A Study on the Dehumidification Control to Prevent Condensation for Radiant Floor Cooling (바닥복사냉방의 결로방지를 위한 제습제어에 관한 연구)

  • 김용이;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 2003
  • In the forming of an integrated system of radiant floor cooling and dehumidifying, chilled coil can be used for cooling and dehumidification. Therefore, it is necessary to find the efficient control method which can eliminates latent load efficiently. This study has been conducted to find this method by dividing the dehumidification system into 3 types according to the control variables and analyzing characteristics of each system. To prevent the floor surface condensation, the amount of condensation can be manipulated by water temperatures, water flow rates in chilled coil, and air flow rates passing by it. So dehumidification system control can be divided into constant air flow control and variable air flow control. Regarding dehumidification control, variable air flow control, which eliminates latent load rather than sensible load, is preferable to constant flow control.

A Study on the Thermal Environmental Analysis and the Application of Radiant Floor Cooling in Apartment Building (공중주택의 열환경분석과 바닥복사냉방의 적용에 관한 연구)

  • 김용이;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.541-548
    • /
    • 2001
  • The objective of this study is to analyze the possibilities and considerations for the application of the radiant floor cooling system by analyzing the problems of a conventional cooling system through field tests and thermal performance simulations of the radiant floor cooling in an apartment building. The results are as follows. (1) Problems of he conventional cooling system with PAC()packaged air conditioner)'s include draft, local discomfort, and excessive electrical peak demand. (2) According to the measurement during the cooling and intermediate seasons, the floor surface temperatures which are experienced at the time of cooling with PAC\`s and during intermediate season are similar to the temperatures for radiant floor cooling. (3) The radiant floor cooling system is applicable to apartment buildings during the cooling season, especially on hot and clear days.

  • PDF

A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구)

  • 임재한;여명석;양인호;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

A Study on the System Integration and Control Method of Radiant floor Cooling in Apartment Buildings (공동주택에서 바닥복사냉방의 시스템 구성과 제어 방안에 관한 연구)

  • 조영흠;석호태;김광우;여명석
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.107-115
    • /
    • 2004
  • The objective of this study is to show the system Integrations and control method for operation of the Radiant Floor Cooling. The systems for radiant floor cooling system consist of only using the radiant floor cooling and the radiant floor cooling integrated with a dehumidification system. And the study is suggested control method with composed radiant floor cooling system through simulations. Radiant floor cooling systems compose of four main parts: an existing radiant heating panel, manifold, cooling source and controller, and sensors. If dehumidifying or supplementary cooling is needed, additional equipments such as PAC and AHU are needed. Simulation results show that control method only using radiant floor cooling system can prevent condensation and set room air temperature with the exception of hot and humid periods and control method using the radiant floor cooling integrated with a dehumidification system is comfort thermal environments and can reduce the cooling load quickly, moreover, show comfort control method to meet various cooling operation situations.

An Experimental Study on the Application of Polypropylene Capillary Tube Cooling System (폴리프로필렌 모세유관 냉방시스템의 적용에 관한 실험적 연구)

  • Lee Young-Ju;Jin Wu-feng;Yeo Myoung-Souk;Kim Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.873-881
    • /
    • 2005
  • In this study, we made RFC, RCC and NCC according to the method by which polypropylene capillary tube was adopted, and evaluated cooling performance of each system through model experiments. We also investigated an applicability of the combined use of radiant cooling and dehumidification system. The results are as follows: In case of normal cooling load, RFC and RCC maintained set temperature without a condensation. But, in case of peak cooling load, RFC and RCC resulted in the lack of cooling performance and caused a condensation at the radiation surface. Consequently, the only use of polypropylene capillary tube is considered not to be enough for cooling in real application. Using the combination of a dehumidification and radiant cooling system maintained the set temperature without a condensation. NCC kept the set temperature at anytime without a condensation. It is more economic than packaged air-conditioner system due to the cooling effect of the floor surface.

An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification (제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구)

  • 이상엽;황석호;김가현;이승복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.

A Study on the Control of Water Flow and Water Temperature in the Radiant Cooling System through Simulations (시뮬레이션을 통한 바닥복사냉방 시스템의 공급유량 및 냉수온도 제어에 관한 연구)

  • 김용이;윤혜림;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.532-540
    • /
    • 2001
  • The objectives of this study are to analyze the control variables according to condensation occurrence, to find the range in floor surface temperature and frequency of condensation, and to evaluate the control methods through simulations when the radiant heating system is used for cooling. Through the simulation analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The results show that the lowest floor surface temperature is around $23^{\circ}C$, the surface condensation can be prevented by controlling indoor humidity within 20g/kg(DA0, and that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구)

  • 김용이;임재한;한여명;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

A Study on the Application of the Radiant Floor Cooling System in Residential Building (주거 건물의 복사냉방시스템 적용에 관한 연구)

  • 임재한;여명석;김광우
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.73-82
    • /
    • 2004
  • The objective of this study is to demonstrate the potential of radiant cooling systems using Ondol as an alternative cooling system in residential buildings. For this purpose, computer simulation and model experiments have been performed for the system performance analysis regarding comfort, floor surface condensation, and supply water temperature. The results of this study is the following: In radiant floor cooling system, room air temperatures were maintained within the set temperature range of $\pm$1$^{\circ}C$ without any discomfort condition. And taking into account only the condensation occurrence, it was possible to achieve radiant floor cooling for a period of about 77% of the total cooling period in weather condition of Seoul. The minimum supply water temperature is about 15$^{\circ}C$, so renewable energy system such as ground heat exchange system can be used as an alternative in cooling source. Also, floor surface condensation can be prevented by integrating with the dehumidification system.