• Title/Summary/Keyword: 바닥 난방식

Search Result 22, Processing Time 0.018 seconds

Effects of Phase Change Material Floor Heating Systems using Direct Solar Gain on Cooling Load (직달일사를 이용한 잠열축열식 바닥난방 시스템이 냉방부하에 미치는 영향에 대한 검토)

  • Kim, Soo-Kyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.9-16
    • /
    • 2013
  • In this research, the effect of a heating system, which is powered by direct solar energy accumulated in phase change material (PCM) as heat storage material installed on the floor surface, on the cooling load was studied. Cooling load of a test building designed for this research was measured with fan coil unit and factors affecting it were also estimated. Experiments were performed with and without PCM installed on the building floor to understand the effect of the PCM on the cooling load. Additionally, to confirm the experiments results, the prediction calculation formula by average outside temperature and integrated solar radiation was composed using multivariate regression model. The results suggested that the heating system with PCM on the floor surface has the potential to shift electric power peak by radiating heat, stored during the daytime in it, at night, not increasing the total cooling load much.

A Study on Solar Heating System Technology Combining Multiple Technology with Mutual-Complementary Method - Low-cost, high efficiency, large-scale use of solar heating system - (다원기술 상호보완식 태양열 난방기술 - 저원가 고효율 규모화 태양열 난방 방안 -)

  • Nan, Bao-Xuan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.15-23
    • /
    • 2008
  • The article deals with system technology of a new solar heating system which systematically combines exiting solar collector technology, auxiliary electrical water heating, floor heating system and well insulated construction method and its application of this system to apartment house heating system in the cold region, and also analyzed performance of the new system in terms of technical and economic feasibility. Results shows that energy efficiency approaches up to 50% of the energy consumption of local construction from 1980 to 1981. The implementation of "DQ technology" to floor heating system achieved from 79% to 85% of the energy-saving benefits comparing to other housing units which were supplied by the local district heating plant.

An Experimental Study on the Evaluation of Thermal Performance of Floor mortar with PCM (PCM을 혼입한 방통 모르타르의 열적 성능 평가에 관한 실험적 연구)

  • Kim, Bo-Hyun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.5-6
    • /
    • 2011
  • CO2 reduction is the most urgent issue the world is facing. So, there should be a measure to reduce the CO2 emission in construction industry which has more released CO2 gas than other industries. CO2 emission of building depend on using energy. Then efficient energy use process working efficiently at CO2 reduction. Therefore In this study, author find the technical possibility of saving the building energy using the PCM which is able to control heat, storage heat and potential heat. So, it considered that apply to floor heating type which is major heating system of living space in Korea. And evaluate the Using possibility.

  • PDF

A Study on Thermal Performance of Cement Mortar with PCM (PCM을 혼입한 시멘트 모르타르의 열적성능에 관한 연구)

  • Kim, Bo-Hyun;Lee, Han-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.521-528
    • /
    • 2011
  • Recently, environmental concerns and issues have become great concerns for the public. Therefore, this study is conducted with the objective of preventing energy depletion and $CO_2$ emission. PCM (Phase Change Materials) having latent heat characteristic is mixed in mortar to find a proper mix proportion. Also, the mortar properties and performances as well as a melting point of PCM when applied to air conditioning and heating conditions in at building environments were obtained by performing experiments. Also, latent heat and heat transfer characteristics were obtained from experiments by test of thermal performance to formulate temperature gradient about amount of heat transfer of PCM content using the Fourier's thermal equation. The study results can be used in the application of PCM in buildings and expected effect of air conditioning and heating energy.

Development of Automatic Control System for Midnight Electric Ondol (축열식 전기온돌 공급시간자동제어시스템)

  • Park, S.;Jung, B.;Yu, S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.369-371
    • /
    • 2002
  • 기저부하조성 및 부하율 망상을 위한 심야 전력요금제도의 정착으로 최근 심야전력축열기기의 보급이 활성화되고 있다. 그러나 모든 심야전력축열기기들이 심야요금개시시간대인 22:00경에 동시에 가동됨에 따라 23:00경에 심야전력 부하가 최대에 이르러 전력피크가 발생하여 한전의 수요관리에 어려움을 주고 있다. 따라서 이 피크 부하를 심야전력 공급시간대의 저부하 시간대로 분산시킬 수 있는 심야전력기기 공급시간제어장치가 필요하게 되었으며, 이미 축열식전기보일러와 축열식 전기온수기에는 개발 보급되고 있는 실정이다. 이 논문에서는 다른 심야전력축열기기와는 달리 자연방열의 바닥축열난방방식인 축열식전기온돌의 공급시간자동제어장치 알고리즘을 실증실험을 통해서 검증하였다.

