When floor vibration problems occur in existing buildings, TMD (tuned mass damper) can be a viable alternative to resolving the problem. Only when TMD has been exactly tuned to the natural frequency of the floor, it can control the vibration as intended in design. However, TMD gets inefficient in the situation where the natural frequency changes as a result of the uncontrollable variation of the floor mass weight. This physical phenomenon is often called as TMD-off-tuning. This study proposes asymmetric TMD for enhancing the robustness of floor vibration control against uncertain natural frequencies. The proposed TMD features two asymmetric linear springs such that the floor vibrational energy can be dissipated through both the translational and rotational motion. An easy-to-use graphical optimization method was developed in this study. The asymmetric TMD proposed outperformed in vibration control by 28% compared to that of conventional TMD. The robustness of asymmetric TMD of this study was two times higher than that of conventional TMD.
최근 고층형 주거 시설이 많이 보편화됨에 따라 층고절감과 시공의 효율성 제고 등에 대한 요구가 크게 증가하고 있다. 이에 층고를 절감하면서 동시에 장스팬을 구현할 수 있는 GFRP를 이용한 경량 중공 합성 바닥을 개발하였다. 이 바닥 시스템은 웨브에 개구부를 가지는 비대칭 철골보와 중공 경량체, 콘크리트 그리고 내력 보강 및 내화 성능 증진을 위해 비대칭 철골보 하부에 부착한 GFRP(Glass Fiber Reinforced Plastics)로 구성된다. 본 연구에서는 이 GFRP를 이용한 경량중공 합성 바닥의 진동 특성을 부재 단위 실험체를 제작하여 실험적으로 검토하였으며, 이를 통해 본 개발 합성 바닥의 고유 진동수 및 감쇠율을 측정하였다, 그 결과 기존의 이론에 근접한 진동 특성을 나타내었다.
Proceedings of the Korean Society for Noise and Vibration Engineering Conference
/
2014.10a
/
pp.208-213
/
2014
공동주택의 천장구조는 바닥충격음을 변화시키는 영향요소중의 하나이다. 천장구조의 진동응답 특성이 바닥충격음에 영향을 주는 요소를 확인하기 위해 천장구조의 달대를 제거하여 콘크리트 슬래브의 진동이 천장구조에 전달되지 않는 무달대 천장구조를 개발하였다. 달대가 시공된 일반 천장구조와 대비하여 무달대 천장구조의 천장판 가속도와 바닥충격음 레벨을 비교하였다. 무달대 천장구조를 사용함으로서 콘크리트 슬래브의 진동이 천장구조에 전달되는 것을 절연되어 천장구조의 진동응답 증폭을 저감시킬 수 있었으며, 저주파 대역의 바닥 충격음 증폭 또한 저감시킬 수 있었다. 일반 천장구조는 100 Hz 이하에서 천장구조의 진동응답이 증폭되어 저주파 대역 바닥충격음이 증폭되었다.
Journal of the Computational Structural Engineering Institute of Korea
/
v.18
no.1
/
pp.61-69
/
2005
As long-span and light-weight deck floor slab are flexible and have low inherent damping, the significant floor vibration could be induced by residents' activities. These floor vibrations affect to safety and serviceability of building structures. So the vibration criteria are applied to the quality assessment of building structure. Therefore, the accurate vibration analysis should be performed for the correct assessment of deck floor slab. In this paper, practical analysis method with considering orthotropic rigidity of deck floor is proposed tot the accurate vibration analysis of dock floor slabs with form deck plates.
Journal of the Earthquake Engineering Society of Korea
/
v.10
no.5
s.51
/
pp.35-48
/
2006
The object of this study is to propose the efficient method for analyzing the building floors subjected to the loading with high frequency contents. For this purpose, the method for mesh division and the selection of master DOF for FE model of building floors with these loadings are studied. Also, it is verified that the availability of thin plate element that is used by structural engineers for the modelling of the building floor of which the span-thickness ratio is usually ten times and over. And the possibility and limit of the equivalent plate which is already studied by other researcher for the multi-layer plate are investigated. At last, proposed modelling method is examined by the example structure.
