• 제목/요약/키워드: 몬데카를로 시뮬레이션

검색결과 6건 처리시간 0.017초

몬데카를로 소프트 헨드오프 모델링 (Monte Carlo Soft Handoff Modeling)

  • 추현승;정민영;홍인기
    • 한국시뮬레이션학회논문지
    • /
    • 제13권1호
    • /
    • pp.1-9
    • /
    • 2004
  • In this paper some models for obtaining the distribution of a sojourn time in CDMA cellular systems are proposed. Knowledge on this is essential for reliable modeling of the soft handoff and for solving other related problems in the analysis of cellular system. The proposed model is based on random walk and can be adopted to different conditions. Analytical results can be obtained that lead to a quite complicated numerical scheme so simulation models are used for Monte Carlo experiments. Main assumptions include different kinds of mobile carriers (pedestrians and transport passengers) and round shape of a cell. The scheme for simulation experiments is presented along with the discussion of simulation results.

  • PDF

의료방사선 조영제를 이용한 차폐체 개발; 몬테카를로 시뮬레이션을 통한 황산바륨과 요오드의 차폐능 비교분석 (Development of Shielding using Medical Radiological Contrast Media; Comparison Analysis of Barium Sulfate Iodine Shielding ability by Monte Carlo Simulation)

  • 김선칠
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.329-334
    • /
    • 2017
  • 본 연구는 의료방사선 차폐를 위해 의료 환경에 적합한 친환경 소재를 찾아 방사선 차폐 시트 제작의 가능성을 추정하고자 하는 것이다. 현재 차폐 소재로 주로 사용되는 납을 대신한 텅스텐 제품이 많이 있으나, 경제성으로 인해 경량의 차폐 시트의 대량생산에는 다소 문제가 있다. 이러한 문제점을 해결하기 위해 경제성 있는 경량 친환경 소재를 필요로 한다. 이러한 소재로써 본 연구에서는 황산바륨과 요오드를 제안하였다. 두 물질은 방사선 촬영에서 이미 조영제로 사용되고 있어 방사선을 흡수하는 특성으로 차폐 재료로써 일정 영역에서 충분히 차폐효과가 있을 것으로 예측하고 있다. 따라서 본 연구에서는 방사선 차폐 재료로 검증하기 위해 몬테카를로 시뮬레이션을 이용하여 모의 추정하였다. 황산바륨과 요오드 등 조영제인 경우 고에너지 영역에서 방사선 흡수효과가 크게 나타나, 의료방사선 고관전압 촬영영역 120 kV의 두께별 에너지영역에서 두 차폐물질의 유효성을 평가하였다. 모의 추정 결과 두 물질 모두 차폐의 유효성을 추정할 수 있었다. 요오드가 황산바륨보다 차폐효과 높았으며, 0.05mm 두께에서는 효과성이 크게 나타났다. 따라서 방사선차폐 시트의 제작 재료로 방사선 조영제인 요오드도 황산바륨과 같이 가능하다는 것을 몬데카를로 시뮬레이션을 통해 확인 할 수 있다.

신뢰도지수 및 몬데카를로 시뮬레이션을 이용한 원전 감육배관의 확률론적 손상역학 평가 (Probabilistic Damage Mechanics Assessment of Wall-Thinned Nuclear Piping Using Reliability Method and Monte-Carlo Simulation)

  • 이상민;윤강옥;장윤석;최재붕;김영진
    • 대한기계학회논문집A
    • /
    • 제29권8호
    • /
    • pp.1102-1108
    • /
    • 2005
  • The integrity of nuclear piping systems has to be maintained sufficiently all the times during operation. In order to maintain the integrity, reliable assessment procedures including fracture mechanics analysis, etc, are required. Up to now, the integrity assessment has been performed using conventional deterministic approach even though there are lots of uncertainties to hinder a rational evaluation. In this respect, probabilistic approach is considered as an appropriate method for piping system evaluation. The objectives of this paper are to develop a probabilistic assessment program using reliability index and simulation technique and to estimate the damage probability of wall-thinned pipes in secondary systems. The probabilistic assessment program consists of three evaluation modules which are first order reliability method, second order reliability method and Monte Carlo simulation method. The developed program has been applied to evaluate damage probabilities of wall-thinned pipes subjected to internal pressure, global bending moment and combined loading. The sensitivity analysis results as well as prototypal evaluation results showed a promising applicability of the probabilistic integrity assessment program.

