• Title/Summary/Keyword: 바닥두께

Search Result 223, Processing Time 0.028 seconds

Structural Performance of Pre-tensioned Half-depth Precast Panels (프리텐션 반두께 바닥판을 갖는 바닥판의 구조성능 평가)

  • Kim, Dong Wook;Shim, Chang Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1707-1721
    • /
    • 2014
  • Half-depth panels were developed with the merits of CIP (Cast In Place) decks and precast decks for constructability and fast construction. In this paper, details of half-depth panels with pre-tensioning were suggested. For evaluation of structural performance, five half-depth panel specimens were fabricated and static tests were conducted. The cross-sections of these specimens were composed of pre-tensioned half-depth panels and pre-tensioned two-span half-depth panels. Test parameters were the amount of the prestressing force and the longitudinal reinforcements. Static tests on simply-supported slabs showed that ultimate strength was 1.55 times greater than calculated nominal strength. The flexural strength was only 10 % increased and the influence on crack width control was negligible when the member of tendons was increased twice. For two-span continuous specimens, the ultimate strength increased 1.2 times and 1.38 times respectively as the reinforcement was additionally provided. The verified half-depth panels by this research can be effectively utilized for the fast replacement or construction of bridges.

Probability Based Determination of Slab Thickness Satisfying Floor Vibration Criteria (수직진동 사용성 기준을 고려한 바닥판 두께 제안)

  • Lee Min-Jung;Nam Sang-Wook;Han Sang-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.687-694
    • /
    • 2005
  • In current design practice, the thickness of the floor slab has been determined to satisfy requirement for deflection control. However, previous study shows that the floor thicknesses in residential buildings may not satisfy the floor vibration criteria, even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. This study attempts to propose slab thickness for flat plate slab systems that satisfies floor vibration criteria against occupant induced floor vibration(heel drop load). Two boundary conditions(simple and fixed support), three square flat plates(4, 6, 8m), and five concrete strength($18\~30$ MPa) are considered. Since there are large uncertainties in loading and material properties, probabilistic approach is adopted using Monte-Carlo simulation procedures.

Minimum Design Thickness of Prestressed Concrete Deck Slabs for Composite Two-Girder Bridges (강합성 2거더교 프리스트레스트 바닥판의 설계 최소두께)

  • Hwang, Hoon Hee;Joh, Changbin;Kwark, Jong Won;Lee, Yong Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.183-190
    • /
    • 2006
  • Minimizing the self weight of long-span deck slabs is one of the key factors for the practical and economic design of a composite two-girder bridge. In this paper, the minimum design thickness and rebar details of prestressed concrete deck slabs for composite two-girder bridges with girder span length from 4 m to 12 m are studied based on the safety and serviceability. The bridge deck slab with minimum thickness is designed as a one-way slab considering orthotropic behavior. Then fatigue safety of the deck slab is examined. Serviceability requirements for the deck slab such as deflection and crack width limits are also examined. The result shows that rebars with diameter less than 16 mm is recommended for the improved fatigue behavior, and, for the deck slab with span length longer than 8 m, the deflection limit governs the minimum design thickness. The result also shows that, for the deck slab with span length longer than 4 m, the distribution rebar requirement in the current Korea Highway Bridge Design Code is not sufficient to maintain the structural continuity in bridge axis as expected from the deck slab with span length shorter than 3 m.

A Efficient Vibration Analysis Method for the Cooncrete-Steel Deck Slab (콘크리트와 강제데크의 합성 바닥판의 실용적인 진동해석 방법)

  • Kim, Gee-Cheol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.4 s.18
    • /
    • pp.91-100
    • /
    • 2005
  • Composite slab structures consisted with steel deck plate and concrete material show generally anisotropic structural behavior because of different stiffness between the major direction and sub-direction of deck plate, and also the structures can be regarded as the laminated slab structures. It is necessary for the composite deck slab structures to carry out the exact vibration analysis to evaluate the serviceability. Also, it is needed to evaluate the exact structural behavior of composite deck slab with a layered orthotropic materials. In this paper, the thickness of topping concrete and deck plate are used to calculate the material coefficient stiffness of a sub-direction, and an equivalent depth calculated from sectional stiffness of concrete and deck plate is applied to get the stiffness of a major direction. The stiffness of two layered composite plates with different depth is determined by laminated theory. It is concluded that the presented method can efficiently analyze the structural behavior of composite deck slab consisted with steel deck plate and concrete material in the practical engineering field.

