A Study on Static and Fatigue Behavior of Restrained Concrete Decks without Rebar by Steel Strap (Steel Strap으로 횡구속된 무철근 바닥판의 정적 및 피로거동 특성 연구)

  • Jo, Byung Wan;Kim, Cheol Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.137-147
    • /
    • 2012
  • In the steel-free bridge concrete deck, steel straps are generally used instead of conventional steel rebar while laterally restrained in the perpendicular direction to the traffic in order fir the arching effect of concrete deck. In this paper, the minimum amount of FRP bar is to be suggested based on the structural strength, crack propagation, stress level and others in order to control cracks. As a result of laboratory tests, the structural strength of deck with 0.15 percentage of steel strap showed improved structural strength including ductility. The long-term serviceability of steel strap deck with FRP bar proved to satisfy the requirements and to be structurally stable while showing the amount of crack and residual vertical displacement within the allowable limits after two million cyclic loadings. The structural failure of RC bridge deck is generally caused from the punching shear rather than moment. Therefore, the ultimate load at failure could be estimated using the shear strength formula in the two-way slab based on ACI and AASHTO criteria. However the design criteria tend to underestimate the shear strength since they don't consider the arching effects and nonlinear fracture in bridge deck with lateral confinement. In this paper, an equation to estimate the punching shear strength of steel strap deck is to be developed considering the actual failure geometries and effect of lateral confinement by strap while the results are verified in accordance with laboratory tests.

Evaluation on Structural Performance of Precast Bridge Deck Joint using HSFRC (고강도 강섬유보강콘크리트를 적용한 프리캐스트 바닥판 이음부의 구조성능 평가)

  • Lee, Han-Joo;Chung, Chul-Hun;Shin, Dong-Ho;Park, Se-Jin;Kim, In-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.196-205
    • /
    • 2017
  • In precast deck system, structural performance and serviceability are mostly determined by the connection methods between the precast decks. This study proposes precast deck system with asymmetric ribbed connection details using High Strength Fiber Reinforced Concrete(HSFRC) with filler. To verify the proposed method, the flexural performance experiment was carried out with variation of joint cross section type and splice rebar details. From the test results, regardless of joint details, spliced tensile rebars of specimens were deformed to yielding strain level. Also, all types of specimens resulted in sufficient flexural performance. These test results show that the minimum lap splice length specified in current Korea Highway Bridge Design Code is conservative for precast deck joint using HSFRC. Therefore, splice details can be simplified and joint width can be reduced by using HSFRC with filler between the precast decks, and the proposed precast deck systems can be applied to the connection part of precast decks effectively.

Engineering characteristics of the Fiber Reinforced Floor Finishing Concrete According to the changes of Nylon Fiber Length (나일론 섬유의 길이변화에 따른 섬유보강 바닥마감용 콘크리트의 공학적 특성)

  • Jeon, Kyu-Nam;Baek, Dae-Hyun;Jung, Woo-Tai;Park, Jong-Sup;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.153-156
    • /
    • 2009
  • This study investigated the fundamental properties corresponding to various length changes on NY fiber reinforced concrete. For results of fresh concrete, the slump and air content were declined, but the unit volume weight and vebe time were increased. For the hardened concrete properties, the compressive strength showed increasing tendency according to the NY fiber length. The dry and autogenous shrinkage also decreased compared with Plain. Generally, the caes that 19 mm NY fiber was used was better than any other cases.

  • PDF

Development of Bridge Expansion Joint for Fiber Reinforced Polymer Deck (FRP바닥판용 신축이음장치 개발)

  • Lee, Young-Ho;Park, Jong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.348-353
    • /
    • 2007
  • This paper presents design specifications and characteristics of bridge expansion joints to develop new type-joints in fiber reinforced polymer decks. Based on properties of the fiber reinforced polymer decks and fundamental process to calculate their expansion length, new expansion joints fur fiber reinforced polymer decks on typical steel or concrete girder are developed and proposed.

