0.024 seconds

Comparative evaluation of dose according to changes in rectal gas volume during radiation therapy for cervical cancer : Phantom Study (자궁경부암 방사선치료 시 직장가스 용적 변화에 따른 선량 비교 평가 - Phantom Study)

  • Choi, So Young;Kim, Tae Won;Kim, Min Su;Song, Heung Kwon;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.89-97
    • /
    • 2021
  • Purpose: The purpose of this study is to compare and evaluate the dose change according to the gas volume variations in the rectum, which was not included in the treatment plan during radiation therapy for cervical cancer. Materials and methods: Static Intensity Modulated Radiation Therapy (S-IMRT) using a 9-field and Volumetric Modulated Arc Therapy (VMAT) using 2 full-arcs were established with treatment planning system on Computed Tomography images of a human phantom. Random gas parameters were included in the Planning Target Volume(PTV) with a maximum change of 2.0 cm in increments of 0.5 cm. Then, the Conformity Index (CI), Homogeneity Index (HI) and PTV Dmax for the target volume were calculated, and the minimum dose (Dmin), mean dose (Dmean) and Maximum Dose (Dmax) were calculated and compared for OAR(organs at risk). For statistical analysis, T-test was performed to obtain a p-value, where the significance level was set to 0.05. Result: The HI coefficients of determination(R2) of S-IMRT and VMAT were 0.9423 and 0.8223, respectively, indicating a relatively clear correlation, and PTV Dmax was found to increase up to 2.8% as the volume of a given gas parameter increased. In case of OAR evaluation, the dose in the bladder did not change with gas volume while a significant dose difference of more than Dmean 700 cGy was confirmed in rectum using both treatment plans at gas volumes of 1.0 cm or more. In all values except for Dmean of bladder, p-value was less than 0.05, confirming a statistically significant difference. Conclusion: In the case of gas generation not considered in the reference treatment plan, as the amount of gas increased, the dose difference at PTV and the dose delivered to the rectum increased. Therefore, during radiation therapy, it is necessary to make efforts to minimize the dose transmission error caused by a large amount of gas volumes in the rectum. Further studies will be necessary to evaluate dose transmission by not only varying the gas volume but also where the gas was located in the treatment field.

A Comparison for Treatment Planning of Tomotherapy and Proton Therapy in Prostate Cancer (전립선암에 대한 토모치료와 양성자치료의 치료계획 비교)

  • Song, Gwan-Soo;Bae, Jong-Rim;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The prostate cancer is the most common malignant tumor in males. Prostate cancer is the most common malignant tumor that occurs in the male in Korea in 2007 to an annual average of 5,292 cases and 3.3% of the total cancer incidence seventh occurred. Our study compared property for tomotherapy and proton therapy in radiotherapy of prostate cancer patients. We analyzed DVH(Dose Volume Histogram) and dose distribution for prostate, bladder and rectum for radiation treatment planning of prostate cancer with 11 patients in Ilsan K cancer hospital from June to November 2011. There was no differences between tomotherapy and proton therapy in the purpose of prostate cancer therapy for PTV. The adjacent organs of bladder and rectum of average dose-volume were 2port proton therapy that it was low dose treatment comparing with tomotherapy and 5port proton therapy. $H{\cdot}I$ of proton therapy was less than $H{\cdot}I$ of tomotherapy. Also, 5port was less than 2port in $H{\cdot}I$ of proton therapy. However, 2port proton therapy has more advantage over 5port proton therapy that the bladder and rectum of average dose-volume and control time of equipment in radiotherapy of prostate cancer.

Survey of Caffeine levels in the Favorite Diets of Children (어린이 기호식품 중 카페인 함량에 대한 조사)

