• Title/Summary/Keyword: 미세전자기계시스템 센서

Search Result 9, Processing Time 0.032 seconds

Study of the Respiratory Monitoring System by Using the MEMS Acceleration Sensor (MEMS 가속도 센서를 이용한 환자 호흡동작 모니터링 체계 연구)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Kim, Dong Wook;Shin, Dong Oh
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • In this study, we developed and evaluated the patient respiration training method which can help to avoid the problems for the limitation of RGRT applicable patient cases. By using the MEMS (micro-electro-mechanical-system) acceleration sensor, we measured movement of motion phantom. We had compared the response of MEMS with commercially introduced real time patient monitoring (RPM) system. We measured the response of the MEMS with 1 dimensional motion phantom movement for 2.5, 3.0, 3.5 second of period and the 2.0, 3.0, 4.0 cm of the amplitudes. The measured period error of the MEMS system was 0.6~6.0% compared with measured period using RPM system. We found that the shape of MEMS signals were similar with RPM system. From this study, we found the possibility of MEMS as patient training system.

High-Performance Multimodal Flexible Tactile Sensor Capable of Measuring Pressure and Temperature Simultaneously (압력과 온도측정 기능을 갖는 고성능 플렉시블 촉각센서)

  • Jang, Jin-Seok;Kang, Tae-Hyung;Song, Han-Wook;Park, Yon-Kyu;Kim, Min-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.8
    • /
    • pp.683-688
    • /
    • 2014
  • This paper presents a high-performance flexible tactile sensor based on inorganic silicon flexible electronics. We created 100 nm-thick semiconducting silicon ribbons equally distributed with 1 mm spacing and $8{\times}8$ arrays to sense the pressure distribution with high-sensitivity and repeatability. The organic silicon rubber substrate was used as a spring material to achieve both of mechanical flexibility and robustness. A thin copper layer was deposited and patterned on top of the pressure sensing layer to create a flexible temperature sensing layer. The fabricated tactile sensor was tested through a series of experiments. The results showed that the tactile sensor is capable of measuring pressure and temperature simultaneously and independently with high precision.

A Study on the Microstructure Properties of $SnO_2$ Gas Sensors Fabricated by Sol-Gel Method (졸-겔법으로 제작된 $SnO_2$ 가스센서의 미세구조 특성에 관한 연구)

  • Jang, K.U.;Kim, M.H.;Lee, W.J.;Lee, H.S.;Kim, T.W.;Chung, D.H.;Ahn, J.H.;Lee, S.I.;Kim, S.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.102-105
    • /
    • 2005
  • 가스센서는 응용 분야와 기능 및 종류가 다양하고 최첨단 분야로서 학문적으로는 물리, 화학, 전기, 전자 및 기계 등의 배경을 필요로 하며 산업적으로는 공업 전 분야와 농림, 축산, 사무기기에서 뿐만 아니라 공해 방진용(자동차 연소제어 및 배출가스 제어, 대기오염 감시등), 민생용(조리, 환기, 공조 등), 교통 보안용(음주운전측정 및 음주운전 방지장치 등), 방재용(가스 누설 탐지기, 불완전 연소 방지, 산소 결핍, 화재 등), 의료용(호기, 마취가스의 분석 등) 매우 광범위하며 점점 더 확대되어 가고 있다. 본 연구에서는 검출 가스 종류에 따라 졸-겔법으로 감응막을 최적 설계하고, 최적으로 설계된 감응막을 디핑법으로 코팅처리한 후 최적으로 열처리하여 센서를 제작하였다. 또한, 자체 제작한 가스검출 시스템에 제작된 센서를 장착하여 센서의 가스 검출 특성을 측정하고, 측정 데이터를 이용하여 휴대용 가스 검출 시스템을 설계 제작하였다.

  • PDF

Numerical Investigation of Temperature Uniformity and Estimation Accuracy for MEMS-based Black Body System (MEMS 기반 흑체 시스템의 온도 균일도 및 추정 정확도의 수치 해석적 검토)

  • Chae, Bong-Geon;Kim, Tae-Gyu;Lee, Jong-Kwang;Kang, Suk-joo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.5
    • /
    • pp.455-462
    • /
    • 2016
  • Output Characteristics of the spaceborn image sensor such as infrared(IR) sensor are varied according to time elapses and sensor repetition on/off operation. As a result, the quality of IR sensor image is decreased. Therefore, spaceborne image sensor require a periodic calibration using a black body system by correcting a non-uniformity of the sensor. In this paper, we proposed a MEMS-based black body system that can implement the high temperature uniformity at various standard temperatures ranging from low to high temperature and easily estimate the representative surface temperature. In addition, it has advantages lightweight, low-power and high accuracy. The feasibility of the proposed MEMS-based black body system was verified through the thermal analysis.

