• Title/Summary/Keyword: 무전극램프

Search Result 130, Processing Time 0.022 seconds

A Study on the Impedance Model of Electrodeless Fluorescent Lamp (무전극 형광램프의 임피던스 특성에 관한 연구)

  • Kim, Cherl-Jin;Yoo, Byeong-Kyu;Hong, Sung-Ho;Shin, Heung-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.264-266
    • /
    • 2006
  • This paper presents a impedance model for the simulation of both static and dynamic characteristics of the electrodeless fulorescent lamp. A behavioral, PSpice compatible, model has been developed for the electrodeless fluorescent lamp. The model was tested at steady-state for different power levels, with an LCC modulated drive. and this model is established from some equations and measured electrical characteristics of EEFL. The validity of proposed lamp model is verified from the simulation and experimental results.

  • PDF

A Dimmable High Frequency Resonant Inverter for Electrodeless Lamps (조광제어형 무전극 램프용 고주파 공전형인버터)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Oh, Won-Seok;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.487-489
    • /
    • 2004
  • As the electrodes are not needed, the electrodeless lamps using the induction discharge have a long lifetime and are robust against the variable output condition of a ballast. This paper proposed a dimmable resonant inverter for the electrodeless lamps. The proposed resonant inverter formed a half bridge inverter adopted FWM to control the average output power of the inverter and the illumination of a lamp. In this paper, the proposed dimming algorithm was described and the prototype experimental setup for 100W electrodeless lamps was carried out to verify the validity of the proposed dimming method.

  • PDF

2.5MHz Zero-Voltage-Switching Resonant Inverter for Electrodeless Fluorescent Lamp (무전극 램프 점등용 2.5MHz급 ZVS 인버터 개발에 관한 연구)

  • 박동현;김희준;조기연;계문호
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.261-265
    • /
    • 1997
  • Driving the electrodeless fluorescent lamp, the high ac voltage with high frequency is required. The linear power amplifier has been widely used as a driving circuit of electrodeless fluorescent lamp. However, the low efficiency of the power amplifier causes th driving circuit to be replaced by a PWM switching inverter. In order to use a PWM switching inverter as the driving circuit of an electrodeless fluorescent lamp, the high switching frequency is required. But due to the switching loss at switches of the inverter, the limitation of high switching frequency appears in the inverter. One solution to this limitation is to reduce the switching loss by using the zero voltage switching technique. In this paper, zero voltage switching resonant inverter for driving an electrodeless fluorescent lamp is discussed. The results of analysis about the inverter are presented and the equations for design are established. And the validity of the analyzed results are verified through the experiment.

  • PDF

Optical Properties of Inductively Coupled Plasma with Ar Gas Pressure and RF Power (13.56MHz) (Ar 가스압력과 RF 전력변화 (13.56MHz)에 따른 유도결합형 플라즈마의 광학적 특성)

  • Her, In-Sung;Kim, Kwang-Soo;Choi, Yong-Sung;Lee, Jong-Chan;Park, Dea-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.92-95
    • /
    • 2003
  • In this paper, the emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma. To transmit the electromagnetic energy into the chamber, a RF power of 13.56MHz was applied to the antenna and considering the Ar gas pressure and the RF electric power change, the emission spectrum, Ar-I line, luminance were investigated. At this time the input parameter for ICP RF plasma, Ar gas pressure and RF power were applied in the range of 10~60m Torr, 10~300W respectively.

  • PDF

Investigation of Hg free Electrodeless inductively capacitive tubular discharge (무수은 무전극 유도-용량형 직관형 램프 방전에 관한 연구)

  • 이태일;박해일;백홍구
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.191-196
    • /
    • 2002
  • In this paper we introduce novel electrode structure for high efficiency discharge. We operate discharge tube under the 0.16 torr pure Xe and apply the sinusoidal wave power to the lamp with 60kHz. We measure the electric power dissipation, plasma parameters, and 828 nm IR intensity. From these data we determine the discharge efficiency, IR intensity/watt, EEDF(Electron energy distribution function). As a result we obtain that the novel electrode structure has better performance in efficiency than that of conventional external electrode system. Also we determine the EEDF for each type of electrode structure by Boltzmann stover, EELNDIF code. The result of Boltzmann equation solving show that the noble electrode system has many high energy electrons compared with the conventional system.

  • PDF

Impedance and Q-factor of frequence dependance accoding to ferrites on electrodeless fluorescent lamp (무전극 형광램프의 페라이트 종류에 따른 임피던스 및 Q-Factor의 주파수 의존성)

  • Kim, Hoe-Geun;You, Dae-Won;Park, Sung-Mook;Pack, Gwang-Hyeon;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.3-7
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relativie property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined resistance kind, impedance, Q-factor's frequency characteristic by ferrite. Impedance, resistance and capacitance did not show difference in start frequency 2.65 [MHz] but there was difference quantity. We could know Q-factor's difference according to material, and Q-factor's is important part of antenna design.

  • PDF

A Study on Electrodeless HID Lamp Systems Using Circularly Polarized Microwaves (원편파를 이용한 무전극 고압 방전 램프 시스템에 관한 연구)

  • Kim, Kyoung-Shin;Kim, Jin-Joong;Lee, Seung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.214-220
    • /
    • 2010
  • This paper presents the results of a study on an electrodeless high intensity discharge (HID) lamp system that is powered by circularly polarized microwaves (CPMs). The technique to generate CPMs enables an electrodeless high intensity discharge lamp to be turned on without the retation of the bulb but conventional electrodeless high intensity discharge lamps use rotating bulbs in order to prevent a puncture in a hot spots that are formed by the linearly polarized microwaves in the circular cavity. The technique to generate CPMs is described and the salient features of the lamp characteristics are presented.

Dependence of Round Type Electrodeless Lamp according to Ferrite Core and Cold Spot Temperature (둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Kim, Nam-Goon;Jung, Young-Il;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1078-1083
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature.

The Study of Measurement Method for an electrodeless lamp (무전극 램프의 광특성 측정방식에 대한 고찰)

  • Lee, Se-Hyun;Cho, Mee-Ryoung;Shin, Sang-Wuk;Hwang, Myung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.68-71
    • /
    • 2003
  • In this paper, We have investigated the luminous flux, luminous efficacy, spectral energy distribution, colour rendering index, correlated colour temperature of electrodeless QL lamp system as a center method of measurement and side method of measurement. A result of measurement is that center method of measurement and side method of measurement is almost similar. Therefore, Sample that didn't measured because of big size and heavy weight can be measured by center method of measurement.

  • PDF

Electromagnetic Properties of Ring -Shaped Electrodeless Fluorescent Lamps for Ferrite Core (페라이트를 이용한 환형 무전극 램프의 전자계 특성)

  • Jo, Ju-Ung;Lee, Seong-Jin;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.249-251
    • /
    • 2003
  • The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the line time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF