• Title/Summary/Keyword: 미세전류자극

Search Result 41, Processing Time 0.047 seconds

Effect of Microcurrent stimulation and Combined exercise on Body composition and Blood lipid profile in Young obese women (미세전류자극과 복합운동이 비만 여대생의 체성분과 혈중지질성분 변화에 미치는 효과)

  • Yong-Taek Rhim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.1104-1115
    • /
    • 2023
  • The present study aims to verify the usefulness of microcurrent stimulation as an effective intervention for managing body shape. Thirty female college students with a percentage body fat of 30% or more participated as subjects and belonged to the one of three groups; control group, combined exercise group, microcurrent stimulation group. Based on the results of analyzing the measurement data from pre- and post-intervention for four weeks for each group, the following conclusions were obtained. There was no statistically significant difference in all measured variables in the control group. However, waist circumference and TC were significantly reduced in the combined exercise group, and also weight, percentage body fat, waist circumference, and apolipoprotein were significantly reduced in microcurrent stimulation group. Considering the above conclusions, it can be suggested that microcurrent stimulation could be an effective intervention to improve body composition and blood lipid profile to have a healthy body.

Effects of Microcurrent and High Voltage Pulsed Galvanic Current Stimulation on Fibular Fracture Healing of the Rabbits (미세전류자극과 고전압 맥동직류 통전이 토끼의 비골 골절치유에 미치는 효과)

  • Ko, Seung-Hyun;Yoon, Bum-Chul;Kim, Ji-Sung;Min, Kyung-Ok
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.286-292
    • /
    • 2011
  • This study investigated the degree of fracture healing using cathode stimulation of microcurrent, cathode and anode stimulation of High Voltage Pulsed Galvanic Current (HVPGC). Measures were performed by X-ray test and Hematoxylin-Eosin stain and Masson's trichrome stain and osteocalcin-positive immunoreactivity. In the measure of X-ray, microcurrent stimulation group revealed more rapid recovery than the groups of HVPGC's cathode and anode stimulation in bone union degrees. Microcurrent group showed significant difference statistically (p<0.05). However, the groups of HVPGC's cathode and anode stimulation didn't show significant difference statistically(p>0.05). In the histologic examination with Hematoxylin-Eosin and Masson's trichrome, microcurrent stimulation group was observed more proliferation of irregular woven bones than the groups of HVPGC's cathode and anode stimulation. Osteocalcin-positive immunoreactivity was observed more osteoblast, osteocyte, osteoclast, bone matrix than the groups of HVPGC's cathode and anode stimulation. Microcurrent stimulation can be considered an effective way during healing of fresh fracture and it can show more effective method than HVPGC's cathode and anode stimulation in the fracture healing.

The Effects of Microcurrent Stimulation on Erector Spinae Fatigue Index (미세전류 자극이 척주세움근의 피로지수에 미치는 영향)

  • Kang, Da-Haeng
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.545-551
    • /
    • 2013
  • This study aimed to compare the effects of microcurrent stimulation and rest on the fatigue index by applying both to subjects who had accumulated fatigue after performing short-duration physical activity. The experiment was performed at S University from December 2012 to February 2013, on 22 healthy men in their 20s, who were right-handed, and without peripheral or musculoskeletal diseases. All subjects lifted a 10-kg box lift and lower 100 times in 15 minutes. Immediately after that, muscle fatigue index (Median Frequency: MF) and blood fatigue index (Creatine Kinase Lactate: CK, Lactate Dehydrogenase: LDH) were measured by using surface electromyography. The subjects were divided into two groups, and microcurrent stimulation and rest were mediated to the experimental and control groups, respectively, for 20 minutes. After intervention, muscle fatigue index and blood fatigue index were measured and the changes in the accumulated fatigue index were compared. Both groups manifested significantly decreased cumulative fatigue after applying the mediation compared to the pre-intervention level (p < .05), the only exception being the fatigue index of the left erector spinae in the rest group. Compared to the rest group, the microcurrent stimulation group showed a significant decrease in muscle fatigue index (p < .05) but no significant differences were found in the blood fatigue index. Given the results of this study, microcurrent stimulation is considered to be helpful in muscle fatigue recovery for workers who have to perform repetitive movements lifting weights, and additional studies on the correlations of the fatigue recovery with respect to the long-term follow-up of fatigue index and mediation time are necessary.

