• Title/Summary/Keyword: 바닥조도

Search Result 208, Processing Time 0.029 seconds

A Study on the Chemical Powdering Process of Polypropylene Resin for Anti-slip Floor Paint (미끄럼 방지 바닥 도료용 폴리프로필렌 수지의 화학적 분쇄에 관한 연구)

  • Kim, D.I.;Chung, H.Y.;Hwang, S.H.;Cho, I.S.;Youn, K.J.;Cho, B.S.;Kim, K.K.;Yun, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.78-83
    • /
    • 2012
  • In this study, some experimental results of the peroxide-degradation process of polypropylene(PP) in a co-rotating twin-screw extruder to produce controlled rheology polypropylene(CRPP) are presented. The peroxide was dicumyl peroxide(DCP) and the concentration of DCP was in the range 0-0.3 wt%. It was found that the rheological properties of PP change significantly during reactive extrusion. Melt flow index(MFI) increased with DCP concentration. Intrinsic viscosity decreases with increasing DCP concentration. From dynamic rheological data, number average molecular weight(Mn), weight average molecular weight(Mn) and molecular weight distribution(MWD) were calculated. Results indicated that Mw decreases and MWD becomes narrower with increasing peroxide concentration. Especially, particle size distribution of CRPP decreases with increasing DCP concentration by chemical powdering process, and anti-slip floor paint, CRPP(DCP 0.2 wt%) powder by 10phr was friction coefficient 2.15 ${\mu}$, abrasion resistance 511.18%.

Numerical Analysis of Flow Characteristics of Secondary Currents in Curved Channels (사행수로에서 2차류 거동에 대한 수치해석)

  • Seo, Il-Won;Shin, Jae-Hyun;Kim, Tae-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.558-558
    • /
    • 2012
  • 다수의 자연 하천은 유사 이동과 하안의 침식으로 인하여 사행 하천이 발생한다. 사행 하천에서의 이차류는 원심력, 편수위로 발생하는 중력에 의한 압력차, 그리고 난류로 인하여 발생하는 응력으로 인하여 형성되며 나선형 구조 형태로 표면 유속은 외부로 향하고 하천 바닥의 유속은 안으로 향하게 된다. 이러한 2차류의 형성은 주 흐름의 특성을 변형시킨다. 자연하천에서 2차류는 주 흐름의 15-25%의 크기를 가지고 있으나, 하상의 변화, 유사의 이동 등과 연관되므로 2차류의 영향을 정확히 해석하는 것은 수리학적으로 매우 중요하다. 본 연구에서는 사행수로에서 발생하는 2차류 거동을 수치모의를 통하여 수행하였다. 우선 2차류의 분석을 위하여 실험을 통한 결과물을 비교하였다. 자연 하천의 특성을 반영할 수 있도록 서일원(2006)이 수행한 S-자 형태의 실험 수로의 실험 결과를 분석하였다. 수치 모의를 위하여 3차원 전산유체역학 프로그램을 사용하여 사행수로의 2차원 유속 구조를 모의할 수 있도록 하였다. FLOW-3D 프로그램을 이용하여 실험 결과와 모의 결과를 비교할 수 있도록 하였으며 비교 후 보정을 실시하였다. 모의는 주로 LES (Large Eddy Simulation) 모형을 통해 이루어졌으며, 이를 통하여 실험에서 획득한 결과와 비슷한 유속구조 분포를 확인할 수 있었다. 보정 및 검증 후 수치 모의를 통한 유속 데이터를 이용하여 민감도 분석을 실행하였다. 이후로는 수로의 만곡부, 조도, 수심 등 인공수로의 조건을 변경하여 수치 모의를 수행하였다. 보정된 결과를 이용하여 추가적인 모의를 통한 유속 분포 구조의 비교가 이루어졌다. 이를 통하여 각 조건이 이차류의 크기에 미치는 영향을 확인할 수 있었으며, 모의를 통한 유속분포 결과는 대체적으로 실험을 통한 이차류의 연직분포 구조와 일치하였다.

  • PDF

Effects of floor type and hanging type environmental enrichment on the behavior of growing pigs (바닥형과 현수형 환경 보조물이 육성돈의 행동에 미치는 영향)

  • Kim, Doo-Wan;Kim, Young-Hwa;Min, Ye-Jin;Yu, Dong-Jo;Jeong, Yong-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.282-289
    • /
    • 2017
  • Animal Welfare is spreading throughout the world, but remains weak in Korean swine farms. Therefore, the aim of this study was to identify the effect of floor type and hanging type environmental enrichment on the behavior of growing pigs under the traditional feeding environment. A total of 45 crossbred pigs (Yorkshire${\times}$Landrace${\times}$Duroc; average weight, $33.35{\pm}5.5kg$) were assigned into three treatments consisting of control, hanging type(T1) and floor type(T2) with three replicates in semi-slurry pen. The hanging enrichment was suspended at shoulder height of the pigs, and the floor enrichment was fixed in the center of the pens. Growth and cortisol were estimated at the end of the experimental period. Behaviour patterns were analyzed on the first and eighth days after starting the experiment. Growth was not differed among control and treatments. However, cortisol was decreased in T2 compared to control(25.28 vs. 46.75 ng/mL; p<0.05). On the first day, movement and aggression were lower in both treatments than in control(p<0.01). On the eighth day, time and frequency of playing action were increased in T2 compared to T1(p<0.01) and both treatment groups showed more active behaviour than control(p<0.01). These results suggested that the enrichment may meet the natural action requirement of pigs. Therefore, our data can be utilized as basic information for welfare with environmental enrichments in farm animals.

