• Title/Summary/Keyword: 목표하중

Search Result 194, Processing Time 0.024 seconds

An Investigation into differences between codes for the Moment Strength of Deck Plates (데크플레이트의 휨 강도에 관한 기준 비교 연구)

  • Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2003
  • This research aimed to experimentally and theoretically investigate the moment strength of deck plates. A moment experiment was carried out using a full-scale 14 specimen. To prevent local buckling, the point load was applied at 1/4 points. After the experiment, theoretical analysis was conducted and the differences between various codes were identified. The experimental results were compared with AISI (the American Iron and Steel Institute), EC (Euro Code) 3, and KS (Korea Standard) codes. Analysis results are summarized as follows: (1) the failure mode was influenced by local buckling at the midpoint of the beam and/or at the intermediate loading point: (2) if yielding first occurred at the tension side, the moment strength would increase as the plastic reservation of the tension zone acted: (3) the experimental results were closest to the EC3 codes in which the partial plastic reservation was considered; (4) statistical evaluation based on the EC3 Annex Z showed that the partial resistance safety coefficient calculated applying to the EC3 formula, $^{\circ}{_M}$, was placed within 1.1 which was the target value of EC3 code; and (5) the analytical power of AISI and KS codeswere expected to improve into the level of EC3 codes if the concept of plastic reservation of the tension side would be introduced to them.

Strength Assessment of 8m-class High-Speed Planing Leisure Boat (8m급 고속 활주선형 레저보트의 구조강도 평가)

  • Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.418-423
    • /
    • 2018
  • Recently, research and development of high-value leisure vessels has been carried out in Korea to revitalize the marine leisure industry and tap into the global maritime leisure market. FRP composite materials, which have excellent physical properties and are available for the manufacture of light hulls, are used widely. One of the most important design technologies is to secure structural safety of leisure vessels made from FRP composite materials. In this study, the structural strength was assessed for the design of an 8-meter high-speed planing leisure boat made from FRP composite materials. The design loads to verify the structural safety were calculated according to the rules for the classification of high speed light craft (KR, 2015), and structural analysis was conducted using a finite element model composed of an isotropic shell element, which has equivalent bending rigidity with the FRP sandwich panel. The analysis results were compared with the results of the strength test for fabricated specimens, and all internal structural components are sufficiently satisfied with the structural strength.

Analysis Model of the Stress Ribbon Bridge considering the Construction Stage (시공단계가 고려된 스트레스 리본 교량의 해석 모델)

  • Yun, Kyung-Min;Kim, Kee-Dong;Lee, Chin-Ok;Lim, Nam-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6898-6905
    • /
    • 2014
  • A stress ribbon bridge is a PSC structure that behaves as a reverse arch structure due to post-tensioned thin deck of the catenary type. In foreign countries, the stress ribbon bridge is recognized as the minimum destruction of nature and beautiful bridge, and has many construction examples as pedestrian and car bridges. On the other hand, there have been few studies in Korea. In this study, the FE Analysis model was established for different construction stages considering the nonlinear and time-dependent behaviors. The FE model was verified by a comparison with the numerical results and the behavior was analyzed for the different construction stages.

The shear strength of RC rectangular sectional columns considering displacement ductility (변위연성도를 고려한 RC 사각단면 기둥의 전단강도)

  • Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.37-47
    • /
    • 2010
  • In order to attain enhanced seismic performance of RC bridges, premature shear failure prior to the achievement of target ductilities of the piers should be prevented. For this purpose, a reliable shear strength evaluation is required. The shear strength of an RC column subjected to a lateral force decreases with an increase in ductility. Many empirical equations for the shear strength have been proposed by many researchers. However, there are many discrepancies in the initial shear strength in the low ductility range, and in the decrease rate according to the ductility. In this study, a new empirical equation of shear strength considering the displacement ductility effect has been proposed, in which the initial shear strength equation proposed by the authors was revised on the basis of the investigation of many other researchers' test results. The resulting improvement in accuracy is confirmed by comparison with other empirical equations.

Reliability-based Design Criteria for Reinforced Concrete Structures Based on Partial and Combined Resistance Factor Formats (부분(部分) 및 조합저항계수형식(組合抵抗係數形式)에 의한 철근(鐵筋)콘크리트구조(構造)의 신뢰성(信賴性) 계기준(計基準))

  • Oh, Byung Hwan;Lee, Seong Lo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.87-97
    • /
    • 1990
  • There is the need to balance safety, economy and serviceability in all phases of society problems. This is especially true in structural code formulation. where a framework is established by which practicing structural engineers can be assured of designing structures that reasonably meet the above three objectives. The existing design codes, which are generally based on the structural theory and certain engineering experience, do not realistically consider the uncertainties of loads and resistances and the basic reliability concepts. The purpose of the present study is therefore to develop the realistic reliability-based design criteria to secure adequate safety arid reliability, and to derive the models for partial and combined resistance factor formats. To this end, the reliability levels of our existing design code for concrete structures are first evaluated and the target reliabilities are determined, the new code formats are evolved from these target reliabilities. The present study indicates that the proposed formats exhibit relatively-uniform reliability and reasonably take into account the different material characteristics of concrete and steel in concrete structures.

  • PDF

Design of Unbend Braces to Satisfy Given Performance Acceptance Criteria (성능수준 만족을 위한 가새헝 소성 감쇠기의 설계)

  • 김진구;김유경;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.6
    • /
    • pp.47-54
    • /
    • 2001
  • Unbond brace hysteretic dampers are generally used to prevent or decrease structural damage in building structures subjected to strong earthquake by its energy dissipating hysteretic behavior. In the study, a straightforward design procedure for unbond brace hysteretic dampers was developed. The required amount of equivalent damping to satisfy given performance acceptance criteria was obtained conveniently based on the capacity spectrum method without carrying out time-consuming nonlinear dynamic time history analysis. Then the size of the unbond braces is determined from the required equivalent damping. Parametric study has been performed for the design variables such as natural period, yield strength, the stiffness after the first yield stress of the unbond brace. The procedure was applied to 5-story and 10-story steel frames for verification of the proposed method. According to the earthquake time history analysis results, the maximum displacement of the model structure with unbond braces supplied in accordance with the proposed method corresponds well with the given target displacement.

  • PDF

Design of Battery-Supporting Structure for Reducing Deflection of On-Line Electric Vehicles (OLEV의 처짐량 개선을 위한 배터리 지지구조물 설계)

  • Park, Hong-Ik;Yoo, Ji-Sue;Lee, Jun-Young;Lee, Sang-Beom;Yim, Hong-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.211-216
    • /
    • 2012
  • This paper presents methods to reduce the deflection of the battery-supporting structure on on-line electric vehicles (OLEVs). First, by testing various battery locations, a location is found that increases the dynamic stiffness of the OLEV. Second, static analysis is conducted to analyze the maximum deflection caused by the battery weight. In order to reduce the amount of deflection, the contributions of the battery-supporting structures are analyzed, and reinforcements are inserted. Then, another static analysis is conducted to compare the results of the base model and modified model. Consequently, through the static analysis, both the base model and modified model are similarly improved in terms of deflection, but the modified model is better than the base model at reducing the mass.

Evaluation of Load Capacity and Toughness of Porous Concrete Blocks Reinforced with GFRP Bars (GFRP 보강 다공성 콘크리트 블록의 내력 및 인성 평가)

  • Jung, Seung-Bae;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.403-409
    • /
    • 2017
  • In this study, mix proportioning of porous concrete with compressive strength and porosity exceeding 3MPa and 30%, respectively, was examined and then load capacity and flexural toughness of the porous concrete block were evaluated according to the different arrangements of the GFRP bars. To achieve the designed requirements of porous concrete, it can be recommended that water-to-cement ratio and cement-to-coarse aggregate ratio are 25% and 20%, respectively, under the aggregate particle distribution of 15~20mm. The failure mode of porous concrete blocks reinforced with GFRP bars was governed by shear cracks. As a result, very few flexural resistance of the GFRP was expected. However, the enhanced shear strength of porous concrete due to the dowel action of the GFRP bars increased the load capacity and toughness of the blocks. The porous concrete blocks reinforced with one GFRP bar at each compressive and tensile regions had 2.1 times higher load capacity than the companion non-reinforced block and exhibited a high ductile behavior with the ultimate toughness index ($I_{30}$) of 43.4.

Optimization of Door Hinges of a Large Refrigerator (대형 냉장고 도어 힌지의 최적 설계)

  • Youn, Seong-Jun;Noh, Yoo-Jeong;Kim, Seok-Ro;Kim, Ji-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.1
    • /
    • pp.71-78
    • /
    • 2014
  • Door hinges of large refrigerators are required to ensure that the doors open and close smoothly in addition to supporting door weights and enduring the impact loads due to door opening and closing. However, door hinge design is difficult because of complex hinge mechanisms and sensitive structural safety. In this study, the mechanism satisfying the required spring response, space constraints, and structural strength is optimized, and the volume of the outer frame covering the hinge mechanism is minimized for reducing production costs. The entire design process is automated using the PIDO(Progress Integration and Design Optimization) technique, which achieves an efficient design process. Therefore, the frame mass is reduced to 24%, and the mechanism performance and structural stability are improved.

Design of Vertically Adjustable Transition Piece of Concrete Gravity Based Substructure for Offshore Wind Turbine (수직도 조정이 가능한 콘크리트 중력식 해상풍력 지지구조물 연결부 설계)

  • Shim, WunBo;Ahn, Jin-Young;Kwak, Dong-Woo;Bae, Kyung-Tae;Zi, Goangseup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.42-51
    • /
    • 2018
  • Verticality problem during the installation process in offshore wind turbine substructures could degrade the safety of the whole structures. Therefore, in this paper, the design of vertically adjustable transition piece(T.P.), using a PS anchor and grout of anchor socket in concrete gravity based substructure(G.B.S.), was proposed. T.P. was designed for 5MW offshore wind trubine and can adjust up to $0.5^{\circ}$ in verticality, occurred during installation. The design plan for each members and design procedure for T.P. was proposed. Then based on the proposed design, actual design targeting sea of Jeju-island was carried out. Finally, by use of non-linear 3D Finite Element Analysis(F.E.A.), evaluation of design was performed. As a result of evaluation, by checking load transfer mechanism and stress of T.P, proposed design was considered safe up to $0.5^{\circ}$ of adjustment.