공동주택 바닥난방 시스템의 현황과 개선방향

  • 조동우
    • 월간 기계설비
    • /
    • s.43
    • /
    • pp.94-100
    • /
    • 1994
  • 본고에서는 기존 공동주택에 적용되고 있는 습식 바닥난방방식의 현황과 조립식 난방판넬의 현황과 문제점을 살펴보고 앞으로 조립식 난방시스템의 적립식 난방시스템에 적용시 검토사항 및 개선방향에 대하여 기술하였다.

  • PDF

Effect of Various Forms of Floor System on Performance of Meat-type Duck and Environments of Duck House (오리사 바닥 형태가 육용오리의 생산성 및 사육환경에 미치는 영향)

  • Bang, Han-Tae;Kim, Dong-Woon;Hwangbo, Jong;Na, Jae-Cheon;Kang, Hwan-Ku;Kim, Min-Ji;Mushtaq, M.M.H.;Parvin, R.;Choi, Hee-Chul;Lee, Sang-Bae;Kang, Min;Kim, Ji-Hyuk
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.253-262
    • /
    • 2013
  • This experiment was conducted to investigate the effects of floor type and heating system on performance, housing environment and health status of ducks reared in three types of duck house (OD : Open floor house-Direct heating system, OF : Open floor house-Floor heating system and LD : Loft type house-Direct heating system). In OF treatment, PVC pipes were installed for heating under concrete floor and covered with litter. In LD treatment, plastic mesh was installed 50 cm above the floor so that duck's droppings can pass through it. Each treatment had four replicates of 25 birds (Cherry Valley duck breed) per pen. There were no significant differences in weight gain and feed intake of ducks for 6 weeks among all treatments. However, feed conversion ratio in LD was significantly higher (p<0.05) than that in OF. No differences were found in carcass charac- teristics, with the exception of abdominal fat weight where OF were higher than the others. Concentrations of $CO_2$ and $NH_3$ gas in OD were higher than those of OF and LD at 3, 4 and 5 weeks. Moisture content in litter of OF was lower than that of OD. In contrast, the amount of dust in the air was higher in OF than in OD. The amount of fuel used for 6 weeks in LD was lower about 21% than that in OD. Some of unusual symptoms were observed in open floor house and loft type house, such as lying, spraddle legged, twisted ankle and legs, wounded sole, or etc. No components of leukocyte and erythrocyte of blood were significantly different among all treatments. The results of this experiment showed that OF and LD systems had no positive effects on performance of meat type commercial duck. However, there were some positive effects of certain house type for the improvement of environmental condition in duck house for hygienic production. In the future, more research on the effect of various facilities and systems for duck house is needed.

Evaluation of Thermal Comfort in Ceiling Heating System (천장복사난방이 인체에 미치는 쾌적성 평가에 관한 연구)

  • 이주연;이소다노리오;조관식
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.104-108
    • /
    • 2001
  • 복사에 의한 냉난방은, 장시간 재실하는 방이나 소음, 기류에 민감한 장소에 적합하고 에너지 절약면에서도 유효한 냉난방 방식이라고 알려져 있다. 일반적으로 널리 알려져 있는 바닥난방은 실온의 수직분포가 균일함으로서 인체에 쾌적한 난방방식으로 알려져 있다. 이것에 비해, 바닥의외의 벽, 천장을 활용한 냉난방설비의 쾌적성에 대해서는 아직 충분히 검토되고 잇지 않다. 따라서 본 연구는 물순환식 복사 냉난방장치를 이용하여 겨울철의 천장복사난방이 인체에 미치는 생리적, 심리적영향을 밝히고 복사난방의 유용성에 대해서 검토하는 것을 목적으로 한다. 실험은 일본 나라여자대학 인공기후실을 이용하였고, 실험조건은 실온 18$^{\circ}C$, 21$^{\circ}C$, 24$^{\circ}C$ 천장온도 $25^{\circ}C$, 3$0^{\circ}C$, 35$^{\circ}C$의 조건을 조합하여 7조건으로 설정하였다. 또, 상대 습도 40%, 기류속도 0.1m/s 이하로 일정하게 유지시켰다. 생리적반응으로는 피부온14점과 직장온을 30초 간격으로 측정하였고, 혈압, 심박수, 체중, 체지방율을 측정하고 심리적반응으로는 온열감, 쾌적감등의 항목을 10분간격으로 측정하였다.

