• 제목/요약/키워드: 미소 신호 안정도

검색결과 43건 처리시간 0.022초

계통 운전조건에 따른 축 비틀림 전동 미소신호안정도 해석 (Analysis of Small Signal Stability for SSR on Generator Loading Condition)

  • 김동준;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.85-87
    • /
    • 2002
  • The paper describes the formulation of state matrix equations from the linearized multi-machine power system including network dynamics and the application of IEEE First Benchmark Model. The eigenvalues of IEEE First Benchmark Model are investigated not only by changing the compensation of series capacitance at no-load conditions, but also by varying the generator loading at fixed compensation of capacitance. In addition, the pure electrical self-excited mode is also examined by an eigen analysis and time domain simulation.

  • PDF

무효전력보상기를 이용한 미소신호안정도 개선방안에 관한 연구 (A Study on the Small-Signal Stability Improvement Method Using Static Var Compensator)

  • 이수현;노규민;김덕영;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1064-1066
    • /
    • 1997
  • This paper proposes an efficient algorithm of designing PSS and CSS. First, the stabilizer input variable is selected using the participation matrix. Secondly, the stabilizer constants are decided using first order eigenvalue sensitivity. The proposed method was validated to sample power system.

  • PDF

PSS 정수 튜닝을 위한 전력시스템 미소신호 안정도 해석 프로그램 (Computer Analysis Program of Small-Signal Stability of Power System for Tuning PSS′s parameters)

  • 김동준;문영환;허진;신정훈;김태균;추진부
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.241-249
    • /
    • 2003
  • This paper describes a novel approach for performing eigenvalue analysis and frequency domain analysis of multi-machine power system. The salient feature of this approach is a direct approach for constructing the state matrix equations of linearized power systems about its operating point using modular technique. These state matrix equations are then used to obtain eigenvalues and mode shapes of the system, and frequency response, or Bode, plots of selected transfer functions. The proposed program provides a flexible tool for systematic analyses of tuning PSS's parameters. The paper also presents its application to the analyses of a single-machine infinite bus system and two-area system with 4 machines.

GTO 제어 STATCOM을 포함하는 이산 전력시스템의 RCF 해석법에 의한 진동모드 해석 (Analysis of Oscillation Modes in Discrete Power Systems Including GTO Controlled STATCOM by the RCF Method)

  • 김덕영
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.829-833
    • /
    • 2007
  • In this paper, the RCF method is applied to analyze small signal stability of power systems including GTO controlled parallel FACTS equipments such as STATCOM. To apply the RCF method in power system small signal stability problems, state transition equations of generator, controllers and STATCOM are presented. In eigenvalue analysis of power systems, STATCOM is modelled as the equivalents voltage source model and the PWM switching circuit model. As a result of simulation, the RCF method is very powerful to calculate the oscillation modes exactly after the switching operations, and useful to analyze the small signal stability of power systems with periodically operated switching devices such as STATCOM.

SVC의 스위칭 동작에 의해 발생되는 진동현상의 미소신호 안정도 해석 (Small signal stability analysis of oscillations caused by switching operations of SVC)

  • 김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.495-497
    • /
    • 2005
  • A new small signal stability analysis method for eigenvalue analysis is presented. This method is called RCF method and based on the computation of the state transition equations and state transition matrix over a specified time interval that corresponds to one or some cycle operations of the system. This method is applicable to any system with or without switching elements. As an applicable example of RCF method in power system, the one machine infinite bus system connected switching SVC at generator terminal is investigated and the results proved that variations of oscillation modes after switching operations can be calculated exactly.

  • PDF

불연속 동작특성을 갖는 전력계통의 RCF법을 사용한 미소신호 안정도 해석 : 상태천이 방정식으로의 모델링 (Small signal stability analysis of power systems with non-continuous operating elements by using RCF method : Modeling of the state transition equation)

  • 김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.342-344
    • /
    • 2004
  • In conventional small signal stability analysis, system is assumed to be invariant and the state space equations are used to calculate the eigenvalues of state matrix. However, when a system contains switching elements such as FACTS devices, it becomes non-continuous system. In this case, a mathematically rigorous approach to system small signal stability analysis is by means of eigenvalue analysis of the system periodic transition matrix based on discrete system analysis method. In this research, RCF(Resistive Companion Form) method is used to analyse small signal stability of a non-continuous system including switching elements'. Applying the RCF method to the differential and integral equations of power system, generator, controllers and FACTS devices including switching elements should be modeled in the form of state transition matrix. From this state transition matrix eigenvalues which are mapped to unit circle can be calculated.

  • PDF

공진조건을 이용한 미소신호 안정도 해석 (Analysis of Small Signal Stability Using Resonance Conditions)

  • 조성진;장길수;윤태웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.535-543
    • /
    • 2002
  • Modern power grids are becoming more and more stressed with the load demands increasing continually. Therefore large stressed power systems exhibit complicated dynamic behavior when subjected to small disturbance. Especially, it is needed to analyze special conditions which make small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability and operating conditions can be identified well using node-focus point and 1:1 resonance point. Also, the weak point which limits operating range is found by the analysis of resonance condition, and it is shown that reactive power compensation may solve the problem in the weak points. The proposed method is applied to test systems, and the results illustrate its capabilities.

계통의 종합적 미소신호 안정도 해석 알고리듬과 ATC 산정에의 응용에 관한 연구 (A Unified Framework for Small Signal Stability Analysis of Power Systems and Its Application to Available Transfer Capability)

  • 김상암;송화창;이병준;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1222-1230
    • /
    • 1999
  • This paper presents the framework for analysis of small-signal stability. In this framework the equilibrium points of system DAE model are traced using continuation method and instability points are determined on the solution path. Especially Implicit shift QR-modified Arnoldi method is utilized to calculated the rightmost eigenvalues. Small-signal stability is becoming one of the major factors that affect the ATC in the environment of deregulation. Stability limited ATC is easily evaluated in this stability analysis process.

  • PDF

대규모 전력계통의 미소신호 안정도 해석을 위한 선형해석 프로그램 개발 (Development Of Small Signal Stablility Linear Analysis Program for Large Scale Power System.)

  • 송성근;남해곤;심관식;김용구;김동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1054-1056
    • /
    • 1999
  • It is the most important in small signal stability analysis of large scale Power systems to compute only the dominant eigenvalues selectively with numerical stability and efficiency. In this Paper evoluted linear analysis program, transformed state matrix using Inverse transformation with complex shift and then Hessenberg process and iterative scheme are used to accelerate Hessenberg process, can calculate dominant eigenvalues. In this Paper, The accuracy of this Program has been validated against 4-machines 11-bus system and New England 10-machines 39-bus system. Also applied to KEPCO system - about 791-bus 250-machines 2500-branches, got 2568 order state matrix, and calculated two dominant modes. This analysis result equaled to result of EPRI's SSSP program to use commonly, and calculating time is faster.

  • PDF

전력계통의 미소신호 안정도 해석에서 계산시간 단축에 관한 연구 : 크러스터링 기법에 대하여 (The reduction of computer time in small-signal stability analysis in power systems : with clustering technique)

  • 권세혁;김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.138-140
    • /
    • 1992
  • This paper represents how to reduce the computer time in small signal stability analysis by selecting the dominant oscillation modes with frequency of 0.5 to 1.2 Hz using the clustering technique. Clustering technique links the buses which are expected to be similar with zero-impedance lines and the voltage variations of these buses are regarded to be identical. The computer time was reduced remarkably with this technique and the effect of clustering will be powerful in the analysis of large-scale power systems.

  • PDF