• Title/Summary/Keyword: 바닥면적

Search Result 140, Processing Time 0.03 seconds

Effects of Different Floor Space and Type on Performance, Behaviour and Carcass Quality of Finishing Pig (돈방바닥 면적과 형태가 비육돈의 생산과 행동 및 도체품질에 미치는 영향)

  • Kim, Doo Hwan;Ha, Duck Min;Song, Jun Ik;Jeon, Jung Hwan
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.165-172
    • /
    • 2012
  • This study was designed to determine the effect of different floor space and type of finishing building on performance, behaviour and carcass quality of finishing pig. Three hundred and thirty six finishing pigs were alloted into two space allowance ($1.0m^2$and $2.5m^2$/pig) and two floor type (concrete slat and bedded with sawdust) of finishing building. There was no significant difference between the different space allowance in the body gain, feed intake and feed per gain. And also floor type of finishing building was not affected by the performance of finishing pig. Space allowance per pig affected the maintenance behaviour, but there was no significant difference between the floor type of finishing building in the spent time on lying, sitting and standing. Floor type was affected by the occurrence of standing behaviour, the finishing pigs in the bedded with sawdust showed less occurrence of standing. Carcass traits did not show any significant difference due to the difference of space allowance and floor type of finishing building. There was no significant difference in the chemical compositions of pork loin between the space allowance and floor type of finishing building.

A heating apparatus for semiconductor manufacturing using direct heating method (직접가열방식을 이용한 반도체 제조용 히팅장치)

  • Jung, Soon-Won;Kwon, Oh-Joen;Koo, Kyung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2218-2219
    • /
    • 2008
  • 본 연구는 반도체 기판 히팅 장치의 새로운 구조에 관한 것으로 기판의 바닥면에 밀착된 가열 플레이트층의 직접가열 구조에 따른 빠른 열 응답성 및 열손실 최소화를 이룰 수 있다. 또한 가열 플레이트층에 내장된 히팅 수단인 시즈히터의 접촉면적을 늘려 가열 유효면적 증가와 같은 효과를 갖는다. 이를 위해 감광막이 코팅된 기판과, 상기 기판의 바닥면에 밀착되는 가열 플레이트층, 절연 및 열손실을 최소화하기 위해 상기 가열 플레이트층의 바닥면에 밀착되는 운모층, 상기 운모층의 하부에 밀착되어 바닥 플레이트층으로 이루어지되, 상기 가열 플레이트 층은 바닥면 전체에 걸쳐 연속되는 홈부를 형성하고, 상기 홈부로는 기판을 가열하기 위한 시즈히터가 삽입되어 구성된다. 새로운 기판 히팅 구조를 사용하여 시간 경과에 따른 가열 플레이트의 온도 변화를 확인 한 결과, 간접가열방식인 기존 방식에 비해 약 40 %의 전력 절감효과가 있는 것으로 확인 되었다.

  • PDF

Probabilistic Analysis of Lifetime Extreme Live Loads of Multi-Story Columns (고층기둥 축하중의 사용기간 최대값에 대한 확률론적 분석)

  • 김상효;박흥석
    • Computational Structural Engineering
    • /
    • v.5 no.3
    • /
    • pp.113-118
    • /
    • 1992
  • The live loads acting on structures are generally computed in terms of equivalent uniformly distributed loads for the simplicity in design process. The loads, therefore, tend to decrease with increasing influence area in both load intensity and variance. Since multi-story column loads result from accumulation of loadings action on several different floors, its influence area becomes wider and lifetime maximum decreases. In the design codes proposing the design loads according to types of structural members(i.e., slabs, beams, columns), rather than the change of influence area, some proper reduction factors are given for columns which support more than one floor. Using the live load models developed for columns supporting single floor, in this study, the probabilistic characteristics of multi-story column loads are analyzed. In addition reduction factors given for multistory columns in current practice are calibrated.

  • PDF

Probabilistic Analysis of Lifetime Extreme Live toads of Multi-Story Columns (고층기둥 축하중의 사용기간 최대값 분석)

  • 김상효;조형근;배규웅;박홍석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1990.10a
    • /
    • pp.69-72
    • /
    • 1990
  • The live loads acting on structures are generally computed in terms of equivalent uniformly distributed loads for the simplicity in design process. The loads, therefore, tend to decrease with increasing influence area in both load intensity and variance. Since multi-story column loads result from accumulation of loadings acting on several different floors, its influence area becomes wider and lifetime maximum decreases. In the design codes proposing the design loads for types of structural members (i.e., slabs, beams, columns), not for tile change of influence area, some proper reduction factors are given for columns which support more than one floor. Using the live load models developed for colons supporting single floor, in this study, the probabilistic characteristics of multi-story column loads are analyzed. In addition reduction factors given for multi-story columns in current practice are calibrated.

  • PDF

Design of Three Tier Cropping Systems in Greenhouse Using The Sun Light (자연광을 이용한 3단 재배 시스템의 설계)

  • 김기성;김문기;권혁진
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.04a
    • /
    • pp.92-95
    • /
    • 1999
  • 재배시설내의 재배면적은 온실의 경우 벤치의 구성 방법에 따라서 차이는 있으나 바닥 면적의 47-68% 정도로 전체 면적에 비하여 생산에 사용되는 면적의 효율이 높지 못한 편이다(Langhans, 1990). 이러한 재배면적을 최대로 확보하여 단위 면적당 생산량을 높이기 위한 연구가 자동화 온실이나 식물공장을 중심으로 진행되고 있다. 이러한 연구는 많은 성과를 거두고 있으나 인공광을 이용하거나, 부가적인 기계화 장비나 자동화 설비가 필요하여 에너지 비용과 시설비용이 무시 못 할 정도이며, 고도의 제어기술이 요구되고 있어 상업용으로 보급되지 못하고 있다. (중략)

  • PDF

A Comparative Study of Floor Area and Average Distance of Nurse Working of Planned Courtyard in Ward (중정이 계획된 병동부 바닥면적과 간호동선 평균거리 비교 연구)

  • Kim, Jea Won;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.2
    • /
    • pp.7-16
    • /
    • 2019
  • Purpose: The courtyard in the ward can light and ventilate in the central space and corridor of the ward. It is possible to improve the disadvantages of the existing double-corridor ward. Also, there is the advantage in that patients are able to contact with nature indoors and cause positive activities. So, the purpose of this study is quantitatively analyze the floor area and the average distance of nurse working of the courtyard in ward. Methods: The subjects are converted through the same criteria setting. And it investigate and analyze the influence of the courtyard in the ward through the analysis of the spatial composition. Result: The factors that affected the floor area increase are the planning courtyard, the corridor type and the dispersion of the medical rooms. The average distance of nurse working is more influenced by the nursing management system of the hospital than by the courtyard. So, It can improve according to the position and number of nurse station. Implications: It can be used as a primary data for courtyard plan in the ward for positive patient environment plan considering the floor area, average distance of nurse working.