The Composite Effects of Composite Truss using T-Shaped Steels (T형강을 사용한 합성트러스의 합성효과)

  • Lee, Myung-Jae;Choi, Byong-Jeong;Kim, Hee-Dong;Kang, Duck-Kyung;Sim, Min-Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.599-608
    • /
    • 2010
  • Steel trusses that act compositely with concrete slabs have proven to be an economical system for long-span floors. The composite action is generally achieved by providing shear connections between the steel top chord and the concrete topping. The composite sections have greater stiffness than the sum of the individual stiffnesses of the slab and truss. Therefore, steel trusses that act compositely with concrete slabs can carry larger loads and are stifferand less prone to transient vibration. During the tests that were performed in this study, the crack pattern and deflection of the beam of the composte truss were investigated. The test results were compared with the results for the noncomposite trusses.

A Study on the Dynamic Analysis of One-way Hollow Slab Using Equivalent Plate Element (등가플레이트 요소를 이용한 일방향 중공슬래브의 동적해석에 관한 연구)

  • Kang, Joo-Won;Lim, Jun-Ho;Chae, Seoung-Hun;Kim, Gee-Cheol;Seok, Keun-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.447-454
    • /
    • 2012
  • Considering that the weight of a hollow slab system is not increased with an incremental increase in its thickness, and that the flexural stiffness of a hollow slab is not significantly lower than that of a general slab, there has been a growing need for hollow slab system, because long span structures are in great demand. In a long span structure, the problem of vibration of floor slabs frequently occurs, and the dynamic characteristics of a hollow slab system are quite different from the conventional floor system. It is required to investigate the safety and the serviceability of hollow slab. Therefore, there exists a necessity for accurate vibration analysis. Hollow slab should be modeled by refined mesh for accurate vibration analysis. For the efficiency of the Eigenvalue Analysis, an equivalent plate slab model when can relatively precisely represent the dynamic behavior of a one-way hollow slab system is used. In conclusion, equivalent plate models relatively precisely presented the dynamic characteristics of one-way hollows.

Floor Noise Isolation System of the Residential Buildings Using Waste Rubbers (폐고무를 이용한 공공주택 층간소음차단 시스템)

  • Oh, Jeong Seok;Suh, Jaechan;Kim, Jin Kuk
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.427-431
    • /
    • 2017
  • Recently, complaints of floor noise have been growing up with the rapid increase of the residential buildings. This demands the effective floor noise isolation system. Since the construction of high-rise the residential buildings will be increased even more in future, the noise isolation is a more important technology in the market. In this study, a new floor noise isolation panel (FNIP) was designed and manufactured using waste rubbers. The noise isolation was investigated at both laboratory and field conditions. Light and heavy weight shock wave showed 52 dB and 48 dB in the field test, respectively. The new system could reduce the total floor thickness by 22~42 mm.

Experimental Study on Consumption of Energy and Heating Efficiency in Floor Water Heating System on Using Ondol Panel of Double Metal Rendering (이중금속융출형 온돌판넬을 이용한 바닥온수난방시스템의 난방성능과 에너지소비량에 관한 실험적 연구)

  • Bai, Dai-Kwon;Kim, Jin-Bong;Kim, Hwan-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6167-6175
    • /
    • 2012
  • This study is experimental analysis to verify heating efficiency of Ondol in floor heating panel developed. For this one, an experiment tests producing an each test speciment and measuring heating efficiency. The result of an experiment, supplying hot water temperature is $45^{\circ}C$ and the result of measuring on parts temperature of test speciment on supplying for 8 hours, mortar surface that is superstructure plumbing of heating system developed is $49.4^{\circ}C$, the gap of piping on center of mortar surface is $44.1^{\circ}C$ and airspace is proved $25.3^{\circ}C$. In floor structure of standards, mortar surface is $46.2^{\circ}C$, the gap of piping on center of mortar surface $37.7^{\circ}C$ and airspace is $24.7^{\circ}C$. On the other hand, energy consumption accumulating of development technology is identified, in case of hot-water supply on $45^{\circ}C$ as 4,646 kcal and in existing technology, as 4,814 kcal. developing technology is verified and lower than existing technology.