A Consideration on the Process Technology and Application of MEMS to prepare for upcoming MEMS-based technological paradigm (MEMS 기반의 새로운 기술적 패러다임에 대비한 공정 기술 분석 및 적용에 대한 고찰)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.7
    • /
    • pp.979-986
    • /
    • 2013
  • Recently, in the electric, electronic, robotic, and medical industries, a great attention has been paid to the development of MEMS-based smart devices with a compact size and highly intelligency. The MEMS technology is very effective in designing into a compact size and lightweight by combining into one the complex electrical, mechanical, chemical, and biological features which are required by smart devices, and at the same time, in bulk batch manufacturing. Therefore, this study, to prepare for upcoming new MEMS-based technological paradigm, analyzes MEMS processes and then considers its Applications.

Adaptive Pressure Sensor with High Sensitivity and Large Bandwidth Based on Gallium Microdroplet-elastomer Composite (갈륨 미세입자 탄성 복합체 기반 고민감도와 광대역폭을 갖는 가변 강성 압력센서)

  • Simok, Lee;Sang-Hyuk, Byun;Steve, Park;Joo Yong, Sim;Jae-Woong, Jeong
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.423-427
    • /
    • 2022
  • A pressure sensor that mimics the sensing ability of human skin has emerged as high-profile technology because it shows remarkable applications in numerous fields such as robotics, human health monitoring, and artificial prosthetics. Whereas recent pressure sensors have achieved high sensitivity similar to that of human skin, they still show limited detection bandwidth. Moreover, once these e-skin are fabricated, their sensitivity and stiffness are fixed; therefore, they can be used for only limited applications. Our study proposes a new adaptive pressure sensor built with uniform gallium microdroplet-elastomer composite. Based on the phase transition of gallium microdroplets, the proposed sensor undergoes mode transformation, enabling it to have a higher sensitivity and wider detection bandwidth compared with those of human skin. In addition, we succeeded in extending a single adaptive pressure sensor to sensor arrays based on its high uniformity, reproducibility, and large-scale manufacturability. Finally, we designed an adaptive e-skin with the sensor array and demonstrated its applications on health monitoring tasks including blood pulse and body weight measurements.

Fabrication and Evaluation of the SnO2 Based Gas Sensor for CO and NOx Detection (SnO2를 이용한 CO 및 NOx 가스 감지 센서 제작 및 특성 연구)

  • Kim, Man Jae;Lee, Yu-Jin;Ahn, Hyo-Jin;Lee, Sang Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.5
    • /
    • pp.515-523
    • /
    • 2015
  • In this paper, we fabricated and evaluated the gas sensor for the detection of CO gas and $NO_X$ gas among the vehicle exhaust emission gasses. The $SnO_2$ (tin dioxide) layer is used as the detection material, and the thin-film type and the nano-fiber type layers are deposited with various thicknesses using sputtering method and electro spinning method, respectively. The experiments are performed in the chamber where the gas concentration is controlled with mass flow controller. The fabricated devices are applied to the CO and $NO_X$ gas, where the device with the thinner $SnO_2$ layer shows better sensitivity. The nano-fiber has the larger surface area, and the shorter response time and recovery time are obtained. From the experimental results, both types of gas sensors successfully detect CO and $NO_X$ gases, which can be applied to measure those gases from the vehicle emissions.

Membrane Based Triboelectric Nanogenerator: A Review (막 기반 마찰전기 나노 발전기: 총설)

  • Rabea Kahkahni;Rajkumar Patel
    • Membrane Journal
    • /
    • v.33 no.2
    • /
    • pp.53-60
    • /
    • 2023
  • Mechanical energy can be harvested by triboelectric nanogenerators (TENG) from biological and environmental systems. In wearable electronics, TENG has a lot of significance as biomechanical energy can be harvested from the motion of humans, which is applied in vibrational sensors. Wearable TENG is prone to moisture and polytetrafluoroethylene (PTFE) is an excellent hydrophobic material used in these applications. The presence of highly electronegative fluorine atoms leads to very low surface energy. At the same time, the performance of the device increases due to the efficient capture of the electrons on the microporous membrane surface. This similar behavior occurs with polyvinylidene fluoride (PVDF) due to the presence of fluoride atoms, which is relatively less as compared to PTFE.

