• Title/Summary/Keyword: 물이용취약지수

Search Result 38, Processing Time 0.023 seconds

Development of Operating Rule Curve for Multipurpose Water Supply in Heightened Agricultural Reservoir (농업용 둑높임저수지의 다중 용수공급을 위한 이수운영기준곡선 개발)

  • Park, Jong-Yoon;Jung, In-Kyun;Lee, Kwang-Ya;Kim, Seong-Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1389-1400
    • /
    • 2013
  • This study developed an operating rule curve (ORC) for multipurpose water supply (irrigation and environmental water) in heightened agricultural reservoir. Among the 20 reservoirs in improvement project of agricultural reservoir dam heightening, the 4 representative reservoirs (Ungyang, Gungchon, Yongam and Unam) were selected for the study according to the analysis of statistical characteristics. Available environmental water supply amounts during irrigation and non-irrigation periods, which is the range from release restricted water level to high water level were estimated by water balance analysis using reservoir operation model. Reliability, resiliency and vulnerability criteria for water system performance were used to assess the multiple water supply capacity. The ORC was presented as the percentile rank for the daily reservoir water level from the results of reservoir operation using the past couple of decades weather data. The water levels for each percentile were divided into 3 buffer sections representing drought (5~25%), normal (25~75%), and flood (75~95%) year to operate the heightened agricultural reservoir with ORC.

Failure Strength of the Composite Mechanical Joint according to the Stacking Angle (적층각 변화에 따른 복합재료 기계적 체결부의 파손강도)

  • Jo, Dae-Hyeon;Kim, Cheol-Hwan;Choi, Jin-Ho
    • Composites Research
    • /
    • v.30 no.4
    • /
    • pp.229-234
    • /
    • 2017
  • Generally, joints are the weakest part in the composite structures. Composite joints can be classified into adhesive joints and mechanical joints, and mechanical joints are mainly used in areas less sensitive to environmental conditions. In this paper, the failure loads of composite mechanical joints with five different stacking angles are tested and predicted. Finite element analysis of mechanical joints were performed and failure loads were predicted by the FAI(Failure Area Index) method using Tsai-Wu and Yamada-Sun failure criteria, and the predicted failure loads were compared with experimental results. From the experiment and analysis, the failure loads of the mechanical joints were decreased as the ratio of 0 degree layer was low and they could be predicted within 13.03% using the FAI method and Yamada-Sun failure criteria.

Hydrological Drought Analysis and Monitoring Using Multiple Drought Indices: The Case of Mulrocheon Watershed (수문학적 가뭄감시 및 해석을 위한 다양한 가뭄지수 평가 -물로천 유역을 중심으로-)

  • Lee, Joo-Heon;Park, Seo-Yeon;Kim, Min Gyu;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.477-484
    • /
    • 2021
  • Due to climate change, parts of Korea are experiencing large and small droughts every 2-3 years and extreme droughts every 7 years. Since most droughts occur mainly in areas where small water supply facilities in the tributaries or upstream are located, more research on technology for securing water in these areas is required. In this study, a drought evaluation using SPEI (Standardized Precipitation Evapotranspiration Index), SDI (Streamflow Drought Index), and WBDI (Water Budget-based Drought Index) was performed to investigate hydrological drought in the Mulrocheon watershed of Chuncheon, a vulnerable area in terms of water supply. As a result of calculating hydrological drought indices SPEI and SDI, examining each duration, it was confirmed that the common drought in 2014 did not recover and continued until 2015. In the hydrological drought index evaluation result by WBDI, a very severe drought condition was observed in the spring of 2015 following 2014, and that drought was the most severe at -1.94 in November 2017. As a result of deriving a SDF (Severity-Duration-Frequency) curve through frequency analysis by duration using the drought index calculated on a monthly basis from 2003 to 2019 (17 years), most droughts in the Mulrocheon watershed were found to have a return period of less than 10 years, but droughts that occurred in 2014, 2015, and 2019 were found to cover more than 20 years, respectively.

Analysis on the Influence of Groundwater Level Changes on Slope Stability using a Seismic Refraction Survey in a Landslide Area (지구물리탐사를 이용한 산사태지역의 지하수위에 따른 안정성 해석)

  • Lee, Kyoung-Mi;Kim, Hyun;Lee, Jae-Hyuk;Seo, Young-Seok;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.545-554
    • /
    • 2007
  • Landslides is mainly induced by a heavy rainfall, earthquake ground motion, and some other factors like soil mechanics, morphological-geological factors etc. Since the starting point of the failure seemed to be originated at a construction site in the study, it is meaningful to find out the relationship between the landslide and the construction. For this study, the slope failure factor was examined carefully to see that the original natural slope had vulnerability and that the complex ground had unstability changed by construction. A field survey was conducted on the original ground surface and filled-up ground. A laboratory test was also conducted to determine the geomechanical properties of soil samples. 2D and 3D limit equilibrium analysis with changing groundwater level were conducted at the failure depth using a seismic refraction survey. The result shows that the factor of safety is similar stability under all condition, but unstable under saturated condition.