Effect of Microcurrent Therapy on Interleukin-6 Expression in Adjuvant Induced Rheumatoid Arthritis Rat Model (미세전류치료가 아주반트 유도 류마티스관절염 유발 흰쥐의 인터루킨-6 발현에 미치는 영향)

  • Lee, Hyun-Min;Lee, Sang-Yeol;Chang, Jong-Sung;Lee, Myoung-Hee;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.4
    • /
    • pp.551-558
    • /
    • 2010
  • 연구목적 : 미세전류 자극이 아주반트로 류마티스 관절염을 유발한 실험동물의 염증반응과 통증에 미치는 효과를 알아보기 위하여 실험동물의 발허리발가락관절내 염증반응 정도를 나타내는 인터루킨-6(interleukin-6)의 발현과 핫플레이트(hot plate)를 이용한 발도피지연시를 측정하여 미세전류의 효과에 대하여 알아보고자 하는데 목적이 있다. 연구방법 : 실험동물은 무작위로 대조군(n=18)과 미세전류를 적용한 실험군(n=18)으로 구분하였고, 각 군당 6마리씩 1일군, 7일군, 14일군으로 배정하였다. 류마티스 관절염 유발후 1일, 7일, 14일에 모든 실험동물의 열통각 역치를 나타내는 발도피지연시와 발허리발가락관절내 인터루킨-6의 발현정도를 측정하였다. 각 집단 내의 기간에 따른 발도피지연시와 인터루킨-6의 면역반응성은 일원배치 분산분석을 실시하였고, 사후분석으로는 Duncan의 다중범위검정을 실시하였다. 실험군과 대조군을 비교하기 위하여 독립표본 t-test를 실시하였다. 연구결과 : 실험결과는 다음과 같다. 1) 아주반트 주사 1일후, 실험군과 대조군에서 인터루킨-6 면역반응성과 발도피지연시는 비슷한 양상을 보였다. 2) 인터루킨-6 면역반응성은 아주반트 주사 7일, 14일 후 대조군이 실험군보다 유의하게 증가되었다(p<.05). 3) 발도피지연시는 아주반트 주사 7일, 14일 후 실험군이 대조군보다 유의하게 증가되었다(p<.05). 결론 : 이상의 결과로부터, 미세전류 자극이 아주반트로 유발된 류마티스관절염 모델에서 활액 조직내 염증반응을 감소시키고 열통각역치는 증가되는 것을 알 수 있었다.

Design of the Acupoint Discriminator(DM96A-2) by Improvement of Meridian Point Discrimination Parameter (경혈식별 파라메터의 개선에 의한 혈위식별시스템 DM96A-2의 설계)

  • 이후학;어윤기고수복정동명
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.825-828
    • /
    • 1998
  • 경혈을 대상으로 인체를 진단하는 의료기기들은 경혈점에 미세한 직류전류를 인가하고, 이 점에서의 전기저항과 세포의 분극에 의해 반응하는 경락체계의 균형상태를 측정하여 인체를 종합적으로 진단한다. 따라서 전 과정이 정확한 경혈의 위치에서 이루어져야만 치료효과와 진단의 신뢰성이 보장된다. 그러나 대부분의 경락관련 치료기들이 정확한 혈위식별에 어려움이 있고 사용자의 전문적 숙련을 요구한다. 따라서 선행연구에서 일정한 주파수로 교호되는 자극패턴(SPAC) 방식을 사용하여 식별률을 높인 혈위식별기 DM96A-1를 개발하였다. DM96A-1은 단일전원이 양방향으로 교호되는 전류로 자극펄스를 출력하고 측정범위가 0.5∼50㎂인 전류메터와 레벨메터를 이용하여 혈위의 전류량을 표시한다. 이에 따라 방향전환 소자의 두 채널 제어신호가 교호되는 과도기에서 두 자극패턴의 중첩 도통에 의해서 누설전류가 발생하는 경우가 있으며 이를 제거하기 위하여 정밀한 조정을 필요로 하는 불편이 있었다. 따라서 이와 같은 단점들을 보완하여 신뢰성 있는 출력 파라메터를 얻을 수 있도록 마이크로프로세서 i80c196kc를 사용하여 DM96A-2를 재 설계하였으며 임상실험에 의하여 개선된 최적 파라메터의 타당성을 검증하였다.

  • PDF

The effects of electrical current from a micro-electrical device on tooth movement (초소형 전기장치에 의한 미세 전류가 치아이동에 미치는 효과)

  • Kim, Dong-Hwan;Park, Young-Guk;Kang, Seung-Gu
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.337-346
    • /
    • 2008
  • Objective: The purpose of this study was to determine whether an exogenous electric current to the alveolar bone surrounding a tooth being orthodontically treated can enhance tooth movement in human and to verify the effect of electric currents on tooth movement in a clinical aspect. Methods: This study was performed on 7 female orthodontic patients. The electric appliance was set in the maxilla to provide a direct electric current of $20{\mu}A$. The maxillary canine on one side was assigned as the experimental side, and the other as control. The experimental canine was provided with orthodontic force and electric current. The control side was given orthodontic force only. Electrical current was applied to experimental canines for 5 hours a day. The amount of canine movement was measured with an electronic caliper every week. Results: The amount of orthodontic tooth movement in the experimental side during 4 weeks was greater by 30% compared to that of the control side. The amount of increase in tooth movement in the experimental side was statistically significant. The amount of tooth movement in the experimental side during the first two weeks was !Bleater than that in the following two weeks. The amount of weekly tooth movement in the control side was decreased gradually. Conclusions: These results suggested that the exogenous electric current from the miniature electric device might accelerate orthodontic tooth movement by one third and have the potential to reduce orthodontic treatment duration.

Effects of Non-Invasive Constant Microcurrent Stimulation on Expression of BMP-4 After Tibia Fracture in Rabbits (비침습식 미세전류자극이 토끼 경골의 골절 후 BMP-4 발현에 미치는 영향)

  • Cho, mi-suk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1124-1129
    • /
    • 2009
  • This study aims to examine the effects of non-invasive constant microcurrent stimulation on expression of Bone Morphogenetic Protein(BMP) 4 after tibia fracture in rabbits. Twenty four rabbits with tibia fracture were randomly divided into control and experimental groups. Each group was divided into four subgroups, based on the duration of the experiment (3, 7, 14, 28 days). The experimental groups received a constant microcurrent stimulation of $20{\sim}25{\mu}A$ intensity with surface Ag-AgCl electrode (diameter 1cm, Biopac, U.S.A.) for 24 hours a day. Cathode of the microcurrent stimulator located on the tibia directly, anode of it did on the gastrocnemius muscle. Rabbits were sacrificed on each of the postoperative days 3, 7, 14, 28. To investigate how non- invasive constant microcurrent stimulation affects bone healing, immunohistochemical analysis of BMP-4 was performed at each point. After evaluation, the test results are as follows: Comparisons of immunohistochemical observation of BMP-4 in 7 days after tibial fracture show that there was shown to be a moderate positive reaction (++) on concentric circles of Harversian system andt he interstitial lamella in the control group, while there was a very strong positive reaction (++++) on concentric circles of Harversian system and interstitial lamellain the experimental group. These results suggest that applying non-invasive constant microcurrent stimulation on fractured bone is helpful to bone healing.