  • PDF

The Actual State of Heat Conservation, Heating and Cooling in Greenhouses (온실의 보온 및 냉난방실태 분석)

  • 김문기;이석건;서원명;남상운;김란숙
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.39-44
    • /
    • 1998
  • 현재 국내에 보급되어 있는 현대화 온실 203개를 대상으로 냉난방과 관련된 설비현황을 조사하여 분석한 결과를 요약하면 다음과 같다. \circled1 온실의 건설방위는 남북동(58.1%)과 동서동(26.8%)이 대부분이었고, 철골온실은 Wide-span형이 81.8%, 플라스틱온실은 1-2W형 온실이 97.5%였다. 휴작하는 온실은 약 41%정도였고, 재배작물은 채소류가 약 80%, 화훼류가 약 20%정도였으며, 재배방식은 철골온실의 경우 양액재배가 57.2%, 플라스틱온실에서는 토양재배가 88.5%였다. \circled2 온실의 외부 피복재는 철골온실은 유리가 92.2%, 플라스틱온실에서는 PE가 43.3%, EVA가 51.9%로 대부분이었다. 철골온실은 1중피복이 98.7%로 거의 전부이었고, 플라스틱온실에서는 2중피복이 78.7%로 나타나, 철골온실에서 보온커튼을 통한 보온성 향상과 밀폐성이 더욱 중요함을 알 수 있다. \circled3 보온용 피복재는 부직포가 64.9%로 가장 많았고 대부분 2층커튼(85.9%)이었으며, 개폐방식은 대부분 예인식(92.7%)의 자동개폐방식(75.2%)이었다. 한편 바닥을 피복한 온실은 약 30% 정도로 나타나, 바닥피복으로 인한 축열이나 반사효과를 감안할 때 효율적인 바닥처리가 요망된다. \circled4 온실의 난방방식은 철골온실에서는 온수안방(47.3%)이 온풍난방(33.8%)보다 다소 많았으며, 플라스틱온실에서는 대부분 온풍난방(90.8%)이었다. 온실의 난방위치는 대부분 지상난방(89.8%)이었고 지중난방은 극소수로 나타나, 앞으로 지중난방을 통한 난방비 절감과 품질향상에 관한 실용화 연구가 요망된다. 난방용 연료는 대부분 경유(83.9%)로 나타나, 난방비를 절감할 수 있는 저가의 연료를 사용할 수 있는 난방시스템의 개발이 요청된다. \circled5 온실의 냉방방법은 차광(51.8%)과 지붕살수(33.9%)가 대부분이었으며 미스트와 포그시스템을 설치한 온실은 소수에 불과하였고, 극소수의 온실에서는 지붕위나 온실내에 지붕면과 평행하게 설치한 경우도 있었다.

  • PDF

Application Study of the Predictive Pulse Control for Floor Heating System (바닥난방을 위한 부하 예측식 펄스제어 방식의 적용성 연구)

  • Cho, Sung-Hwan;Kim, Seong-Su;Kim, Yong-Bong;Na, Hee-Hyeong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.167-175
    • /
    • 2007
  • A predictive pulse control strategy as a means of improving the energy efficiency of radiant floor heating systems is explored. Experiments at the apartment with floor heating system are conducted to assess and compare the energy performance of the predictive pulse control strategy with an existing conventional control strategy. The Results showed that new suggested PPCM( Predictive Pulse Control Method) was available to decrease the gap of $1{\sim}1.5^{\circ}C$ between maximum and minimum indoor temperature of each rooms. Therefore PPCM method was favor to radiant floor heating system which have a delay time of 10-20 minutes for heat transfer by floor layers.

  • PDF

A Experimental Study on the Application of GRNN for On-Off Control in Floor Radiant Heating System (바닥복사 난방시스템의 개폐식 제어에 대한 GRNN 적용에 관한 실험적 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.16-23
    • /
    • 2020
  • In this study, the control characteristics and effects of control methods on heating performance and energy consumption for the hot water floor radiant heating control system of a residential apartment were research by experiment. As a control method, On-Off control and outdoor reset control methods with GRNN(General Regression Neural Network) and without GRNN are considered. Also, the control performances with regard to improvement of indoor thermal environment and reduction of energy consumption are compared, respectively. Experiment results show that the performance of the control method with GRNN is better than that of conventional on-off control method without GRNN in the responses of room set temperature and energy saving.

