• Title/Summary/Keyword: 물 주입

Search Result 981, Processing Time 0.023 seconds

Relationship Between Mass Transfer and Degradation of Sorbed Phenanthrene in Goethite Catalyzed Fenton-like Oxidation Using Non-ionic/anionic Surfactant (Phenanthrene 의 goethite 촉매에 의한 Fenton 산화에 있어서 음이온/비이온 계면활성제의 영향)

  • Kim, Jeong-Hwan;Choi, Won-Ho;Kim, Jung-Hwan;Park, Joo-Yang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2B
    • /
    • pp.207-212
    • /
    • 2009
  • Surfactants were used as representative anionic and non ionic surfactants to investigate the effect of mass transfer on the mineral-catalyzed Fenton-like oxidation of sorbed phenanthrene. Mass transfer of phenanthrene on the oxide surface or interlayer between aqueous and solid phases was generated by surfactant addition. Apparent solubility of phenanthrene was increased as surfactant concentration increasesd. In tests using Tween 80, oxidation of phenanthrene decreased as apparent solubility increased. High apparent solubility was not responsible for oxidation of sorbed phenanthrene in the sand due to the surfactant acted as a scavenger of degradation. In tests with SDS, $H_{2}O_{2}$ decomposition rate in Fenton-like oxidation was decreased by complexation between goethite and SDS. However, in tests using 32 mM of SDS, efficiency of phenanthrene treatment increased compared to the test without SDS addition. Therefore, suitable amount of SDS addition could provide optimum condition for phenanthrene oxidation on the oxide surface or interlayer between aqueous and solid phase, and decrease $H_{2}O_{2}$ decomposition, and as a result, phenanthrene removal efficiency can be improved.

Remediation of Sediments using Micro-bubble (미세기포를 이용한 퇴적물 정화)

  • Kang, Sang Yul;Kim, Hyoung Jun;Kim, Tschung Il;Park, Hyun Ju;Na, Choon Ki;Han, Moo Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.420-427
    • /
    • 2016
  • This study was conducted on the sediment remediation using micro-bubble to remove fine particles. For this study, characteristics of contamination and release in sediment were analyzed. And then, the characteristics of bubbles on removal efficiency was investigated at various operation conditions. In particle size distribution of the sediment used for the study, the proportion of clay and silt (<0.075 mm) was about 7.7%, sand (0.075~4.75 mm) was about 67.8%, and gravel (${\geq}4.75$) was 24.5%. Total nitrogen (TN) and total phosphorus (TP) of the sediment were 2,790~3,260, 261~311 mg/kg respectively. Ignition loss and water content were 4.1~9.6, 32.9~53.2% respectively. In analysis of removal efficiency according to operation conditions of micro-bubble, it was the highest when operation condition is pressure 6 atm, pressurized water ratio 30%, and coagulant dosage 15 ppm. At the time, the sediment's removal efficiency was 19.9%. Accordingly removal efficiency of TN and TP were 21.4, 22.6% respectively. Finally a research was found that fine particles in sediment were almost removed by micro-bubble, which led to decrease nutrients' release at about 20.1~64.3% in comparison to sediment including lots of fine particles.

p형 불순물이 첨가된 정공 수송층을 사용한 녹색 유기발광소자의 전하전송 메카니즘

  • Lee, Gwang-Seop;Chu, Dong-Cheol;Kim, Tae-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.424-424
    • /
    • 2010
  • 유기발광소자는 전류구동소자로서 소자를 대형화할 때 소모 전력이 급격히 증가하여 다른 디스플레이 제품에 비해 더욱 더 높은 전력효율을 요구한다. 높은 전력효율과 낮은 구동전압을 갖는 유기발광소자를 제작하기 위해서 P-I-N구조의 유기발광소자에 관한 연구가 활발히 진행되고 있다. 본 연구에서는 일함수가 큰 투명 Indium Tin Oxide (ITO) 양극 위에 p 형 불순물인 2,3,5,6-tetrafluoro-7,7,8,8-tetracyano-quinodimethane (F4-TCNQ) 를 4,4',4"-tris(N-(2naphthyl)-N-phenylamino)triphenylamine (2-TNATA)에 도핑하여 정공주입 및 정공수송을 향상하였으며, 그위에 N,N'-bis(1-naphthyl)-N,N'-diphenyl- 1,1'-biphenyl-4,4'-diamine (NPB) 층을 증착 후, tris-(8-hydroxyquinoline) aluminum ($Alq_3$) 발광층과 전자 수송층으로 사용하여 전자와 정공이 재결합을 하여 엑시톤을 형성하여 녹색 빛을 측정하였다. p 형 불순물은 정공 수송층의 에너지 장벽을 감소하며 발광층으로의 정공주입량을 증가하는 역할을 하여 구동전압을 감소하였으나 발광층내에서 전자와 정공의 비를 불균일하게 하여 발광효율은 약간 감소하였다. p형 불순물인 F4-TCNQ의 도핑의 농도에 따라 측정된 발광특성의 변화로부터 정공의 전송 메카니즘을 분석하였으며 이는 p형 불순물 첨가된 녹색 유기발광소자의 전하수송 메카니즘을 이해하는데 중요한 자료를 제공할 것이다.