Development of Magnet Position Device for Outdoor Magnet Guidance Vehicle (실외 자기유도 무인운반차를 위한 자기 위치측정 장치 개발)

  • Cho, Hyunhak;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.3
    • /
    • pp.259-264
    • /
    • 2014
  • This paper is research paper on the MPD(Magnet Position Device) for the outdoor MGV(Magnet /Magnet Gyro Guidance Vehicle). Usually, MGV is used in indoor environment because of a measurement height of the magnet position device. CMPD(Commercial magnet position device) has 30 mm measurement height, so this is suitable structure in indoor environment like to a flat surface. Outdoor environment is an uneven and irregular, So Outdoor MGV must has a suspension. But CMPD is unsuitable for outdoor environment because of a collision with a surface caused by suspension. Thus, measurement height of the outdoor MPD is positively necessary more than 100 mm. So, we suggest the outdoor MPD using analog magnet hall sensor, moving average filter and Characteristic(rate of the magnet hall sensor) function of the localization. Result of the experiments, the proposed Magnet Position Device for the outdoor MGV has localization accuracy 4.31 mm, measurement height 150 mm and width 150 mm and is efficient more than CMPD.

Dust collection system optimization with air blowing and dust suction module (에어 블로어와 흡입기능을 가진 미세먼지 흡입시스템의 최적화)

  • Jeong, Wootae;Kwon, Soon-Bark;Ko, Sangwon;Park, Duckshin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.290-297
    • /
    • 2016
  • The performance of track cleaning trains to remove accumulated fine particulate matter in subway tunnels depends on the design of the suction system equipped under the train. To increase the efficiency of the suction system under the cleaning vehicle, this paper proposes a novel dust suction module equipped with both air blowing nozzles and a dust suction structure. Computational Fluid Dynamics (CFD) analysis with turbulent flow was conducted to optimize the dust suction system with a particle intake and blowing function. The optimal angle of the air blowing nozzle to maximize the dust removal rate was found to be 6 degrees. The performance of the track cleaning vehicle can be increased by at least 10 percent under an operation speed of 5km/h.

A Comparative Study on the Floor Vibration Evaluation methods of Flat Plate Slab System (플랫슬래브 바닥구조시스템의 진동계산식의 비교)

  • Kang, Dae-Eon;Kim, Jong-Ho;Kim, Ji-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.153-156
    • /
    • 2008
  • The serviceability evaluation methods regarding floor vibration can be found in foreign building codes or design guides for vibration. AISC, AIJ, CEN, CSA and ISO are sucn examples. However, because the those guides are based on each country's experimental results, there will be different evaluation results for the same conditions. Meanwhile, in korea, we have little research results that suits for our condition, and we continue to use those foreing guides. In this paper, 20 flat plate slabs were carried out to investigate the accuracy of existing frequency formulas.

  • PDF

A Study on Experimental Analysis of Dynamic properites for Structure and its Application (구조물 동특성의 실험적 해석과 응용기술에 관한 연구 (기계식 주차설비 진동제어))

