• Title/Summary/Keyword: 반전시간

Search Result 146, Processing Time 0.041 seconds

Understanding the Effects of the Dispersion and Reflection of Lamb Waves on a Time Reversal Process (램파의 분산성과 파 반사가 시간반전과정에 미치는 영향의 이해)

  • Park, Hyun-Woo;Kim, Sung-Bum;Sohn, Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.89-103
    • /
    • 2009
  • This study investigates the applicability of the time reversal concept in modem acoustics to the Lamb waves, which have been widely studied for defect detection in plate-like structures. According to conventional time reversal acoustics, an input signal can be reconstructed at an excitation point if an output signal recorded at another point is reversed in the time domain and emitted back to the original source point. However, the application of a time reversal process(TRP) to Lamb wave propagations is complicated due to velocity and amplitude dispersion characteristics of Lamb waves and reflections from the boundaries of a structure. In this study, theoretical investigations are presented to better understand the time reversibility of Lamb waves. In particular, the effects of within-mode dispersion, multimode dispersion, amplitude dispersion, and reflections from boundaries on the TRP are theoretically formulated. Simple numerical case studies are conducted to validate the theoretical findings of this study.

Simulating the Spatial Focusing of Time Reversal Lamb Waves Using Virtual Sensors (가상탐지자를 이용한 시간반전램파의 공간모임 모사)

  • Park, Hyun-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.295-298
    • /
    • 2011
  • 최근 3년간 판 구조물의 손상진단에서 시간반전램파 (Time reversal Lamb waves)의 가능성이 주목 받고 있다. 시간반전음향학(Time reversal acoustics)에 의하면 시간반전램파의 공간모임을 적절히 활용하면 판에 순간적으로 가해지거나 발생한 충격하중의 위치를 높은 공간해상도와 신호대 잡음비로 추정할 수 있다고 알려져 있다. 이 연구에서는 시간반전램파의 공간모임을 직사각형 평판에서 가상탐지자 모델을 이용하여 모사한다. 특히, 평판에서의 파 반사에 의해 발생하는 가상탐지자 효과에 의해 단일 부착형 압전소자만을 사용하더라도 시간반전 램파의 공간 모임 구현이 가능함을 보인다. 또한 제안된 방법의 결과를 유한 요소 해석결과와 비교하고 제안된 방법의 타당성을 보인다.

  • PDF

Investigating the Spatial Focusing of Time Reversal Lamb Waves Using a Virtual Sensor Model on a Rectangular Plate (직사각형 판에서 가상탐지자 모델을 이용한 시간반전램파의 공간모임 규명)

  • Park, Hyun-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.553-567
    • /
    • 2011
  • During the last three years, the possibility of the time reversal Lamb waves has been paid attention to for structural health monitoring of a plate. This study proposes a numerical scheme which can simulate the spatial focusing of time reversal Lamb waves on a rectangular plate. In this scheme, a time reversal process is formulated in the frequency domain using active virtual sensors being equivalent to the mirror effects of an actual sensor due to wave reflection on the plate boundary. Forward and backward Lamb wave propagations are represented by scalar functions for simulating the spatial focusing of time reversal Lamb waves. The validity of the proposed scheme is demonstrated through the comparison to the results of finite element analysis in which the spatial focusing of time reversal Lamb waves is realized by wafer-type piezoelectric(PZT) transducers collocated on a rectangular plate.

Variation of Asymmetric Hysteresis Loops with Annealing Temperature and Time (열처리 온도와 시간에 따른 비대칭 자기 이력 곡선의 변화)

  • 신경호;민성혜;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.4
    • /
    • pp.251-260
    • /
    • 1995
  • It has been reported that Co-based amorphous ferromagnetic alloys annealed in a small magnetic field develop a reproducible, asymmetric hysteresis loop. If the direction of the field during annealing is regarded as +, the magnetization reversal from - to + is smooth and reversible, with its slope determined by the demagnetizing field of the sample. This phenomenon is called the asymmetric magnetization reversal (AMR). The shape of the hyster-esis loop depends sensitively on the condition during the anneal and the alloy composition. Here, we report on the effect of the annealing temperature and time on AMR in a zero magnetostrictive ferromagnetic amorphous alloy. The AMR effect develops in a very short time at a reasonably high temperature, but is stabilized by annealing for a prolonged time.

  • PDF

Numerical Study on Aerodynamic Performance of Counter-rotating Propeller in Hover Using Actuator Method (Actuator 기법을 이용한 제자리 비행하는 동축 반전 프로펠러 공력 성능에 관한 수치적 연구)

  • Kim, Dahye;Park, Youngmin;Oh, Sejong;Park, Donghun
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.30-44
    • /
    • 2021
  • Experimental investigation of counter-rotating propellers is subject to multiple time and cost constraint because of additional design parameters unlike single propeller. Also, a lot of computing time and resources are required for numerical analysis due to consideration of the interference between the upper and lower propellers. In the present study, numerical simulations were conducted to investigate the hover performance of counter-rotating propellers by using actuator method which is considered to be time-efficient. The accuracy of the present numerical methods was validated by comparing the ANSYS Fluent which is commercial CFD code. The axial spacing and rotational speed were selected as the analysis variables, and the aerodynamic performance was obtained under various conditions. Based on the obtained results, the Figure of Merit (FM) of single propeller and counter-rotating propellers and a prediction factor which enables prediction of counter-rotating propeller performance using a single propeller were derived to evaluate availability of the actuator method.