Low Temperature Sintering of PNN-PZT Ceramic for Piezoelectric Generator and Its Piezoelectric Properties (압전 발전시스템 개발을 위한 PNN-PZT 세라믹스의 저온소결 및 압전특성 평가)

  • Lee, Myung-Woo;Kim, Sung-Jin;Yoon, Man-Soon;Ryu, Sung-Lim;Kweon, Soon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.306-306
    • /
    • 2008
  • 기계적 에너지를 전기적 에너지로 변환하는 에너지 변환소자인 압전 세라믹스는 액추에이터, 변압기, 초음파모터, 초음파 소자 및 각종 센서로 응용되고 있으며, 그 응용분야는 크게 증가하고 있다. 최근에는 이러한 압전 소자를 앞으로 도래하는 ubiquitous, 무선 모바일 시대의 휴대용 전자제품, robotics, MEMS 분야 등의 대체 에너지원으로 응용하기 위한 연구가 진행되고 있다. 특히 인간의 걷기 운동 등과 같은 일상적인 동작으로 필요한 전력을 얻을 수 있고, 세라믹 소자를 이용하기 때문에 전자노이즈가 발생되지 않을 뿐 아니라 반영구적으로 사용할 수 가 있어서, 기존 이차전지를 대체 또는 보완 할 수 있는 방안도 검토되고 있다. PZT계 세라믹스는 높은 유전상수와 우수한 압전특성으로 전자세라믹스 분야에서 가장 널리 사용되어지고 있지만 $1200^{\circ}C$ 이상의 높은 소결온도 때문에 $1000^{\circ}C$ 부근에서 급격히 휘발되는 PbO로 인한 환경오염과 기본조성의 변화로 인한 압전 특성의 저하가 문제시 되고 있다. 또한 적층 세라믹스의 제작 시 구조적 특성상 내부전극이 도포된 상태에서 동시 소결이 필요한데, 융점이 낮은 Ag전극 대신 값비싼 Pd나 Pt가 다량 함유된 Ag/Pd, Ag/Pt 전극이 사용되고 있어 경제성이 떨어지는 단점을 갖게 된다. 순수 Ag 전극을 사용하거나 Ag의 비율이 높은 내부전극을 사용하기 위해서는 $900^{\circ}C$ 이하에서 소결되고 우수한 전기적 특성을 보이는 압전 세라믹스를 개발 하는 것이 필요하다. 따라서 본 연구에서는 압전특성이 우수한 $(Pb_{1-x}Cd_x)(Ni_{1/3}/Nb_{2/3})_{0.25}(Zr_{0.35}/Ti_{0.4})O_3$ 계의 조성을 설계하고, 소걸온도를 낮추기 위해서 2 단계 하소법을 이용하였다. 또한 $MnCO_3$, $SiO_2$, $Pb_3O_4$ 등을 소량 첨가하여 액상 소결 특성을 부여하여 소결 온도를 감소시키려는 시도도 하였다. 분말을 볼 밀링 (ball milling)을 통해 24시간 동안 혼합하고, 혼합된 분말은 $800^{\circ}C$에서 2시간 동안 하소하였다. 하소한 분말을 다시 72시간 동안 볼 밀링 하여 최종 분말을 얻었다. 최종 분말에 PVB를 첨가하여 직경 15mm의 디스크 형태로 성형한 후, 850~$975^{\circ}C$ 범위에서 온도를 변화시키면서 소결을 하였다. 최종 분말 및 소결된 시편을 XRD분석을 통하여 상을 확인하였고, SEM을 이용하여 미세조직을 관찰 하였다. 전기적 특성을 평가하기 위하여 두께를 1mm로 연마한 시편에 Ag 전극을 도포하여 $650^{\circ}C$에서 열처리한 후, 분극처리 하였다. 압전특성은 $d_{33}$-meter로 측정하였고, impedance analyzer를 이용하여 압전 특성 (전기기계결합계수 및 기계적품질계수)을 측정 하였다. 또한 강유전체 특성 평가 장치 (Precision-LC)를 이용하여 분극-전계 특성을 평가하였다. 이상의 연구를 통하여 소결 온도가 $900^{\circ}C$인 경우에서도 양호한 압전 특성을 확보 할 수 있었다.

  • PDF