• Title/Summary/Keyword: 반응매질

Search Result 178, Processing Time 0.025 seconds

Removal of Heavy Metal and Phenol from Aqueous Solution Using Fe(III) loaded Adsorbent (3가철 함유 흡착제를 이용한 수용액상의 중금속 및 페놀제거연구)

  • Kim, Seok-Jun;Kim, Won-Gee;Lee, Seung-Mok;Yang, Jae-Kyu;Lee, Nam-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.541-548
    • /
    • 2009
  • Iron coated media (activated carbon, sand and starfish) were prepared at pH 4 and applied for the treatment of landfill leachate containing organic compounds and soluble metal ions such as $Zn^{2+},\;Cu^{2+},\;Mn^{2+}$ in batch and column experiment. The amount of iron coated in media was analyzed with EPA 3050B method. The removal efficiency of metal ions and phenol was compared with iron coated media. The amount of iron coated in Fe-AC and ICS(iron coated sand) were 1,612 mg/kg and 1,609 mg/kg, respectively, while it was higher with 1,768 mg/kg in ICSF(iron coated starfish). The result of batch study represent the highest removal efficiency in the treatment of wastewater using iron coated starfish. In column study, the removal efficiency of phenol and metal ions was higher in multi-layered system of ICS, Fe-AC and ICSF compared to single layered system. Breakthrough time in the effluent was relatively enhanced for $Cu^{2+}$ and $Zn^{2+}$ in multi-layered system while the removal efficiency of $Mn^{2+}$ were not varied much. Therefore, multi-layered system was identified as the better system for the treatment of wastewater containing of metal ions and organic compound.

Effects of Dissolved Compounds in Groundwater on TCE Degradations Reaction by Nanoscale Zero-Valent Iron (나노영가철의 TCE 분해반응 시 지하수 용존물질의 영향)

  • Kim, Tae-Ho;Kim, Hong-Seok;Lee, Jin-Yong;Cheon, Jeong-Yong;Lee, Kang-Kun;Hwang, In-Seong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.6
    • /
    • pp.413-419
    • /
    • 2011
  • Nanoscale zero-valent iron (NZVI) particles were tested as remediation media for groundwater contaminated by organic pollutants (e.g., TCE, trichloroethylene). The contaminated groundwater contained anions ($NO_3^-$, $Cl^-$, $SO_4^{2-}$, and $HCO_3^-$) and natural organic matter (NOM). Treatability of commercial NZVI particles (NANOFER 25, Nanoiron, Czech) was tested by using a synthetic groundwater and the field groundwater samples. More than 95% of 1.8 mM TCE was removed within 20 hours with a NZVI dosage of 25 g/L ($k=0.15hr^{-1}$). Repetitive degradation experiments revealed that the removal capacity of NANOFER 25 was 0.19 mmole TCE/g NZVI. TCE degradation reactions were not substantially affected by the presence of each anion with concentrations as high as 100 times the average field concentrations. However, when the four anions ($NO_3^-$, $Cl^-$, $SO_4^{2-}$, $HCO_3^-$) were present simultaneously. the degradation reactivity and removal capacity were decreased by 60% ($k=0.069hr^{-1}$) and 10%, respectively. The k value of TCE degradation in the presence of NZVI (25 g/L) with dissovled organic carbon of 2.5 mg/L was also decreased by 84% ($k=0.025hr^{-1}$). In the experiments with the field groundwater, more than 90% of $1.8{\mu}M$ TCE, which is the concentration of TCE at the source zone, was removed within 10 hours with a NANOFER 25 dosage of 25 g/L. The results imply that the contaminated groundwater can effectively be treated by NANOFER 25 with more information on the hydrogeology of the site.