  • Lee, E-Na;Kim, Hee-Jin;Im, Ji-Young;Kim, Jeoung-A;Park, Hye-Young;Ryu, Ju-Young;Ko, Kwang-Rack;Kim, Hyung-Sik
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.3
    • /
    • pp.173-178
    • /
    • 2007
  • Children may respond differently to the caffeine from adults because they have different physiologic makeup and are functionally immature in terms of hepatic and renal function; this leads to the slower clearance of caffeine in early life. Therefore, children are often assumed to be more susceptible to caffeine effects. Alarge number of food supplements may interfere with these processes, and therefore caffeine exposure may have more serious consequences for children than for adults, irrespective of sensitivity. However, there has never been a national dietary survey on caffeine intakes in children. The purpose of our study was to identify caffeine intakes and beverage sources of caffeine in a representative sample of children in Busan, Korea. Caffeine intakes were based only on beverages included in the Continuing Surveys of Food Intakes by individuals. The caffeine content of the beverages ranged from 2.8 to 65.2mg/100ml for cola, soft drinks, and teas. Caffeine was not completely absent from caffeine-free colas, juice, and milk. In this study, cola-type beverages were an important dietary source of caffeine in the children. Daily caffeine intake for children was estimated to range from 12.5 to 250 mg/day. In general, the acceptable daily intake (ADI) of caffeine should cover the entire population including children. Therefore, special considerations should be needed regarding the consumption of soft drinks containing caffeine to children below the 12 years of age.

Estimation of the Moisture Maximizing Rate based on the Moisture Inflow Direction : A Case Study of Typhoon Rusa in Gangneung Region (수분유입방향을 고려한 강릉지역 태풍 루사의 수분최대화비 산정)

  • Kim, Moon-Hyun;Jung, Il-Won;Im, Eun-Soon;Kwon, Won-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.9
    • /
    • pp.697-707
    • /
    • 2007
  • In this study, we estimated the PMP(Probable Maximum Precipitation) and its transition in case of the typhoon Rusa which happened the biggest damage of all typhoons in the Korea. Specially, we analysed the moisture maximizing rate under the consideration of meteorological condition based on the orographic property when it hits in Gangneung region. The PMP is calculated by the rate of the maximum persisting 12 hours 1000 hPa dew points and representative persisting 12 hours 1000 hPa dew point. The former is influenced by the moisture inflow regions. These regions are determined by the surface wind direction, 850 hPa moisture flux and streamline, which are the critically different aspects compared to that of previous study. The latter is calculated using statistics program (FARD2002) provided by NIDP(National Institute for Disaster Prevention). In this program, the dew point is calculated by reappearance period 50-year frequency analysis from 5% of the level of significant when probability distribution type is applied extreme type I (Gumbel distribution) and parameter estimation method is used the Moment method. So this study indicated for small basin$(3.76km^2)$ the difference the PMP through new method and through existing result of established storm transposition and DAD(Depth-Area-Duration). Consequently, the moisture maximizing rate is calculated in the moisture inflow regions determined by meteorological fields is higher $0.20{\sim}0.40$ range than that of previous study. And the precipitation is increased $16{\sim}31%$ when this rate is applied for calculation.

Circadian Rhythm of ADH, Hypercalciuria, and Solute Diuresis as Pathogenesis of Enuresis (야뇨증의 병인 기전 -항이뇨호르몬, 고칼슘뇨증, 용질성 이뇨)

  • Kang, Hee-Gyung
    • Childhood Kidney Diseases
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Nocturnal polyuria is one of the main pathogenic mechanisms of enuresis. Disturbance of circadian rhythm of antidiuretic hormone (ADH or AVP), hypercalciuria, and/or solute diuresis are considered to cause nocturnal polyuria, which in turn causes enuresis in patients with relatively small bladder capacity and high threshold for awakening. Evaluation of these factors would guide the therapeutic approach for enuresis.

The Effect of Obesity Levels on Irradiated Small Bowel volume in Belly Board with Small Bowel Displacement Device for Rectal Cancer Radiotherapy (복부판과 소장변위도구를 사용하는 직장암의 방사선치료 시 비만도가 소장의 조사용적에 미치는 영향)