  • 이홍기;박상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.40-45
    • /
    • 1993
  • 일반적으로 건물 구조물에 전달되는 기계진동을 감소시키기 위해서 기계와 기초사이에 유연한 방진소자를 삽입하여 기계가진력(exciting force)의 전달 률을 줄인다. 또한 구조물의 고유진동수와 진동원의 가진주파수가 일치할 경 우, 가진주파수를 변화시키거나, 구조물의 동특성을 변화시키는 방법을 사용 한다. 어떠한 방안을 선택하든 효과적이고 정량적인 방진 시스템을 구성하고 구조물의 정확한 진동상태를 예측하기 위해서는 진동원의 가진특성과 구조 물의 동특성에 대한 정보가 요구된다. 일반적으로 방진설계를 위해 필요한 진동원의 가진특성은 제조회사의 사양이나 측정을 통하여 비교적 쉽게 얻을 수 있다. 복합재료, 다양한 경계조건, 복잡한 대형구조물등은 수치해석을 이 용하여 해석적인 방법으로 동특성을 구할 경우, 신뢰성 있는 정보를 얻기에 는 많은 노력이 요구된다. 더우기 현장에서 발생하는 진동문제는 대부분 복 잡하고 시간적으로 시급히 해결해야 하기 때문에 효율적인 절차를 구성하여 구조물의 동특성을 해석하는 방법을 사용할 필요가 있다. 구조물의 동특성은 실험적인 방법을 통하여 구하고 그 외의 필요한 계산들은 해석을 통하여 얻 는 것이 효율적일 수 있다. 실험적 동특성해석은 입력하중에 대한 응답의 크 기와 위상 비를 주파수별로 나타내는 전달함수를 측정하는 방법으로서 가진 장치 및 여러 측정/분석 장비가 필요하며, 철교, 교량, 건물의 철골 및 콘크 리트 슬라브등 다양한 중대형의 구조물을 Signal/Noise비가 좋도록 가진 시 켜야 할 필요성이 있다. 본 연구에서는 이러한 실험적 방법의 현장 적응성과 신뢰성을 확보하기 위해 대형충격기(large impact hammer, max, peak force 약 10000N, time duration 약 20ms)를 제작하고 실험/분석 시스템 및 구조물 의 진동제어를 위한 절차를 Fig.1과 같이 구성하고 이를 철근콘크리트 건물 에 설치한 기계식 주차설비의 진동제어에 적용하였다.force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity value. The results shows

  • PDF

Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings (초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.19-33
    • /
    • 2008
  • Dynamic response measurements from natural excitation were carried out for 25- and 42-story buildings to evaluate their inherent properties, such as natural frequencies, mode shapes and damping ratios. Both are reinforced concrete buildings adopting a core wall, or with shear walls as the major lateral force resisting system, but frames are added in the plan or elevation. In particular, shear walls in a 25-story building are converted to frames from the 4th floor level downwards while maintaining a core wall throughout, resulting in a fairly complex structure. Due to this, along with similar stiffness characteristics in the principal directions, significantly coupled and closely spaced modes of motion are expected in this building, making identification rather difficult. By using various state-of-the-art system identification methods, the modal parameters are extracted, and the results are then compared. Three frequency-domain and four time-domain based operational modal identification methods are considered. Overall, all natural frequencies and damping ratios estimated from the different identification methods showed a greater consistency for both buildings, while mode shapes exhibited some degree of discrepancy, varying from method to method. On the other hand, in comparison with analysis results obtained using the initial finite element(FE) models, test results exhibited a significant difference of about doubled frequencies, at least for the three lower modes in both buildings. To improve the correlation between test and analysis, a few manual schemes of FE model updating based on plausible reasons have been applied, and acceptable results are obtained. The advantages and disadvantages of each identification method used are addressed, and some difficulties that might arise from the updating of FE models, including automatic procedures, for such large structures are carefully discussed.

Development of Macro-Element for the Analysis of Elastically Supported Plates (탄성 지지된 판구조 해석을 위한 매크로 요소의 개발)

  • 강영종;박남회;앙기재;최진유
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.1
    • /
    • pp.25-35
    • /
    • 2000
  • The superstructure of general bridge like slab bridge and slab on girder bridge is composed of elastically supported isotropic plate. The objective of this study is to develop the new analysis method for elastically supported plate with general edge beam or girder(boundaries) under arbitrary out of plane loading. The displacement solutions for the macro-element of plate and beam are obtained by solving for the unknown interactive forces and moments at the beam or nodal line locations after satisfying equilibrium equation along the nodal line. The displacement functions for macro-elements ate proposed in single Fourier series using harmonic analysis, and the equilibrium equations of nodal line are composed by using slope-deflection method. The proposed analysis method is programmed by MS-Fortran and can be applied to all types of isotropic decks with bridge-type boundaries. Numerical examples involving elastically supported plates with various aspect ratio, loading cases, and bridge-type boundary conditions are presented to demonstrate the accuracy of this program. The major advantage of this new analysis method is the development of a simple solution algorithm, leads to obtain rapidly responses of bridge deck system. This proposed method can be used in parametric study of behavior of bridge decks.

  • PDF