  • PDF

Design of Ground Floor Slab According to the Method for Evaluating the Tensile Performance of Steel Fiber Reinforced Concrete (강섬유 보강 콘크리트 인장성능 평가방법에 따른 지반 바닥슬래브의 설계)

  • Lee, Jong-Han;Cho, Baik-Soon;Cho, Chang-Oh
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.1
    • /
    • pp.95-104
    • /
    • 2016
  • Flexural strength of concrete ground slab reinforced with steel fiber is evaluated using the equivalent flexural strength ratio of steel fiber reinforced concrete based on the yield line theory. Recently, the European standard specifies that the tensile performance of the steel fiber reinforced concrete be evaluated directly from the residual flexural strength after the cracking of concrete. Thus, in the study, an experiment was carried out to evaluate the conventional equivalent flexural strength ratio and the residual flexural strength of the steel fiber reinforced concrete. Then the design flexural strength was investigated according to the location of a point load, based on the ratio of the radius of contact area of the load to the radius of relative stiffness. Design flexural capacity obtained from ACI 360R-10 was smaller than that from TR 34 (2003 & 2013). In addition, TR 34 (2013), which evaluates the design flexural capacity based on the residual flexural strength, showed slightly smaller value than TR 34 (2003).

Evaluation on Effect of Constitution of Timber Framed Floor on Insulation Performance Against Impact Sound by Field Measurements (현장실험을 통한 목조바닥의 구성요소가 충격음 차단성능에 미치는 영향 평가)

  • Park, Joo-Saeng;Lee, Sang-Joon;Kim, Se-Jong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.431-444
    • /
    • 2012
  • Constituents of timber framed floor affect the insulation performance against impact sound significantly. Among them, installation of massive sound absorbing layer and reinforcement of stiffness of timber floor have been considered as major factors that improve the insulation performance against impact sound. Researches on evaluating the effect of floor constitutions have been carried out through the field measurements for timber framed buildings in Korea. It is concluded that the impact sound pressure level at the relatively lower frequency governs the overall insulation performance, and can be improved by the installation of sound absorbing layer and reinforcement of floor stiffness. Especially, the insulation performance against heavy impact sound was improved significantly when the massive cement mortar layer for floor heating system was installed and the stiffness was reinforced by shortening the joist span using additional beam at the mid-position of original span.

Evaluation on Static Behavior of Long Span Prestressed Concrete Deck (장지간 프리스트레스트 콘크리트 바닥판의 정적 거동 평가)

  • Joo, Sanghoon;Chung, Chulhun;Lee, Hanjoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.969-977
    • /
    • 2016
  • In this paper, the static load test of long span PSC deck used in the twin steel plate girder bridge was conducted. To evaluate the structural behavior of long span deck, longitudinally sufficient length of deck is needed, but it is difficult to test the full-scale long span deck due to limit of transportation, setting and laboratory space. Therefore, this study proposed a method to apply longitudinal stiffness of the full-scale deck to the test specimen of longitudinally short length, and it was reinforced with the steel beam. The failure behavior and structural performance of the long span deck were evaluated by the proposed test specimen deck.

Design Equation Suggestion through Parametric Study of Laterally Restrained Concrete Decks with Steel Strap (Steel Strap으로 횡보강된 콘크리트 바닥판의 매개변수해석을 통한 설계식 제안)

  • Kim, Cheol-Hwan;Yi, Seong-Tae;Jo, Byung-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.49-57
    • /
    • 2014
  • A deterioration of typical reinforced concrete (RC) bridge deck is due to the use of calcium chloride, cracks and water penetration inside of the deck slab with steel reinforcement. In order to eliminate the defects of RC decks in terms of material, therefore, the steel-strapped deck system is studied and developed by maximizing the arching effect while the girders are restrained using straps in lateral direction to the bridge. This parametric study was performed to analyze the structural characteristics of steel-strapped deck, and to identify the factors of the thickness, span length and lateral restraint stiffness of deck slab considering the concrete non-linearity. Finally, a design equation, which is adequate to South Korea, is suggested.

Flexural Strength Capacity of RC Decks Strengthened with Carbon Fiber Reinforced Polymers (탄소섬유복합재로 보강된 철근콘크리트 바닥판의 휨보강 성능)

  • Park Jong Sup;Park Young Hwan;Jung Woo Tai;Kang Jae Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.165-168
    • /
    • 2005
  • Carbon Fiber Reinforced Polymer(CFRP) composites are widely applied to strengthen deteriorated concrete structures. This paper presents the experimental results of the performance of reinforced concrete(RC) decks strengthened with CFRP composites. Simple span decks with 2m span length were tested to investigate the effect of CFRP reinforcement types on the flexural behavior of strengthened RC beams. The test results were analyzed with the special emphasis on the failure mode and the maximum load.

  • PDF