• Title/Summary/Keyword: 발전 출력

Search Result 1,263, Processing Time 0.043 seconds

Variation of Liquid to Gas Ratio and Sulfur Oxide Emission Concentrations in Desulfurization Absorber with Coal-fired Thermal Power Plant Outputs (석탄화력 발전설비의 출력에 따른 탈황 흡수탑 액기비와 황산화물 배출농도 변화에 대한 연구)

  • Kim, Kee-Yeong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.39-47
    • /
    • 2018
  • In this research, when the output of the standard coal-fired thermal power plant operating continuously at the rated output of 500 MW is changed to operate at 300 to 500 MW, the amount of sulfur oxide produced and the amount of sulfur oxide in the absorption tower of desulfurization equipment and proposed an extra liquid to gas ratio improvement inversely proportional to the output. In order to calibrate the combustion efficiency at low power, the ratio of sulfur oxides relative to the amount of combustion gas is increased as the excess air ratio is increased. When the concentration of sulfur oxide at the inlet of the desulfurization absorber was changed from 300 to 500 ppm along with the output fluctuation. The liquid to gas ratio of limestone slurry and combustion gas was changed from 10.99 to 16.27. Therefore, if the concentration of sulfur oxides with output of 300 MW is x, The following correlation equation is recommended for the minimum required flow rate of slurry for the reduction of surplus energy due to the increase of the liquid weight at low load. $y1[m^3/sec]=0.11x+3.74$

  • PDF

Performance Characteristics of the 300 MW Integrated Gasification Combined Cycle Plant according to Ambient Temperature (대기온도에 따른 300 MW 석탄가스화복합발전 성능특성)

  • Kim, Young-Mook;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.3
    • /
    • pp.29-34
    • /
    • 2018
  • In this study, the output and thermal efficiency of Taean Integrated Gasification Combined Cycle Plant were calculated by using the manufacturer's basic design data and the performance correction factor for each atmospheric temperature, and the actual performance was measured at summer and winter representative points. The results were compared with the calculated values to verify their validity. The thermal efficiency is the highest at around $15^{\circ}C$ and lower at lower temperature and higher temperature. This is similar to that of natural gas Combined Cycle Power Plant, but the thermal efficiency has drastically decreased due to the increase of power consumption of the air separation unit at relatively high temperature. The output is highest in the range of 5 to $15^{\circ}C$, and is kept almost constant at below $5^{\circ}C$ and declines above $15^{\circ}C$. The reason why the output does not increase at low temperatures is that the torque limit of the shaft is activated by the increase of the flow rate due to the nitrogen injection of the gas turbine combustor. In order to improve the performance in the future, efforts should be made to improve the power generation output and to reduce the power consumption of the air separation unit in summer.

  • PDF

A Study on Hybrid Control Unit Using a Smart Control (스마트 제어를 이용한 하이브리드 형 제어장치 연구)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1093-1100
    • /
    • 2016
  • This study is to demonstrate the superiority and stability of the solar - wind power hybrid power generation system for street lamps using super capacitor EDLC(:Electric Double Layer Capacitor). It is aiming to apply the lighting device using LED light source as the load of solar-wind power hybrid power generation system for independent power source and to develop the street light system device with high output power generation system. Unlike conventional controllers, EDLC, which is used as an auxiliary device for storing the developed power in the battery, can guarantee the high output and long life of the battery.

Analysis of prediction model for solar power generation (태양광 발전을 위한 발전량 예측 모델 분석)

  • Song, Jae-Ju;Jeong, Yoon-Su;Lee, Sang-Ho
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.243-248
    • /
    • 2014
  • Recently, solar energy is expanding to combination of computing in real time by tracking the position of the sun to estimate the angle of inclination and make up freshly correcting a part of the solar radiation. Solar power is need that reliably linked technology to power generation system renewable energy in order to efficient power production that is difficult to output predict based on the position of the sun rise. In this paper, we analysis of prediction model for solar power generation to estimate the predictive value of solar power generation in the development of real-time weather data. Photovoltaic power generation input the correction factor such as temperature, module characteristics by the solar generator module and the location of the local angle of inclination to analyze the predictive power generation algorithm for the prediction calculation to predict the final generation. In addition, the proposed model in real-time national weather service forecast for medium-term and real-time observations used as input data to perform the short-term prediction models.

Multi Output Hybrid Three level DC-DC Converter (하이브리드 3레벨 다출력 DC-DC 컨버터)

  • Kang, C.H;Lee, H.S;Ju, J.S;Malon, H.E;Kim, E.S;Lee, S.M;Kim, K.S
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.9-10
    • /
    • 2014
  • 최근 신재생에너지 및 전기자동차, 통신 IT 서버 전원 및 가전기기 등의 발전에 따라 고 전력밀도(High Power Density), 고 응답(Fast Transient Response) 및 고정밀(Tight Regulation) 출력제어를 위한 다 출력 절연형 DC/DC 컨버터가 개발 및 연구되고 있다. 본 논문에서는 개별적인 정밀제어를 요구하는 다 출력 DC-DC 컨버터에 대한 내용으로 위상천이(Phase-shift) DC-DC 컨버터와 LLC 공진컨버터 제어개념을 하나의 주회로를 사용하여 위상천이제어(Phase-shifted Modulation, PM)와 가변주파수제어(Variable Frequency Modulation, FM)를 통해서 개별적으로 정밀 제어할 수 있는 하이브리드 다 출력 3레벨 DC-DC 컨버터에 관한 내용이다.

