• Title/Summary/Keyword: 미세결합

Search Result 714, Processing Time 0.027 seconds

INFLUENCE OF SODIUM ASCORBATE ON MICROTENSILE BOND STRENGTHS TO PULP CHAMBER DENTIN TREATED WITH NAOCL (NaOCl로 처리된 치수강 상아질에서 sodium ascorbate가 미세인장결합강도에 미치는 영향)

  • Jeon, Soo-Yeon;Lee, Kwang-Won;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.545-552
    • /
    • 2008
  • The purpose of this study was to evaluate the influence of sodium ascorbate on microtensile bond strengths of total-etching adhesive system to pulp chamber dentin treated with NaOCl. Pulp chambers of extracted human non-caries permanent molars were treated as follows: group 1, with 0.9% NaCl; group 2, with 5.25% NaOCl; group 3, with 5.25% NaOCl and 10% sodium ascorbate for 1min; group 4, with 5.25% NaOCl and 10% sodium ascorbate for 1 min and 10ml of water; group 5, with 5.25% NaOCl and 10% sodium ascorbate for 5 min; group 6, with 5.25% NaOCl and 10% sodium ascorbate for 5 min and 10ml of water; group 7, with 5.25% NaOCl and 10% sodium ascorbate for 10 min; group 8, with 5.25% NaOCl and 10% sodium ascorbate for 10 min and 10ml of water. Treated specimens were dried, bonded with a total-etching adhesive system (Single bond), restored with a composite resin(Z250) and kept for 24h at 100% humidity to measure the microtensile bond strength. NaOCl-treated group (group 2) demonstrated significantly lower strength than the other groups. No significant difference in microtensile bond strengths was found between NaCl-treated group (group 1) and sodium ascorbatetreated groups (group 3-8). The results of this study indicated that dentin treated with NaOCl reduced the microtensile bond strength of Single bond. Application of 10% sodium ascorbate restored the bond strength of Single bond on NaOCl-treated dentin. Application time of sodium ascorbate did not have a significant effect.

A Study on the Transport of Microplastics Contained in the Wastewater of the King Sejong Station according to the Wave Effect (파랑 효과에 따른 세종과학기지 방류수에 포함된 미세플라스틱 이송에 관한 연구)

  • Kim, Bo-Kyung;Hwang, Jin Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.245-245
    • /
    • 2021
  • 해양으로 유출된 5 mm 이하의 크기로 분해된 미세플라스틱이 해양 환경 오염의 주요 원인으로 자리잡았다. 최근에는 청정해역으로 알려진 남극해에서도 발견되고 있어 남극해에 잔류하는 미세플라스틱 오염 수준을 이해하기 위해 노력하고 있다. 하지만, 파랑의 효과를 고려한 남극해의 해수 순환 구조와 미세플라스틱의 고유 특성을 반영한 미세플라스틱의 거동 및 공간적 분포에 대한 복합적 이해는 상대적으로 부족하다. 남극해에서 발견된 미세플라스틱은 과학기지들의 방류수나, 조사선 등과 같은 인위적인 활동으로 인해 집적될 수 있으며, 특히 영구적으로 거주하는 과학기지에서 흘려보내는 방류수에 포함된 미세플라스틱은 과학기지 주변 해수 오염에 직접적인 영향을 줄 것으로 예상된다. 따라서, 본 연구에서는 파랑 효과에 따른 남극 킹조지 섬(King George Island)에 위치한 세종과학기지의 방류수에 포함된 미세플라스틱의 이송에 대해 모의하였다. 세종과학기지가 위치한 킹조지 섬과 넬슨 섬(Nelson Island) 사이의 멕스웰 만(Maxwell Bay)의 해수 흐름을 재현하기 위하여 해수 유동 모델(Delft3D-FLOW)이 사용되었다. 또한, 해수 유동 모델에 파랑 모델(Delft3D-WAVE)을 결합하여 파랑의 효과가 미세플라스틱의 이송에 미치는 영향을 확인하였다. 세종과학기지의 방류수가 흘러나가는 마리안 소만(Marian Cove)의 유속장을 바탕으로 이송, 확산, 입자의 침강 속도를 고려하여서, 세종과학기지에서 밀물 시 방출한 입자를 라그랑지안 입자 추적(Lagrangian Particle Tracking) 방법을 이용해 추적하였다. 해수의 밀도보다 가벼운 플라스틱의 경우 해수 표층의 흐름을 따라 소만 내부로 이송되어 해안선에 도달하고, 해수의 밀도보다 무거운 플라스틱의 경우 소만 내부로 이송되나 입자의 침강 속도로 인해 방출 위치 근처에서 집적된다. 파랑의 효과를 고려하게 되면, 고려하기 전보다 두 종류의 미세플라스틱 모두 소만 내부로 더 멀리 이송되는데, 이는 파랑으로 인한 힘(wave-induced force)이 해수 유동 모델의 운동방정식에 추가되며 파랑 에너지 분산으로 인해 해수 흐름에 변화를 준 것으로 보인다.

