• Title/Summary/Keyword: 목대상

Search Result 3,175, Processing Time 0.027 seconds

Usefulness assessment of the Volumetric Modulated Arc Therapy technique for reducing low-dose areas during radiotherapy for patients with multiple metastatic cancers (다발성 전이암 환자의 방사선치료 시 저선량 영역 감소를 위한 용적조절 회전 방사선치료(Volumetric Modulated Arc Therapy) 기법의 유용성 평가)

  • Yun-won Choi;Dong-min Jeong;Se-young Kim;Ryeong-hwang Park;I-ji Kim;Yong-wan Cho;Yongjae Kwon;Byeol-nim Park;Gyeong-min Yoo;Ho-kyung Moon;Dong-jae Jang;Jae-young Lee;Dayoung Lim;Sang-gyu Lee;Jong-geol Baek
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.23-31
    • /
    • 2023
  • Purpose: The purpose of this study is to evaluate the usefulness of Non-Treat Functionality Volumetric Modulated Arc Therapy(NTF-VMAT) and Treat Functionality VMAT(TF-VMAT) treatment plans in reducing the low-dose area during radiation therapy for patients with multiple metastatic cancers. Materials and Methods: The study was conducted on an Arccheck phantom, treatment planning target locations were set in pairs at intervals of 2 cm, 4 cm, and 6 cm on the X, Y, and Z axes. Based on these location settings, the volume of the low-dose area in NTF-VMAT and TF-VMAT was measured and compared. Results: The results of the study showed that, within a prescription dose range of 10% ~ 70%, the difference in low-dose area volumes across each axis was as follows: On the X-axis, there was a maximum difference of -47.6% and a minimum difference of -2.2%. On the Y-axis, there was a maximum difference of -17.5% and a minimum difference of -7.3%. The Z-axis showed a maximum difference of -39.7%, with the smallest difference being -6.8%. Conclusion: In radiation therapy for patients with multiple metastatic cancers, the TF-VMAT treatment plan was able to reduce the low-dose area by 10-40% compared to NTF-VMAT. This suggests that utilizing Treat Functionality, which includes the Island block technique, improves dose distribution and minimizes side effects, making it beneficial for the treatment of patients with multiple metastatic cancers.

  • PDF

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF

The Influence of Organizational Commitment, Job Commitment and Job Satisfaction on Professionalism Perceived by Radiotechnologists Working in the Department of Radiation Oncology (방사선종양학과에 근무하는 방사선사의 조직몰입, 직무몰입, 직무만족이 전문 직업성에 미치는 영향)