Heating and Cooling Energy Demand Evaluating of Standard Houses According to Layer Component of Masonry, Concrete and Wood Frame Using PHPP (PHPP를 활용한 조적, 콘크리트, 목조 레이어 구성별 표준주택 냉·난방 에너지 요구량 평가)

  • Kang, Yujin;Lee, Junhee;Lee, Hwayoung;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • A lot of the energy are consumed on heating and cooling in buildings. The buildings need to minimize the heating and cooling loads for $CO_2$ emissions and energy consumption reduction. In recently, also demand of detached houses were increase while the residential culture was changed. The structure of the domestic detached houses can be divided into masonry, concrete, wood frame houses. Therefore, in this study, the heating and cooling load and energy demand were analyzed on the equal area detached house consisting of three structural methods (Masonry, Concrete, Wood frame). Layer of wall, roof, and floor were composited by structure. Thermal transmittance (U-value) of each layer was using the PHPP calculation for considering stud, such as the wood frame wall. In addition, the case of without considering for studs in wood frame wall (Non-studs) was analyzed in order to compare the difference between studs or not. Analysis was performed using self-developed heating and cooling load calculation program (CHLC) based excel and ECO2. The results of cooling and heating load and energy demand showed the highest values in the wood frame structure, and the concrete structure were confirmed to maintain a high value secondly. Two structure were determined to be disadvantageous on the energy consumption. Consequently, the masonry structure have an advantage over the other structure under the identical conditions. It was determined that if the except for thermal bridges due to the studs in the wood frame structure, it can be reduced the energy consumption.

Local Buckling in Steel Box Girder Bridge with Lifting and Lowering Support Method (지점 상승 하강 공법에 의한 강상자형교의 국부좌굴)

  • Koo, Min Se;Jeong, Jae Woon;Na, Gwi Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.77-85
    • /
    • 2003
  • The lifting and lowering supports method makes up for the weak points in the classical method and provides makes construction economical effect to construction. The application of pre-compression to continuous steel box girder bridges makes it possible to reduce the amount of steel, the height of girders and consequently, the cost consequentlyof the bridges' construction by through the process of concrete filling- up and the lifting-lowering of the inner supports. The lifting and lowering supports method is apt to cause local buckling in the lower flange and web plates by due to the process of the lifting of the inner supports. Therefore iln this study, therefore, the possibility of local buckling could be decreased, in consideration of the lifting force and the buckling strength of stiffened plates, by increasing the number of longitudinal stiffeners and the installation of extended longitudinal stiffeners on the lower flange and the web plates in the range of positive moment.

Seismic Retrofit of Welded Steel Moment Connections Considering the Presence of Composite Floor Slabs (바닥슬래브를 고려한 용접철골모멘트접합부의 내진보강)

  • Lee, Cheol Ho;Kim, Sung Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.1
    • /
    • pp.25-36
    • /
    • 2017
  • In the 1994 Northridge earthquake, connection damage initiated from the beam bottom flange was prevalent. The presence of a concrete slab and resulting composite action was speculated as one of the critical causes of the prevalent bottom flange fracture. In this study, four seismic retrofit schemes are proposed in order to salvage welded steel moment connections with composite floor slabs in existing steel moment frames. Because top flange modification of existing beams is not feasible due to the presence of a concrete floor slab, three schemes of bottom flange modification by using welded triangular or straight haunches or RBS(reduced beam section), and beam web strengthening by attaching heavy shear tab were cyclically tested and analyzed. Test results of this study show that haunch and web-strengthened specimens can eliminate the detrimental effect caused by composite action and ensure excellent connection plastic rotation exceeding 5% rad. Design recommendations for each retrofit scheme together with supplemental numerical studies are also presented.