  • PDF

EFFECT OF CAVITY DISINFECTANT ON THE BOND STRENGTH AND MICROLEAKAGE OF DENTIN BONDING AGENTS (와동 세척제가 상아질 결합제의 결합에 미치는 영향)

  • Song, Seung-Ho;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.595-603
    • /
    • 2005
  • Incomplete removal of bacteria contaminated dentin or enamel associated with caries is a potential problem in restorative dentistry Secondary or residual caries, pulpal inflammation and hypersensitivity may result from bacteria left after the initial preparation, especially if an adequate seal against microleakage is not obtained. A possible solution to eliminate residual bacteria left in a cavity preparation would be to treat the cavity with cavity disinfectant wash. But a potential problem with using a cavity disinfectant with dentin bonding agents could be their interference with the ability of the resin to bond to the tooth micromechanically. The purpose of this study was to evaluate the effect of 2% chlorhexidine containing cavity disinfectant ($Consepsis^{(R)}$) on shear bond strength and microleakage of dentin bonding agents, $Adper ^{TM}$ $Scotchbond^{TM}$ Multi-Purpose, $Adper^{TM}$ Single Bond and $Adper^{TM}\;Prompt^{TM}\; L-Pop^{TM}$ Sixty and sixty sound human third molar teeth, respectively, were used for shear bond strength and microleakage test. For experimental group, cavity disinfectant was applied before dentin bonding agents, and was not applied for the control group. The result from the this study can be summarized as follows ; 1. Use of 2% chlorhexidine containing cavity disinfectant($Consepsis^{(R)}$) does not significantly affect the shear bond strength of dentin bonding agents. 2. Use of 2% chlorhexidine containing cavity disinfectant($Consepsis^{(R)}$) does not significantly affect the microleakage of dentin bonding agents.

  • PDF

Wear Behaviors of WC-CoCr and WC-CrC-Ni Coatings Sprayed by HVOF (고속화염 용사법으로 제조된 WC-CoCr 코팅과 WC-CrC-Ni 코팅의 내마모 거동)

  • Lee, Seoung Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.204-211
    • /
    • 2020
  • The high-velocity oxy-fuel (HVOF) thermal spraying coating technique has been considered a promising replacement for traditional electrolytic hard chrome plating (EHC), which caused environmental pollution and lung cancer due to toxic Cr6+. In this paper, two types of cermet coatings were prepared by HVOF spraying: WC-CoCr and WC-CrC-Ni coatings. The produced coatings were analyzed extensively in terms of the micro-hardness, porosity, crystalline phase and microstructure using a hardness tester, optical microscopy, X-ray diffraction, and scanning electron microscopy (including energy dispersed spectroscopy (EDS)), respectively. The wear and friction behaviors of the coatings were evaluated comparatively by reciprocating sliding wear tests at 25 ℃, 250 ℃, and 450 ℃. The results revealed correlations among the microstructures, metallic binder matrixes, porosities, and wear performance of the coatings. For example, WC-CoCr coatings showed better sliding wear resistance than WC-CrC-Ni coatings, regardless of the test temperature due to the more homogeneous microstructure, Co-rich, Cr-rich metallic binder matrix, and lower porosity.

The Regulation Mechanisms of Kinesin Motor Proteins (Kinesin 모터 단백질의 조절 기전)

  • Park, Sang Jun;Seog, Joung-Su;Moon, Il Soo;Seog, Dae-Hyun
    • Journal of Life Science
    • /
    • v.27 no.7
    • /
    • pp.840-848
    • /
    • 2017
  • Proper intracellular transport is essential for normal cell function. Intracellular transport is mediated by microtubule-dependent molecular motor proteins, as well as kinesin and cytoplasmic dynein, which move their cargo along long, microtubule tracks in cells. Kinesins are ATP-dependent plus-end-directed motor proteins in the intracellular transport of organelles, vesicles, RNA complexes, and protein complexes. The mislocalization of these different types of cargo has been linked to cell dysfunction and degeneration. The cargo transport of kinesins can be described by the following steps: binding to the appropriate cargo and/or adaptor proteins, activation of the kinesin's motility and movement along the microtubule, and the release of the cargo at the correct destination. Recently, several studies have revealed the mechanisms for the regulation of kinesin motor activity, including cargo loading and unloading. Intracellular cargo transport is also modulated by adaptor proteins, which link the kinesins to their cargo. The regulatory proteins, which include protein kinases and phosphatases, regulate kinesin motor activity directly through the phosphorylation or dephosphorylation of kinesins and indirectly through the modification of adaptor proteins, such as c-Jun NH-terminal kinase-interacting proteins, or of the microtubule network. These findings lay the groundwork for understanding how kinesins are differentially engaged in intracellular cargo transport. In addition, understanding the regulatory mechanisms of each kinesin is an area of key interest within cell biology and neurophysiology. In this study, we reviewed kinesins' regulation proteins and discuss how their regulation affects cargo recognition and transport.

Study on Wet Electric Precipitation with Electrospray for Removal of PM1.0 in Exhaust Gas (배가스 내 PM1.0 미세먼지 제거를 위한 정전분무 습식 전기집진기에 대한 연구)

  • Cho, Yeonjoo;Lim, Hyunjeong;Kim, Soyeon;Choi, Sangmi;Jeong, Min Kyu;Kim, Minsung
    • Plant Journal
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2020
  • The need to improve the performance of the dust collector by increasing the fine dust pollution in Korea is eminent. In this study, electrostatic spray wet electrostatic precipitator is used to remove Particulate Matter (PM). In order to enter the Cone-jet mode, which is the most stable spray mode among the various modes of electrostatic spraying, an appropriate voltage-flow condition must be satisfied, and a voltage-flow interval enabling this can be expressed as Stability Island. The voltage at which the conduit mode starts in the Stability Island section is referred to as the electrostatic spray minimum voltage (Onset Voltage). However, the conventional electrostatic spray is uses a very low flowrate, at most few millilitres per minute. The use of much higher flowrates has introduced different patterns of electrospray modes. In this study, the different spray modes will be studied in detail.

Morphology and Properties of Microcellular foams by High Infernal Phase Emulsion Polymerization: Effect of Emulsion Compositions (HIPE 중합에 의한 미세기공 발포체의 모폴로지 및 물성: 유화계 조성의 영향)

  • 정한균;지수진;이성재
    • Polymer(Korea)
    • /
    • v.26 no.6
    • /
    • pp.759-766
    • /
    • 2002
  • Regular, spherical and isotropic open-microcellular foams having low density were prepared by the high internal phase emulsion (HIPE) polymerization mainly composed of styrene monomer and water The effects of Polymerization conditions. such as the content of water, divinylbenzene as a crosslinking agent and dodecane as a chain transfer agent, were investigated based on the tell size and foam properties. The microstructural morphology was observed using scanning electron microscopy (SEM) and the compression modulus of the foam was evaluated using compression test. The dropwise feeding of the aqueous phase into the oil phase was more effective than the batch feeding in producing the uniform and stable foam. Agitation speed and surfactant strongly influenced on the cell size and the window size between water droplets. Introduction of chain transfer agent increased the cell size, whereas it decreased the window size. Compression modulus increased with the crosslinking agent, but decreased with the chain transfer agent.