Park, Hae-Dong;Kim, Kang-Boo;Lee, Hong-Ki;Chun, Chong-Keun
Proceedings of the Korean Society for Noise and Vibration Engineering Conference
/
2004.11a
/
pp.184-187
/
2004
TFT LCD 생산 공정에 사용되는 정밀측정/검사/생산장비가 위치하는 바닥의 진동문제는 크게 장비자체의 가동에 의한 것과 장비외부의 가진원에 의해서 정밀장비의 바닥에 진동이 발생하게 된다. 이러한 진동문제는 건물을 설계 시공하는 건축자의 입장에서는 장비 가동전 건물 인수시 진동문제에 관심이 있으나 장비를 운영하는 사용자의 입장에서는 장비 가동전의 진동문제와 더불어 장비 가동시 장비내부의 진동원에 대해서도 진동대책을 요구하게 된다. 따라서 양자의 진동문제 해결을 위해서는 정밀장비 주변의 진동원에 대한 동하중 설계자료와 함께 장비 가동시 바닥에 진동을 발생시키는 진동원인 장비에 대해서 동하중을 파악하여야 한다. 장비기초의 단위하중에 대한 진동응답을 표현하는 주파수 전달함수는 이러한 동하중과 바닥의 진동허용규제치를 동시에 표현하는 요소로 기존의 정밀장비가 요구하는 장비바닥의 진동허용규제치와 함께 동하중을 유발하는 장비기초에서는 반드시 구조물의 동강성 허용규제치를 이용한 구조물의 동적설계가 요구된다.
Proceedings of the Korean Society for Noise and Vibration Engineering Conference
/
1993.10a
/
pp.151-156
/
1993
본 논문에서는 탄성바닥 위에서의 세개의 질량과 두개의 방지재로 구성된 지지계에 의한 진동절연의 이론적 고찰과 실험에 의한 검증을 하였다. 효과 적인 진동절연은 본 논문에서 기본적으로 관심을 가지는 탄성바닥에서의 진 동전달률을 감소시키는 것이며, 단순한 수학적 형태로 표현되는 진동전달률 공식은 영향계수법(Receptance Method)을 이용하여 유도된다.
Proceedings of the Acoustical Society of Korea Conference
/
1992.06a
/
pp.137-140
/
1992
실내 바닥슬래브의 휨진동에 의한 음향방사문제에 대하여 유한요소법을 적용하여 검토하였다. 단순한 형상의 판이 휨진동하여 자유공간에 음을 방사하는 문제에 대해서는 이론적인 해를 구할 수 있으나, 임의형상의 판이 휨진동하여 실내에 음을 방사하는 문제에 대해서는 검토되지 않았다. 따라서 본 연구에서는 이와같은 문제를 단순화한 해석법으로서 먼저 유한요소법을 이용하여 판의 휨진동에 대한 고유모드의 상대변위를 구하고, 다음 상대변위를 진동속도로 변환한 결과를 입력조건으로 하여 유한요소법에 의한 3차원 음장해석을 하였다. 그 결과 실내 바닥슬래브의 휨진동에 의한 음향방사파워는 슬래브의 진동모드, 실내음향모드 및 벽흡음율 등의 조건에 따라 크게 변화된다는 것을 확인하였다.
Park, Kang-Geun;Kim, Yong-Tae;Choi, Young-Wha;Kim, Han-Choul
Proceeding of KASS Symposium
/
2006.05a
/
pp.246-255
/
2006
In these days the floor vibration is beginning to make its appearance of the environmental dispute in apartment building. Standard floor system are suggested for the settlement of this issue by government. The sound of floor impact sound is needed to secure comfortable quality in housing. Also, it is required an accurate analysis and a proper evaluation for floor vibration. Refine model is necessary for the floor system of housing to analyze accurately the floor vibration. But this refine model is not efficient because it is required so much running time for vibration analysis and it is difficult of modeling of standard floor slab. In this paper, new modeling methods of standard floor slab are proposed for the accurate rigidity evaluation. By using the new modeling method, the accurate vibration response can be obtained and can accurately evaluate the rigidity of standard floor system with resilient materials. Therefore the proposed modeling method is of practical use for vibration analysis of floor system of apartment building.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.