  • PDF

Fatigue strength of stud shear connector considering bedding layer thickness in precast deck composite bridges (프리캐스트 바닥판 합성형 교량에서의 베딩층의 두께를 고려한 전단연결재의 피로강도)

  • Ryu, Hyung Keun;Shim, Chang Su;Chung, Chul Hun;Chang, Sung Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.113-120
    • /
    • 2002
  • A shear connection in composite bridges with precast decks has considerable characteristics different from cast-in-place deck bridges such as shear pocket and bedding layer. Thus, it is necessary to build design basis of the shear connector in precast decks through the experiments. In order to estimate fatigue life of shear connector in precast deck bridges, push-out fatigue tests were conducted with parameter, bedding layer thickness. As a result of the tests, failure modes of shear connector were observed. Consequently, empirical S-N curve equations of stud shear connector in precast deck bridges were proposed in this paper.

Effect of abdominal drawing in maneuver with pelvic floor exercise on abdominal muscle thickness measured by ultrasonography (골반 바닥근육 운동을 이용한 복부 드로잉-인이 초음파 측정 방법을 이용한 복부 근육 두께에 미치는 영향)

  • Choi, You-Jeong;Son, A-Reum;Hong, Ji-Heon;Yu, Jae-Ho;Kim, Jin-Seop;Lee, Dong-Yeop
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.7
    • /
    • pp.93-100
    • /
    • 2019
  • The purpose of this study is to measure abdominal muscle thickness when Pelvic Floor contraction (PFC) and Abdominal Drawing-In Maneuver (ADIM) were separately applied and combined exercise was applied and to compare the effects of the exercise. After the pre-investigation, the subjects were given a explanation of the purpose and the method of the research and then an experiment was conducted targeting a total of 30 subjects, who voluntarily agreed with this. Thicknesses of internal oblique (IO), transverse abdominis (TrA) and external oblique (EO) were measured during a break and then three types of exercise. All the measured values of the experiment were processed using Repeated measure ANOVA, and Bonferroni method was applied. As a result, the three types of exercise showed significant differences in thicknesses of IO, TrA and EO. In conclusion, the subjects had the thickest muscles and muscular activity increased during PFC+ADIM, compared to PFC and ADIM.

Effect of Low Temperature Annealing on the Magnetoresistance in Co/Cu Artificial Superlattice (Co/Cu인공초격자에서 저온 열처리가 자기저항에 미치는 영향)

  • 민경익;송용진;이후산;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.4
    • /
    • pp.305-309
    • /
    • 1993
  • Thermal stability of Co/Cu artificial superlattice (AS) prepared by RF-magnetron sputtering and the effect of low temperature annealing on the magnetoresistance of the AS have been investigated in this work. Dependence of annealing behavior on the Cu spacer thickness, Fe underlayer thickness, and kind of the underlayer was examined and the relationship between the interfacial reaction and magnetoresistance was studied. It turned out that when Co/Cu AS was annealed at low temperature ($<450^{\circ}C$), the magnetoresistance could increase in the case of AS with thick spacer Cu ($20~25\AA$) layer, whereas it decreased in the case of AS with thin spacer Cu ($7\AA$) layer, which of the former is in contrast with previous reports and the latter in consistent with them. The increase of magnetoresistance is due to increase of interfacial atomic sharpness, which is supported by low angle X-ray diffraction analysis. The thermal stability of Co/Cu AS was better in the case of thick Fe underlayered AS. Interfacial reaction (separation of intermixed Co and Cu) could be observed at lower temperature for (200)-textured samples than for (111)-textured samples, which can be interpreted in terms of interdiffusion kinetics depending on the crystallographic orientation.