Responses of Artificial Flow-Sensitive Hair for Raider Detection via Bio-Inspiration (침입자 탐지용 인공 유동감지모의 응답 모델링)

  • Park, Byung-Kyu;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.355-364
    • /
    • 2010
  • Filiform hairs that respond to movements of the surrounding medium are the mechanoreceptors commonly found in arthropods and vertebrates. In these creatures, the filiform hairs function as a sensory system for raider detection. Parametric analyses of the motion response of filiform hairs are conducted by using a mathematical model of an artificial flow sensor to understand the possible operating ranges of a microfabricated device. It is found that the length and diameter of the sensory hair are the major parameters that determine the mechanical sensitivities and responses in a mean flow with an oscillating component. By changing the hair length, the angular displacement, velocity, and acceleration could be detected in a wide range of frequencies. Although the torques due to drag and virtual mass are very small, they are also very influential factors on the hair motion. The resonance frequency of the hair decreases as the length and diameter of the hair increase.

표면효과에 의한 Si 나노와이어의 전류 전압 특성

  • Park, Seong-Ju;Go, Jae-U;Lee, Seon-Hong;Baek, In-Bok;Lee, Seong-Jae;Jang, Mun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.409-409
    • /
    • 2012
  • 최근 나노크기의 미세구조 가공기술이 발달함에 따라 다양한 응용을 위한 나노소재/구조가 활발히 연구 되고 있다[1]. 그 중에서 실리콘 나노선은 태양전지, 메모리, 트랜지스터 그리고 광 공진기에 쓰일 수 있는 소재로서 기존의 실리콘 가공기술을 바로 사용할 수 있을 뿐 아니라[2], 비용 면에서 탁월한 잇점이 있기 때문에 주목 받고 있는 소재이다. 실리콘 나노선의 물리적 특성을 연구하기 위한 많은 연구가 진행되었지만, 매우 작은 크기와 높은 표면적-부피비율로 인해 생긴 독특한 특징을 완전히 이해하기에는 아직 부족한 점이 많다. 실리콘 나노선의 전류-전압특성에 영향을 미치는 요소는 도핑농도, 표면상태, 채널의 크기 등으로 다양한데, 이번 연구에서는 실리콘 나노선의 표면환경이 공기와 물 두 종류로 매질에 접하고 있을 경우에 대하여 각각 전류-전압을 측정하였다. 물이 공기와 다른 점은 크게 두 가지로 볼 수 있다. 첫째로 물의 경우에는 물에 용해된 수소이온과의 화학반응을 통하여 실리콘 표면전하가 유도되며 pH 값에 민감하게 변화한다. 둘째로 물의 유전율은 공기의 80배로서 표면부근에서의 전기장분포가 많이 왜곡된다. 이를 위하여 SOI를 기반으로 채널길이 $5{\mu}s$, 두께 40 nm, 너비 100 nm인 실리콘 나노선을 일반적인 반도체공정을 사용하여 제작하였다. 나노선의 전기적 특성 실험은 Semiconductor Parameter Analyzer (Agilent, 4155C)를 사용하여 전류-전압특성을 표면 상태를 변화시키면서 측정하였다. 실험을 통해 실리콘 나노선은 물과 공기 두 가지 표면환경에 따라 전류-전압특성이 확연히 변화하는 것을 볼 수 있었다. 동일한 전압 바이어스에서 표면에 물이 있을 때가 공기 있을 때 보다 훨씬 증가한 전류를 얻을 수 있었고(3V에서 약 2배), 비선형적인 전류-전압특성이 나타남을 관찰하였다. 본 발표에서는 이러한 실험결과를 표면에서의 전하와 정전기적인 효과로서 정성적으로 설명하고, 전산모사결과와 비교분석 하고자 한다.

  • PDF

다채널 표면 플라즈몬 공명 영상장치를 이용한 자기조립 단분자막의 표면 분석

  • Pyo, Hyeon-Bong;Sin, Yong-Beom;Yun, Hyeon-Cheol
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.74-78
    • /
    • 2003
  • Multi-channel images of 11-MUA and 11-MUOH self-assembled monolayers were obtained by using two-dimensional surface plasmon resonance (SPR) absorption. Patterning process was simplified by exploiting direct photo-oxidation of thiol bonding (photolysis) instead of conventional photolithography. Sharper images were resolved by using a white light source in combination with a narrow bandpass filter in the visible region, minimizing the diffraction patterns on the images. The line profile calibration of the image contrast caused by different resonance conditions at each points on the sensor surface (at a fixed incident angle) enables us to discriminate the monolayer thickness in sub-nanometer scale. Furthermore, there is no signal degradation such as photo bleaching or quenching which are common in the detection methods based on the fluorescence.