  • PDF

The effects of microcurrent stimulation for gait improvement (미세전류 자극이 보행 개선에 미치는 효과)

  • Yu, Jae-Young;Jeong, Jin-Gyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.11
    • /
    • pp.1283-1290
    • /
    • 2014
  • This study was conducted to apply microcurrents of $500{\mu}A$ effective for ATP generation to leg muscles to which delayed onset muscle soreness (DOMS) had been induced in order to examine whether the microcurrent stimulation was effective for gait improvement. Forty subjects were randomly assigned to an experimental group of 20 subjects and a placebo group of 20 subjects. Microcurrents were applied immediately after inducing DOMS and 24 hours and 48 hours thereafter and changes in the center of pressure (COP), cadence, and affected stance phases were measured. According to the results of the measurement, changes in the COP, cadence, and affected stance phases at 48 hours after the induction of DOMS were statistically significant compared to the values before the induction. The COP of the experimental group became statistically significantly lower and the ratio of affected stance phases of the experimental group became statistically significantly higher compared to the placebo group at 48 hours after the induction of DOMS. Therefore, $500{\mu}A$ microcurrents showed effects for gait improvement by promoting the recovery and healing of damaged muscles.

Effects of Electrical Stimulation on the Nucleolar Organizer Region in Keratinocyte of Wounded Skin in Rat (전기자극이 흰쥐 창상 표피세포의 핵소체형성부위에 미치는 영향)

  • Lee Jae-Hyoung;Jekal Seung-Joo;Park Seung-Teack
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • The purpose of this study was to determine the effect of microamperage electrical stimulation on the number of argyrophilic nucleolar organizer region (AgNOR) in rat skin. Twenty four male Sprague-Dawley rats were divided into electrical stimulation and control group. Bach animals hair on the back was removed. The electrical stimulation group received an positive rectangular positive electrical stimulation with $500{\mu}A$, while the control group was given the same treatment without electricity. The rats were sacrificed at 4 and 7 day of stimulation, respectively. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with silver nitrate. The AgNOR were counted using a light microscope and computerized image analysis system and calculated as the mean number of AgNOR per nucleus in the epidermal keratinocyte. In control skin, the mean AgNOR count of epidermal keratinocyte at 4 and 7 day were 1.67 and 1.72, whereas electrical stimulated rat had mean AgNOR counts of 2.0 and 2.14, respectively. A Student's t-test showed a significantly higher mean AgNOR number at 4 ana 7 day in the electrical stimulated rats than control rats (p<0.05). The microamperage electric current stimulation increased the epidermal AgMOR expression in incisional wound skin. These results suggest that the microamperage electrical stimulation may promote migration and proliferative activity of epidermal keratinocyte in surgical wound.

  • PDF

A Comparison of the Inhibitive Effect of High Voltage Pulsed Current Stimulation and Microcurrent Electrical Neuromuscular Stimulation on Bacterial Growth (고전압 맥동전류 자극과 미세전류 신경근 자극의 세균성장 억제효과 비교)

  • Kang, Eun-Jin;Roh, Jung-Suk;Lee, Jae-Seung;Yi, Chung-Hwi;Kim, Tae-Ho
    • Physical Therapy Korea
    • /
    • v.3 no.1
    • /
    • pp.12-23
    • /
    • 1996
  • High Voltage Pulsed Current Stimulation(HVPCS) and Microcurrent Electrical Neuromuscular Stimulation(MENS) have been used to promote the healing of decubitus ulcer and surgical wounds. The benefits of HVPCS and MENS are thought to include an inhibitive effect on bacterial growth. The purpose of this study was to compare the inhibitive effect of two different electrical stimulation techniques growth in vitro. Using agarose-based media, the two bacterial species Staphylococcus aureus, Esherichia coli - which are commonly isolated from open wounds were incubated in an incubator for 24 hours following exposure to HVPCS(400 V, 120 pps, $70{\mu}s$) and MENS($100{\mu}A$, 0.3 Hz). We then measured the zone of inhibition around each electrode. Both HVPCS and MENS produced an inhibitive effect on bacterial growth in this vitro study. However MENS was more effective than HVPCS.

  • PDF