• Title/Summary/Keyword: 미활용 열에너지

Search Result 8, Processing Time 0.026 seconds

A Study on Residents' Acceptance of Unutilized Heat in District Heating (미활용 열에너지의 집단에너지 주민 수용성에 관한 연구)

  • Doo Hwan Won;Saesin Oh
    • Environmental and Resource Economics Review
    • /
    • v.32 no.3
    • /
    • pp.191-215
    • /
    • 2023
  • This study focuses on evaluating and comparing residents' acceptance of unutilized heat such as hydrothermal energy and waste heat from waste incineration and data centers in the case that they are used as district heat sources. This is because securing residents' acceptance is significantly important in order for unutilized heat to be considered as a heat source of district heating and cooling to achieve neutrality in the heating and cooling sector. A survey of heating consumers' perception on unutilized heat energy is conducted and a conjoint model is used to analyze the willingness to pay of heating consumers on incineration heat, water heat, and data center waste heat and to compare them with existing gas heat sources. As a result of the analysis, it is confirmed that district heating using hydrothermal energy and data center waste heat is preferred to district heating from heat from a natural gas plant or waste incineration.

Binary Power plant using unused thermal energy and Neural Network Controllers (미활용 열에너지를 이용한 바이너리 발전과 신경망 제어)

  • Han, Kun-Young;Park, Sung-Dae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1302-1309
    • /
    • 2021
  • Recently, the Korean Government announced the Korean New Deal as a national development strategy to overcome the economic recession from the pandemic crisis and lead the global action against structural changes. In the Korean New Deal, the Green New Deal related with the energy aims to achieve net-zero emissions and accelerates the transition towards a low-carbon and green economy. To this end, the government plans to promote an increased use of renewable energy in the society at large. This paper introduces a binary power generation using unused low-grade thermal energy to accelerate the transition towards a low-carbon and green economy and examines a control system based on Neural Network which is capable maintenance at low-cost by an unmanned automated operation in actual power generation environment. It is expected that the realization of binary power generation accelerates introduction of renewable energy along with solar and wind power.

Compact Binary Power plant using unused thermal energy and Neural Network Controllers (미이용 열에너지를 이용한 소형 바이너리 발전과 신경망 제어기)

  • Han, Kun-Young;Jeong, Seok-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.557-560
    • /
    • 2021
  • In the face of the COVID-19 pandemic, the Korean Government announced the Korean New Deal as a national development strategy to overcome the economic recession from the pandemic crisis and lead the global action aginst sturctural changes. The Green New Deal related with the energy aims to achieve net-zero emissions and accelerates the transition towards a low-carbon and green economy. To this end, the government plans to promete an increased use of renewable energy in the the society at large. This paper introduces a compact-binary power plant using unused thermal energy and a control system based on Neural Network in order to accelerate the transition towards a low-carbon and green economy. It is expected that he compact-binary power plant accelerate introduction of renewable energy along with solar and wind power.

  • PDF

Case-study of the technological trajectory through the technology-product-industry road map -CDRS technology of using Unutilized Energy (기술-제품-산업연관도를 이용한 기술 경로의 사례조사 -CDRS의 미활용 에너지 이용 기술)

  • 전지훈;안은영;허은녕
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.613-616
    • /
    • 2003
  • 우리나라의 에너지 수요면에서 살펴보면 가정 및 상업부문은 냉난방, 급탕용 에너지수요의 급증으로 높은 증가율을 보일 전망이다. 냉난방, 급탕용 에너지수요는 10$0^{\circ}C$ 미만의 비교적 중저온이며, 이러한 열수요에 대해 수백도에서 천도 이상의 온도를 얻을 수 있는 화석연료의 연소에 의해 공급하는 것은 에너지ㆍ환경면에서 불합리하다. 또한 도시지역내에서 외부로 배출되고 있는 각종 온도의 열에너지는 도시환경의 저해하고 있어, 에너지절약과 도시환경을 위해 미활용에너지의 이용에 대한 관심이 증가하였다.(중략)

  • PDF

A Basic Experimental Study on the Heat Energy Harvesting for Green SOC (녹색 사회기반시설의 열 에너지 하베스팅을 위한 기초실험 연구)

