• Title/Summary/Keyword: 무효전력변동

Search Result 62, Processing Time 0.03 seconds

Power Quality Improvement using DVR (DVR을 이용한 전력품질 개선)

  • Kim, Seong-Hwan
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.462-466
    • /
    • 2021
  • DVR is a device that compensates for voltage fluctuations in distribution lines and is generally used in combination with a device that compensates reactive power and improve power factor. Such a coupling compensator has the disadvantage of being relatively difficult to control and bulky. In this paper, mathematical analysis of the maximum magnitude of the compensation voltage, phase angle, compensable reactive power and active power was performed in order to simultaneously compensate the reactive power and voltage fluctuation of the distribution line by applying the power angle control method of the DVR. A control algorithm for charging active power to the battery and supplying stored energy when the voltage is changed was developed and the results were confirmed through Matlab simulation.

Analysis of the Effect on Power System with WTGs (풍력발전기 출력에 따른 계통영향 분석)

  • Kim, Hyeong-Taek;Kim, Se-Ho;Myung, Ho-San;Kim, Yeong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.330-331
    • /
    • 2011
  • 제주도의 풍부한 바람자원과 육지에 비해 높은 SMP로 많은 풍력사업자들이 제주지역에 풍력단지를 조성하기 위해 노력을 기울이고 있다. 향후 대규모 풍력단지가 조성된다면 풍속변화에 따라 생산되는 전력의 변동은 커질 것이다. 이러한 풍력발전기의 가변성으로 인한 출력변동은 계통의 주파수와 국지적인 모선 전압의 변동을 유발할 수 있다. 따라서 전력계통 신뢰도와 안정성을 위하여, 계통 운영 상황을 고려한 풍력발전기 운영이 요구된다. 본 논문에서는 PSS/E를 통해 가상 계통을 구현하여 풍력발전기의 무효전력 공급 유 무에 따라 계통에 미치는 영향을 선로의 무효전력과 모선 전압 측면에서 분석하였다.

  • PDF

Active and Reactive Power Control Method for Grid-Connected Three-Phase PWM Inverter (계통 연계형 3상 PWM 인버터의 유·무효전력제어 방법)

  • Ahn, Hyun-Jin;Jung, Young-Gook;Lim, Young-Cheol;Oh, Seung-Yeol;Kim, Kwang-Heon
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.263-264
    • /
    • 2010
  • 본 연구에서는 3상 계통 연계형 인버터의 유 무효전력제어를 통해 부하에 필요한 전력을 공급하며 계통과 인버터를 안정적으로 연계하는 방법을 다루고 있다. 부하 변동 및 계통전압과 인버터 전압의 위상차 ${\theta}$에 따라 PSIM 시뮬레이션을 수행하였으며, 타당성을 입증하였다

  • PDF

Adaptive Compensation Technique of Parameter Variation for Quick Torque Response of an Induction Motor Drive (유도전동기의 속응 토크제어를 위한 파라미터 변동의 적응보상기법)

  • 손진근;정을기;김준환;전희종
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.206-213
    • /
    • 1998
  • In this paper, an adaptive compensation technique for parameter variation is proposed which can perform quick torque response in vector control of an induction motors. To solve the problem of control performance degradation due to parameter variation in an induction motor, a rotor resistance estimation is performed by the model reference adaptive control(MRAC). The algorithm of rotor resistance estimation is composed of the error relationship which is generated between a motor real instantaneous reactive power and an estimated instantaneous reactive power. The advantage of such a real reactive power reference model is independence of the motor parameter variation. The estimation rotor resistance values are applied to the direct vector control system with a flux observer. Finally, the simulations and experiment are presented to validate the rotor resistance estimation algorithm of induction motor.

  • PDF

Grid Fault Ride-Through Control of Modular Multilevel Converter for Medium Voltage DC Distribution (특고압 직류 배전망을 위한 모듈형 멀티레벨 컨버터의 계통 사고 ride-through 기술)

  • Jo, Seung-Rae;Kim, Seok-Min;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.27-29
    • /
    • 2018
  • 본 논문은 모듈형 멀티레벨 컨버터 기반 특고압 직류 배전망의 수전 계통 사고 대응 기법을 제안한다. 수전 계통의 순간적인 저전압 및 단락 사고 발생 시 전력변환장치는 계통 전압의 정상화를 지원하기 위해 연계를 유지해야 하며 계통 측의 요구에 따라 전압 변동률에 따른 무효 전력을 공급해야 한다. 제안하는 기법은 계통 사고 발생 시 계통 코드에 따라 무효 전류를 공급하여 수전 계통의 전압 레벨 복구를 지원한다. 시뮬레이션을 통해 제안하는 계통 사고 대응 기법의 타당성을 확인한다.

  • PDF

Performance Improvement of an Anti-Islanding Algorithm using the Variation of Reactive Power with an Improved DFT Method (개선된 DFT을 이용한 무효전력변동 단독운전 검출기법의 성능 개선)

  • Kang, Duk-Hong;Choi, Dae-Keun;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.179-187
    • /
    • 2010
  • This paper proposes a new anti-islanding method for single-phase grid-connected photovoltaic (PV) systems using Goertzel algorithm. The proposed scheme is based on inducing increases or decreases of frequencies of load voltage and current that is in the form of existences or periodical variations of the reactive power components. The frequency detection is needed to apply this power variation method to the grid-connected power converter. The proposed method is able to get a fast detection for anti-islanding without the effect of harmonics and noises. The simulation and experiment results validate the effectiveness of the proposed method.