  • Kim, Se-Young;Kim, Joo-Ho;Park, Hyo-Kuk;Cho, Jeong-Hee
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.39-47
    • /
    • 2013
  • For radiotherapy in rectal cancer patients treated with small bowel displacement device (SBDD) and belly board, We will suggest new indication of using SBDD depending on obesity index by analyzing correlation between obesity and irradiated small bowel volume. In this study, We reviewed 29 rectal cancer patients who received pelvic radiation therapy with belly board and SBDD from January to April in 2012. We only analyzed those patients treated with three-field technique (PA and both LAT) on 45 Gy (1.8 Gy/fx). We measured patients' height, weight, body mass index (BMI), waist-hip ratio (WHR) and divided BMI into two groups.(${\geq}23$:BMI=group1, <23:BMI=group2) We performed a statistical analysis to evaluate correlation between total volume of bladder($TV_{bladder}$), obesity index and high dose volume of small bowel (small bowel volume irradiated at 90% of prescribed dose, $HDV_{sb}$), low dose volume of small bowel (small bowel volume irradiated at 33% of prescribed dose, $LDV_{sb}$). The result shows, gender, WHR and status of pre operative or post operative do not greatly affect $HDV_{sb}$ and $LDV_{sb}$. Statistical result shows, there are significant correlation between $HDV_{sb}$ and BMI (p<0.04), $HDV_{sb}$ and $TV_{bladder}$ (p<0.01), $LDV_{sb}$ and $TV_{bladder}$ (p<0.01). BMI seems to correlate with $HDV_{sb}$ but does not with $LDV_{sb}$ (p>0.05). There are negative correlation between $HDV_{sb}$ and BMI, $TV_{bladder}$ and $HDV_{sb}$, $TV_{bladder}$ and $LDV_{sb}$. Especially, BMI group1 has more effective and negative correlation with $HDV_{sb}$ (p=0.027) than in BMI group2. In the case of BMI group 1, $TV_{bladder}$ has significant negative correlation with $HDV_{sb}$ and $LDV_{sb}$ (p<0.04). In conclusions, we confirmed that Using SBDD with belly board in BMI group1 could more effectively reduce irradiated small bowel volume in radiation therapy for rectal cancer. Therefore, We suggest using belly board with SBDD in order to reduce the small bowel toxicity in rectal radiotherapy, if patients' BMI is above 23.

Infrequent Voiding Induced Acute Pyelonephritis in a Thirteen-Year Old Girl (가뭄뇨로 인한 급성 신우신염 1례)

  • Ahn Hye Young;Pai Ki-Soo;Lee Jin Yong;Kim Pung-Kil;Lee Jae Seung
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.69-72
    • /
    • 2001
  • Infrequent voiding is defiled as two or less micturitions in a day without organic causes. It can 1ead to bladder capacity enlargement and increase in the volume of residual urine and as a consequence it may produce recurrent urinary tract infections(UTI) and or renal damages. We report a case of acute pyelonephritis due to infrequent voiding in a 13 year old girl. The imaging studies revealed floating debris in the bladder on VCUG and dilated ureter on ultrasonography, and parenchymal defects on 99mTc DMSA scan. (J. Korean Soc Pediatr Nephrol 5 : 69- 72, 2001)

  • PDF

A Comparison between Three Dimensional Radiation Therapy and Intensity Modulated Radiation Therapy on Prostate Cancer (전립샘암의 방사선 치료 시 입체조형치료법와 세기조절방사선 치료법의 비교)

  • Kim, YoungJae;Lee, JaeSub;Hong, Seongill;Ko, HyeJin
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.409-414
    • /
    • 2013
  • In this study, we evaluated to the superiority of treatment techniques on prostate cancer, apply to each other treatment techniques-3D conformal therapy versus IMRT-using dose distribution and dose coverages. Obtained 10 patients CT simulation, divided tumor volume and critical organs. Prescription dose was 80 Gy on tumor volume and Each of plans was set by two different plans. As a result, Dose coverage was superior to IMRT. The IMRT's tumor absorbed dose(100.2%) was close to prescription doses. Normal tissue(bladder, rectal, bowel Lt Rt fumoral head) absorbed dose rate was superior. In other words, the radiation therapy of prostate cancer with intensity modulated radiation therapy was better than conformal radiation therapy on dose.

Packing effects on the intracavitary radiation Therapy 3-Dimension plan of the uterine cervix cancer (자궁경부암 강내조사 3차원 치료계획 시 Packing의 유용성 분석)

