• Title/Summary/Keyword: 방광체적

Search Result 26, Processing Time 0.021 seconds

A comparison of bladder volume by sonogram and CBCT for Pelvic region cancer (골반부 암 치료 시 초음파검사를 통한 방광체적과 CBCT영상 방광체적의 비교)

  • Son, Seong Ho;Park, Ha Ryung;Baek, Jung Jin;Son, Jong Ki;Choi, Min Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.7-12
    • /
    • 2019
  • Purpose: During the pelvic radiation therapy, it is performed with controlling bladder volume because the range of irradiation is changed depending on the bladder volume. Therefore in this study, we evaluate the accuracy of BVI by tracing the change of bladder volume using ultrasonic pulse diagnosis equipment(BVI 6100, Medical supply Co. LTD) Material and Methods: From January 2017 to September 2018, 19 patients who received pelvic radiation therapy at Pusan National University Hospital were included. To treat the patient, we compared that the bladder volume obtained from the BVI and the bladder volume obtained from the CBCT image then we evaluated for significance. Results: There was a significant correlation of r=0.773, BVI and CBCT in the whole volume section. However, based on the bladder volume in the RTP Image the p value was shown to be 0 at 125~175cc and lower than 0.05 at 175~275cc, And more than 0.05 at 275~375cc. Conclusions: In this study, the patient whose bladder volume is above than 275cc, there is a significance of bladder volume between BVI and CBCT image. However, we could make a decision to be undermined the reliability of BVI measurement in the case of the patient with emptied his urine. Therefore, it is possible to acquire a significant value for 175~275cc patients to use the correction value of BVI and the appropriate tolerance of volume.

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

Bladder volume variations of cervical cancer patient in radiation therapy using ultrasonography (초음파검사를 이용한 자궁경부암 환자의 방사선치료 시 방광 체적 변화)

  • Gong, Jong Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • Purpose : The bladder volume change was measured using ultrasonography for helping decrease the side effects and other organ variations in the location of radiation therapy for cervical cancer patients. An experiment was performed targeting patients who were treated with radiation therapy at PNUH within the period from September to December 2015. Materials and Methods : To maintain the bladder volume, each patient was instructed to drink 500 cc water before and after CT simulation, 60 minutes before the dry run. Also, the bladder volume was measured in each patient CT scan, and a 3D conformal therapy plan was designed. The bladder volumes measured before and after the CT simulation, dry run, and radiation treatment planning were compared and analyzed. Results : The average volume and average error of the bladder that were obtained from the measurement based on the CT scan images had the lowest standard deviation in the CT simulation. This means that the values that were obtained before and after the CT simulation were statistically relevant and correlative. Moreover, the bladder volume measured via ultrasonography was larger size, the average volume in the CT scan. But the values that were obtained Dry run and after the CT simulation were not statistically relevant. Conclusion : Drinking a certain amount of water helps a patient maintain his/her bladder volume for a dry run. Even then, it is difficult to maintain the bladder volume for the dry run. Also, whether or not the patients followed the directions for the dry run correctly is important.

  • PDF

The Efficacy of the Change in Belly Board Aperture Location by the Addition of Bladder Compression Device for Radiotherapy of Rectal Cancer (직장암 환자의 골반 방사선치료에서 벨리보드 하위 경계 위치 변화의 영향)

