• Title/Summary/Keyword: 반사율 투과율

Search Result 249, Processing Time 0.03 seconds

Ring-type Heart Rate Sensor and Monitoring system for Sensor Network Application (센서 네트워크 응용을 위한 반지형 맥박센서와 모니터링 시스템)

  • Jang, In-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.5
    • /
    • pp.619-625
    • /
    • 2007
  • As low power, low cost wireless communication technology like Bluetooth, Zigbee, RFID has been put to practical use together with the wellbeing trend, the concern about ubiquitous health care has been greatly increased and u-Health is becoming one of the most important application in the sensor network field. Especially, development of the medical services to be able to cope with a state of emergency for solitary senior citizens and the aged in silver town is very meaningful itself and their needs are also expected to continuously increase with a rapid increase in an aging population. In this paper we demonstrate the feasibility of extracting accurate heart rate variability (HRV) measurements from photoelectric plethysmography(PPG) signals gathered by a ring type pulse oximeter sensor attached to the finger. For this, we made 2 types of ring sensor, that is reflective and pervious type, and developed the remote monitoring system which is able to collect HR data from ring sensor, analyze and cope with a state of emergency.

Solution of TE Scattering by a Resistive Strip Grating Between a Double Dielectric Layer Using FGMM (FGMM을 이용한 2중 유전체층 사이의 저항띠 격자구조에 의한 TE 산란 해)

  • Uei-Joong Yoon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.619-624
    • /
    • 2023
  • In this paper, TE(transverse electric) scattering problems by a resistive strip grating between a double dielectric layer are analyzed by using the FGMM(fourier galerkin moment method) known as a numerical method of electromagnetic fileld. The boundary conditions are applied to obtain the unknown field coefficients, the scattered electromagnetic fields are expanded in a series of Floquet mode functions, and the resistive boundary condition is applied to analysis of the resistive strip. In order to deal with the problem of the double dielectric layer, numerical calculation was performed only when the thickness and relative permittivity of the dielectric layers had the same value. Overall, as the resistivity of the uniform resistivity increased, the current density induced in the resistive strip decreased, the reflected power decreased, and the transmitted power relatively increased. The numerical results of the structure proposed in this paper are shown in good agreement compared to the results of PMM, a numerical analysis method of the existing paper.

Analysis of Hydraulic Characteristics According to Operation of Movable Weir (가동보 운영에 따른 수리학적 특성 분석)

