• 제목/요약/키워드: 미소신호 안정도

검색결과 43건 처리시간 0.031초

불연속 동작특성을 갖는 전력계통의 RCF법을 사용한 미소신호 안정도 해석 : 상태천이 방정식으로의 모델링 (Small signal stability analysis of power systems with non-continuous operating elements by using RCF method : Modeling of the state transition equation)

  • 김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.342-344
    • /
    • 2004
  • In conventional small signal stability analysis, system is assumed to be invariant and the state space equations are used to calculate the eigenvalues of state matrix. However, when a system contains switching elements such as FACTS devices, it becomes non-continuous system. In this case, a mathematically rigorous approach to system small signal stability analysis is by means of eigenvalue analysis of the system periodic transition matrix based on discrete system analysis method. In this research, RCF(Resistive Companion Form) method is used to analyse small signal stability of a non-continuous system including switching elements'. Applying the RCF method to the differential and integral equations of power system, generator, controllers and FACTS devices including switching elements should be modeled in the form of state transition matrix. From this state transition matrix eigenvalues which are mapped to unit circle can be calculated.

  • PDF

공진조건을 이용한 미소신호 안정도 해석 (Analysis of Small Signal Stability Using Resonance Conditions)

  • 조성진;장길수;윤태웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.535-543
    • /
    • 2002
  • Modern power grids are becoming more and more stressed with the load demands increasing continually. Therefore large stressed power systems exhibit complicated dynamic behavior when subjected to small disturbance. Especially, it is needed to analyze special conditions which make small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability and operating conditions can be identified well using node-focus point and 1:1 resonance point. Also, the weak point which limits operating range is found by the analysis of resonance condition, and it is shown that reactive power compensation may solve the problem in the weak points. The proposed method is applied to test systems, and the results illustrate its capabilities.

계통의 종합적 미소신호 안정도 해석 알고리듬과 ATC 산정에의 응용에 관한 연구 (A Unified Framework for Small Signal Stability Analysis of Power Systems and Its Application to Available Transfer Capability)

  • 김상암;송화창;이병준;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1222-1230
    • /
    • 1999
  • This paper presents the framework for analysis of small-signal stability. In this framework the equilibrium points of system DAE model are traced using continuation method and instability points are determined on the solution path. Especially Implicit shift QR-modified Arnoldi method is utilized to calculated the rightmost eigenvalues. Small-signal stability is becoming one of the major factors that affect the ATC in the environment of deregulation. Stability limited ATC is easily evaluated in this stability analysis process.

  • PDF

대규모 전력계통의 미소신호 안정도 해석을 위한 선형해석 프로그램 개발 (Development Of Small Signal Stablility Linear Analysis Program for Large Scale Power System.)

  • 송성근;남해곤;심관식;김용구;김동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1054-1056
    • /
    • 1999
  • It is the most important in small signal stability analysis of large scale Power systems to compute only the dominant eigenvalues selectively with numerical stability and efficiency. In this Paper evoluted linear analysis program, transformed state matrix using Inverse transformation with complex shift and then Hessenberg process and iterative scheme are used to accelerate Hessenberg process, can calculate dominant eigenvalues. In this Paper, The accuracy of this Program has been validated against 4-machines 11-bus system and New England 10-machines 39-bus system. Also applied to KEPCO system - about 791-bus 250-machines 2500-branches, got 2568 order state matrix, and calculated two dominant modes. This analysis result equaled to result of EPRI's SSSP program to use commonly, and calculating time is faster.

  • PDF

전력계통의 미소신호 안정도 해석에서 계산시간 단축에 관한 연구 : 크러스터링 기법에 대하여 (The reduction of computer time in small-signal stability analysis in power systems : with clustering technique)

  • 권세혁;김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.138-140
    • /
    • 1992
  • This paper represents how to reduce the computer time in small signal stability analysis by selecting the dominant oscillation modes with frequency of 0.5 to 1.2 Hz using the clustering technique. Clustering technique links the buses which are expected to be similar with zero-impedance lines and the voltage variations of these buses are regarded to be identical. The computer time was reduced remarkably with this technique and the effect of clustering will be powerful in the analysis of large-scale power systems.