  • Yoon, Hong-In;Chung, Yoon-Sun;Kim, Joo-Ho;Park, Hyo-Kuk;Lee, Sang-Kyu;Kim, Young-Suk;Choi, Yun-Seon;Kim, Mi-Sun;Lee, Ha-Yoon;Chang, Jee-Suk;Cha, Hye-Jung;Seong, Jin-Sil;Keum, Ki-Chang;Koom, Woong-Sub
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.231-237
    • /
    • 2010
  • Purpose: We investigated the effect of location changes in the inferior border of the belly board (BB) aperture by adding a bladder compression device (BCD). Materials and Methods: We respectively reviewed data from 10 rectal cancer patients with a median age 64 years (range, 45~75) and who underwent computed tomography (CT) simulation with the use of BB to receive pelvic radiotherapy between May and September 2010. A CT simulation was again performed with the addition of BCD since small bowel (SB) within the irradiated volume limited boost irradiation of 5.4 Gy using the cone down technique after 45 Gy. The addition of BCD made the inferior border of BB move from symphysis pubis to the lumbosacral junction (LSJ). Results: Following the addition of BCD, the irradiated volumes of SB and the abdominopelvic cavity (APC) significantly decreased ($174.3{\pm}89.5mL$ vs. $373.3{\pm}145.0mL$, p=0.001, $1282.6{\pm}218.7mL$ vs. $1,571.9{\pm}158mL$, p<0.001, respectively). Bladder volume within the treated volume increased with BCD ($222.9{\pm}117.9mL$ vs. $153.7{\pm}95.5mL$, p<0.001). The ratio of irradiated bladder volume to APC volume with BCD ($33.5{\pm}14.7%$) increased considerably compared to patients without a BCD ($27.5{\pm}13.1%$) (p<0.001), and the ratio of irradiated SB to APC volume decreased significantly with BCD ($13.9{\pm}7.6%$ vs. $24.2{\pm}10.2%$, p<0.001). The ratios of the irradiated SB volume and irradiated bladder volume to APC volume negatively correlated (p=0.001). Conclusion: This study demonstrated that the addition of BCD, which made the inferior border of BB move up to the LSJ, increased the ratio of the bladder to APC volume and as a result, decreased the irradiated volume of SB.

The 3-Dimensional Analysis of the Efficacy of a Belly-Board Device for the Displacement of Small Bowel During Pelvic Irradiation (골반강 방사선치료 중 소장의 이동을 위한 벨리보드의 효과에 대한 3차원적 분석)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.271-279
    • /
    • 2008
  • Purpose: To evaluate the efficacy of a belly-board device (BBD) in reducing the volume of small bowel during four-field pelvic irradiation. Materials and Methods: Twenty-two cancer patients (14 uterine cervical cancer, 6 rectal cancer, and 2 endometrial cancer) scheduled to receive pelvic irradiation were selected for this study. Two sets of CT images were taken with and without the belly-board device using the Siemens 16 channel CT scanner. All patients were set in the prone position. The CT images were transferred to a treatment planning system for dose calculation and volume measurements. The external surfaces of small bowel and the bladder were contoured on all CT scans and the 4-pelvic fields were added. The dose-volume-histogram of the bladder and small bowel, with and without the BBD, were plotted and analyzed. Results: In all patients, the total small bowel volume included in the irradiated fields was reduced when the BBD was used. The mean volume reduction was 35% (range, $1{\sim}79%$) and was statistically significant (p<0.001). The reduction in small bowel volume receiving $10{\sim}100%$ of the prescribed dose was statistically significant when the BBD was used in all cases. Almost no change in the total bladder volume involved was observed in the field (<8 cc, p=0.762). However, the bladder volume receiving 90% of the prescribed dose was 100% in 15/22 patients (68%) and $90{\sim}99%$ in 7/22 patients (32%) with the BBD. In comparison, the bladder volume receiving 90% of the prescribed dose was 100% in 10/22 patients (45%), $90{\sim}99%$ in 7/22 patients (32%), and $80{\sim}89%$ in 5/22 patients (23%) without the BBD. When the BBD was used, an increase in the bladder volume receiving a high dose range was observed Conclusion: This study shows that the use of a BBD for the treatment of cancer in the pelvic area significantly improves small bowel sparing. However, since the BBD pushed the bladder into the treatment field, the bladder volume receiving the high dose could increase. Therefore it is recommended to be considerate in using the BBD when bladder damage is of concern.