Subjective Thermal Comfortness Evaluation from Various Parts of Human Body in Floor-Heated Room (실내 온열환경에 대한 신체부위별 온냉감 평가)

  • 최호선;이구형;박종한;김동규;금종수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.102-106
    • /
    • 1997
  • 본 연구는 실내 온열환경에 대한 인간의 온냉감을 정밀하게 평가하기 위해 바닥난방이 실시되고 있는 겨울철 아파트의 거실에 대하여 공간내의 온도분포를 조사하는 동시에 신체부위별로 온냉감을 조사하였다. 실내의 온도분포 측정은 서울과 부산의 두 장소에서 실시하였으며, 온냉감에 대한 평가는 서울에서 남자 31명, 여자 71명, 부산에서 남자 11명, 여자 23명에 대하여 수행되었다. 결과는 중앙집중식 난방이 실시되고 있는 거실의 바닥으로부터 10cm높이와 170cm 높이에서의 온도차이는 서울의 아파트가 3.2 $^{\circ}C$, 부산의 아파트가 2.$0^{\circ}C$로 나타났다. 겨울철 실내의 온냉감 조사는 하루 3 회 실시되었으며, 신체의 3개부위에 대한 온냉감과 전체적인 온냉감이 7점 척도로 평가되었다. 결과는 발과 얼굴, 무릎과 얼굴, 발과 전신사이에 온냉감의 차이가 있는 것으로 나타났다. 발과 무릎 부위가 얼굴에 비하여 추운느낌을 강하게 가지며, 전체적인 온냉감은 얼굴부위에서의 평가와 유사한 수준을 나타냈다. 난방이 단순한 온도조절의 범위를 넘어 인체의 온열쾌적감을 만족시키기 위해서는 신체의 부위별로 느끼는 온냉감을 정밀하게 평가하여 난방의 방법을 조정하여야 하는데, 이 연구의 결과는 난방의 방법 결정에 기초자료로 활용될 수 있을 것이다.

  • PDF

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 -)

  • Sone, Hyun-Kap;Ryon, Young-Sun
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.13-28
    • /
    • 1995
  • In this study, the history of Korean traditional Ondol was investigated and the latent heat materials and bioceramics were selected to develop the latent heat storage-bioceramics Ondol system based on the Korean traditional Ondol(sensible heat storage type), and the thermal characteristics of Ondol were analyzed experimentally The results could be summarized as follows; 1. Korean traditional Ondol has been originated in "Whaduk" which had been utilized continuously for about $2{\times}10^6$ years from the Old Stone Age to the Bronze Age, and Korean traditional Ondol using in these days has been utilized for about 976 years from the Koryu Dynasty to the Modern Ages. 2. $Na_2SO_4{\cdot}10H_2O(SSD)$ was selected as latent heat material for the latent heat storage Ondol. 3. Ondol unit was filled with the latent heat material of 0.63 kg and the dimension of Ondol unit was $400mm{\times}400mm{\times}27mm(width{\t\imes}depth{\times}height)$. 4. The comfortable surface temperature($23{\sim}29^{\circ}C$) of the latent heat storage Ondol was lasted 5 hours at the room temperature of $16{\sim}18^{\circ}C$, whereas that of sensible heat storage Ondol was lasted only 1.0 hours in the same conditions. 5. For the thermal effect of bioceramics, the Ondol air temperature i.n case of bioceramics treatment on the pannel was higher than that of without bioceramics treatment.

  • PDF

A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템의 열환경 개선을 위한 제어방안 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Kyung-Chul;Jang, Sa-Yun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

A Study on the Performance Analysis of Proportional Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템용 비례식 자동온도조절밸브의 성능해석에 관한 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.52-57
    • /
    • 2007
  • The control characteristics for radiant panel heating system with automatic thermostatic valves were researched by computer simulation and experiment. The unsteady energy analysis using equivalent R-C circuit method and radiation heat transfer analysis of enclosure analysis method with simple structured rooms was performed. The results of flow rate changes of the simulation study are good fit with the ones of experimental one.

  • PDF