Signal Change of Normal Saline by Oxygen Injection in FLAIR Image (산소주입에 의한 FLAIR 영상에서 생리식염수의 신호 변화)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.55-63
    • /
    • 2019
  • It was reported that there were some cases in which signal was not inhibited but high signal appeared in cerebrospinal fluid on FLAIR(fluid attenuated inversion recovery) of MRI(Magnetic Resonance Imaging) in case a person inhales high-concentration oxygen. This study was to prepare basic database. We produced a phantom fixed with agar gel and by using it, obtained the images of the signals of normal saline into which oxygen was injected and normal saline diluted with contrast media by changing the TI(Inversion Time) of FLAIR technique and analyzed them. In the result of FLAIR technique of MRI using Philips Achieva MR 3.0T in Busan P Hospital, the SNR(Signal to Noise Ratio) of normal saline into which oxygen was injected was higher than the SNR of normal saline into which oxygen was not injected. However, it was not higher than the SNR of normal saline diluted with contrast media. In the TI 1,800ms, we could obtain the images which do not have the rise of the signal due to oxygen. In the CNR(Contrast to Noise Ratio) of normal saline into which oxygen was injected and normal saline diluted with contrast media as well, it was higher in the TI 1,800ms than in the TI 2,800ms that is mainly used clinically. It is thought that the result of this study could be basic database for studies on change of signal of cerebrospinal fluid as a result of injection of oxygen in FLAIR technique of MRI.

T1-, T2-weighted, and FLAIR Imaging: Clinical Application (T1, T2강조영상, FLAIR영상의 임상 적용)

  • Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • T1-, and T2-weighted imagings and FLAIR (fluid attenuated inversion recovery) imaging are fundamental imaging methods in the brain. T1-weighted imaging is a spin-echo sequence with short TR and short TE and produces the tissue contrast by different T1 relaxation times. In other words, short TR maximizes the difference of the longituidinal magnetization recovery between the tissues. T2-weighted imaging is a spin-echo sequence with long TR and long TE and produces the tissue contrast by different T2 relaxation times. Long TE maximizes the difference of the transverse magnetization decay between the tissues. FLAIR is an inversion recovery sequence using 180 degree inversion pulse. 2500 msec of inversion time is applied to suppress the CSF signal.

  • PDF

Effect of Conditioner Types and Tedding Times on Drying Rate of on Tall Fescue Hay (컨디셔닝 및 반전이 톨 페스큐 건초의 건조율에 미치는 영향)

  • Kim, Ji Hye;Choi, Ki Choon;Kim, Hyeon Seop;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.4
    • /
    • pp.298-302
    • /
    • 2016
  • This study evaluated the effect 3 types of conditioning (Untreated, Impeller, Roller) and the number of times for tedding (rake-teder) performed in one day on the drying rate of tall fescure hay. The experiment was performed at The forage site of Cheonan-si seongwhan-eup National Institute of Animal Sciencee. It took 3 days to make tall fescue hay. The Impeller and Roller conditioning types shortened the haymaking period by 1 day compared to untreated hay. Impeller and roller samples had less than 20% of water content by the $23^{rd}-day$ at 13 o'clock. Tedding frequency failed to affect haymaking. There was no correlation between the three types of conditioning or tedding frequency and acid digestible fiber (ADF), neutral detergent fiber (NDF), total digestible nutrients (TDF), crude protein (CP), or relative feed value (RFV) in tall fescue hay. CP was 12.5~12.9% for the three types of conditioner with 1 or 2 times of tedding a day, Threrfore, conditioner types and gedding frequency had no significant effect on CP.

Magnetization Reversal Behavior of Submicron-sized Magnetic Films in Response to Sub-ns Longitudinal Field Pulses Along the Easy Axis (1 ns 이하의 자화 용이축 펄스 자기장에 의한 자성박막의 자화 반전 거동)

  • Lee, Jin-Won;Han, Yoon-Sung;Lee, Sang-Ho;Hong, Jong-Ill
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.5
    • /
    • pp.188-193
    • /
    • 2007
  • We simulated the magnetization reversal behavior of submicron-thickness magnetic films by applying pulses of sub-ns-long durations and amplitudes along the easy axis. The films were rectangular and elliptical $Ni_{80}Fe_{20}$, and their thickness was 2 nm and 4 nm. We observed different behaviors depending upon the shape and thickness of the films and found a normal non-switching in regions in which we expected complete switching after relaxation. In the elliptical film, the non-switching regions were found to be random and to be widely distributed throughout the switching map. The strong demagnetization field along the z-axis, the film thickness direction, is likely responsible for this abnormal behavior. In the rectangular film, the abnormal non-switching regions were less distributed than they were in the elliptical film due to edge domains resulting from the small $M_z$ or demagnetization field during the switching. Our simulation confirms that large demagnetization is detrimental to the ultra-fast magnetization reversal of magnetic ultra-thin films.

The Effect of Anticholinergic Agents on Postoperative Sore Throat in Patients Undergoing Endoscopic Sinus Surgery (내시경적 부비동 수술 시 항콜린성제제 사용이 수술 후 인후통 발생에 미치는 영향)

  • Lee, Joo-Young;Lee, Deok-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.305-310
    • /
    • 2007
  • Background : After sinus surgery, airway dryness is made worse because patients breathe by mouth. Anticholinergic agents have antisialogogue effects. The airway dryness that occurs after surgery is severe and can increase the incidence of postoperative sore throat. Materials and Methods : One-hundered patients who were scheduled for endoscopic sinus surgery(ESS) were divided into four groups. Each group was premedicated with glycopyrrolate or had no premedication and reversed with glycopyrrolate or atropine. After the surgery the patients were asked about a sore throat and hoarseness postoperatively after 1h, 6h, 12h, 24h, and 48hours, respectively. Results : The incidence of postoperative sore throat and hoarseness was not significantly different among the four groups at any time. Conclusion : The severity of complications after ESS was low and subsided within 24 hours. Therefore, the use of anticholinergic agents does not need to be limited.

  • PDF