  • Jo, Byung-Wan;Lee, Duk-Hee;Lee, Dong-Yoon;Kim, Yoon-Ki
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.93-101
    • /
    • 2010
  • As the number of indispensable needs of clean energy increases due to the green new deal revolution, the possibility of heat energy harvesting from the surrounding infrastructures such as a railroad or highway was verified. In order to find more efficient usage of a heat source, the possibility of transforming heat into electricity were confirmed using Bi-Te type thermoelectric element, and electrical quality were tested with experiments of different heat source and environmental change in the surrounding infrastructures. After careful experiments, the possibility of collecting thermal energy and findings of the heat temperature change in infrastructrue are verified with a result of obtaining almost 20.82W in 70 celcius($^{\circ}C$) temperature differences and $1m^2$ surface area. Consequently, the ratio of heat temperatiure change and transforming surface area is the most crucial factor in the harvesting heat energy, and reducing thermal loss and improving thermal convection as well as transformation efficiency of thermoelectric element is required to get more efficient and durable generation.

Fabrication of Thermoelectric Module and Analysis of its Power Generation Characteristics (열전발전소자 제작 및 발전특성 분석)

  • Choi, Taeho;Kim, Tae Young
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.2
    • /
    • pp.90-97
    • /
    • 2021
  • In this study, a Bi2Te3 thermoelectric generator (TEG) was fabricated to convert unused thermal energy into useful electrical energy. For the performance test, a dedicated experiment device consisting of a heating block operating with cartridge heaters and a cooling block through which a refrigerant flows was constructed. A 3×3 array of thermocouples was mounted on the heating block and the cooling block, respectively, to derive the temperature fields and heat transfer rate onto both sides of the TEG. Experiments were conducted for a total of 9 temperature differences, obtaining V-I and P-R curves. The results of 7 variables including Seebeck coefficients that have a major effect on performance were presented as a function of the temperature difference. The feasibility of the energy recovery performance of the developed TEG was verified from the maximum power output of 7.5W and conversion efficiency of 11.3%.

A Study on the Influence of Urban Environment on the Generation of Thermal Diseases (도시 환경이 온열질환 발생에 미치는 영향에 관한 연구)

  • Lee, Su-Mi;Kweon, Ihl;Kim, Yong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.84-92
    • /
    • 2019
  • The deterioration of the urban heat environment due to climate change and the occurrence of heat-related diseases have emerged as one of the major social problems. This has led to more research on climate change, including heat waves, but it is mainly focused on climate factors. However, the urban heat island phenomenon accelerates the summer heat wave, and the increasing trend of heat-related patients in urban areas suggests the impact of the city's environment. Thus, this study analyzed the effects of physical and social characteristics of urban areas on heat-related patients in Seoul and Gyeonggi-do. The analysis showed that the ratio of the total area of residential, commercial and industrial facilities, the main source of heat energy locality, among the land use statuses, was not statistically significant, but the road area and the green area were found to have a positive and negative The population density and the percentage of people aged 65 or older, the percentage of people living alone and the proportion of people receiving basic living were all shown to be significant, with only the ratio of elderly living alone and the ratio of population density having negative effects. The results of the study can be used to develop urban policy alternatives related to local warming patients.

A Study on the Utilization of potential heat sources for Heat Pumps to District Heating System in Urban (도시 내 지역난방 Heat Pump용 잠재열원 이용에 관한 연구)

  • Oh, Kwang Min;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.841-855
    • /
    • 2018
  • The purpose of this study is to estimate the available potential heat source for heat pump in the district heating supply area in the city. Unused energy potentials were estimated and integrated based on open source based data. In particular, geographical spatial analysis of recoverable heat energy density and heat demand in the heat source area of large retailers and public sauna facilities in the DH network located in the southern part of the metropolitan area (Pyeongtaek-si) was conducted. As a result of the study, the DH network area had a total potential energy of 1,741.7 toe/year for the two heat sources of large retailers and public saunas. It is estimated that 1,006.9 toe/year, which is 57.8% of the total, can be linked to the district heating. The large retailers showed a positive correlation with the floor area and energy use of 0.4937. The recoverable energy intensity was estimated to be $0.0017toe/m^2$ per unit area and $0.0069tCO_2/m^2$ for greenhouse gas emissions. In addition, public saunas were analyzed by comparing the empirical case with the theoretical calculation, and it was estimated that energy conservation estimate of 80% was $0.0315toe/m^2$ per bath area and $0.1183tCO_2/m^2$ for greenhouse gas emissions. The total potential energy amount of this area was positively correlated with the heat demand of apartment house by administrative district, and it was confirmed that it had a relatively high potential energy especially in traffic and commercial center.