  • Gim, Yang-Soo;Lee, Sun-Young;Lee, Joon-Seong;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 2012
  • Purpose: The study is to check the specialty of radiotherapists working in the department of radiation oncology and find job satisfaction, organizational commitment and job commitment having an effect on professional parts. After making analysis of the mutual relation, it is to provide radiotechnologists with making progress in the future. Materials and Methods: From March 2 to March 30, we had carried out a survey with email. It is possible to have 272 questionnaires answered in the survey. We make use of SPSS 13.0 for Windows to analyze the data collected for study. Frequency and a percentage are meant to show general characteristics, and t-test and ANOVA to do the difference between general properties and professionalism. Pearson's correlation coefficient also is meant to do the correlation of professionalism, organizational job commitment and job satisfaction, and multiple regression analysis to do the factor for a relevant variable to affect professionalism. Results: There are subdivisions in the professionalism informing us of the self-regulation $17.74{\pm}2.32/3.55{\pm}.46$, a sense of calling $17.58{\pm}2.63/3.52{\pm}.53$, reference of the professional $17.14{\pm}2.39/3.43{\pm}.48$, service to the public $15.97{\pm}2.48/3.19{\pm}50$, and autonomy $15.68{\pm}2.28/3.14{\pm}46$. Grand mean turns out to be $83.89{\pm}7.63$(Summation of items)/$3.37{\pm}0.49$ (Numbers of items). When it comes to a statistical relation between general characteristics and professionalism, the statistics have it that these come within age (P<.001), period of employment (P<.001), education status (P<.05), a monthly income (P<.001), radiotherapists who get a special license (P<.001), the position (P<.001), and an opportunity for developing (P<.001). As a result of organizational commitment, job commitment, and job satisfaction, grand mean in organizational commitment proves to be $80.10{\pm}8.15/3.34{\pm}.34$. There are subvisions showing affective commitment $28.64{\pm}4.61$/3.58, continuance commitment $27.54{\pm}4.22/3.44{\pm}.53$, and normative commitment $23.95{\pm}2.94/2.99{\pm}.37$ in order of precedence. The average grade in job commitment is $32.47{\pm}5.77/3.30{\pm}.60$ and that in job satisfaction is $63.39{\pm}10.16/3.17{\pm}.51$, respectively. We find the positive relationship between professionalism and organizational commitment (r=.522, P<.05), between professionalism and job commitment (r=.444, P<.05), and between professionalism and job satisfaction (r=.507, P<.05). And we also get the positive relationship between organizational commitment and job commitment (r=.549, P<.05), between organizational commitment and job satisfaction (r=.433, P<.05), and between job commitment and job satisfaction (r=.462, P<.05). To catch the factors influencing the professionalism of radiotherapists, we used multiple regression analysis. According to the final model, it appears affective commitment (B=.755, P<.05), normative commitment (B=.305, P<.05), job satisfaction (B=.092, P<.05), an opportunity for developing (B=-1.505, P<.05), and the position (B=-1.155, P<.05) in order of precedence. It seems that explaining influece on $R^2$ is 0.504. Conclusion: The results of the factors that influence professionalism working as radiotherapists in the department of radiation oncology have it that the more affective commitment, normative commitment, and job satisfaction we feel, the more professionalism we recognize. We think that the focus of professionalism is increased if getting the chances for radiotherapists to have little to do with developing opportunities given.

  • PDF

The Three Types of Clinical Manifestation of Cow's Milk Allergy with Predominantly Intestinal Symptoms (위장관 증세 위주로 발현하는 영유아기 우유 알레르기 질환의 3가지 임상 유형에 관한 고찰)

  • Lee, Jeong-Jin;Lee, Eun-Joo;Kim, Hyun-Hee;Choi, Eun-Jin;Hwang, Jin-Bok;Han, Chang-Ho;Chung, Hai-Lee;Kwon, Young-Dae;Kim, Yong-Jin
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.1
    • /
    • pp.30-40
    • /
    • 2000
  • Purpose: During the first year of life, cow's milk protein is the major offender causing food allergy. Cow's milk allergy (CMA) affects 2~7% of infants, of which approximately one-half show predominantly gastrointestinal symptoms. We studied the clinical types of cow's milk allergy with predominantly gastrointestinal symptoms (CMA-GI) of childhood. Methods: The retrospective study was performed on 30 (male 22, female 8) patients who had diagnosed as CMA-GI during 2 years and 3 months from March 1995 to June 1997. Results: 1) Children with CMA-GI presented in the three types of clinical manifestation on the basis of time to reaction to milk ingestion: Quick (Q) onset (5 cases), Slow (S) onset (20 cases), Quick & Slow (Q&S) (5 cases). 2) Age on admission of the three groups was significantly different (p<0.05): (Q onset: $81.4{\pm}67.1$ days, S onset: $31.9{\pm}12.7$ days, Q&S: $366.0{\pm}65.0$ days). Although the body weight at birth was 10~95 percentile in all patients, body weight on admission was different: (Q onset: 10~50 percentile, S onset: below 10 percentile, Q&S: 10~25 percentile). S onset group was significantly different compared with other groups (p<0.05) and 90% of this one was failure to thrive below 3 percentile. 3) Peripheral leukocyte counts were as followings: (Q onset: $5,700{\sim}12,300/mm^3$, S onset: $10,000{\sim}33,400/mm^3$, Q&S: $5,200{\sim}14,900/mm^3$). Slow onset group was significantly different compared with other groups (p<0.05). Serum albumin levels on admission were as followings: (Q onset: $4.2{\pm}0.4\;g/dl$, S onset: $3.0{\pm}0.3\;g/dl$, Q&S: $4.0{\pm}0.3\;g/dl$). S onset group was significantly different compared with other groups (p<0.05) and 85% of this one was below 3.5 g/dl. 4) Although morphometrical analysis on small intestinal mucosa did not show enteropathy in Q onset and Q&S groups, all cases of S onset revealed enteropathy: 45% of this one showed subtotal villous atrophy, 55 % showed partial villous atrophy. 5) Allergic reaction test to other foods was not performed in S onset group because of ethical problem and high risk in general condition. In Q onset group, allergic reaction to one or two other foods: soy formula, weaning formula and eggs. Q&S goup revealed allergic reactions to several foods or to most of all foods except protein hydrolysate formula: eggs, potatos, some kinds of sea food, apples, carrots, beef and chicken. 6) Serum IgE level, peripheral eosinophil counts, milk RAST, soy RAST, skin test were not significantly different among groups. Conclusion: CMA-GI may present in three clinical ways on the basis of time to reaction to milk ingestion, typical clinical findings and morphologic changes in the small bowel mucosal biopsy specimens. This clinical subdivision might be helpful in diagnostic and therapeutic approaches in CMA-GI. Early suspicion is mandatory especially in S onset type because of high risks with malnutrition and enteropathy.