풀밴드 몬데카를로 방법을 이용한 GaAs 임팩트이온화의 온도 의존성에 관한 연구 (A Study on the Temperature dependent Impact ionization for GaAs using the Full Band Monte Carlo Method)

  • 고석웅;유창관;정학기
    • 한국정보통신학회논문지
    • /
    • 제4권3호
    • /
    • pp.697-703
    • /
    • 2000
  • 임팩트이온화현상은 소자의 크기가 점점 작아지면서, 높은 에너지에 있는 hot carrier 전송 을 해석하기 위해 매우 중요하므로 소자의 시뮬레이션에 정확한 임팩트이온화모델이 필수적이다. 털 연구에서는 의사포텐셜방법을 사용하여 풀밴드모델을 구하고, 임팩트이온화율은 수정된 Keldysh 공식을 이용하여 유도하였다. 본 연구에서는 Gahs 임팩트이은화의 온도의존특성을 조사하기 위하여 Monte Carlo 시뮬레이터를 제작하여 임팩트이온화계수를 구하였다. 결과적으로, 임팩트이온화계수는 300K에서 실험값과 잘 일치하였다. 또한 에너지는 전계가 증가할수록 증가하고, 높은 온도에서는 포논 산란의 emission mode가 높기 때문에 에너지가 감소함을 알 수 있었다. 임팩트이온화의 대수 fitting 함수 식은 온도와 전계에 대해 2차식으로 표현하였다. 대수 fitting 함수의 오차는 대부분 5%이내에 머물렀다. 그러므로 대수식으로 표현된 임팩트 이온화계수는 온도에 의존함을 알았고, 임팩트이온화계수를 구하는데 시간을 절약할 수 있다.

  • PDF

몬데카를로 시뮬레이션을 이용한 검출기의 크기효과 제거 (Deconvolution of Detector Size Effect Using Monte Carlo Simulation)

  • Park, Kwangyl;Yi, Byong-Yong;Young W. Vahc
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.100-104
    • /
    • 2004
  • 선량 측정기의 공간적인 반응특성 때문에 나타나는 detector의 크기효과는 임상적인 선량측정을 부정확하게 만드는 중요한 원인이기에 많은 연구의 대상이 되어왔다. 관례적으로 detector response kernel은 detector 자체의 크기가 측정한 방사선의 선량분포에 대해 미친 영향에 대한 정보를 포함하고 있다. 이 kernel에 대해 다양한 수학적 모델들이 제안되었고 실험적으로 이론적으로 연구되어왔다. 이 논문은 convolution이론과 Monte Carlo simulation만을 이용하여 detector의 kernel을 결정하는 방법을 제시한다. 이 수치해석적인 방법을 사용하여 물 phantom에 잠긴 Farmer형 ion chamber의 detector response kernel을 계산하였다. 계산된 kernel은 기존의 parabolic 모델의 특성과 Gaussian 모델의 특성을 동시에 나타내고 있다. 이 kernel과 deconvolution 방법을 사용하여 측정된 6MV, 10${\times}$10 $\textrm{cm}^2$, 0.5${\times}$10 $\textrm{cm}^2$ 광자선으로부터 크기효과를 제거하였다. 크기효과가 제거된 방사선의 선량분포는 꼬리부분을 제외하고는 film이나 pin-point ion chamber에 의해 측정된 결과와 유사한 선량분포를 나타냈다.

  • PDF