• Title/Summary/Keyword: 무산소.호기조건

Search Result 30, Processing Time 0.23 seconds

무산소-호기공정을 이용한 순환식 생물여과반응기에서 동시 질산화 및 탈질화의 특성 연구

  • Lee, Su-Cheol;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.343-346
    • /
    • 2000
  • This study was carried out to investigate the effects of influent $NH_4^{\;+}-N$ load, C/N ratio and superficial air velocity on the nitrogen removal efficiencies. Laboratory scale upflow biological aerated filter(BAF) was consisted of an anoxic-aerobic filter packed with porous ceramic media and operated with synthetic wastewater. BAFs requires less energy and space for the system when compared to conventional activated sludge process. The influent C/N ratios were varied from 0 to 1 by adjusting acetate. Various superficial air velocity had been applied to investigate aeration effect on nitrogen removal. The BAF reactor showed more than 90% average $NH_4^{\;+}-N$ removal efficiencies at $NH_4^{\;+}-N$ loading in the range of $0.26{\sim}1.33$ kg $NH_4^{\;+}-N/m^3{\cdot}d$ and 62% average T-N removal efficiencies at the C/N ratio of 1. Moreover, average T-N removal efficiencies increased as the superficial air velocity increased, because of the increase $NH_4^{\;+}-N$ removal efficiencies.

  • PDF

Design and Environmental/Economic Performance Evaluation of Wastewater Treatment Plants Using Modeling Methodology (모델링 기법을 이용한 하수처리 공정 설계와 환경성 및 경제성 평가)

  • Kim, MinHan;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.610-618
    • /
    • 2008
  • It is not easy to compare the treatment processes and find an optimum operating condition by the experiments due to influent conditions, treatment processes, various operational conditions and complex factors in real wastewater treatment system and also need a lot of time and costs. In this paper, the activated sludge models are applied to four principal biological wastewater treatment processes, $A_2O$(anaerobic/anoxic/oxic process), Bardenpho(4 steps), VIP(Virginia Initiative Plant) and UCT(University of Cape Town), and are used to compare their environmental and economic assessment for four key processes. In order to evaluate each processes, a new assessment index which can compare the efficiency of treatment performances in various processes is proposed, which considers both environmental and economic cost. It shows that the proposed index can be used to select the optimum processes among the candidate treatment processes as well as to find the optimum condition in each process. And it can find the change of economic and environmental index under the changes of influent flowrate and aerobic reaction size and predict the optimum index under various operation conditions.

Nitrogen Removal in Fluidized Bed and Hybrid Reactor using Porous Media (다공성 담체를 이용한 유동상 및 하이브리드 반응기에서의 질소제거)

  • Jun, Byong-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.542-548
    • /
    • 2005
  • A fluidized bed reactor containing porous media has been known to be effective for nitrogen and organic matters removal in wastewater. The porous media which attached microbes plays important roles in simultaneous nitrification/denitrification (SND) due to coexistence of oxic, anaerobic and anoxic zone. For SND reaction, oxygen and organic substrates should be effectively diffused from wastewater into the intra-carrier zone. However, the overgrowth heterotrophic microbes at the surface of porous media may restrict from substrates diffusion. From these viewpoints, the existence and effect of heterotrophic bacteria at surface of porous media might be the key point for nitrogen removal. A porous media-membrane hybrid process was found to have improved nitrogen removal efficiency, due to stimulated denitrification as well as nitrification. Microelectrode studies revealed that although intra-media denitrification rate in a conventional fluidized bed was limited by organic carbon, this limitation was reduced in the hybrid process, resulting in the increased denitrification rate from 0.5 to $4.2\; mgNO_3-N/L/hr$.

Real-time Control of Biological Animal Wastewater Treatment Process and Stability of Control Parameters (생물학적 축산폐수 처리공정의 자동제어 방법 및 제어 인자의 안정성)

  • Kim, W.Y.;Jung, J.H.;Ra, C.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.251-260
    • /
    • 2004
  • The feasibility and stability of ORP, pH(mV) and DO as a real-time control parameter for SBR process were evaluated in this study. During operation, NBP(nitrogen break point) and NKP(nitrate knee point), which reveal the biological and chemical changes of pollutants, were clearly observed on ORP and pH(mV)-time profiles, and those control points were easily detected by tracking the moving slope changes(MSC). However, when balance of aeration rate to loading rate, or to OUR(oxygen uptake rate), was not optimally maintained, either false NBP was occurred on ORP and DO curves before the appearance of real NBP or specific NBP feature was disappeared on ORP curve. Under that condition, however, very distinct NBP was found on pH(mV)-time profile, and stable detection of that point was feasible by tracking MSC. These results might mean that pH(mV) is superior real-time control parameter for aerobic process than ORP and DO. Meanwhile, as a real-time control parameter for anoxic process, ORP was very stable and more useful parameter than others. Based on these results, a stable real-time control of process can be achieved by using the ORP and pH(mv) parameters in combination rather than using separately. A complete removal of pollutants could be always ensured with this real-time control technology, despite the variations of wastewater and operation condition, as well as an optimization of treatment time and capacity could be feasible.

Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant (바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구)

  • Shin, Jae-Suk;Kim, Sung-Chul;Cho, Kwang-Ju;Choi, Choong-Ho;Choi, In-Wook;Park, Jeong-Ja;Park, Goo-Hyeon
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.115-121
    • /
    • 2009
  • The hybrid constructed wetland(HCW) as tertiary treatment process of a bio industrial wastewater treatment plant was employed to estimate applications for the reuse of final effluent. Raw wastewater was sequently treated through chemical and biological treatment processes and the biologically treated water was flowed into the HCW. The HCW system was composed of two constructed wetlands connected in series; The one is the aerobic constructed wetland with natural air draft system whose driving force for air supply was the difference between the temperature of the air inside the wetland and the ambient air, and the other is the anaerobic/anoxic constructed wetland. Average influent concentrations of BOD, SS, T-N and T-P in the HCW were 53mg/L, 48mg/L, 34mg/L and 3mg/L, respectively. After being treated at HCW, final effluent concentrations of BOD, SS, T-N and T-P were 2.3mg/L, 1.2mg/L, 7.95mg/L and 0.83mg/L, respectively. Referring to a reuse standard for a sewage wastewater, final effluent could sufficiently be reuse as landscaping, washing or agriculture water. HCW system with the aerobic/anaerobic combined constructed wetland could be achieved a high removal efficiency because each constructed wetland was functionalized to be removed efficiently organics, nitrogen and phosphorus. HCW system could be estimated to be successful application as tertiary treatment process of a various industrial and municipal wastewater.

  • PDF

Optimization for Phosphorus Remove by Loess Ball Using Chromobacterium (Chromobacterium을 이용한 황토볼에 의한 인산 제거를 위한 최적화)

  • Choi Du Bok;Lee Choon-Boem;Cha Wol-Suk
    • Journal of Life Science
    • /
    • v.15 no.4 s.71
    • /
    • pp.584-589
    • /
    • 2005
  • To investigate factors affecting the removal of phosphorus from the practical wastewater in the F-STEP PROCESS using a loess ball and Chromobacterium WS 2-14, first, the loess ball size and calcining temperature, initial pH, initial phosphorus concentration, working temperature, and aeration were studied. A $2\~4mm$ of loess ball made at $960^{\circ}C$ of calcining temperature was the most suitable one for the removal of phosphorus. When the initial pH was increased from 3.0 to 6.0, the removal efficiency of phosphorus was increased. Especially, at 6.0 of initial pH, the maximum removal efficiency of phosphorus was $88.7\%$. The maximum removal efficiency of phosphorous was gained, 1.8mg/h when the initial concentration of phosphorous was 5.0mg/1. When the operating temperature was $30^{\circ}C$, the maximum removal efficiency of phosphorus was obtained. In the case of aeration, when it was increased from 0.5 to 5.0L/min, the removal efficiency of phosphorus was increased. On the other hand, above 7.0 L/min, the removal efficiency of phosphorus did not increased. Using the optimum operation conditions, pilot tests for the effective removal efficiency of phosphorus were carried out for 65 days. The average removal efficiency of phosphorus was $92.0\%$. The average removal efficiency of COD, BOD, and SS were 77.1, 74.2, and $86.4\%$, respectively. from the results, it can be concluded that F-STEP PROCESS using loess ball might be useful process for phosphorus removal.

Influence of Organic Acids Residual Concentration by the Change of F/M Ratio on Sludge Settleability in Advanced Sewage Treatment Processes (하.폐수 고도처리시 F/M비 변화에 따른 유기산 잔류 농도가 슬러지 침강성에 미치는 영향)

  • Park, Young-Ki;Kim, Young-Il;Kim, Sl-Ki
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.42-47
    • /
    • 2006
  • The biological nutrient treatment is formed with repetition and rearrangement of anaerobic, anoxic and oxic tank. In this case, VFAs is generated in the anaerobic tank and the anoxic tank. The VFAs is an important factor for removal of nitrogen and phosphate and SVI. So, in this study I investigated to find a relationship among the generation rate of the VFAs according to the change of F/M ratio and the characteristic which can eliminate organic matter and nitrogen according to the change of residual concentration of the VFAs and the efficiency of the process and also SVI in wastewater treatment. $A^2/O$ process was used for wastewater treatment. F/M ratio was under the control of the change of MLSS concentration. When the F/M ratio was changed from 0.16 to 0.08 kg-BOD/kg-MLSS/day, the VFAs's production volume increased based on the reduction of F/M ratio in batch reaction. And the residual concentration of the VFAs decreased at first and then increased later. SVI and SS were high when F/M ratio was $0.16kg/kg{\cdot}d$ and showed stable status when F/M ratio decreased $0.11{\sim}0.13kg/kg{\cdot}d$. However, SVI and SS continuously increased with decrease of F/M ratio and were high at $0.08kg/kg{\cdot}d$. In the result of comparison between residual concentration of the VFAs and denitrification rate in anoxic tank, the less residual volume of the VFAs was in anoxic tank, the higher denitrification ratio became. The optimal residual-concentration of the VFAs considering SVI and removal efficiency of nitrogenwas $1.4{\sim}2.2mg/L$. At that time F/M ratio was $0.11{\sim}0.13$ kg-BOD/kg-MLSS/day.

A study on Assessment Methodology for Best Treatment Technologies at Public Sewage Treatment Works in Korea (하수처리시설에서 최적처리기술 평가 방법론 고찰 - 미국과 유럽의 사례를 중심으로 -)

  • Jeong, Dong-Hwan;Cho, Yangseok;Choi, In-Cheol;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.4
    • /
    • pp.386-395
    • /
    • 2015
  • In order to assess sewage treatment technology necessary to achieve water quality criteria in the watershed and to ensure best treatment technology is applied in building and expanding PSTWs when establishing the Watershed Sewer System Maintenance Plan, it is necessary to develop assessment guidelines to determinate the best treatment technologies applicable to the public sewage treatment works(PSTWs). Sewage treatment technologies such as anaerobic-anoxic-aerobic treatment process are employed at PSTWs, and treatment efficiency varies due to many factors such as how the PSTWs are operated. Therefore, analyzing assessment guideline of best available technology(BAT) using currently in USA and EU, this study presents assessment parameters for the assessment guidelines to be used in determining the best treatment technologies applicable to PSTWs. We have a plan to implement pilot assessment in preparation for the final assessment guidelines based on the results of professionals survey and to determine weighted factors and assessment parameters using analytic hierarchy process (AHP).

Control of $NH_4-N$ in Wastewater Treatment Effluent According to Simplified ASM No. 1 (간략화된 활성슬러지 모델(ASM No. 1)을 이용한 유출수 중 암모니아성 질소의 제어에 관한 연구)

  • Kim, Shin-Geol;Choi, In-Su;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.548-555
    • /
    • 2007
  • The control of wastewater treatment has two merits; one is to regulate water quality of effluent and the other is to reduce the cost of wastewater treatment. The purpose of this study was to control the ammonium nitrogen in effluent that is known to cause eutrophication. The control was based on simplified ASM No. 1 which had 3 component materials and 8 coefficients, and the control method was as following. Firstly the ammonium concentration of inflow was measured and the optimal aeration time in effluent was determined according to simplified ASM No. 1 to be 1.0 mg/L. If ammonium concentration of effluent was not equal to 1.0 mg/L, the influent ammonium was corrected by adaptive control. These processes above were repeatedly performed. The SBR running aerobic-anoxic phase had been controlled for 1 month with this method. As a result, the ammonium concentration of the effluent showed in the range of $0.22\sim3.1$ mg/L with an average concentration of 1.1 mg/L. The adaptive control method used in this study was found very useful to control and predict the effluent concentration of ammonium.

Evaluation of Operational Options of Wastewater Treatment Using EQPS Models (EQPS 모델을 이용한 하수처리장 운전 평가)

  • Yoo, Hosik;Ahn, Seyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.401-408
    • /
    • 2018
  • EQPS (Effluent Quality Prediction System, Dynamita, France) was applied to analyze the appropriateness of the design of a bioreactor in A sewage treatment plant. A sewage treatment plant was designed by setting the design concentration of the secondary clarifier effluent to total nitrogen and total phosphorus, 10 mg/L and 1.8 mg/L, respectively, in order to comply with the target water quality at the level of the hydrophilic water. The retention time of the 4-stage BNR reactor was 9.6 hours, which was 0.5 for the pre-anoxic tank, 1.0 for the anaerobic tank, 2.9 for the anoxic tank, and 5.2 hours for the aerobic tank. As a result of the modeling of the winter season, the retention time of the anaerobic tank was increased by 0.2 hours in order to satisfy the target water quality of the hydrophilic water level. The default coefficients of the one step nitrification denitrification model proposed by the software manufacturer were used to exclude distortion of the modeling results. Since the process modeling generally presents optimal conditions, the retention time of the 4-stage BNR should be increased to 9.8 hours considering the bioreactor margin. The accurate use of process modeling in the design stage of the sewage treatment plant is a way to ensure the stability of the treatment performance and efficiency after construction of the sewage treatment plant.