A Study on the Structural Behavior of the Composite Slab with New-Shaped Deckplate (신형상 데크플레이트를 이용한 합성슬라브의 구조적인 거동에 대한 연구)

  • Huh, Choong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.341-350
    • /
    • 1997
  • The objective of this study is to investigate the structural behavior of the composite slabs with the new metal deckplate. The new deckplate can be used as structural member with topping concrete. So several experiments of this structural test and the fire resistance test were done. From this experiments. slabs with new metal deckpklate were verified as composite slabs. In this paper, this verifications were compared with the international design methods. For experiment. 49 specimens were made. the main parameters are deckplate thickness (1.2mm. 1.6mm) depth of topping concrete(85mm. 90mm). support condition(simple, 2-span), shear reinforcment(studs), span(2.7m, 3.0m, 3.3m. 3.6m. 3.9m) and shear span(L/3, L/4, L/7). We analyzed the structural behavior of composite slab throughout the moment-curvature relationship which is obtained with the program using the computer language. Turbo C. From this development for slab system, the reinforced concrete or steel structure building may be easy, economical for construction, And informations about the structural behavior of composite slabs will be utilized to established korea standard.

  • PDF

Study on Fatigue Behavior and Rehabilitation of Stringer with Coped Section(I) -Experimental Study on Static and Fatigue Behavior- (절취부를 갖는 세로보의 피로거동과 보수·보강에 관한 연구(I) -정적거동 및 피로거동의 실험적 고찰-)

  • Hwang, Yoon Koog;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.363-375
    • /
    • 1997
  • This study encompasses the performance of static and fatigue test for the 8 large scale test specimens to clarify the fatigue behavior of coped stringer and the effect of the repair and strengthening on the damaged stringer of the floor system in steel railway bridges. For the purpose of the research, the actual stress wave for the existing bridge was measured, the basic stress range frequency histogram was made and the equivalent stress range was calculated. Using the result from the equivalent stress range made by adjusting the stress range, the static and fatigue test was carried out by identifying the previous rehabilitation and after. As the result of the static tests, it was revealed that the level of local stress under the S1 specimen test of the real equivalent stress range was similar to tensile strength of the test material, and it was consistent with the requirement of the initiation condition of the fatigue crack. Through the various rehabilitation methods to the damaged specimens, the effects of the repair and reinforcement were analyzed. According to the results of the repair of effect, bolting the high tension bolt over the stop hole was confirmed to be more adequate method than drilling only stop hole to delay the fatigue crack growth. Futhermore, in case of the stringer subjected by bending moment, the reinforcement over the upper flange side was determined to be a useful strengthening method, and the reinforcement to the web of the stringer was not appropriate to accomodate as a adequate strengthening method. Also it was confirmed that the category of the fatigue design for the coped stringer met with the category E specified on the fatigue design criteria of the Highway Standard Specification in Korea.

  • PDF

Deflection Evaluation of the Constructing-load Carrying Capacity for Deep Decking Floor System Reinforced with Both Ends Cap Plates (캡 플레이트로 단부 보강한 춤이 깊은 데크의 시공중 처짐성능평가)

  • Jeon, Sang Hyun;Kyung, Jae Hwan;Kim, Young Ho;Choi, Sung Mo;Yang, Il Seung
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.155-167
    • /
    • 2015
  • If of application of the deep deckting floor in long span more than 6m, the deflection caused by the construction load occurred high. Because the constructing-works and safety by this deflection, take actually supports to laborers working on the deck. However, installed supports are having difficultly such as the restricted passage, deficiency of working space, and lowering of efficiency. And toward-opening deck is seen as local buckling of web plate, flexural-torsional buckling, and gradually opening of corrugated decking. In this study, we will suggest a deep decking floor system that reinforced with both ends cap plates for toward-opneing decking change from opening to closing. The constructing deflection of a deep decking more than 6m must be satified 30mm and L/180 as proposed. Full-scale field tests loading by sand conducted a deep decking reinforced with and without cap plate. In conclusion, the specimen reinforced with cap plates have shown that to ensure the negative moment $wl^2/18$. And constructing-deflection of deep decking shown that to satisfy the evaluation value (L/180 or 30mm).

Flexural Strength of Composite HSB Girders in Positive Moment (HSB 강합성거더 정모멘트부의 휨저항강도)

  • Cho, Eun-Young;Shin, Dong-Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.389-398
    • /
    • 2010
  • The flexural strength of composite HSB I-girders under a positive moment was investigated using the moment-curvature analysis method to evaluate the applicability of the current AASHTO LRFD design specifications to such girders. A total of 2,391 composite I-girder sections that satisfied the section proportion limits of the AASHTO LRFD specifications was generated by the random sampling technique to consider a wide range of section properties. The flexural capacities of the sections were calculated inthe nonlinear moment-curvature analysis in which the HSB600 and HSB800 steels were modeled as an elasto-plastic strain-hardening material, and the concrete, as a CEB-FIP model. The effects of the ductility ratio and the compressive strength of the concrete slab on the flexural strength of the composite girders made of HSB and SM520-TMC steels were analyzed. The numerical results indicated that the current AASHTO LRFD equation can be used to calculate the flexural strength of composite girders made of HSB600 steel. In contrast, the current AASHTO LRFD equation was found to be non-conservative in its prediction of the flexural strength of composite HSB800 girders. Based on the numerical results of this study for 2,391 girders, a new design equation for the flexural strength of composite HSB800 girders in a positive moment was proposed.