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

The Investigation Image-guided Radiation Therapy of Bladder Cancer Patients (방광암 환자의 영상유도 방사선치료에 관한 고찰)

  • Bae, Seong-Soo;Bae, Sun-Myoung;Kim, Jin-San;Kang, Tae-Young;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 2012
  • Purpose: In hospital image-guided radiation therapy in patients with bladder cancer to enhance the reproducibility of the appropriate amount, depending on the patient's condition, and image-guided injection of saline system (On-Board Imager system, OBI, VARIAN, USA) three of the Cone-Beam CT dimensional matching (3D-3D matching) to be the treatment. In this study, the treatment of patients with bladder cancer at Cone-Beam CT image obtained through the analysis of the bones based matching and matching based on the bladder to learn about the differences, the bladder's volume change injected saline solution by looking at the bladder for the treatment of patients with a more appropriate image matching is to assess how the discussion. Materials and Methods: At our hospital from January 2009 to April 2010 admitted for radiation therapy patients, 7 patients with bladder cancer using a Folly catheter of residual urine in the bladder after removing the amount determined according to individual patient enough to inject saline CT-Sim was designed after the treatment plan. After that, using OBI before treatment to confirm position with Cone-Beam CT scan was physician in charge of matching was performed in all patients. CBCT images using a total of 45 bones, bladder, based on image matching and image matching based on the difference were analyzed. In addition, changes in bladder volume of Eclipse (version 8.0, VARIAN, USA) persuaded through. Results: Bones, one based image matching based on the bladder and re-matching the X axis is the difference between the average $3{\pm}2mm$, Y axis, $1.8{\pm}1.3mm$, Z-axis travel distance is $2.3{\pm}1.7mm$ and the overall $4.8{\pm}2.0mm$, respectively. The volume of the bladder compared to the baseline showed a difference of $4.03{\pm}3.97%$. Conclusion: Anatomical location and nature of the bladder due to internal movement of the bones, even after matching with the image of the bladder occurred in different locations. In addition, the volume of saline-filled bladder showed up the difference between the 4.03 percent, but matched in both images to be included in the planned volumes were able to confirm. Thus, after injection of saline into the bladder base by providing a more accurate image matching will be able to conduct therapy.

  • PDF

Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data (CT 및 초음파 스캔 데이터를 이용한 체적 측정의 정확도 및 유용성)

  • Kim, Hyeon-Ju;Lee, Hoo-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • In this study, the accuracy and usefulness of volume measurement were investigated as a phantom experiment using CT and USG scan data and a clinical trial using patient scan data. As a result, there was no significant difference between the volume of the actual round phantom of various volumes for both the CT and ultrasound devices (p>0.05). As a result of statistical analysis, it was analyzed that there was no significant difference (p>0.05). Clinical application of this result requires more clinical trials, but if a CT or ultrasound device is selected and applied in consideration of patient radiation exposure, the examiner's scanning technology, and CT reconstruction experience, the basic data in terms of the usefulness of volume measurement using CT scan image is considered to have application value.

Comparison of 2D and 3D Brachytherapy Planning for Cervical Cancer (자궁경부암 근접방사선치료 시 2차원, 3차원 치료계획 비교평가)

  • Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.303-309
    • /
    • 2017
  • To evaluate the usefulness of 3-dimensional brachytherapy(BT) planning technique based on CT in cervical cancer. Patients with cervical cancer underwent 2-D BT treatment planning and then CT scan with HDR intracavitary applicators in place with same positions. Dose was prescribed to Point A with 5Gy per fraction on 2-D BT planning. For 3-D BT planning, and dose was prescribed to the High risk CTV for BT (HR CTV) with 5Gy. The 3-D BT planning goal was to cover at least 90% of the HR CTV with target 5Gy isodose surface while limiting the dose to $2cm^3$ of bladder to less than 7.5 Gy, and $2cm^3$ of rectum to less than 5Gy. In one patient of 10 patients, $D_{2cm3}$ of rectal dose was over 5Gy and 6patients at $D_{2cm3}$ of bladder dose on 2-D BT planning. There was a tendency to underestimate ICRU bladder dose than ICRU rectal dose. CT based 3-D BT planning for cervical cancer will enable evaluation of dose distributions for tumor and critical organs at risk. So, rectal and bladder morbidity as well as geographic miss will be reduced in case of the bulky disease or uterine malposition.