  • PDF

Results of Preoperative Concurrent Chemoradiotherapy for the Treatment of Rectal Cancer (직장암의 수술 전 동시적 항암화학방사선치료 결과)

  • Yoon, Mee-Sun;Nam, Taek-Keun;Kim, Hyeong-Rok;Nah, Byung-Sik;Chung, Woong-Ki;Kim, Young-Jin;Ahn, Sung-Ja;Song, Ju-Young;Jeong, Jae-Uk
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.247-256
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate anal sphincter preservation rates, survival rates, and prognostic factors in patients with rectal cancer treated with preoperative chemoradiotherapy. Materials and Methods: One hundred fifty patients with pathologic confirmed rectal cancer and treated by preoperative chemoradiotherapy between January 1999 and June 2007. Of the 150 patients, the 82 who completed the scheduled chemoradiotherapy, received definitive surgery at our hospital, and did not have distant metastasis upon initial diagnosis were enrolled in this study. The radiation dose delivered to the whole pelvis ranged from 41.4 to 46.0 Gy (median 44.0 Gy) using daily fractions of $1.8{\sim}2.0\;Gy$ at 5 days per week and a boost dose to the primary tumor and high risk area up to a total of $43.2{\sim}54\;Gy$ (median 50.4 Gy). Sixty patients (80.5%) received 5-fluorouracil, leucovorin, and cisplatin, while 16 patients (19.5%) were administered 5-fluorouracil and leucovorin every 4 weeks concurrently during radiotherapy. Surgery was performed for 3 to 45 weeks (median 7 weeks) after completion of chemoradiotherapy. Results: The sphincter preservation rates for all patients were 73.2% (60/82). Of the 48 patients whose tumor was located at less than 5 cm away from the anal verge, 31 (64.6%) underwent sphincter-saving surgery. Moreover, of the 34 patients whose tumor was located at greater than or equal to 5 cm away from the anal verge, 29 (85.3%) were able to preserve their anal sphincter. A pathologic complete response was achieved in 14.6% (12/82) of all patients. The downstaging rates were 42.7% (35/82) for the T stage, 75.5% (37/49) for the N stage, and 67.1% (55/82) for the overall stages. The median follow-up period was 38 months (range $11{\sim}107$ months). The overall 5-year survival, disease-free survival, and locoregional control rates were 67.4%, 58.9% and 84.4%, respectively. The 5-year overall survival rates based on the pathologic stage were 100% for stage 0 (n=12), 59.1% for stage I (n=16), 78.6% for stage II (n=30), 36.9% for stage III (n=23), and one patient with pathologic stage IV was alive for 43 months (p=0.02). The 5-year disease-free survival rates were 77.8% for stage 0, 63.6% for stage I, 58.9% for stage II, 51.1% for stage III, and 0% for stage IV (p<0.001). The 5-year locoregional control rates were 88.9% for stage 0, 93.8% for stage I, 91.1% for stage II, 68.2% for stage III, and one patient with pathologic stage IV was alive without local recurrence (p=0.01). The results of a multivariate analysis with age (${\leq}55$ vs. >55), clinical stage (I+II vs. III), radiotherapy to surgery interval (${\leq}6$ weeks vs. >6 weeks), operation type (sphincter preservation vs. no preservation), pathologic T stage, pathologic N stage, pathologic overall stage (0 vs. I+II vs. III+IV), and pathologic response (complete vs. non-CR), only age and pathologic N stage were significant predictors of overall survival, pathologic overall stage for disease-free survival, and pathologic N stage for locoregional control rates, respectively. Recurrence was observed in 25 patients (local recurrence in 10 patients, distant metastasis in 13 patients, and both in 2 patients). Acute hematologic toxicity ($\geq$grade 3) during chemoradiotherapy was observed in 2 patients, while skin toxicity was observed in 1 patient. Complications developing within 60 days after surgery and required admission or surgical intervention, were observed in 11 patients: anastomotic leakage in 5 patients, pelvic abscess in 2 patients, and others in 4 patients. Conclusion: Preoperative chemoradiotherapy was an effective modality to achieve downstaging and sphincter preservation in rectal cancer cases with a relatively low toxicity. Pathologic N stage was a statistically significant prognostic factor for survival and locoregional control and so, more intensified postoperative adjuvant chemotherapy should be considered in these patients.