  • PDF

RCF법을 사용한 미소신호 안정도 해석방법 (Small signal stability analysis using RCF method)

  • 김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.94-97
    • /
    • 2002
  • A new small signal stability analysis method for eigenvalue analysis is presented. The method is based on the computation of the transition matrix over a specified time interval that corresponds to one cycle operation of the system The method is applicable to any system with or without nonlinear elements. An applicable example of RCF method is presented and the eigenvalues are compared with those of the conventional state space method to show the exactness of the computed eigenvalues of the new method. Also, the variations of oscillation modes which were caused by the switching operation can be analyzed exactly using RCF method.

  • PDF

공진 조건을 이용한 미소신호 안정도 해석 (Analysis of small signal stability using resonance condition)

  • 조성진;장길수;윤태웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.109-111
    • /
    • 2001
  • Modern power grids are becoming more and more stressed with the load demands increasing continually. Therefore large stressed power systems exhibit complicated dynamic behavior when subjected to small disturbance. Especially, it is needed to analyze special conditions which make small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability and operating conditions can be predicted well using node-focus point and 1:1 resonance point. Also, the weak point which limits operating range can be identified by the analysis of resonance condition. The proposed method is applied to test systems, and the results illustrate its capabilities.

  • PDF

한전 전력계통의 저주파 진동현상 요인분석;양수발전기 기동시 (Analysis of the Factors Affecting Low-Frequency Oscillations in KEPCO Power System` With Pumped-Storage Plant)

  • Kil Yeong Song;Sae Hyuk Kwon;Kyu Min Ro;Seok Ha Song
    • 대한전기학회논문지
    • /
    • 제41권8호
    • /
    • pp.841-849
    • /
    • 1992
  • In power system operation, the stability of synchronous machine has been recognized one of the most important things. AESOPS program developed by EPRI in U.S.A. is a frequency domain analysis program in power system stability and it computes the electro-mechanical oscillation mode. This paper presents how to analyze the power system small signal stability problem efficiently by uusing the AESOPS program and analyze the various factors affecting the damping characteristics of these oscillations in KEPCO power system of 1986 with pumped-storage plant. To reduce the computing time and efforts, selecting the poorly-damped oscillation mode and clustering technique have been used. The characteristics of load, the amount of power flow on the transmission line and the gain of exciter have a significant effects on the damping of the system while the governing system has only a minor one. With the Power System Stabilizers, the stability of the power system has been improved.

  • PDF

미소혈관 내 백혈구 운동의 검출법 (Detection Method of Leukocyte Motions in a Microvessel)

  • 김응규
    • 융합신호처리학회논문지
    • /
    • 제15권4호
    • /
    • pp.128-134
    • /
    • 2014
  • 본 연구에서는 시공간 영상 해석을 이용한 미소혈관내 백혈구 운동의 검출 방법을 제안한다. 혈관벽에 부착하는 백혈구 운동은 영상내 혈관벽의 윤곽선을 따라 움직이는 것으로 시각화될 수 있다. 제안 방법에서 백혈구는 혈관벽의 윤곽선을 따라 움직인다는 구속조건을 사용하며 시공간 영상 해석방법의 사용에 의해 백혈구 운동을 검출한다. 생성된 시공간 영상은 특수한 목적의 방향 선택 필터에 의해 처리되고 후속의 분류처리가 행해진다. 이 후속의 분류처리는 단순한 임계값 및 윤곽선 처리에 의해 획득된 모든 성분중에서 백혈구 궤적 성분을 선택하고 분류한다. 실험 결과, 제안 방법은 복수개의 백혈구 흔적이 서로 교차할 때에도 백혈구 운동을 안정하게 검출할 수 있음을 보여준다.

시계열 데이터를 이용한 새로운 온라인 미소신호안정도 평가 방법과 적용 (A New Method for Assessing On-line Small-signal Stability and its Application)

  • 김동준;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.387-389
    • /
    • 2006
  • This paper describes new on-line small signal stability assessment and its application using the time series simulated phasor measurement data. Using FFT technique and optimization method, the suggested method can effectively identify all of mode frequencies involved in measured data and calculate the damping ratio with accuracy.

  • PDF