  • PDF

A Study on the U(VI), Ca(II) and Lu(III) Metal Ions Utilizing Nitrogen-Donator Synthetic Resin (질소-주게 합성수지를 이용한 U(VI), Ca(II) 및 Lu(III) 금속 이온들에 관한 연구)

  • 정만태
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 2000
  • The new ion exchange resin was synthesized from chloromethylated styrene-1,4-divinylbenzene(DVB) with 1-aza-15-crown-5 macrocyclic ligand by substitution reaction. The effect of pH, time, dielectric constant of solvent and cross-linked of the matrix on the adsorption for $UO_2^{2+}$, $Ca^{2}$ and $Lu^{3+}$ was investigated. The metal ion was not adsorbed on the resins below pH 3 but above pH 4 fast adsorption behavior was showed. The optimum equilibrium time for adsorption of metallic ions was two hours. The adsorption selectivity determined in ethanol matrix was in increasing order $UO_2^{2+}>Ca^{2}>Lu^{3+}$. The adsorption power was in the order of 1%, 2%, 10% and 20% -crosslinked resin, but adsorption properties of resins decreased in proportion to the order of dielectric constant of solvents used. In addition, these metal ions could be separated in the column packed with 1% crosslinked resin by pH2.5 $HNO_3$ as an eluent.

  • PDF

LiCl 감압 증류를 위한 폐쇄형 및 개방형 장치 기초 실험

  • Park, Byeong-Heung;Lee, Sang-Hun;Jeong, Myeong-Su;Jo, Su-Haeng;Heo, Jin-Mok
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.11a
    • /
    • pp.345-345
    • /
    • 2009
  • 전기화학적 환원 기술을 이용한 고온 용융염 전해환원의 결과 생산되는 금속전환체는 다공성 특성에 의해 전해환원의 매질인 용융염을 함유하게 된다. 전해환원과 후속 전기화학 공정인 전해정련의 전해질은 각각 LiCl과 LiCl-KCl 공융염으로 상이하기 때문에 이렇게 금속전환체에 포함된 LiCl 염이 동반되어 전해정련 공정에 도입될 경우 전해정련 공정의 공융염 조성을 어긋나게 한다. 이에 따라 금속전환체의 잔류염은 효과적으로 제거되어야 하며 공정으로 감압 증류에 의한 잔류염 제거 공정이 고려되고 있다. LiCl은 증기압이 비교적 낮기 때문에 감압의 고온 조건이 공정에 필요하다. 그러나 상평형도 분석 결과 전해환원 공정에서 산화물을 담아 음극으로 사용되어 환원된 금속전환체와 함께 도입되는 SUS 재질의 바스켓과 사용후핵연료 금속전환체의 주된 원소인 우라늄과는 공융할 수 있기 때문에 LiCl 증발 온도는 $720^{\circ}C$ 이하로 유지되어야 한다. 이와 같은 조건에서 LiCl 증발 속도를 높이기 위해서는 감압 조건이 필수적이다. 본 연구에서는 감압조건에서 LiCl 휘발 실험을 위해 폐쇄형 및 개방형 반응기를 제작하여 압력 조건 및 Ar 유량 등에 따른 LiCl 휘발율을 측정하였다. 증발된 LiCl은 일정 감압 조건에서 분말형으로 냉각부위에 회수 될 수 있었으나 완전 진공 조건에서는 결정형으로 냉각 부위에 응축되는 것으로 확인 되었으며 일정 진공 조건에서는 Ar 유량에 따라 증발량이 의존하지 않는 것으로 나타났다. 연구 결과 증발염의 취급 빛 이송을 위해 분말형 회수를 목표로 설정할 수 있었으며 공정조건으로 일정 수준의 감압 조건을 제시하였다. 이 후 후속 연구로 장치의 대형화 및 증발 속도 향상을 위한 추가적인 연구가 계획되어 있으며 연구 결과에 기초하여 공학규모 파이로 공정 시설인 PRIDE에 도입될 장치의 기초 설계 자료를 생산할 예정이다.