Decision Making of Seismic Performance Management for the Aged Road Facilities Based on Road-Network and Fragility Curve (취약도곡선을 이용한 도로망기반 노후도로시설물 내진성능관리 의사결정)

  • Kim, Dong-Joo;Choi, Ji-Hae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.94-101
    • /
    • 2021
  • According to the Facility Management System (FMS) operated by the Korea Authority of Land & Infrastructure Safety, it is expected that the number of aging facilities that have been in use for more than 30 years will increase rapidly to 13.9% in 2019 and 34.5% in 2929, and end up with a social problem. In addition, with the revision of "Common Application of Seismic Design Criteria" by the Ministry of Public Administration and Security in 2017, it is mandatory to re-evaluate all existing road facilities and if necessary seismic reinforcement should be done to minimize the magnitude of earthquake damage and perform normal road functions. The seismic performance management-decision support technology currently used in seismic performance management practice in Korea only determines the earthquake-resistance reinforcement priority based on the qualitative index value for the seismic performance of individual facilities. However with this practice, normal traffic functions cannot be guaranteed. A new seismic performance management decision support technology that can provide various judgment data required for decision making is needed to overcome these shortcomings and better perform seismic performance management from a road network perspective.

Reconsideration and Conservational Scientific Diagnosis of Silla Stone Monument in Bongpyeong-ri, Uljin (울진 봉평리 신라비의 재판독과 보존과학적 진단)

  • Jo, Young-hoon;Lee, Chan-hee;Shim, Hyun-yong
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.3
    • /
    • pp.48-67
    • /
    • 2013
  • This study was focused on the recognition of historical values and the establishment of conservation schemes for a Silla stone monument in Bongpyeong-ri, Uljin by combining the humanistic investigation of inscription reinterpretation and the scientific conservational diagnosis of deterioration. According to the investigation of inscription, a total of 13 letters were reconsidered compared to the preceding researches. Thus, the meaning and interpretation of previous inscription was partially changed. This monument is composed of gneissose leucogranite and the most suitable site as provenance of the stone would be the Jukbyeon seashore (2.1km). The site shows similar color, size and composition of minerals, gneissose structure and magnetic susceptibility as the Bongpyeong stone monument. This monument developed a structural crack (crack index 0.4) and a microcrack (crack index 2.0) along the gneissose structure. The horizontal strength is weaker than the vertical strength. Therefore, the cracks should be reinforced and treated. However, consolidating is not urgently needed because the total weathering grade by ultrasonic velocity shows the stage of moderate weathering(3,403m/s, 0.32). Also, the major problems of chemical deterioration are blackening (85.2%) with soil, iron oxide,rubbing mark, and salt crystals (17.3%) from the sea. Therefore, the contaminants and the salt crystals should be removed using pressure spray and pulp paper, while the application of poultice should be examined through clinical tests.

The Influence of Extrusion Ratio on Microstructure and Thermoelectric Properties of Rapidly Solidified N-type $Bi_2Te_{2.75}Se_{0.15}$ (급속응고된 N-type $Bi_2Te_{2.75}Se_{0.15}$ 열전재료의 미세조직과 열전특성에 미치는 압출비의 영향)