  • PDF

Analysis of grout injection distance in single rock joint (단일절리 암반에서 그라우팅 주입거리 분석)

  • Ji-Yeong Kim;Jo-Hyun Weon;Jong-Won Lee;Tae-Min Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.541-554
    • /
    • 2023
  • The utilization of underground spaces in relation to tunnels and energy/waste storage is on the rise. To ensure the stability of underground spaces, it is crucial to reinforce rock fractures and discontinuities. Discontinuities, such as joints, can weaken the strength of the rock and lead to groundwater inflow into underground spaces. In order to enhance the strength and stability of the area around these discontinuities, rock grouting techniques are employed. However, during rock grouting, it is impossible to visually confirm whether the grouting material is being smoothly injected as intended. Without proper injection, the expected increases in strength, durability, and degree of consolidation may not be achieved. Therefore, it is necessary to predict in advance whether the grouting material is being injected as designed. In this study, we aimed to assess the injection performance based on injection variables such as the water/cement mixture ratio, injection pressure, and injection flow using UDEC (Universal Distinct Element Code) numerical program. Additionally, numerical results were validated by the lab experiment. The results of this study are expected to help optimize variables such as injection material properties, injection time, and pump pressure in the grouting design in the field.

Removal of Dissolved Iron in Groundwater by Injection-and-Pumping Technique: Application of Reactive Transport Modeling (주입-양수 기법을 활용한 지하수 내 용존 철 제거: 반응성용질이동모델링의 적용)

  • Choi, Byoung-Young;Yun, Seong-Taek;Kim, Kyoung-Ho;Koh, Yong-Kwon;Kim, Kang-Joo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.29-37
    • /
    • 2007
  • Shallow alluvial groundwaters in Korea of tell exceed the Korean Drinking Water Standard for dissolved iron (0.3 mg/L), which is one of the important water quality problems, especially in the use of bank infiltration technique. Using the reactive transport modeling, in this study we simulated the effectiveness of injection-and-pumping technique to remove dissolved iron in groundwater. The results of simulation showed that pumping of groundwater after injection of oxygenated water into aquifers is very effective to acquire the permissible water quality level. Groundwater withdrawal up to several times of irjected water in volume can be applicable to yield drinkable water. Potential problems such as clogging and permeability lowering due to in-situ precipitation of iron hydroxides may be insignificant. We also discuss on the mechanism and spatial extent of iron removal in aquifer.

Coolant Leak Effect on Polymer Electrolyte Membrane Fuel Cell (고분자전해질연료전지의 냉각수 누설에 대한 연구)

  • Song, Hyun-Do;Kang, Jung-Tak;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of polymer electrolyte membrane fuel cell could be decreased due to coolant leaked from connection part. Micro pump was used to put small amount of coolant and investigate the effect on fuel cell. The stoichiometric ratio of hydrogen/air was 1.5/2.0, both side of gas was fully humidified, and current density of $400mA/cm^2$ was used as standard condition in this experiment. Constant current method was used to check performance recovery from coolant effect in 3 cell stack. The performance was recovered when coolant was injected in cathode side. On the other hand, the performance was not recovered when coolant was injected in anode side. Ethylene glycol could be converted to CO in oxidation process and cause poisoning effect on platinum catalyst or be adhered on GDL and cause gas diffusion block effect resulting performance decrease. Water with nitrogen gas was supplied in anode side to check performance recovery. Polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy was used to check performance, and gas chromatography was used to check coolant concentration. Constant current method was not enough in full recovery of performance. However, water injection method was proved good method in full recovery of performance.