  • Seo, Il Won;Park, Sung Won;Kim, Tae-Won
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.101-101
    • /
    • 2011
  • 현재 국내에서 시행되고 있는 '4대강 살리기 사업'은 하천에서 발생하는 홍수 및 가뭄재해방지를 위한 다양한 공학적 노력을 시도하고 있다. 특히 안정적인 수위 및 유량확보와 홍수방지를 위한 보(weir)가 4대강 유역에 16개 설치되고 있다. 이러한 보 구간에는 고정보와 가동보가 복합적으로 설치되고 있으며 가동보는 그 형상과 운영방식에 따라 다양한 설계방안이 적용되었다. '4대강 살리기 사업' 중 낙동강 23공구의 강정보 공사 구간에는 원호형태의 측면 형상을 갖는 라이징 섹터게이트(Rising sector gate)가 적용되었다. 라이징 섹터게이트는 구조물의 높이가 낮고 수문의 개폐장치가 수문피어 구조물 내에 설치되어 경관이 우수하며, 구조가 간단하여 비체와 수류의 안정성이 뛰어나기 때문에 4개의 공사구간에 적용되었다. 따라서 본 연구에서는 강정보의 가동보 구간 2문 중 1문을 1/100 축척으로 제작하여 가변경사 개수로에 설치하고, 홍수 빈도별 상류 유량 조건과 하류단 수위조건으로 케이스를 정하여 실험을 수행하였다. 본 실험에서 사용한 개수로 장치는 너비 0.6 m, 높이 0.8 m, 그리고 길이 15.0 m(측정가능 구간, 헤드탱크와 테일게이트 부제외)의 개수로 실험장치이다. 측부는 모두 강화유리로 되어 육안관찰 및 계측 시 용이하게 제작되었으며, 순환식 유량 공급장치를 구축하여 수로의 하부에 설치된 유량탱크로부터 계속적으로 순환하도록 설계되었다. 또한 수로 하단으로부터 상단방향으로 약 33 m 지점에 전동 유압식 Jack screw 2기가 설치되어 경사도를 조절할 수 있도록 제작되었다. 유량조절용 판넬의 제어기판에는 디지털 경사계가 설치되어 있기 때문에 보다 정확한 경사도의 조절이 가능하다. 보 모형의 총연장은 53 cm이며 폭은 45 cm이다. 섹터게이트의 게이트부분은 직경 15 cm로 설계하였다. 문주부분을 포함한 모든 모형은 아크릴로 제작하며 레이저의 주사를 방해하지 않으며 투과율을 최대로 할 수 있도록 고강도의 아크릴을 가장 얇게 하여 중공형태를 채택하였다. 실험조건은 우선 보의 운영방안에 따라 게이트의 4가지 개방도를 설정하였고, 특히 평수위조건에서는 보의 상류부에 퇴적된 퇴적물의 세척을 위한 flushing 운영개방도 포함되어 있다. 홍수시에 대한 유량조건은 2년 빈도에 해당하는 유량을 수문의 비율과 상사법칙에 따라 설정하였으며 하류단 수위조건도 동일한 조건에 대한 값을 채택하여 적용하였다. 유동장의 해석을 위해서는 비접촉식 계측방법인 PIV(Particle Image Velocimetry) 시스템을 채택하여 2차원(x-z 방향) laser sheet를 생성하고 주입된 particle에서 반사된 변위(displacement) 정보를 상호상관(cross-correlation)기법으로 유동장을 계산하였다. 또한 수리모형과 동일한 지형격자를 구축하여 3차원 CFD 프로그램인 FLOW-3D로 계산하여 결과를 비교하였다. 특히 flushing 운영방안에 대한 게이트부의 개방도를 세가지(30, 45, $60^{\circ}$)로 구분하여 모의하였고, 적절한 개방도를 제안하고자 하였다. 실험결과는 우선 4가지 운영방안에 대한 가동보 주변에서의 유속장을 파악하였고, 최대유속의 발생위치의 변화를 확인할 수 있었다. 그리고 이에 따른 보의 바닥에서 최대유속이 발생할 경우, 하상보호공 위치와 거리 등에 대해서 분석하였다. 이를 통해 가동보 운영에 따른 다양한 유속구조를 파악할 수 있게 되며 구조적 안정성 확보를 위한 검증자료로 활용될 수 있을 것으로 예상된다. 향후, 가동보 운영방안 중 수세효과(flushing effect)에 대한 효과분석을 위해 게이트부 상류구간에 적절한 입경과 비중의 퇴적물질을 설치하는 연구와 상류부에서의 유입유사농도 및 시간변화에 따른 퇴적에 관한 연구를 수행할 계획이다.

  • PDF

Polymer Eyeglass Lens with Ultraviolet & High-Energy Visible Light Blocking Function for Eye Health (자외선 및 고에너지 가시광 차단 기능을 갖는 눈 건강을 위한 폴리머 안경렌즈)

  • Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.10-15
    • /
    • 2020
  • Ultraviolet rays, which have wavelengths smaller than 400 nm, are very harmful to the eyes. Recently, high-energy visible light was also revealed to be harmful to retinal cells. Therefore, polymer eyeglass lenses that can block UV and high-energy visible light are needed for eye health. In this study, high-refractive-index polymer eyeglass lens, n=1.67, were manufactured using the injection-mold method with the m-xylene diisocyanate monomer, 2,3-bis((2-mercaptoethyl)thio)-1-propanethiol monomer, benzotriazole UV absorber, release of alkyl phosphoric ester, dye mixture of CI solvent violet 13, and catalyst of dibutyltin dichloride mixture. A multi-layer anti-reflection coating was applied to manufactured polymer eyeglass lenses for both sides using an E-beam evaporation system. The optical properties of the manufactured lenses with the UV and high-energy visible light-blocking function were analyzed by UV-visible spectrophotometry. As a result, the polymer eyeglass lens with a UV absorber of 0.5 wt. % blocked 99% of UV and high-energy visible light shorter than 411 nm. The average transmittance of the polymer eyeglass lens with a UV absorber of 0.5wt.% was 97.9% in the range of 460 ~ 660 nm for photopic eye sensitivity higher than 10%. Therefore, clear image acquisition in photopic vision is possible.