  • 이상일;홍순직;손현택;천병선;이윤석
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2001.11a
    • /
    • pp.30-30
    • /
    • 2001
  • $Bi_2Te_3$계 열전재료는 200~400K 정도의 저온에서 네어지 변환효율이 가장 높은 재료로써 열전냉각, 바런재로 등에 응요하기 위하여ㅠ 제조법 및 특서에 관한 많은 연구가 진행되어 왔다. $Bi_2Te_3$계 화합물은 rhombohedral의 결정 구조를 가지는 층상 화 ;물로 결정대칭성으로 인해 연전기적으로 큰 이방성을 나타낸다. 현재는 일반향용고법에 의해서 입자를 a축 방향으로 성장시켜 큰 결정립을 가진 다결정재료를 사용하고 있으나, c면이 매우 취약하기 때문에 가공서이 나쁘다. 따라서 이와같은 단점을 개선하기 위하여 기계적 강도를 높일 수 있는 가공공정 및 합금설계에 대한 연구가 활발히 진행되고 있다. 측히 열간 압출법으로 제조된 열전재료는 결정립의 미세화와 높은 이방성으로 성능지수와 기계적 강도를 향상시킬 수 있다는 연구결과가 보고되고 있다 또한 Schultz드의 연구결과에 의하면 $Bi_2Te_3$ 계 열전재료는 소성변형에 의하여 발생한 점결함에 의하여 캐리어 농도가 변화되며 이로 인하여 재료의 전기적 성질이 결정된다고 하였다. 따라서 상당히 큰 소성가공량과 열전측성과의 관계를 규명하는 것은 매우 중요하다. 이에 본 연구에서는 압출변수 중 소성가공량에 중요한 변수로 작요아는 압출비를 변화시켜 최적의 열간 소성가공량을 검토하고, 이에 따른 열전측성과 압출비와의 상관관계에 대하여 연구하는 것을 목적으로 하였다. 연구에 사용된 N형의 조성은$Bi_2Te_{2.75}Se_{0.15}$로서 순도 99.99를 사용하였고, dopant로 0.1wt%의 $SbI_3$를 사용하였다. $Bi_2Te_{2.75}Se_{0.15}$ 분말은 가스분사법(Gas atomization Process)를 이용하여, 용탕제조시 아르곤가스로 산화를 방지하였고, 냉매로는 질소가스를 이용하였다. 제조된 분말을 기ㅖ적 분급법을 이용하여 분급하였고, 냉매로는 질소가스를 이용하였다. 제조된 분말을 기계적 분급ㅂ법을 이용하여 분급하였고, 압출에 이용된 분말은 250$\mu\textrm{m}$이하의 크기를 사용하였다. 또한 분말제조과정 중 형성되는 표면산화층을 제거하기 위하여 36$0^{\circ}C$에서 4시간동안 수소 환원처리를 행하였다. 제조된 분말은 열간 압출을 위하여 Aㅣcan에 넣고 냉간성형체를 만들고, 진공처리를 한 후 밀봉하여 탈가스처리를 하였다. 압출다이는 압출비가 각각 28:1과 16:1인 평다이(9$0^{\circ}C$)를 사용하여 각각 내경이 9, 12cm이고, 길이가 50, 30cm인 압출재를 제조하였다. 열간압출한 후의 미세조직을 광학현미경으로 압출방향에 평행한 방향과 수직방향으로 관찰하였고, 열간 압출재 이방성을 검토하기 위하여 X선 회절분석을 실실하여 결정방위를 확인하였다. 전기 비저항 및 Seebeck 계수 측정을 위하여 각각 2$\times$2$\times$10$mm^3$ 그리고 5$\times$5$\times$10$mm^3$ 크기의 시편을 준비하였다.준비하였다.

  • PDF

Evaluation of Chloride Diffusion Behavior and Analysis of Probabilistic Service Life in Long Term Aged GGBFS Concrete (장기 재령 GGBFS 콘크리트의 염화물 확산 거동 평가 및 확률론적 염해 내구수명 해석)

  • Yoon, Yong-Sik;Kim, Tae-Hoon;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.47-56
    • /
    • 2020
  • In this study, three levels of W/B(Water to Binder) ratio (0.37, 0.42, 0.47) and substitution ratio of GGBFS (Ground Granulated Blast Furnace Slag) rate (0 %, 30 %, 50 %) were considered to perform RCPT (Rapid Chloride Diffusion Test) at the 1,095 aged day. Accelerated chloride diffusion coefficient and passed charge of each concrete mixture were assessed according to Tang's method and ASTM C 1202, and improving behaviors of durability performance with increasing aged days are analyzed based on the test results of previous aged days from the preceding study. As the age of concrete increases, the passed charge and diffusion coefficient have been significantly reduced, and especially the concrete specimens containing GGBFS showed a significantly more reduction than OPC(Ordinary Portland Cement) concrete specimen by latent hydraulic activity. In the case of OPC concrete's results of passed charge, at the 1,095 days, two of them were still in the "Moderate" class. So, if only OPC is used as the binder of concrete, the resistance performance for chloride attack is weak. In this study, the time-parameters (m) were derived based on the results of the accelerated chloride diffusion coefficient, and the deterministic and probabilistic analysis for service life were performed by assuming the design variable as a probability function. For probabilistic service life analysis, durability failure probabilities were calculated using Monte Carlo Simulation (MCS) to evaluate service life. The service life of probabilistic method were lower than that of deterministic method, since the target value of PDF (Probability of Durability Failure) was set very low at 10 %. If the target value of PDF suitable for the purpose of using structure can be set and proper variability can be considered for each design variable, it is believed that more economical durability design can be made.