Algorithm for Anti-Islanding of the Grid Connected Single Phase PV Inverter (계통연계형 태양광 단상 인버터의 단독운전 방지를 위한 알고리즘)

  • Hwang, Uiseon;Seo, Jinbum;Kwon, Hyosang;Kim, Deokki;cho, Youngkyun;Min, Joonki
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.363-364
    • /
    • 2014
  • 본 논문에서 제안한 단독운전 알고리즘은 무효전력 주입을 기반으로 설계하였다. 정상상태에서는 무효전력을 주입하지 않고 계통전압, 고조파, 주파수의 변동을 확인하여 제 1차와 2차 단계를 통해 무효전력의 주입량과 주입 방향을 결정하여 주입한다. 제안한 방법을 통하여 단독으로 운전될 때 뿐만 아니라 다수대 병렬운전할때도 단독운전을 200ms 이내에 검출됨을 확인하였다.

  • PDF

Compensation of Voltage Variation Using Active Power-Dependent Reactive Power Control with Multiple VRE Systems Connected in a Distribution Line (배전 선로에 연계된 다수대의 변동성 재생에너지 발전 시스템의 출력 유효전력 변동에 따른 무효전력 제어를 이용한 전압 변동 보상)

  • Lee, Sang-Hoon;Kim, Soo-Bin;Song, Seung-Ho
    • Journal of Wind Energy
    • /
    • v.9 no.4
    • /
    • pp.47-56
    • /
    • 2018
  • This paper introduces an active power dependent standard characteristic curve, Q(P) to compensate for voltage variations due to the output of distributed generation. This paper presents an efficient control method of grid-connected inverters by comparing and analyzing voltage variation magnitude and line loss according to the compensation method. Voltage variations are caused not only by active power, but also by the change of reactive power flowing in the line. In particular, the system is in a relatively remote place in a coastal area compared with existing power plants, so it is relatively weak and may not be suitable for voltage control. So, since it is very important to keep the voltage below the normal voltage limit within the specified inverter capacity and to minimize line loss due to the reactive power. we describe the active power dependent standard characteristic curve, Q(P) method and verify the magnitude of voltage variation by simulation. Finally, the characteristics of each control method and line loss are compared and analyzed.

A Study of Insulation Breakdown Cause Analysis and Measure of 362kV 50kA Circuit Breaker for Shunt Reactor Switching (362kV 50kA 다빈도 차단기 고장원인 분석 및 대책에 관한 연구)

  • Choi, Young-Sung;Jeon, Sang-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.408-409
    • /
    • 2015
  • 한국전력공사에서는 2015년 4월말 기준 808개의 변전소를 운전 중에 있다. 변압기 용량으로 보면 299,734MVA에 달하고 있으며, 매년 증가하는 전력수요에 맞추어 신규 변전소 건설과 더불어 변전설비가 계속하여 확충되고 있다. 또한, 계절별 및 시간대별 부하변동에 따른 변전소 모선의 전압변동에 대응하기 위하여 Sh.C(Shunt Condenser), Sh.R(Shunt Reactor), SVC(Static Var Compensator) 등 다양한 무효전력보상 및 조절 설비들이 지속적으로 설치되고 있다. 이들 무효전력보상 설비들은 주로 변전소 모선에 전용 차단기를 통하여 연결되어 운전되고 있으며, 전용 차단기는 매일 시간대별 부하변동에 대응하여 개폐빈도가 많은 다빈도 차단기로서 잦은 개폐조작에 따른 내구성이 필요하며 변전소 모선전압을 기준전압 범위 이내로 안정적으로 유지하기 위한 신뢰성이 요구되고 있다. 본 논문에서는 345kV Sh.R 개폐용 동일유형의 345kV 50kA 1점절 다빈도 차단기에서 차단조작시 발생한 차단부 절연파괴 고장의 원인을 분석하고 재발방지를 위한 대책에 대하여 논하였다.

  • PDF

Voltage & power of condenser by series connection of condenser-reactor under the voltage unbalance (회전속도 변화에 따른 유도기 무효전력 계산)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung;Kim, Sung-Hun;Kim, Young-Guk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.874-875
    • /
    • 2011
  • 3상 유도기는 동기속도 이하에서 운전할 경우 전동기로 동작하지만, 동기속도 이상의 운전할 경우 발전기 동작이 가능하여 소수력과 같이 소용량의 설비에 종종 적용하고 있다. 전동기로 사용할 경우 대부분 부하가 일정하기 때문에 문제가 되지 않지만, 발전기로 사용할 경우 부하 변동에 따라 회전수가 달라져 발생전압의 변화가 높은 편이고, 회전자계를 발생하기 위해 필요한 무효전력도 전동기와 발전기로 사용할 경우 공급 포인트가 달라진다. 본 연구에서는 유도기를 전동기로 사용하는 경우와 발전기로 사용하는 경우 회전속도 변화에 따라 회전자계를 발생시키는 필요한 자화전류와 무효전력을 일반적으로 규정하고 있는 범위에 들어가는지를 계산을 통해 확인하였다.

  • PDF