• Title/Summary/Keyword: 반응 유동장

Search Result 116, Processing Time 0.024 seconds

Numerical Study on the CO and NO of Rocket Plume as the Type of Water Injection in the Flame Guiding Duct (화염유도로 냉각수 분사방식에 따른 로켓 플룸의 CO와 NO 반응의 수치해석)

  • Kim, Seong-Lyong;Kim, Seung-Han;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.3
    • /
    • pp.39-46
    • /
    • 2015
  • A numerical study has been conducted on CO after burning and NO generation of the rocket plume as the cooling water injected to the rocket plume. The present study shows that the cooling water has a role of increasing the degree of CO after burning and reducing NO generation. However the effect varies as the injection configuration of the cooling water. When the cooling water is injected at the side of the plume, NO generation is dramatically reduced while the degree of CO after burning is relatively low. When the cooling water is injected at the side and the center of the plume, CO after burning is highly increased and NO generation is also dramatically reduced.

Response Analysis of the Slit type Breakwater under Coastal Waves and Flows (연안 파랑과 흐름하에서 슬릿방파제의 반응 해석)

  • Park, Sang-Gil;Lee, Joong-Woo;Kim, Kang-Min;Kang, Sug-Jin;Kim, Suk-Moon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.10a
    • /
    • pp.53-54
    • /
    • 2010
  • 국내에서 소규모 어항의 재개발에 관광객 유치를 위한 친환경적인 기술의 적용이 본격화되고 있다. 항내수질 개선이라는 목적 하에서 외곽시설인 방파제의 선택은 항내 정온과 제체 안정성의 확보가 전제되어야 한다. 따라서 본 연구에서는 친환경방파제인 슬릿방파제의 수리특성을 파악하기 위한 수리모형실험을 수행하고 그 결과를 이용하여 파랑변형 및 유동 실험을 수행하였다. 현장 적용성 확인을 위하여 선정된 구조라항은 우리나라 남해의 소규모 어항으로, SSE, S, SSW파향에 영향을 받는 지역으로, 슬릿방파제를 적용한 결과 제체안정성과 항내 정온도가 확보되는 것으로 나타났다. 이는 슬릿방파제의 특징으로 장주기파의 통과율이 뛰어나다는 점과 소파효과라는 1차적인 목적과 항만 및 연안수역에서 해수교환의 향상이라는 2차적인 목적을 동시에 만족하는 것으로 나타났다.

  • PDF

Thermal and Flow Characteristics of Fluid with Fuel Type and Equivalence Ratio in Flame Spray Process (연료 종류 및 당량비에 따른 Flame Spray 화염장의 열-유동 특성 연구)

  • Lee, Jae Bin;Kim, Dae Yun;Shin, Dong Hwan;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.18 no.4
    • /
    • pp.202-208
    • /
    • 2013
  • The present study aims to investigate the flow characteristics with respect to fuel type and equivalence ratio in the flame spray coating process. The flame spray flow is characterized by much complex phenomena including combustion, turbulent flows, and combined heat transfer. The present study numerically simulated the flam spray process and examined the gas dynamics involving combustion, gas temperature and velocity distributions in flame spray process by using commercial computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). In particular, we studied the effect of fuel type and equivalence ratio on thermal and flow characteristics which could substantially affect the coating performance. From the results, it was found that the gas temperature distributions were varied with different fuels because of reaction times were different according to the fuel type. The equivalence ratio also could change the spatial flame distribution and the characteristics of coated layer on the substrate.

Analysis on the Flow and Heat Transfer in a Large Scale CVD Reactor for Si Epitaxial Growth (Si 선택적 성장을 위한 대형 CVD 반응기 내의 열 및 유동해석)

  • Jang, Yeon-Ho;Ko, Dong Guk;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • In this study, gas flow and temperature distribution in the multi-wafer planetary CVD reactor for the Si epitaxial growth were analyzed. Although the structure of the reactor was simplified as the first step of the study, the three-dimensional analysis was performed taking all these considerations of the revolution of the susceptor and the rotation of satellites into account. From the analyses, a reasonable velocity field and temperature field were obtained. However, it was found that analyses including the upper structure of the reactor were required in order to obtain more realistic temperature results. DCS mole fraction above the satellite surface and the susceptor surface without satellite was compared in order to check the gas species mixing. We found that satellite rotation helped gases to mix in the reactor.

Effects of Ultrasonic Standing Wave on the Ultrasonically-atomized Aerosol Flame Injected through a Slit-jet Nozzle (Slit-jet 노즐을 통과한 초음파 무화 에어로졸 화염에 정상초음파가 미치는 영향)

  • Ahn, Hyun Jong;Kang, Yun Hyeong;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.53-60
    • /
    • 2020
  • In liquid-fuel spray combustion, an experimental study was conducted to observe the effect of ultrasonic excitation on the ultrasonically-atomized liquid fuel flame by controlling pressure field through an ultrasonic standing wave. Flame of the ultrasonically-atomized kerosene aerosol was visualized by using a high speed camera, DSLR, and Schlieren photography. The amount of fuel consumed was obtained by a precise flow-rate measurement technique during combustion, through which the ratio of carrier gas (air) to fuel mass was able to be obtained, too. As a result, it could be found that the combustion reaction-rate of the liquid-fuel aerosol was increased by applying an ultrasonic standing wave to the secondary flame zone of the flame.