  • PDF

Strain-Softening Behavior of Circular Tunnel Excavated in Mohr-Coulomb Rock Mass (Mohr-Coulomb 암반에 굴착된 원형 터널의 변형률연화 거동해석)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.495-505
    • /
    • 2006
  • Calculating the distribution of stresses and displacements around a circular tunnel excavated in infinite isotropic rock mass subjected to hydrostatic stress condition is one of the basic problems in rock engineering. While closed-form solutions for the distribution are known if rock masses are considered as elastic, perfectly plastic, or brittle-plastic media, a few numerically approximated solutions based on various simplifying assumptions have been reported for strain-softening rock mass. In this study, a simple numerical method is introduced for the analysis of strain-softening behavior of the circular tunnel in Mohr-Coulomb rock mass. The method can also applied to the analysis of the tunnel in brittle-plastic or perfectly plastic media. For the brittle-plastic case where closed-formsolution exists, the performance of the present method is verified by showing an excellent agreement between two solutions. In order to demonstrate the strain-softening behaviors predicted by the proposed method. a parameter study for a softening index is given and the construction of ground reaction curves is carried out. The importance of defining the characteristics of dilation in plastic analysis is discussed through analyzing the displacements near the surface of tunnel.

Analysis of Combustion Characteristics of Bituminous and Anthracite Coal in a Fluidized Bed Combustor (유동층연소로에서 유연탄과 무연탄의 연소특성 해석)

  • Jang, Hyun Tae;Park, Tae Sung;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.586-591
    • /
    • 1999
  • Mixed-firing of a bituminous and an anthracite coal carried out in a batch fluidized bed combustor(0.109 m-I.D., 0.9 m-height). Effect of particle size an mixing fraction of anthracite and bituminous coal combustion characteristics were studied. The temperature profiles and pressure fluctuation properties were measured to interpret the combustion characteristics in a batch fluidized bed combustor. The used domestic anthracite coal has heating value of 2010 kcal/kg and the imported high-calorific bituminous coal has heating value of 6520 kcal/kg. The combustion characteristics in a batch fluidized bed combustor could be interpreted by using pressure fluctuation properties and temperature increasing rates. It was found that the optimum anthracite mixing percentage could be predicted analyzing the combustion rate and fluidization characteristics, The optimum mixing fraction was about 30 %. The different burning region of fluidized bed combustor was measured by temperature increasing rates.

  • PDF

Analysis of Higher Temporal Moments for Breakthrough Curves of Volatile Organic Compounds in Unsaturated Soil (불포화 토양에서 유동하는 가스상 Volatile Organic Compounds의 출현곡선에 대한 고차 Temporal Moment의 분석)

  • Kim, Heon-Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.60-69
    • /
    • 2007
  • Understanding the behavior of gas phase VOCs (volatile organic compounds) in unsaturated soils is of a great environmental importance for public health concerns. Moment analysis for the breakthrough curves (BTCs) during transport of chemicals in porous media was known to be a useful tool to evaluate the velocity, spreadness, and the skewness of the plume of the chemicals. In this study, the temporal moments of the BTCs of a group of VOCs were analyzed for the gaseous transport in an unsaturated soil. BTCs were measured using lab-scale column experiments for four different VOCs at the water saturation range of 0.04-0.46, and for eleven VOCs at a water saturation of 0.21. The central second and third moments of the VOCs were compared with the water saturation and the first moment. It was found that both central second and third moments increased with the first moment. The central third moment was, however, found to be more sensitive to the first moment.