• Title/Summary/Keyword: 반응 수정 계수

Search Result 91, Processing Time 0.026 seconds

Evaluation of Response Modification Factors for Shear Wall Apartment Building (벽식 APT의 반응수정계수 추정에 관한 연구)

  • 송정원;송진규;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.859-864
    • /
    • 2001
  • For earthquake resistance design, a response modification factor is used to reduce the design strength and it reflects ductility, reserve strength, redundancy and damping effect. But this factor has not theoretical basis. In this study, two response modification factors are compared and analyzed for shear wall apartment building.; the one is introduced by ATC-19 Procedures, the other is suggested FEMA-273 and ATC-40 through nonlinear static analysis. For the results, ATC-19 procedure gives a reasonable estimation to R factor. But $R_{u}$ by using FEAM-273 and ATC-40 methods is estimated so small in case of a minor or moderate earthquake region. Due to this fact, response modification factor is smaller than suggested load criterion 3.0. So, it needs to decrease wall volume and reduce the global strength and system stiffness for proper ductile behavior matching to domestic load criterion.

  • PDF

우리나라에서의 PC 구조물의 내진 성능 실험

  • Jung, Ran;Kim, Woo;Jung, Ha-Sun;Lee, Han-Sun
    • Computational Structural Engineering
    • /
    • v.3 no.3
    • /
    • pp.30-38
    • /
    • 1990
  • 본 실험은 지금까지 우리나라에서 수행 되어온 기존, 건축 토목관계 실험의 수준을 한차원 높히는데 크게 기여하리라 생각된다. Hydraulic Jack을ㄹ 이용한 1 방향 실험과는 비교할 수 없을 정도로 자동화, 기계화를 이루었으며, 실험에 사용된 Actuator는 미국의 MTS사 제품으로 빠른 속도 (2Hz에서 최대 +/-7.5cm Stroke)로 움직이는 반복 주기 하중을 컴퓨터가 제어하고 Data를 자동적으로 컴퓨터에 기록하므로 구조물의 동적특성까지를 규명하는데 필수적인 장비이다. 또한 Shaking table은 실제로 발생하는 지진파를 그대로 입력시켜 구조물에 대한 내진 성능을 완벽하게 측정할 수 있다. 특히 구조설계자들 사이에도 논란이 되고 있는 우리나라 내진규준의 R factor(반응수정계수)를 정하는데 매우 유효한 역할을 하리라 기대된다.

  • PDF

Response Modification Factor and Deformability for Structural Walls Designed with Different Details (구조 상세가 다른 벽체의 변형성능과 반응수정계수)

  • 오영훈;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.959-964
    • /
    • 2001
  • This study investigates the seismic performance of bearing walls with rectangular sectional shape and specific details of reinforcements developed for 10 to 20-story apartment buildings in Korea. To investigate seismic behavior of structural walls, several specimens were experimented by author and laboratory test results by other researchers were collected and analysed. Structural behaviors of walls were evaluated by means of ductility, deformation, and strength capacities. For this purpose, thirty six specimens having different Properties such as aspect ratios and details were considered. Based on the results of this study, deformability of the walls with specific details is discussed. Also this study compares the response modification factor(R) for the bearing wall systems in seismic design provisions between Korea and United States.

  • PDF

Evaluation of Response Modification Factore for Earthquake Resistant Design of Moment-Resisting Steel Frames (모멘트-연성 강구조물의 내진설계를 위한 반응수정계수의 평가)

  • 송종걸
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.201-208
    • /
    • 1997
  • In most seismic codes such as the Uniform Building Code(UBC), the response modification factor(or the force reduction factor)is used to reflect the capability of a structure in dissipating energy through inelastic behavior. The response modification factor is assigned according to structural system type. Ductile systems such as special moment-resisting steel frames are assigned larger values of the response modification factor, and are consequently designed for smaller seismic design forces. Therefore, structural damage may occur during a severe earthquake. To ensure safety of the structures, the suitability of the response modification factor used in aseismic design procedures shall be evaluated. The object of this study is to develop a method for the evaluating of the response modification factor. The validity of the evaluating method has been examined for several cases of different structures and different earthquake excitations.

  • PDF

Effect of Stiffness and Strength Degrading Model on Evaluating the Response Modification Factor (강성 및 강도저하 모델이 반응수정계수 산정에 미치는 영향 평가)

  • 오영훈;한상환;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.25-32
    • /
    • 1998
  • Most recent seismic design codes include Response Modification Factor(RMF) for determining equivalent lateral forces. The RMF is used to reduce the linear elastic design spectrum to account for the energy dissipation capacity, overstrength and damping of the structure. In this study the RMF is defined as the ratio of the absolute maximum linear elastic base shear to the absolute maximum nonlinear base shear of a structure subject to the same earthquake accelerogram. This study investigates the effect of hysteretic model, as well as target ductility ratio and natural period on duct based RMF using nonlinear dynamic analyses of the SDOF systems. Special emphasis is given to the effects of the hysteretic characteristics such as strength deterioration and stiffness degradation. Results indicate that RMFs are dependent on ductility, period and hysteretic model.

  • PDF

Performance Evaluation of Steel Moment Frame Buildings with Different Response Modification Factors (반응수정계수의 영향에 따른 철골조 빌딩의 내진 성능 평가)

  • Lee, Ki-Hak
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.201-208
    • /
    • 2006
  • This study lotuses on the seismic behavior of 3-, 9-, and 20-story steel moment resisting frame (MRF) structures designed in accordance with the 2000 International Building Code using different Response Modification factors (R factors) 8, 9, 10, 11, and 12. For a detailed case study, 30 different structures were evaluated for twenty ground motions representing the hazard level which is equal to a 2% probability exceeding in 50 years (2% in 50 years). The results showed that the current R factors provide conservative designs for the 3- and 9-story buildings for the Collapse Prevention performance objective. However, the 20-story buildings designed without using the minimum requirement of spectral acceleration CS prescribed in the IBC 2000 did not satisfy the seismic performance for Collapse Prevention performance.

  • PDF

Development of Preventive Self-Management Knowledge Related to Premature Labor (PSMK-PL) Scale for Women of Childbearing Age : An Item Response Theory Approach (가임 여성의 조기진통에 대한 예방적 자가관리 지식 측정 도구 개발: 문항반응이론 적용)

  • Kim, Sun-Hee;Lee, Yu-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.9
    • /
    • pp.439-450
    • /
    • 2022
  • Purpose: This study was to develop the Preventive Self-Management Knowledge related to Premature Labor (PSMK-PL) scale for women of childbearing age. Methods: Preliminary items were developed based on the literature and interview results of those who experienced premature labor. The online survey was conducted and the data of 250 women were analyzed using the DIMTEST and DETECT programs by applying the item response theory. Internal consistency reliability was analyzed with Cronbach's alpha (95% CI). Results: Among the 30 preliminary items, six items were deleted. The difficulty and discrimination of the 24 final three-dimensional scales were all acceptable, respectively. Cronbach's alpha (95% CI) was .89 (.87~.91). Conclusion: The PSMK-PL scale generally consisted of items with validity, and the reliability was acceptable.

Study of Ultrasonic Nonlinearity in Heat-Treated Material (열처리된 재료의 초음파 비선형성에 관한 연구)

  • Li, Weibin;Lee, Jae-Sun;Cho, Youn-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.751-756
    • /
    • 2010
  • Ultrasonic nonlinearity is very sensitive to changes in material properties. This paper describes the study of the correlation between heat treatment and ultrasonic nonlinearity by taking nonlinear factors into consideration. A modified formula was proposed for ultrasonic velocity. This formula indicated that the changes occurring in nonlinearity during heat treatments cause changes in the ultrasonic velocity. The experimental results show that the relative nonlinearity parameters calculated from the modified ultrasonic velocities and the ratio of amplitudes of the second harmonic and fundamental wave are in good agreement. The experimental results prove that heat treatment can result in changes in material nonlinearity. Moreover, the relative nonlinearity parameter calculated from the modified velocity formula is has a large value. Since this parameter has high sensitivity to changes in nonlinearity, it can be used to represent the relative nonlinearity change calculated in this study by using the modified formula for ultrasonic velocity.

Incheon's Import Behaviors of the Major Items (인천항 주요품목의 수입행태)

  • Lim, Jun-Hyung
    • Journal of Korea Port Economic Association
    • /
    • v.23 no.4
    • /
    • pp.228-243
    • /
    • 2007
  • This study porvides an empirical overview of the import patterns of Incheon port using an Engle-Granger cointegration technique and Johansen's multivariate cointegraion methodology test to check the stationarity of the model. The empirical results show that the import in Incheon port related to the economic variables. This paper also applies rolling regression to our model, indicating that import are endogeneous to the economic variable.

  • PDF

The Effects of Phenol on Biokinetic Coefficient of Multiple Phenol Derivatives of 2,4-Dichlorophenol and 2,4-Dinitrophenol in Activated Sludge Process (활성슬러지공정에서 페놀이 2,4-디클로로페놀과 2,4-디니트로페놀을 함유한 복합페놀폐수의 미생물분해계수에 미치는 영향)

  • Lim, Gye-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.349-353
    • /
    • 1999
  • A study was carried out to see the effects of phenol on the biological degradation of a wastewater containing 2,4-dichlorophenol and 2,4-dinitrophenol and the biodegradation kinetic coefficients of Eckenfelder's modified model for the activated sludge process. The system containing base mix (BM) which was formulated with essential energy sources and nutrients was run down and washed out when 2,4-dichlorophenol and 2,4-dinitrophenol was introduced into the base mix unit without acclimation to phenol. Whereas for the system acclimated to phenol, the treatment efficiency was 91.9% in terms of $BOD_5$ and treatability for each chemical of phenol, 2,4-dichlorophenol, and 2,4-dinitrophenol was 99.8%, 43.3% and 62.5% based on concentration, respectively. Additional BM was added into the combined unit containing phenol, 2,4-dichlorophenol, 2,4-dinitrophenol so that the better treatment efficiency was achieved for each compound. The biokinetic coefficient of Eckenfelder's modified model without phenol acclimation was not estimated because the system did not reach the steady state. Thc coefficient for the phenol acclimation was 12.44 /day, however it was changed as 46.91 /day in addition of both of phenol acclimation and 47 mg/l of BM. The results presented above could be useful for the process design and further study in the field of biodegradation of benzene derivatives.

  • PDF