Internet Addiction in Adolescents and its Relation to Sleep and Depression (청소년의 인터넷 중독 : 수면, 우울과의 관련성)

  • Song, Ho-Kwang;Jeong, Mi-Hyang;Sung, Da-Jung;Jung, Jung-Kyung;Choi, Jin-Sook;Jang, Yong-Lee;Lee, Jin-Seong
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.2
    • /
    • pp.100-108
    • /
    • 2010
  • Objectives: "Internet-addiction" came into common use not only in clinical setting but also in everyday life. But, pathophysiology and diagnostic criteria of the internet addiction remain unknown. Because adolescents are in developing period, they might be vulnerable to the internet addiction, depression and sleep-related problem. The objectives of this study were to investigate the characteristics of internet addiction and its association with sleep pattern and depression in Korean adolescence. Methods: Subjects were 799 middle and high school students in Seoul, Korea. We administered a self-reported questionnaire including socio-demographic data, Korean versions of Young's Internet Addiction Scale (YIAS), Pittsburgh Sleep Quality Index (PS-QI), the Center for Epidemiologic Studies for Depression Scale (CES-D) and questions about internet using patterns. Data of 696 subjects were included in analysis. Chi-square tests were used to analyze proportional differences, and ANOVA with post-hoc tests were used to analyze differences among groups. Partial correlation analyses were performed to analyze the correlation of internet addiction with other variables (two-tailed, p<0.05). Results: Of the 696 participants (grade 2 of middle school; M2 135 vs. grade 1 of high school; H1 238 vs. grade 2 of high school; H2 323), 2.0% (n=14) were internet-addicted (IA), 27.7% (n=193) were over-using (OU) and 70.3% (n=489) were not-addicted (NA). The mean scores of YIAS, PSQI and CES-D scores were 35.24${\pm}$12.78, 5.53${\pm}$3.04 and 16.72${\pm}$8.69, respectively. In higher grade students, average total sleep time was shorter (M2 426.20${\pm}$67.68 min. vs. H1 380.47${\pm}$62.57 min. vs. H2 354.67${\pm}$73.37 min., F=51.909, p<0.001), and PSQI (4.69${\pm}$3.14 vs. 5.42${\pm}$3.15 vs. 5.97${\pm}$2.83, F=8.871, p<0.001) CES-D (13.53${\pm}$8.37 vs. 16.96${\pm}$8.24 vs. 17.87${\pm}$8.84, F=12.373, p<0.001) scores were higher than those of lower grade students. Comparing variables among IA, OU and NA groups, computer using time not for study (96.36${\pm}$63.31 min. vs. 134.92${\pm}$86.79 min. vs. 213.57${\pm}$136.87 min., F=34.287, p<0.001) and portable device using time not for study (84.22${\pm}$79.11 min. vs. 96.97${\pm}$91.89 min. vs. 152.31${\pm}$93.64 min., F= 5.400, p=0.005) were different among groups. PSQI (5.26${\pm}$2.97 vs. 6.08${\pm}$2.97 vs. 7.50${\pm}$4.41, F=8.218, p<0.001) and CES-D scores (15.40${\pm}$8.08 vs. 19.05${\pm}$8.42 vs. 30.43${\pm}$13.69, F=32.692, p<0.001) were also different among groups. YIAS score were correlated with computer using time not for study (r=0.356, p<0.001) and portable device using time not for study (r= 0.136, p<0.001). PSQI score (r=0.237, p<0.001) and CES-D score (r=0.332, p<0.001). YIAS score and PSQI score (r=0.131, p= 0.001), YIAS and CES-D score (r=0.265, p<0.001), PSQI score and CES-D score (r=0.357, p<0.001) were correlated each other. Conclusion: These results suggested that adolescents' internet-addiction was correlated with not only computer and portable device using time not for study but also depression and sleep-related problems. We should pay attention to depression and sleep-related problems, when evaluating internet-addiction in adolescents.