A STUDY OF THE EFFECT OF LOW INTENSITY INITIAL LIGHT CURING ON THE BOND STRENGTH OF RESIN RESTORATION (초기 저광도 광중합이 레진 수복물의 결합강도에 미치는 영향에 관한 연구)

  • Han, Mi-Ran;Kwon, Soon-Won;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.45-53
    • /
    • 2001
  • Recently some studies have shown that low light intensity followed by final cure at high light intensity may result in a smaller marginal gap and may be no negative effect on material properties. The purpose of this study was to evaluate the influence of the initial cure with low intensity on the shear bond strength of dentin and the microhardness of composite resin. Twenty intact bovine teeth were prepared for shear bond strength test and each tooth sectioned to three specimens. The specimens were randomly divided into three groups according to the light intensity and curing time as follows; Group I. $450mmW/cm^2$ 40sec Group II. $300mmW/cm^2$ 20sec and $600mmW/cm^2$ 20sec Gropu III. $250mmW/cm^2$ 20sec and $450mmW/cm^2$ 20sec. Samples of each group were restored with light-cured composite resin after dentin bonding and then the shear bond strength of each specimen were measured using universal testing machine. Ten resin specimens per group were prepared. After 24 hours, the Vickers microhardness value was measured at the top and bottom surfaces. The result are as follows; 1. Mean value of low initial intensity groups(II, III) were higher than the control group(I) in shear bond strength, but no significant difference could be found. 2. No significant difference could be found between three groups in microhardness.

  • PDF

THE CHANCE OF ADAPTABILITY CHANCE IN ADHESIVE SYSTEMS TO DENTIN SUBSTRTE ACCORDING TO STORAGE TIME (상아질 접착 후 저장기간에 따른 접착제의 접착력 변화)

  • Cho, Young-Gon;Ban, Il-Hwan;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.204-214
    • /
    • 2005
  • This study compared the microtensile bond strength (${\mu}$TBS) and microscopic change of two 2-step and two 1-step self-etching adhesives to dentin according to storage times in distilled water. Occlusal dentin was exposed in 48 human molars. They were divided to four groups by different adhesives: SE Bond group (Clearfil SE Bond), AdheSE group (AdheSE). Adper group (Adper Prompt L-Pop), and Xeno group (Xeno III) . Each group was stored in 37$^{\circ}C$ distilled water for 1, 15, and 30 days. Resin-bonded specimens were sectioned into beams and subjected to ${\mu}$TBS testing with a crosshead speed of 1 mm/minute. For SEM observation, one specimen was selected and sectioned in each group after each stroage time. Resin-dentin interface was observed under FE-SEM. In all storage times, mean ${\mu}$TBS of SE group was significantly higher than those of other groups (p < 0.05). There was no significant difference between mean ${\mu}$TBS of SE group and AdheSE group among all storage times, but significant difference between 1- and 30-day storage in mean y${\mu}$TBS of Adper group and Xeno group (p > 0.05). For 1-and 15-day storage, all groups showed the close adaptation between resin-dentin interfaces. For 30-day storage, resin-dentin interfaces showed wide gap in Adper group and separate pattern in Xeno III group.

Studies on the Physical Properties of Synthetic Rubber Blends Containing Rein-forcing Fillers (보강성 충전제를 함유한 합성고무 블렌드의 물리적 특성에 관한 연구)

  • Go, Jin-Hwan;Lee, Seog
    • Elastomers and Composites
    • /
    • v.33 no.4
    • /
    • pp.231-237
    • /
    • 1998
  • In order to investigate the physical properties of rubber blend compound, this experiment was carried out on the cure rate, loss tangent, reinforcement and abrasion properties of S-SBR (solution styrene-butadiene rubber) blends containing silane coupled silica and E-SBR (emulsion styrene-butadiene rubber) blends containing carbon black as a model compound. E-SBR blend showed the highest total bound rubber(TBR), while S-SBR blends showed constant TBR level regardless of rubber type. Rapid cure rate was achieved when the styrene and vinyl content of rubber microstructure decreased and TBR content of rubber compounds increased. The modulus as the index of rubber reinforcement showed the linear relation with TBR content. The large amount of PICO loss was observed when the styrene and vinyl content of rubber microstructure increased, while the small amount of PICO loss was observed when the ratio of bu-tadiene increased in the S-SBR blends with silane copuled silica. The high loss tangent at $0^{\circ}C$, the low loss tangent at $60^{\circ}C$, and the large difference of loss tangent were shown in the S-SBR blends with high styrene content compared to E-SBR blend.

  • PDF