  • PDF

Analysis of a Pin Fin with Variable Fin Base Thickness (핀 바닥두께가 변하는 pin 핀의 해석)

  • Kang, Hyung-Suk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.642-645
    • /
    • 2008
  • A pin fin with variable fin base thickness is analysed by using the one dimensional analytic method. Heat loss and fin thermal resistance are presented as a function of the fin base thickness, pin fin outer radius and convection characteristic numbers ratio. The relationship between the fin outer radius and fin base thickness for the same amount of heat loss is shown. One of the results indicates the fin thermal resistance decreases as the fin outer radius and/or convection characteristic numbers ratio increase whereas the fin thermal resistance is independent on the variation of fin base thickness.

  • PDF

Formulation and Application of UV-Cured Anti-cigar burning Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 내열 코팅액의 제조 및 응용에 관한 연구)

  • Park, Bo-Ram;Ha, Jin-Wook
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.84-87
    • /
    • 2009
  • 본 연구는 건축용 바닥재로 널리 이용되는 PVC 상재의 표면을 열에 의한 손상으로부터 보호하기 위하여 기존에 사용하는 광경화형 우레탄-아크릴 수지에 내열성(anti-cigar burning)을 향상시킨 광경화형 수성도료 개발에 관한 것이다. PVC 바닥상재용으로 사용되는 내열기능성이 없는 우레탄-아크릴 수지에 인계화합물을 주원료로 합성한 내열재, 구아니딘을 주원료로 합성한 내열재, 일시적 방염제로 사용되는 제 2인산암모늄을 수지의 양 대비 함량(wt%)을 10, 20, 30%로 변화하여 첨가한 후 배합하여 수지의 내열성을 향상시킨 코팅액을 제조하였다. 제조한 코팅액은 코팅층의 두께조절이 가능한 Bar-coating을 사용하여 PVC 바닥상재에 코팅한 후, 내열성, 부착력, 내화학성, 코팅두께 등의 코팅층 표면물성을 평가하였다. 연구결과, 수지에 인계화합물을 주원료로 합성한 내열재 30%를 혼합하여 제조한 코팅액을 Bar-coater No.12로 코팅한 코팅표면이 열에 의한 손상이 가장 적고, 부착력 100%, 내화학성 양호로 가장 좋은 물성을 보였다. 전반적으로 내열재 함량이 높고 코팅 두께가 두꺼울수록 내열성이 우수한 것으로 나타났다.

  • PDF

Formulation and Application of UV-Cured Hard Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 하드 코팅액의 제조 및 응용에 관한 연구)

  • Park, Bo-Ram;Yoon, Hyun-Jung;Hong, Zhao;Ha, Jin-Wook
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.878-881
    • /
    • 2009
  • 본 연구는 건축자재로 널리 사용되는 PVC 바닥상재의 표면을 스크래치로부터 보호하기 위하여 기존에 사용하는 광경화형 우레탄-아크릴 수지에 내마모성을 향상시킨 광경화형 하드 코팅액 개발에 관한 것이다. PVC 바닥상재용으로 사용되는 내마모성이 없는 우레탄-아크릴 수지에 $Al_2O_3$(Al-160SG-3), $Al_2(OH)_3$(SH-8W) 및 $SiO_2$(KS-5000) 등 서로 다른 내마모성을 지닌 물질을 분말 형태로 수지의 양대비 함량(wt%)을 10~30%로 변화하여 첨가한 후 링밀(Ring Mill)을 사용, 배합하여 수지의 내마모성을 향상시킨 하드 코팅액을 제조하였다. 제조한 하드 코팅액은 코팅층의 두께조절이 가능한 코팅(Bar-coating)을 사용하여 PVC 바닥상재에 코팅 한 후 내마모성, 연필경도, 부착력, 코팅두께 등의 코팅층 표면물성을 평가하였다. 연구결과, 수지에 $Al_2O_3$ 분말 30%를 혼합하여 제조한 하드 코팅액이 내마모성 1등급, 연필경도 H, 부착력 100%로 가장 좋은 물성을 보였으며, 전반적으로 입자크기가 작고, 분말 함량이 많을수록 또한 코팅두께가 두꺼워 질수록 경도 및 내마모성이 우수한 것으로 나타났다.

  • PDF