  • PDF

A Study of changes in wind output stabilization system Through simulation (시뮬레이션을 통한 풍력변동 출력안정화 시스템관한 연구)

  • Song, Kwang-Seok;Lee, Won-Jin;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.261-262
    • /
    • 2014
  • 본 논문은 풍력 발전 출력 안정화 성능을 평가하기 위해서는 다양한 부하변동과 계통 사고에 대한 검증이 필수적이나, 실제로 다양한 조건에서 실증하기는 현실적으로 불가능하여, 본 논문에서는 축소형 시뮬레이터를 통하여 제안된 알고리즘 검증하고자 한다. 특히 전체구성의 적용을 위해 3상 농형 유도전동기를 통한 발전기의 출력을 유도하였으며 이를 위한 인버터를 사용하여 시뮬레이터를 구성하였고 지형별 특성에 맞는 데이터를 기반으로 풍력데이터를 입력하여 출력조건을 형성하였다. 또한 조상기와 덤프로드를 통해 부하의 출력변동분에 대한 계측과 분석에 초점을 맞추어 특성 계측이 가능하도록 구성할 수 있다.

  • PDF

PV모듈 전.후면 재료별 PID에 의한 출력 변화

  • Kim, Han-Byeol;Jeong, Tae-Hui;Gang, Gi-Hwan;Jang, Hyo-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.312.1-312.1
    • /
    • 2013
  • PID (Potential Induced Degradation)는 높은 시스템 전압을 갖는 PV모듈에서 발생하는 현상으로 PV모듈의 출력을 급격하게 감소시키는 현상을 말한다. PV시스템의 높은 전압은 태양전지와 PV모듈의 프레임 사이에 전위차를 발생시키고 이로 인하여 누설전류가 흐르게 된다. 누설전류는 태양전지 표면에 전하를 축적 시켜 발전 효율을 감소시키게 된다. 이러한 누설전류는 온도와 습도가 높을수록 많이 발생하는 것으로 알려져 있다. 본 논문에서는 PV모듈을 구성하는 재료가 PID에 의한 출력변화에 어떠한 영향을 주는지에 관한 연구를 수행하였다. PID가 쉽게 발생하는 태양전지를 이용하여 일반적으로 PV모듈을 제작 할 때 사용되는 전 후면 재료를 이용하여 각각의 출력변화에 대한 연구를 수행하였다. PV모듈의 전 후면 재료를 각각 다르게 하여 이에 따른 PID 발생 정도를 출력 변화로 확인하였으며 PID의 원인이 되는 누설전류에 어떠한 변화를 주는지 분석하였다. PV모듈의 후면 재료는 PV모듈 내부로의 수분 침투와 관련하여 PID 발생에 영향을 주고 전면재료인 저철분 강화유리는 PV모듈 내부에 전하를 공급하여 누설전류가 발생하게 하는 역할을 하는 것으로 판단된다.

  • PDF

분산형 발전시스템의 기술개발 동향 - 마이크로 가스터빈 발전시스템 기술개발 동향

  • Kim, Min-Guk;Kim, Han-Seok;An, Guk-Yeong
    • 기계와재료
    • /
    • v.26 no.1
    • /
    • pp.6-15
    • /
    • 2014
  • 마이크로 가스터빈은 수백 kW의 전기를 생산하는 시스템으로, 최근 천연가스 이용의 확산과 분산 발전에 대한 관심이 증가되면서 기술 개발에 대한 요구가 증가하고 있다. 재생열교환기의 도입과 CHP 시스템 적용을 통해 에너지 효율을 개선하고 각 부품의 가격 경쟁력이 확보된다면, 단위 면적당 출력이 높고, 낮은 공해 물질 배출 특성을 갖는 마이크로 가스터빈은 입지 선정이 용이하고 기존의 도시 가스 공급망을 활용할 수 있다는 측면에서 분산형 발전 시스템의 핵심 역할을 담당할 수 있을 것이다. 이에 마이크로 가스터빈의 기술개발 동향을 소개하고자 한다.

  • PDF

Wind Turbine Power Control to Minimize Power Loss within Wind Farm (풍력발전단지 내 송전손실 최소화를 위한 풍력발전기 출력 제어)

  • Kim, Yun-Soo;Jeong, Ho-Yong;Moon, Seung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.240-241
    • /
    • 2011
  • 풍력발전단지가 급속히 증가함에 따라 풍력발전단지의 제어를 통한 계통 규정 참여가 중요해지고 있다. 본 논문에서는 풍력발전단지 내에서의 송전손실을 최소화하기 위한 풍력발전기의 제어 방식을 제안한다. 모의 계통은 덴마크 해상풍력단지 Horns Rev를 본떴으며 풍력발전기 별로 적용되는 풍속도 Wake Effect를 고려한 실제 데이터를 사용하였다. 손실 최소화를 위해 Linear Programming(LP)에 기반을 둔Optimal Power Flow(OPF)를 사용하였다.

  • PDF

발전용 연료전지 PCS 기술 및 개발 동향

  • Choe, Se-Wan
    • KIPE Magazine
    • /
    • v.15 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • 발전용 연료전지로서 가장 유망한 MCFC와 SOFC는 현재 국내에서도 활발히 상용화가 진행되고 있다. 300kW급의 스택을 이용하여 작게는 수MW급 분산전원으로부터 수십 또는 수백 MW급의 대규모 발전플랜트를 구축하는데 있어서 PCS는 전체가격의 10~25%를 차지하는 상용화에 매우 중요한 핵심 장치이다. 본고에서는 발전용 연료전지 PCS의 국내외 기술개발 동향을 소개하고 저전압 출력의 PCS 기술 및 PCS의 대규모화에 요구되는 차세대 기술과 기술적인 이슈를 소개하고자 한다.