• 제목/요약/키워드: 무전극 램프

Search Result 130, Processing Time 0.026 seconds

Investigation of Hg free Electrodeless inductively capacitive tubular discharge (무수은 무전극 유도-용량형 직관형 램프 방전에 관한 연구)

  • 이태일;박해일;백홍구
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.191-196
    • /
    • 2002
  • In this paper we introduce novel electrode structure for high efficiency discharge. We operate discharge tube under the 0.16 torr pure Xe and apply the sinusoidal wave power to the lamp with 60kHz. We measure the electric power dissipation, plasma parameters, and 828 nm IR intensity. From these data we determine the discharge efficiency, IR intensity/watt, EEDF(Electron energy distribution function). As a result we obtain that the novel electrode structure has better performance in efficiency than that of conventional external electrode system. Also we determine the EEDF for each type of electrode structure by Boltzmann stover, EELNDIF code. The result of Boltzmann equation solving show that the noble electrode system has many high energy electrons compared with the conventional system.

  • PDF

Impedance and Q-factor of frequence dependance accoding to ferrites on electrodeless fluorescent lamp (무전극 형광램프의 페라이트 종류에 따른 임피던스 및 Q-Factor의 주파수 의존성)

  • Kim, Hoe-Geun;You, Dae-Won;Park, Sung-Mook;Pack, Gwang-Hyeon;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.3-7
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relativie property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined resistance kind, impedance, Q-factor's frequency characteristic by ferrite. Impedance, resistance and capacitance did not show difference in start frequency 2.65 [MHz] but there was difference quantity. We could know Q-factor's difference according to material, and Q-factor's is important part of antenna design.

  • PDF

A Study on Electrodeless HID Lamp Systems Using Circularly Polarized Microwaves (원편파를 이용한 무전극 고압 방전 램프 시스템에 관한 연구)

  • Kim, Kyoung-Shin;Kim, Jin-Joong;Lee, Seung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.214-220
    • /
    • 2010
  • This paper presents the results of a study on an electrodeless high intensity discharge (HID) lamp system that is powered by circularly polarized microwaves (CPMs). The technique to generate CPMs enables an electrodeless high intensity discharge lamp to be turned on without the retation of the bulb but conventional electrodeless high intensity discharge lamps use rotating bulbs in order to prevent a puncture in a hot spots that are formed by the linearly polarized microwaves in the circular cavity. The technique to generate CPMs is described and the salient features of the lamp characteristics are presented.

Dependence of Round Type Electrodeless Lamp according to Ferrite Core and Cold Spot Temperature (둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Kim, Nam-Goon;Jung, Young-Il;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1078-1083
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature.

The Study of Measurement Method for an electrodeless lamp (무전극 램프의 광특성 측정방식에 대한 고찰)

  • Lee, Se-Hyun;Cho, Mee-Ryoung;Shin, Sang-Wuk;Hwang, Myung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.68-71
    • /
    • 2003
  • In this paper, We have investigated the luminous flux, luminous efficacy, spectral energy distribution, colour rendering index, correlated colour temperature of electrodeless QL lamp system as a center method of measurement and side method of measurement. A result of measurement is that center method of measurement and side method of measurement is almost similar. Therefore, Sample that didn't measured because of big size and heavy weight can be measured by center method of measurement.

  • PDF

Electromagnetic Properties of Ring -Shaped Electrodeless Fluorescent Lamps for Ferrite Core (페라이트를 이용한 환형 무전극 램프의 전자계 특성)

  • Jo, Ju-Ung;Lee, Seong-Jin;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.249-251
    • /
    • 2003
  • The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the line time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF

Modeling and Simulation of Endura Electrodeless lamp system (엔두라 무전극 램프용 안정기 개발을 위한 모델 및 시뮬레이션 연구)

  • Han Soo-Bin;Park Suck-In;Jung Hak-Kun;Kim Gue-Duck;Jung Bong-Man
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.902-905
    • /
    • 2004
  • Characteristics of electrodelss lamp as a load of the ballast is different compared to normal fluorescent lamp because the lamp includes the magnetics for inductive discharging process. So somewhat different modeling is necessary to make a proper power match between the lamp and ballast. Modeling of an electrodeless lamps, Endura of Osram, is presented in this paper. Simulation with a result of experiment is given for a verification of proposed model.

  • PDF

Electrical and Optical Characteristics by Ferrite for Electrodeless Fluorescent Lamp (무전극 형광램프용 페라이트에 따른 전기적 및 광학적 특성)

  • Pack Kwang-Hyeon;Yang Jong-Kyung;Lee Jong-Chan;Park Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.200-206
    • /
    • 2006
  • An electric power efficiency of electrodeless fluorescent lamp depens on a big relative property of gas, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. in lamp. We used magnetic substance that opens self-examination material of electrodeless fluorescent lamp antenna. We used Mn-Zn type as the Ferrite. We have examined resistance, impedance and Q-factor's frequency characteristic by ferrite. Coil turns were changed from 13 to 15 turns to recognize brightness change of lamp by winding number. Optical equipment (LS-100) was used to measure brightness. We could know Q-factor's difference according to material is important part of antenna design. When an electrodeless fluorescent lamp was made using T company's PE22, it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

Electromagnetic Radiation Properties of Electrodeless Fluorescent Lamps (무전극 형광램프의 전자계 방사 특성)

  • Lee, Jong-Chan;Park, Dae-Hee;Kim, Kwang-Soo;Ham, Hum;Park, Sung-Mok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.931-934
    • /
    • 2002
  • In recent year there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of Electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life of Electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 100,000 hours. In this paper, the Electromagnetic emitting properties were presented by simulation software operated at 2.65MHz and some specific conditions.

  • PDF

Brightness Property by Ferrite on Electroness Flurescent Lamp (무전극 형광램프용 페라이트에 따른 휘도특성)

  • Pack, Gwang-Hyeon;Lee, Jong-Chan;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.607-610
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relativie propertye of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. Coill turn was changed from 13th to 13th turn to recognize brightness change of lamp by winding number. Optical equipment that used in an experiment was used to measure brightness (LS-100). When an electrodeless fluorescent ]amp was made using and T company's PE22, was it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

  • PDF