  • PDF

A Study on the Influence Affect of Thermal Sensation in Korean and Japanes to Sit Directly on a Heated Floor (바닥난방시 바닥 접촉면에 의한 한국인과 일본인의 온열감 반응에 대한 비교 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.81-89
    • /
    • 2002
  • The objective of this paper is to clarify the combined effect of heat conduction, air temperature and thermal radiation on the person seated on the floor under operation of floor heating system. Experiments were conducted for summer seasons under 8 kinds of condition: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$ and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$ under still air. Japanese and Koreans were adopted as subjects. To evaluate the effect of conduction operative temperature modified by heat conduction was derived from the human heat balance equation. New weighting coefficients were estimated from the modified operative temperature and modified mean skin temperature. As for thermal sensation the modified operative temperature more significantly correlated to that sensation each heat transfer processes. As the floor temperature is higher, the human conduction heat gain from floor increase and the dry heat from the human body decrease.

  • PDF

Estimation of the thermal performance on the double slab floor with supplying air (급기가 되는 이중바닥 구조체의 열 성능 평가)

  • Cha, Kwang-Seok;Park, Myung-Sig;Lee, Dae-Woo;Nam, Woo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

Evaluation on Termite Damage of the Traditional Wooden Building by Non-destructive Methods (비파괴 검사에 의한 전통목조건축물의 흰개미 열화 특성 조사)

  • Son, Dong-Won;Lee, Dong-heub
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.21-29
    • /
    • 2008
  • The deterioration of Korean traditional wooden house located in seoul was estimated. This house was attacked by termite. To estimate damage status of buildings, non-destructive methods were applied. Some of the post needed to be replaced due to low strength, estimated by nondestructive methods. The house was installed with boiler heating facility, to use office and public education. This kind of heating system changed the environmental condition of the wooden house. The termite which attacked the house was classified as Reticulitermes speratus. Because of durability of wooden house effected by environment, control of the environmental condition is essential for maintaining the wooden house. The installation of modern facility to traditional wooden house should not change the traditional structure and do not effect to durability of wooden house.

An Estimation on Indoor Thermal Environment by Pressurized Plenum Under Floor Air Conditioning System in Heating (난방시 가압식 바닥취출 공조방식의 실내온열환경 평가)

  • Choi, Eun-Hun;Lee, Yong-Ho;Kwon, Young-Cheol;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.92-99
    • /
    • 2010
  • The purpose of this study is to apply pressurized plenum under floor air conditioning system to office areas to understand characteristics of indoor thermal environment based on forms of diffusers. For doing this, the author conducted experiment of module measurement, and based on the results, analyzed indoor temperature distribution and velocity distribution based on direction of diffusion by using Computational Fluid Dynamics(CFD), and estimated the Predicted Mean Vote(PMV) of residents based on forms of diffusers to present the optimal air conditioning of the pressurized plenum under floor air conditioning system in heating. The results of this study are as follows. First, as for forms of diffusers, distributed diffusers rather than conical and grill diffusers were favorable in maintaining $24^{\circ}C$, the established temperature in heating, were active in velocity flowing, and were wide in a radius of diffusion. Second, as for position of pressurizing, the difference between upper and lower temperature was wider in center, lateral, and dispersed pressurizing (in order). As for velocity distribution, the velocity was more increased in lateral, center, and dispersed pressurizing(in order), indicating that dispersed pressurizing maintained uniform thermal environment. Third, as for diffusion direction, mixed direction showed less difference between upper and lower temperature and the difference in velocity between center and lateral part was 0.01m/1, indicating that it maintained uniform thermal environment. Fourth, as for the PMV of residents based on the forms of diffusers, the dispersed type showed(+) values above (0) when applied variably based on the position of diffuser, presenting thermal feeling of "being comfortable" to residents.