Complexity of Groundwater Flow System in a Site Reflected in the Fluctuations of Groundwater Level and Temperature (지하수위와 수온 변동에 나타난 부지 규모 지하수 흐름장의 복잡성)

  • Jonghoon Park;Dongyeop Lee;Nam C. Woo
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.563-570
    • /
    • 2022
  • This study was objected to show the complexity of groundwater flow system in a site-scale area as a design parameter of the groundwater monitoring network for early detection of pollutant leakage from a potential source of groundwater contamination (e.g., storage tank). Around the tanks, three monitoring wells were installed at about 22~25 m deep and groundwater level and temperature had been monitored for 22 months by 2-minute interval, and then compared with precipitation and temperature data from nearby weather station. Annual variation of groundwater level and its response to precipitation event, variation of groundwater temperature and delayed response to that of atmospheric temperature indicate the complexity of groundwater flow and flow paths even in the relatively small area. Thus, groundwater monitoring network for early detection of contaminant leakage should be designed with full consideration of the complexity of groundwater flow system, identified from the detailed hydrogeological investigation of the site.

A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter (반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(I))

  • Kwon, Young-Hyun;Kim, Jin-Uk;Jung, Yu-Jin;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4656-4663
    • /
    • 2010
  • In this study, the 3D computational fluid dynamics (CFD) was performed in relation to the internal fluid characteristics, flow distribution, air mean ages, and residence time for the development of the most optimal model in the complex post-disposal device. As it is expected that a channeling (drift) would be made by the semi-dry reactor due to the large difference in the flow distribution by the compartment in the bag filter, a structural improvement should be urgently made for more uniformed flow distribution in the bag filter. In addition, it showed the possibility that the velocity field and distribution characteristics of the residence time could be improved through a modification to inlet structure of the spray dryer reactor. The complex post-disposal device, modified and supplemented with this analysis, integrated the semi-dry reactor and the bag filter in a single body, so it follows that the improvement can make the device compact, the installation area, the operation fee, and management more convenient.

Analysis of Harbor Responses due to the Dredging Work at Waterway and Mooring Basin in Busan New Port (부산 신항만에서 수로 및 박지 준설에 따른 항만정온도의 변화 분석)

  • Lee Joong-Woo;Lee Hak-Seung;Lee Hoon;Yang Sang-Yong
    • Journal of Navigation and Port Research
    • /
    • v.30 no.1 s.107
    • /
    • pp.97-104
    • /
    • 2006
  • Recently the first stage qf construction for Busan new port emerged over the sea surface at the north container terminal site. With this, there are lot of discussions and debates on increasing the water depth at the approaching channel and mooring basin from the existing 15m to 18m by dredging work in order to be able to serve 12,000TEU containership, and at the same time, correction to the reclamation plan of hinterland at the part of Undong Bay qf the new port site. Since the attack of typhoon 'Maemi' in 2003, it is expected that the design wave parameters for coastal and harbor structures in this area would be somewhat changed and so the extreme wave condition at each terminal and tranquility of berthing area does, and therefore, it is necessary to analyze the tranquility at each berth Hence in this study, we constructed a wave model for these conditions and performed simulation together with the circulation model simulation, compared with the field data collected The result showed the increase of the harbor response throughout the basin but not severe condition However, a certain location needs to be prepared for the rough sea condition when a severe typhoon hit the site.

Analysis of Harbor Responses due to the Dredging Work at Waterway and Mooring Basin in Busan New Port (부산 신항만에서 수로 및 박지 준설에 따른 항만정온도의 변화 분석)

  • Lee Joong-Woo;Lee Hak-Seung;Lee Hoon;Yang Sang-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.117-124
    • /
    • 2005
  • Recently the first stage of construction for Busan new port emerged over the sea surface at the north container terminal site. With this, there are lot of discussions and debates on increasing the water depth at the approaching channel and mooring basin from the existing 15m to 18m by dredging work in order to be able to serve 12,000TEU containership, and at the same time, correction to the reclamation plan of hinterland at the part of Undong Bay of the new port site. Since the attack of typhoon 'Maemi' in 2003, it is expected that the design wave parameters for coastal and harbor structures in this area would be somewhat changed and so the extreme wave condition at each terminal and tranquility of berthing area does, and therefore, it is necessary to analyze the tranquility at each berth. Hence in this study, we constructed a wave model for these conditions and performed simulation together with the circulation model simulation, compared with the field data collected. The result showed the increase of the harbor response throughout the basin but not severe condition. However, a certain location needs to be prepared for the rough sea condition when a severe typhoon hit the site.

  • PDF

Synthesis of Hectorite by Hydrothemal Method (저온 수열법에 의한 헥토라이트 합성)

  • Jang, Young-Nam;Chae, Soo-Chun;Ryu, Gyoung-Won;Kim, You-Dong;Jang, Hee-Dong;Bae, In-Kook
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.1 s.51
    • /
    • pp.1-6
    • /
    • 2007
  • Hectorite was synthesized by a two-step hydrothermal process from $Mg(OH)_{2}$, water glass (${\sim}30\;wt%\;SiO_{2}$) and Li-compound at $90{\pm}5^{\circ}C$. The product shows excellent dispersion and swelling properties. The mixture of the starting materials was heated in a glass vessel for the first reaction with continuous stirring and the pH of the solution was adjusted to $6{\sim}8$, resulting in the formation of a precursor of hectorite. The excess salt components were washed out from the resulting slurry and then was matured in the glass vessel for the 2nd reaction. Li compound was added during the reaction. After a 10 h retention, the gel of hectorite was formed. The XRD pattern of the synthesized one was coincided with that of natural hectorite and SEM study revealed uniform grains 50 m in diameter. The d001 basal spacing of the product moved from 12 to $17.4\;{\AA}$ after glycolation treatment. The measured value of CEC and the swelling capacity was 90 cmol/kg and $60{\sim}70\;mL/2\;g$, respectively.