The Effect of Ground Heterogeneity on the GPR Signal: Numerical Analysis (지반의 불균질성이 GPR탐사 신호에 미치는 영향에 대한 수치해석적 분석)

  • Lee, Sangyun;Song, Ki-il;Ryu, Heehwan;Kang, Kyungnam
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.8
    • /
    • pp.29-36
    • /
    • 2022
  • The importance of subsurface information is becoming crucial in urban area due to increase of underground construction. The position of underground facilities should be identified precisely before excavation work. Geophyiscal exporation method such as ground penetration radar (GPR) can be useful to investigate the subsurface facilities. GPR transmits electromagnetic waves to the ground and analyzes the reflected signals to determine the location and depth of subsurface facilities. Unfortunately, the readability of GPR signal is not favorable. To overcome this deficiency and automate the GPR signal processing, deep learning technique has been introduced recently. The accuracy of deep learning model can be improved with abundant training data. The ground is inherently heteorogeneous and the spacially variable ground properties can affact on the GPR signal. However, the effect of ground heterogeneity on the GPR signal has yet to be fully investigated. In this study, ground heterogeneity is simulated based on the fractal theory and GPR simulation is carried out by using gprMax. It is found that as the fractal dimension increases exceed 2.0, the error of fitting parameter reduces significantly. And the range of water content should be less than 0.14 to secure the validity of analysis.

원자층 증착법을 이용한 고 단차 Co 박막 증착 및 실리사이드 공정 연구

  • Song, Jeong-Gyu;Park, Ju-Sang;Lee, Han-Bo-Ram;Yun, Jae-Hong;Kim, Hyeong-Jun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.83-83
    • /
    • 2012
  • 금속 실리사이드는 낮은 비저항, 실리콘과의 좋은 호환성 등으로 배선 contact 물질로 널리 연구되고 있다. 특히 $CoSi_2$는 선폭의 축소와 관계없이 일정하고 낮은 비저항과 열적 안정성이 우수한 특성 등으로 배선 contact 물질로 활발히 연구되고 있다. 금속 실리사이드를 실리콘 평면기판에 형성시키는 방법으로는 열처리를 통한 금속박막과 실리콘 기판 사이에 확산작용을 이용한 SALICIDE (self-algined silicide) 기술이 대표적이며 CoSi2도 이와 같은 방법으로 형성할 수 있다. Co 박막을 증착하는 방법에는 물리적 기상증착법 (PVD)과 유기금속 화학 증착법 등이 보고되어있지만 최근 급격하게 진행 중인 소자구조의 나노화 및 고 단차화에 따라 기존의 증착 기술은 낮은 단차 피복성으로 인하여 한계에 부딪힐 것으로 예상되고 있다. ALD(atomic layer deposition)는 뛰어난 단차 피복성을 가지고 원자단위 두께조절이 용이하여 나노 영역에서의 증착 방법으로 지대한 관심을 받고 있다. 앞선 연구에서 본 연구진은 CoCp2 전구체과 $NH_3$ plasma를 사용하여 Plasma enhanced ALD (PE-ALD)를 이용한 고 순도 저 저항 Co 박막 증착 공정을 개발 하고 이를 SALICIDE 공정에 적용하여 $CoSi_2$ 형성 연구를 보고한 바 있다. 하지만 이 연구에서 PE-ALD Co 박막은 플라즈마 고유의 성질로 인하여 단차 피복성의 한계를 보였다. 이번 연구에서 본 연구진은 Co(AMD)2 전구체와 $NH_3$, $H_2$, $NH_3$ plasma를 반응 기체로 사용하여 Thermal ALD(Th-ALD) Co 및 PE-ALD Co 박막을 증착 하였다. 고 단차 Co 박막의 증착을 위하여 Th-ALD 공정에 초점을 맞추어 Co 박막의 특성을 분석하였으며, Th-ALD 및 PE-ALD 공정으로 증착된 Co 박막의 단차를 비교하였다. 연구 결과 Th-ALD Co 박막은 95% 이상의 높은 단차 피복성을 가져 PE-ALD Co 박막의 단차 피복성에 비해 크게 향상되었음을 확인하였다. 추가적으로, Th-ALD Co 박막에 고 단차 박막의 증착이 가능한 Th-ALD Ru을 capping layer로 이용하여 CoSi2 형성을 확인하였고, 기존의 PVD Ti capping layer와 비교하였다. 이번 연구에서 Co 박막 및 $CoSi_2$ 의 특성 분석을 위하여 X선 반사율 분석법 (XRR), X선 광전자 분광법 (XPS), X선 회절 분석법 (XRD), 주사 전자 현미경 (SEM), 주사 투과 전자 현미경 (STEM) 등을 사용하였다.

  • PDF

An improved crystal rotation method for simultaneous measurement of pretilt angle and thickness of a liquid crystal layer (액정셀의 선경사각과 액정층의 두께를 함께 재는 개선된 결정회전법)

  • Son, Gong-Sook;Park, Chan;Park, Hee-Gap;Kim, Jin-Seung;Rho, Bong-Gyu;Lee, Hyong-Jong;Kim, Jae-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.213-218
    • /
    • 1996
  • An improved crystal rotation method with increased accuracy and range is proposed and experimentally verified for simultaneous measurement of molecular tilt angle and thickness of LC (liquid crystal) layer of an LC cell. The improvement is brought about by direct determination of difference between phases instead of intensities of two components of orthogonal linear polarization of the light passing through an LC cell filled with uniformly oriented molecules. By comparing the experimental data with theoretical result the thickness and pretilt angle are determined more precisely. Further improvement is brought about by use of a liquid gate filled with an index matching liquid in which the LC cell is immersed. Because of the index matching liquid reflection of light at the surfaces of an LC cell almost completely disappears and the range of angle of refraction in the LC layer increases significantly, which gives rise to increased signal to noise ration as well as decreased statistical error. With this improvement precise measurement for either very thin (<10 ${\mu}{\textrm}{m}$) and/or higher pretilt angle($\geq$10$^{\circ}$) LC cells become possible.

  • PDF

Investigation on the Heating Patterns Depending on the Packaging Materials During Microwave Cooking (포장 소재에 따른 전자레인지 가열 조리 패턴 조사)

  • Lee, Hwa Shin;Cho, Ah Reum;Moon, Sang Kwon;Yoon, Chan Suk;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.21 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • Heating patterns depending on the packaging materials were examined in order to investigate the causes of thermal deformation of packages used for ready-to-eat foods for microwave heating due to the non-uniformity of microwaves. Physical properties including tensile strength, heat-resistance and elongation of four different CPP grades were compared. High retortable CPP had higher sealing strength and heat resistance compared to the conventional CPPs. All CPP samples tested were proved to have melting temperatures around $160^{\circ}C$. However, they were all thermally deformed by microwave heating due to a limited penetration of microwave and non-uniform heating within the spicy sauce of high viscosity contained high salt, especially on the above the filling line and sealing edge of pouches. When the laminated stand-up pouches composed of G-PET/PET/PET/CPP and G-PET/PET/NY/CPP were retorted and microwaved, significant deformations were noticed in both samples after retorting. Besides, pouches contained titanium dioxide showed more intense thermal deformation than the control. When the $10{\mu}m$ aluminium foil was affixed on the pouch, small thermal deformation was observed only in the bottom layer. More studies are required to prevent the thermal deformation of packaging materials used for RTE foods during microwave heating by developing the technologies to increase the thermal stability of CPP layer and the modification of packaging design to modify the microwave access into the package.

  • PDF

Fabrication of an Oxide-based Optical Sensor on a Stretchable Substrate (스트레처블 기판상에 산화물 기반의 광센서 제작)

  • Moojin Kim
    • Journal of Industrial Convergence
    • /
    • v.20 no.12
    • /
    • pp.79-85
    • /
    • 2022
  • Recently, a smartphone manufactured on a flexible substrate has been released as an electronic device, and research on a stretchable electronic device is in progress. In this paper, a silicon-based stretchable material is made and used as a substrate to implement and evaluate an optical sensor device using oxide semiconductor. To this end, a substrate that stretches well at room temperature was made using a silicone-based solution rubber, and the elongation of 350% of the material was confirmed, and optical properties such as reflectivity, transmittance, and absorbance were measured. Next, since the surface of these materials is hydrophobic, oxygen-based plasma surface treatment was performed to clean the surface and change the surface to hydrophilicity. After depositing an AZO-based oxide film with vacuum equipment, an Ag electrode was formed using a cotton swab or a metal mast to complete the photosensor. The optoelectronic device analyzed the change in current according to the voltage when light was irradiated and when it was not, and the photocurrent caused by light was observed. In addition, the effect of the optical sensor according to the folding was additionally tested using a bending machine. In the future, we plan to intensively study folding (bending) and stretching optical devices by forming stretchable semiconductor materials and electrodes on stretchable substrates.