  • PDF

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

The Study of Dose Change by Field Effect on Atomic Number of Shielding Materals in 6 MeV Electron Beam (6 MeV 전자선의 차폐물질 원자번호와 조사야 크기에 따른 선량변화 연구)

  • Lee, Seung Hoon;Kwak, Keun Tak;Park, Ju Kyeong;Gim, Yang Soo;Cha, Seok Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: In this study, we analyzed how the dose change by field size effects on atomic number of shielding materials while using 6 MeV election beam. Materials and Methods: The parallel plate chamber is mounted in $25{\times}25cm^2$ the phantom such that the entrance window of the detector is flush with the phantom surface. phantom was covered laterally with aluminum, copper and lead which thickness have 5% of allowable transmission and then the doses were measured in field size $6{\times}6$, $10{\times}10$ and $20{\times}20cm^2$ respectively. 100 cGy was irradiated using 6 MeV electron beam and SSD (Source Surface Distance) was 100 cm with $10{\times}10cm^2$ field size. To calculate the photon flux, electron flux and Energy deposition produced after pass materals respectively, MCNPX code was used. Results: The results according to the various shielding materials which have 5% of allowable transmission are as in the following. Thickness change rate with field size of $6{\times}6cm^2$ and $20{\times}20cm^2$ that compared to the field size of $10{\times}10cm^2$ found to be +0.06% and -0.06% with aluminum, +0.13% and -0.1% with copper, -1.53% and +1.92% with lead respectively. Compare to the field size $10{\times}10cm^2$, energy deposition for $6{\times}6cm^2$ and $20{\times}20cm^2$ had -4.3% and +4.85% respectively without shielding material. With aluminum it had -0.87% and +6.93% respectively and with lead it had -4.16% and +5.57% respectively. When it comes to photon flux with $6{\times}6cm^2$ and $20{\times}20cm^2$ of field sizes the chance -8.95% and +15.92% without shielding material respectively, with aluminum the number -15.56% and +16.06% respectively and with copper the chance -12.27% and +15.53% respectively, with lead the number +12.36% and -19.81% respectively. In case of electron flux in the same condition, the number -3.92% and +4.55% respectively without shielding material respectively, with aluminum the number +0.59% and +6.87% respectively, with copper the number -1.59% and +3.86% respectively, with lead the chance -5.15% and +4.00% respectively. Conclusion: In this study, we found that the required thickness of the shielding materials got thinner with low atomic number substance as the irradiation field is increasing. On the other hand, with high atomic number substance the required thickness had increased. In addition, bremsstrahlung radiation have an influence on low atomic number materials and high atomic number materials are effected by scattered electrons.

  • PDF

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF