• Title/Summary/Keyword: 반응 깊이 측정

Search Result 109, Processing Time 0.024 seconds

Defect Detection of the Wall Thinning Pipe of the Nuclear Power Plant Using Infrared Thermography (적외선열화상을 이용한 원자력발전소 감육 배관의 결함 검출)

  • Kim, Kyeong-Suk;Chang, Ho-Sub;Hong, Dong-Pyo;Park, Chan-Joo;Na, Sung-Won;Kim, Kyung-Su;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • The infrared energy is emitted in the infrared wavelength range that corresponds to the surface temperature of a object which has temperature that is over the absolute the temperature(OK). The infrared thermography (IRT) is a non-destrnctive testing method that provides thermal video for the user in real-time by converting the infrared quantity that is detected by the infrared detector into temperature. The pipes of nuclear power plant(NPP) could be thinned by the corrosion and fatigue and the defect could lead to a big accident. For this reason, the effective non-destructive testing method is necessary. In this study, the relationship between the measured temperature and the defect depth or size of NPP pipes were recognized and that was applied to detect the wall thinning defects of NPP pipes.

Feasibility Test on Automatic Control of Soil Water Potential Using a Portable Irrigation Controller with an Electrical Resistance-based Watermark Sensor (전기저항식 워터마크센서기반 소형 관수장치의 토양 수분퍼텐셜 자동제어 효용성 평가)

  • Kim, Hak-Jin;Roh, Mi-Young;Lee, Dong-Hoon;Jeon, Sang-Ho;Hur, Seung-Oh;Choi, Jin-Yong;Chung, Sun-Ok;Rhee, Joong-Yong
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.93-100
    • /
    • 2011
  • Maintenance of adequate soil water potential during the period of crop growth is necessary to support optimum plant growth and yields. A better understanding of soil water movement within and below the rooting zone can facilitate optimal irrigation scheduling aimed at minimizing the adverse effects of water stress on crop growth and development and the leaching of water below the root zone which can have adverse environmental effects. The objective of this study was to evaluate the feasibility of using a portable irrigation controller with an Watermark sensor for the cultivation of drip-irrigated vegetable crops in a greenhouse. The control capability of the irrigation controller for a soil water potential of -20 kPa was evaluated under summer conditions by cultivating 45-day-old tomato plants grown in three differently textured soils (sandy loam, loam, and loamy sands). Water contents through each soil profile were continuously monitored using three Sentek probes, each consisting of three capacitance sensors at 10, 20, and 30 cm depths. Even though a repeatable cycling of soil water potential occurred for the potential treatment, the lower limit of the Watermark (about 0 kPa) obtained in this study presented a limitation of using the Watermark sensor for optimal irrigation of tomato plants where -20 kPa was used as a point for triggering irrigations. This problem might be related to the slow response time and inadequate soil-sensor interface of the Watermark sensor as compared to a porous and ceramic cup-based tensiometer with a sensitive pressure transducer. In addition, the irrigation time of 50 to 60 min at each of the irrigation operation gave a rapid drop of the potential to zero, resulting in over irrigation of tomatoes. There were differences in water content among the three different soil types under the variable rate irrigation, showing a range of water contents of 16 to 24%, 17 to 28%, and 24 to 32% for loamy sand, sandy loam, and loam soils, respectively. The greatest rate increase in water content was observed in the top of 10 cm depth of sandy loam soil within almost 60 min from the start of irrigation.

Application of Geophysical Methods to Detection of a Preferred Groundwater Flow Channel at a Pyrite Tailings Dam (황철석 광산 광미댐에서의 지하수흐름 경로탐지를 위한 물리탐사 적용)

  • Hwang, Hak Soo
    • Economic and Environmental Geology
    • /
    • v.30 no.2
    • /
    • pp.137-142
    • /
    • 1997
  • At the tailings dam of the disused Brukunga pyrite mine in South Australia, reaction of groundwater with the tailings causes the formation and discharge of sulphuric acid. There is a need to improve remediation efforts by decreasing groundwater flow through the tailings dam. Geophysical methods have been investigated to determine whether they can be used to characterise variations in depth to watertable and map preferred groundwater flow paths. Three methods were used: transient electromagnetic (TEM) soundings, direct current (DC) soundings and profiling, and self potential (SP) profiling. The profiling methods were used to map the areal extent of a given response, while soundings was used to determine the variation in response with depth. The results of the geophysical surveys show that the voltages measured with SP profiling are small and it is hard to determine any preferred channels of groundwater flow from SP data alone. Results obtained from TEM and DC soundings, show that the DC method is useful for determining layer boundaries at shallow depths (less than about 10 m), while the TEM method can resolve deeper structures. Joint use of TEM and DC data gives a more complete and accurate geoelectric section. The TEM and DC measurements have enabled accurate determination of depth to groundwater. For soundings centred at piezometers, this depth is consistent with the measured watertable level in the corresponding piezometer. A map of the watertable level produced from all the TEM and DC soundings at the site shows that the shallowest level is at a depth of about 1 m, and occurs at the southeast of the site, while the deepest watertable level (about 17 m) occurs at the northwest part of the site. The results indicate that a possible source of groundwater occurs at the southeast area of the dam, and the aquifer thickness varies between 6 and 13 m. A map of the variation of resistivity of the aquifer has also been produced from the TEM and DC data. This map shows that the least resistive (i.e., most conductive) section of the aquifer occurs in the northeast of the site, while the most resistive part of the aquifer occurs in the southeast. These results are interpreted to indicate a source of fresh (resistive) groundwater in the southeast of the site, with a possible further source of conductive groundwater in the northeast.

  • PDF

정전구동 방식의 연동형 마이크로펌프의 제작

  • Hong, Pyo-Hwan;Jeong, Dong-Geon;Gong, Dae-Yeong;Pyo, Dae-Seung;Lee, Jong-Hyeon;Lee, Dong-In;Jo, Chan-Seop;Kim, Bong-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.448-448
    • /
    • 2013
  • 최근 생물학적 분석 기구에서 시료를 처리, 분리, 검출, 샘플링 또는 분석하기 위해 사용되는 마이크로펌프(Micropump)에 대한 관심이 높아지고 있다. 또한 전자소자의 성능과 신뢰성의 증진을 위한 전자소자의 열 문제를 해결하기 위해 냉각장치로 마이크로 펌프가 적용되기도 한다. 그 외에도 마이크로펌프는 다양한 분야에 응용이 가능하다. 마이크로펌프는 작동 방식에 따라 압전형, 공압형, 열공압형, 연동형 등의 여러 종류로 분류되고 있다. 그중에서도 최근에는 연동형 마이크로 펌프의 개발이 각광받고 있다. 기존의 연동형 펌프들은 다중 챔버를 가지고 있으며, 각각의 챔버 내에서 Dead volume이 많이 발생할 뿐만 아니라 이상적인 연동운동과는 차이가 많이 나는 문제점을 가지고 있다. 또한 압전방식과 열공압방식은 느린 응답성으로 인해 효율적인 유체 이동이 어렵다. 본 논문에서는 이상적인 연동운동을 구현하기 위하여 기존의 연동형 펌프의 단점을 보완하고, 하나의 챔버에 다중전극 구조를 가지는 정전기력방식의 연동형 펌프를 개발하였다. 정전기력방식으로 펌프를 구동함으로써, 저전력으로 펌프구동이 가능하며, 하나의 챔버에 다중전극을 설치함으로써 이상적인 연동운동을 재현하였다. 그리고 Dead volume을 최소화 하였다. 또한, 빠른 반응속도로 인해 효율적인 유체 이동을 실현시킬 수 있었다. 본 연구에서 제안된 마이크로 펌프의 구성은 크게 챔버, 박막, Inlet/outlet hole으로 구성되었다. 챔버는 Si-wafer에 wet etching 공정으로 제작 하였고 그 위에 알루미늄 박막을 200 nm 증착시켰다. 챔버는 가로 32 mm, 세로 5 mm, 깊이는 $15{\mu}m$, 부피는 $200{\mu}l$으로 제작되었다. 박막은 폴리이미드(polyimide)를 사용하여 $3{\mu}m$의 두께로 제작 되었으며, 폴리이미드 박막 사이에는 200 nm 두께의 4개의 알루미늄 박막 전극을 삽입시켰다. 삽입된 4개의 전극에 개별적인 전기신호를 보냄으로써 연동운동이 가능하다. Inlet/outlet hole은 직경 2 mm의 크기로 제작되었으며, 튜브를 연결하여 유체가 흐를 수 있는 체널을 형성하였다. 제작된 마이크로 펌프의 구동전압은 115 V이며, 인가되는 주파수를 1 Hz~100 KHz까지 변화시켜 유량을 측정하였다. 작동 유체는 공기이며, 유량측정은 튜브 내에 물방울을 삽입하여 시간에 따른 이동거리를 관측하였다. 측정결과 2.2 KHz에서 2.4 mm/min의 가장 높은 유량을 확인할 수 있었다. 본 연구를 통해 제안된 연동형 마이크로펌프는 이상적인 연동운동이 가능함으로써 기존의 연동형 방식의 문제점을 보완하였으며, 생명과학, 의학, 화학 등의 분야에서 적용이 가능하리라 기대된다.

  • PDF

The Development of a Cryotherapy System (한냉물리치료기의 개발)

  • Kim, Yeong-Ho;Yang, Gil-Tae;Jang, Yun-Hui;Park, Si-Bok;Ryu, Jin-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.617-622
    • /
    • 1998
  • A cryotherapy system using cold air was developed. The developed system had superior low-temperature characteristics with various flow rates and nozzle sizes, and used R-404A, as a coolant, which has no destructive effects of Ozone layers. Flow rates and the treatment time can be easily altered during the operation. In addition, and alarm system was designed for the overload, overheat, and over-charge of the machine. For clinical applications, skin temperatures, intra-articular temperatures of the knee joint and intra-muscluar temperatures of the gluteal muscles were measured during and after the cryotherapy. After a 5-minute therapy, skin and intra-articular temperatures decreased by $23.3{\pm}4.7 and 4.1 {\pm}1.0^{circ}C$, respectively. A 5-minute cryotherapy was good enough to maintain low intra-articular temperatures for 2-3 hours. Resting intra-muscular temperatures in 2, 4, and 6cm deep in the gluteal muscle were $36.5{\pm}1.2, 36.9{\pm}0.2, 37.1{\pm}0.2^{circ}C$, respectively (p<0.05). Lowest temperatures in 2, 4, and 6cm depth were $35.1{\pm}0.7, 36.2{\pm}0.4, 36.9{\pm}0.3^{circ}C$, respectively (p<0.05). Temperatures after a 2-hour cold air application on the skin and in the muscle in dept도 of 2, 4, and 6cm were $32.2{\pm}1.1, 36.2{\pm}0.5, 36.6{\pm}0.3, 36.9{\pm}0.3^{circ}C$respectively (p<0.05). Temperatures on the skin and in the muscle significantly decreased after 2 hours, compared with before cold air application (p<0.05). The intra-muscular temperature was changed more slowly than the skin temperature, and the deeper the muscle, the lesser temperature changes. The effect of a 5-minute cold air application lasts up to 2 hours, and it seems that the rebound-rise of the temperature dut to the reactive vasodilatation does not occur in the gluteal muscle.

  • PDF

GEOMETRIC NINLINEAR ANALYSIS OF UNERGROUND LAMINATED COMPISITE PIPES (기하학적 비선형을 고려한 지하매설 복합재료 파이프의 해석)

  • 김덕현;이인원;변문주
    • Computational Structural Engineering
    • /
    • v.2 no.1
    • /
    • pp.65-70
    • /
    • 1989
  • An analytical study was conducted using the Galerkin technique to determine behaviour of thin fibrereinforced and laminated composite pipes under soil pressure. Geometric nonlinearity and material linearity have been assumed. It is assumed that vertical and lateral soil pressure are proportional to the depth and lateral displacement of the pipe respectively. It is also assumed that radial shear stress is negligible because the ratio of thickness to the radius of pipe is very small. The above results are verified by the finite element analysis.

  • PDF

Preliminary Investigations of the Dosimetric Properties of a Normoxic Polymethacrylic Acid Gel Dosimeter Using a Respiration-Motion Simulator (호흡모의움직임장치를 이용한 정상산소 폴리메타크릴산 겔 선량계의 선량특성)

  • Park, Chae Hee;Cho, Yu Ra;Cho, Kwang Hwan;Park, Ji Ae;Kim, Kyeong Min;Kim, Kum Bae;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.138-144
    • /
    • 2012
  • Dose distribution throughout the clinical organ range of motion was analyzed using a respiratory-motion simulator that was equipped with a polymer gel dosimeter and EBT2 film. The normoxic polymer gel dosimeter was synthesized from gelatin, MAA, HQ, THPC and HPLC. The gel dosimeter and EBT2 film were irradiated with Co-60 gamma rays that were moved along the x-axis and y-axis in ${\pm}1.5cm$ steps at five-second intervals. The field size was $5{\times}5cm^2$. The SSD was 80 cm and set to 10 Gy at a depth of 2 cm. The PDD at a depth of 50 mm was 75.2% in the ion chamber, 82.3% in the static state and 86.1% in the dynamic state in the gel dosimeter. The penumbra for the dynamic state target, which was measured using the gel dosimeter, averaged 10.89 mm, this is a 40.5% increase over the penumbra of the static state target of 7.74 mm. In addition, when measuring with gel dosimetry, the value for the penumbra is 36.6% smaller in the static state and 29.4% smaller in the dynamic state compared to measuring with film. The aim of this study was to investigate the dosimetric properties of a normoxic polymethacrylic acid gel dosimeter in static and dynamic states and to evaluate the potentiality as a relative dosimeter for dynamic therapeutic radiation.

Geochemical Characterization of Rock-Water Interaction in Groundwater at the KURT Site (물 암석 반응을 고려한 KURT 지하수의 지구화학적 특성)

  • Ryu, Ji-Hun;Kwon, Jang-Soon;Kim, Geon-Young;Koh, Yong-Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.3
    • /
    • pp.189-197
    • /
    • 2012
  • Geochemical composition of fracture filling minerals and groundwater was investigated to characterize geochemical characteristics of groundwater system at the KURT site. Minerals such as calcite, illite, laumontite, chlorite, epidote, montmorillonite, and kaolinite, as well as I/S mixed layer minerals were detected in the minerals extracted from the fracture surfaces of the core samples. The groundwater from the DB-1, YS-1 and YS-4 boreholes showed alkaline conditions with pH of higher than 8. The electrical conductivity (EC) values of the groundwater samples were around $200{\mu}S/cm$, except for the YS-1 borehole. Dissolved oxygen was almost zero in the DB-1 borehole indicating highly reduced conditions. The Cl- concentration was estimated around 5 mg/L and showed homogeneous distribution along depths at the KURT site. It might indicate the mixing between shallow groundwater and deep groundwater. The shallow groundwater from boreholes showed $Ca-HCO_3$ type, whereas deep groundwater below 300 m from the surface indicated $Na-HCO_3$ type. The isotopic values observed in the groundwater ranged from -10.4 to -8.2‰ for ${\delta}^{18}O$ and from -71.3 to -55.0‰for ${\delta}D$. In addition, the isotope-depleted water contained higher fluoride concentration. The oxygen and hydrogen isotopic values of deep groundwater were more depleted compared to the shallow groundwater. The results from age dating analysis using $^{14}C$ indicated relatively younger (2000~6000yr old) groundwater compared to other european granitic groundwaters such as Stripa (Sweden).

Soil Carbon and Microbial Activity Influenced by Pasture and Rice Paddy Management (목초재배지 및 벼논 관리 변화에 따른 토양 탄소 및 미생물 활성도)

  • Yoo, Ga-Young;Kim, Hyun-Jin;Kim, Ye-Sol;Jung, Min-Hung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.3
    • /
    • pp.435-443
    • /
    • 2012
  • This study investigated soil carbon storage and microbial activities influenced by different management practices in rice paddies and pastures. Soils under a single-crop farming of rice (CON) and rice-Italian ryegrass rotation farming (IRG) were compared in Jangheung, Jeollanam-do, Seocheon and Cheonan, Chungcheongnam-do. Soils from pastures were analyzed to investigate the effect of duration period (P1, P2, P3) in Namwon, Jeollabuk-do and Seosan, Chungcheongnam-do. In rice paddy, total and particulate carbon (PC) concentrations in the IRG soils were significantly higher than those in the CON soils both in Jangheung and Seocheon where the IRG has been established for three years, whereas carbon concentrations were not significantly different in Cheonan where IRG planting history is only one year. In rice paddy soils, PC was suggested as an early indicator to monitor changes in soil carbon storage followed by adopting different management practices. In pasture, total and PC concentrations increased with duration period especially in the 0-5 cm soils. Contrary to the rice paddy soils, the magnitude of change in PC concentration is not as great as that in total carbon concentration, implying that there is a need to develop a new early indicator other than PC using different fractionation scheme. The soil carbon storage in pasture also increased with years since establishment and the increasing rate was significantly greater in the early stage (0-5 yrs) than the later one (> 5 yrs). Microbial activities measured from fluorescein diacetate (FDA) hydrolysis analysis were significantly lower in the IRG soils than CON soils, whereas no difference was observed in the pastures of different ages. This shows that FDA activity is not a sensitive indicator to differentiate soil qualities influenced by management practices if it is used by itself.

Growth Performances and Physiological Responses of Quercus spp. and Fraxinus rhynchophylla Subjected to Different Soil Moisture Regimes and Nutrition Levels (수분(水分) 및 양료(養料) 처리(處理)에 따른 참나무류와 물푸레나무의 생장 및 생리 반응)

  • Kwon, Ki Won;Lee, Jeoung Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.2
    • /
    • pp.164-174
    • /
    • 1994
  • Temporal changes in growth performances, chlorophyll contents, and tissue water relations for determining their physiological responses of five economic tree species subjected to chronic water and nutrition stresses were investigated with containerized seedlings grown in different soil moisture regimes and nutrition levels. Seedlings of Quercus acutissima, Q. variabilis, Q. mongolica, Q. serrata, and Fraxinus rhynchophylla were propagated in plastic pots(I.D. $16cm{\times}Depth$ 16cm) for the experiments. The seedlings were subjected to two soil moisture regimes of dry and wet soils and two nutrition levels of fertilization with N+P+K and no fertilization through the growing season from May to September in a green house. For the purpose of analyzing their responses to the environmental stresses, seedling heights and root collar diameters, chlorophyll contents, and P-V curve parameters of the seedlings were measured in May, July, and September. The environmental stresses coming from moisture and nutrient deficits affected the growth performances of seedlings variously among species and among different growing periods, as well as between height and basal diameter growth of seedlings. The growth performances of Q. acutissima were influenced sensitively on the stresses, but those of Q. mongolica less influenced in comparison with other species. Chlorophyll contents were generally higher in Quercus spp. than F. rhynchophylla through the growing season. The chlorophyll contents changed by species and by treatment through the season within ranges of 0.14~1.96 mg/g dry wt. of chlorophyll a and within 0.16~1.79mg/g dry wt. of chlorophyll b, respectively. But the contents seemed to be decreased gradually through the chronic environmental stresses and leaf senescence. The osmotic potential at full turgor(${\Psi}{{\pi}o}$) and turgor loss point(${\Psi}{\pi}p$) had temporarily declined up to 3 to 5bars from -7.0~-12.4bars in May to -10.2~-17.5bars in September and up to 5 to 6bars from -7.6~-14.2bars in May to -12.9~-20.4bars in September, respectively, with some exceptions. The values of ${\Psi}{\pi}p$ were generally high in F. rhynchophylla in May and July, but high in Q. serrata in September. Relative water contents at turgor loss point(RWCp) were generally high in F. rhynchophylla, but the temporal changes of RWCp were quite and frequently different among species and among treatment.

  • PDF