Packing effects on the intracavitary radiation Therapy 3-Dimension plan of the uterine cervix cancer (자궁경부암 강내조사 3차원 치료계획 시 Packing의 유용성 분석)

  • Si, Chang-Keun;Jo, Jung-Kun;Lee, Du-Hyun;Kim, Sun-Yeung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose : An effect of a packing to uterine treatment of a cervical cancer using a dose-volume histogram for a point dose and a volume dose of the bladder and the rectum was analyzed by establishing a three-dimensional treatment plan using a CT image. Materials and methods : Reference points of the bladder and the rectum were marked, respectively at a treatment plan device (plato brachytherapy V14.2.4) by photographing CT(marconi, USA) when the packing was used and removed under the same condition and a treatment plan was performed to Apoint depending on ICRU38. However, in case of the rectum, a maximum point was looked up and compared with the above point because the point presented from the ICRU is not proper as a representative value of a rectum point dose. Further, the volume dose depending on volume of $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder was measured. The measured values were used to analyze the effect of the packing through a Wilcoxon Signed Rank Test (a SAS statistical analysis process program). Result : The reference points at the bladder and rectum doses when the packing was removed were $116.94\;35.42\%$ and $117.59\;21.08\%$, respectively. The points when the packing was used were $107.08\;38.12\%$ and $95.19\;21.32\%$, respectively. After the packing was used, the reference points at the bladder and the rectum were decreased by $9.86\%$ and $22.4\%$, respectively. When the packing was removed, the maximum points at the bladder and the rectum were $164.51\;50.89\%,\;128.81\;33.05\%$, respectively. When the packing was used, the maximum points at the bladder and the rectum were $142.31\;44.79,\;110.08\;37.03\%$, respectively. After the packing was used, the maximum points at the bladder and the rectum were decreased by $22.2\%$ and $18.73\%$, respectively. When the packing was removed, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $48.62{\pm}18.09\%,\;16.12{\pm}11.15\%,\;and\;7.51{\pm}6.63\%$, respectively and its rectum volume were $23.41{\pm}14.44\%,\;6.27{\pm}4.28\%,\;2.79{\pm}2.27\%$, respectively. When the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $40.33{\pm}16.72,\;11.63{\pm}8.72,\;and\;4.87{\pm}4.75\%$, respectively and its rectum volume were $18.96{\pm}8.37\%,\;4.75{\pm}2.58\%,\;and\;1.58{\pm}1.06\%$, respectively. After the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were decreased by $8.29\%,\;4.49\%,\;and\;2.64\%$, respectively and its bladder volume were decreased by $4.45\%,\;1.52\%,\;and\;1.21\%$, respectively. Conclusion : Values at Reference point doses of the bladder and the rectum recommended from the ICRU 38 were 0.0781 and 0.0781, respectively and values of their maximum point doses were 0.0156 and 0.0156, respectively, as a result of which an effect of the packing using at the uterine intracavitary treatment of an uterine cervical cancer through the three-dimensional treatment plan used CT were measured. That is, the values at reference point doses and the values at maximum point doses show similar difference. However, P value was 0.15 at over $50\%,\;80\%,\;and\;100\%$ volume doses and the value shows no similar difference. In other words, the effect of the packing looks like having a difference at the point dose, but actually shows no difference at the volume dose. The reason is that the volume of the bladder and the rectum are wide but the volume of the packing is only a portion. Therefore, the effect of decreasing the point dose was not great. Further, the farer the distance is, the more weak the intensity of radiation is because the intensity of radiation is proportional to inverse square of a distance. Therefore, the effort to minimize an obstacle of the bladder and the rectum by using the packing should be made.

  • PDF