  • Si, Chang-Keun;Jo, Jung-Kun;Lee, Du-Hyun;Kim, Sun-Yeung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose : An effect of a packing to uterine treatment of a cervical cancer using a dose-volume histogram for a point dose and a volume dose of the bladder and the rectum was analyzed by establishing a three-dimensional treatment plan using a CT image. Materials and methods : Reference points of the bladder and the rectum were marked, respectively at a treatment plan device (plato brachytherapy V14.2.4) by photographing CT(marconi, USA) when the packing was used and removed under the same condition and a treatment plan was performed to Apoint depending on ICRU38. However, in case of the rectum, a maximum point was looked up and compared with the above point because the point presented from the ICRU is not proper as a representative value of a rectum point dose. Further, the volume dose depending on volume of $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder was measured. The measured values were used to analyze the effect of the packing through a Wilcoxon Signed Rank Test (a SAS statistical analysis process program). Result : The reference points at the bladder and rectum doses when the packing was removed were $116.94\;35.42\%$ and $117.59\;21.08\%$, respectively. The points when the packing was used were $107.08\;38.12\%$ and $95.19\;21.32\%$, respectively. After the packing was used, the reference points at the bladder and the rectum were decreased by $9.86\%$ and $22.4\%$, respectively. When the packing was removed, the maximum points at the bladder and the rectum were $164.51\;50.89\%,\;128.81\;33.05\%$, respectively. When the packing was used, the maximum points at the bladder and the rectum were $142.31\;44.79,\;110.08\;37.03\%$, respectively. After the packing was used, the maximum points at the bladder and the rectum were decreased by $22.2\%$ and $18.73\%$, respectively. When the packing was removed, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $48.62{\pm}18.09\%,\;16.12{\pm}11.15\%,\;and\;7.51{\pm}6.63\%$, respectively and its rectum volume were $23.41{\pm}14.44\%,\;6.27{\pm}4.28\%,\;2.79{\pm}2.27\%$, respectively. When the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $40.33{\pm}16.72,\;11.63{\pm}8.72,\;and\;4.87{\pm}4.75\%$, respectively and its rectum volume were $18.96{\pm}8.37\%,\;4.75{\pm}2.58\%,\;and\;1.58{\pm}1.06\%$, respectively. After the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were decreased by $8.29\%,\;4.49\%,\;and\;2.64\%$, respectively and its bladder volume were decreased by $4.45\%,\;1.52\%,\;and\;1.21\%$, respectively. Conclusion : Values at Reference point doses of the bladder and the rectum recommended from the ICRU 38 were 0.0781 and 0.0781, respectively and values of their maximum point doses were 0.0156 and 0.0156, respectively, as a result of which an effect of the packing using at the uterine intracavitary treatment of an uterine cervical cancer through the three-dimensional treatment plan used CT were measured. That is, the values at reference point doses and the values at maximum point doses show similar difference. However, P value was 0.15 at over $50\%,\;80\%,\;and\;100\%$ volume doses and the value shows no similar difference. In other words, the effect of the packing looks like having a difference at the point dose, but actually shows no difference at the volume dose. The reason is that the volume of the bladder and the rectum are wide but the volume of the packing is only a portion. Therefore, the effect of decreasing the point dose was not great. Further, the farer the distance is, the more weak the intensity of radiation is because the intensity of radiation is proportional to inverse square of a distance. Therefore, the effort to minimize an obstacle of the bladder and the rectum by using the packing should be made.

  • PDF

Study on Bladder Dysfunction in Elderly Women by the BFLUT Questionnaire and Bladder Scanner: Frequency and Residual Urine (질문지법과 초음파 방광용적진단기를 이용한 여성노인의 배뇨장애연구 -빈뇨, 잔뇨를 중심으로)

  • Kim, Jeung-Im
    • Women's Health Nursing
    • /
    • v.17 no.3
    • /
    • pp.294-303
    • /
    • 2011
  • Purpose: This study aimed to describe bladder dysfunction in elderly women such as frequency, nocturia, and residual urine. Methods: One hundred elderly women aged 60 and over. The Bristol Female Lower Urinary Symptoms (BFLUT) was used to evaluate the bladder function and to measure the residual urine amount by using a bladder scanner. Data was analyzed with the differences between voiding dysfunction by age group and life habits by t-test, ANOVA and correlation by Pearson correlation coefficient. Results: the mean daytime frequency was 6.8 times and night-time frequency 2.7 times. Sixty three percent of subjects had urgency and 41% had urgent incontinence. Over half of subjects had problem in voiding function. There were significant differences in frequency by age groups and constipation, but not in daytime frequency and residual urine. Lastly, there were significant positive relations between daytime frequency and night-time frequency. Also results indicate that more frequency in daytime equaled to a less residual urine amount. Conclusion: We know many elderly women have lower urinary tract symptoms. Specially women over 75 years have more daytime frequency and night-time frequency. This suggests further research needed in order to understand the relation of voiding patterns and life habits and its influence on quality of life.