• Title/Summary/Keyword: 모터-발전기

Search Result 57, Processing Time 0.038 seconds

Design of High Efficiency Permanent Magnet Synchronous Generator for Application of Waste Heat Generation ORC System (폐열발전 ORC 시스템 적용을 위한 고효율 영구자석형 동기발전기 설계)

  • Yeong-Jung Kim;Seung-Jin Yang;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2023
  • The power generation method using expensive diesel has operation problems such as high cost diesel generator and a lack of reserved power due to increase of power demand in some islands, requiring expansion of power generation facilities. To solve this problems, it is necessary to improve the efficiency of power generation facilities through an ORC(Organic Rankin Cycle) system application that uses waste heat as a heat source. Therefore, localized application technology of price competitive and highly reliable ORC power generation system is needed, and optimization technology of generators is having great effect, so this study performed two generator designs to get a high-efficiency generator with an optimized 30kW output. The comparison of simulation data for two designed models showed that a generator with SPM factor of 46.2% had an efficiency of 92.1% and a power ouput of about 23.2kW based on 12,000rpm, a generator with SPM factor of 44.46%, had a power output of 27.9kW and efficiency of 93.6% based on above rpm. For the verification of improved design model with SPM factor of 44.46%, the prototype test system with 110kW motor dynamometer was installed and got to the efficiency of 92.08% with conditions of the rated capacity 25kW at 12,000rpm, the test results of prototype generator showed the validity of generator design.

The Performance Evaluation and the Optimal Design of 2MW DFIG (2MW급 DFIG 최적 설계 및 성능 평가에 관한 연구)

  • Cho, Sung-Ho;Oh, Young-Jin;Moon, Byeong-Sun;Lee, Seung-Kuh
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.382-385
    • /
    • 2007
  • The optimal design and characteristic analysis of Double Fed Induction Generator(DFIG) was performed. The purpose of the paper is to verify the accuracy of design and the reliability of DFIG by experiment. A grid connection experiment is performed to confirm generating performance in wide operating range. In this experiment, 2.7MW M/G set is used. The finite element method is applied to calculate parameters and characteristic analysis of DFIG. And in order to reduce design time and efforts, Design of Experiment(DOE) is used. The experimental results are compared with the optimum design results.

  • PDF

The Development of the Turbo Generator System with Direct Driving High Speed Generator (고속 발전기 직접 구동 방식의 터보 제너레이터 시스템 개발)

  • 노민식;박승엽
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.6
    • /
    • pp.87-94
    • /
    • 2003
  • This paper presents results of the development of the turbo generator system with structure which is HSG(High Speed Generator) installed directly to gas-turbine engine. Turbo generator with a high speed motor-generator directly has many advantages aspects of weight, size, lubrication system and complexity of the system compared of conventional turbo generator system with a gear box. But because of direct high speed operation of the high speed generator, we have to need stable high speed motor driving algorithm for perfect engine ignition when engine start. Also we have to need the design of the Power conditioning unit(PCU) for converting high speed AC output power to conventional AC power or needed DC power.

Development and Performance Test of Hydraulic PTO for 50㎾ Class Rotating Body Type Wave Energy Converter (50㎾급 동체회전형 파력발전시스템 유압식 전력변환장치 개발 및 성능시험)

  • Choi, Kyung-Shik;Yang, Dong-Soon;Park, Shin-Yeol;Cho, Byung-Hak
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.99-106
    • /
    • 2011
  • 50kW급 동체회전형 파력발전시스템(WEC;wave energy converter)의 전력변환장치(PTO; power take-off)를 설계 제작한 후 성능시험을 하였다. 파력발전시스템은 2개의 실린더형 동체가 회전관절로 연결된 구조로 수면의 반정도 잠기는 구조로 되어있다. 파랑에 의해 유도된 회전관전의 움직임이 유압실린더에 힘을 가해주며, 유압실린더는 고압의 작동유를 축압기를 경유하여 발전기에 체결된 유압모터로 공급한다. 유압식 PTO은 유압실린더가 왕복운동하는 움직임을 이용하여 고품질의 전력을 생산하는데 효과전인 수단을 제공한다. 파력발전시스템의 경제성은 PTO의 에너지 변환 효율에 크게 의존한다. 발전기를 AC 380V 전력계통에 연계시킨 후, 발전기에서 나오는 출력이 5, 20, 35, 43kW 일때 PTO 전체와 개별기기에 대한 효율을 측정하였다. 본 논문에서 유압식 PTO시스템의 설계에 대해 설명하였으며 효율 향상에 초점을 맞추어 PTO 성능대해 분석하였다.

Development of Real-time based Hardware-In-Loop Simulator for performance evaluation of wind turbine control system (풍력발전기 제어시스템 성능평가를 위한 실시간 처리 기반의 Hardware-In-Loop 시뮬레이터 개발)

  • Kim, Dae-Jin;Ryu, Kyung-Sang;Kim, Byungki;Jang, Moon-Seok;Ko, Hee-Sang;Yoo, Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.794-805
    • /
    • 2017
  • This paper proposes a Hardware-In-Loop(HIL) Simulator for a Wind Turbine and an operational control algorithm to evaluate the performance of a wind turbine control system. It provides not only for the validation of the control logics, safety functions and H/W failure, but also for the high reliability of the wind turbines (by reducing/and the reduction of the operating expense(OPEX) through performance evaluation tests with complex scenarios. On the other hand, the proposed simulator uses MATLAB, CODER, and the PLC library to operate in synchronization with the hardware, and a real-time processing-based wind turbine module including a dynamic model and control system, wind module, grid module and host PC to manage the HIL-simulator. Several experiments were carried out under the above concept to verify the effectiveness of the proposed WT HIL-simulator.

Development of An Active Magnetic Bearing-based Motor-Generator System (자기베어링 지지 모터-발전기 시스템 개발)

  • Kim, Jong-Moon;Kim, Choon-Kyung;Kim, Kook-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.127-129
    • /
    • 1997
  • In this paper, an active magnetic bearing-based motor-generator(M-G) system is designed and controlled by using DSP devices. Several experiments including start-up test, impulse test, whirl test, and generator load test are conducted using digital PID algorithm and AC power of about 58Hz, 100V, 0.8A can be generated from the M-G set.

  • PDF

업계탐방 - 발레오전장시스템스코리아(주) 경주공장

  • Oh, Jeong-Gyu
    • 방재와보험
    • /
    • s.131
    • /
    • pp.52-53
    • /
    • 2009
  • 이번 탐방은 천년고도(古都) 경북 경주시에 위치한 자동차부품 생산공장일 발레오전장시스템스코리(주)를 방문하였다. 승용차와 상용차로 구분된 공장을 대지면적 $101,606m^2$, 건물 연면적 $65,038m^2$규모에 자동차용 발전기, 시동모터, 디스트리뷰터 등을 생산하고 있다. 지난 1999년 프랑스의 세계적인 자동차 전장시스템회사인 발레오에 합병된 이후 현대, 기아, GM대우, 르노 삼성, 쌍용 등에 각종 자동차 전장시스템을 납품하고 있다.

  • PDF

전기 기계류의 소음 측정 및 평가

  • 정완섭;은희준
    • 전기의세계
    • /
    • v.44 no.10
    • /
    • pp.47-54
    • /
    • 1995
  • 본 논문은 ISO 관련 소음 측정 표준안(1995년 8월 기준)들에 포함된 기본적 측정량들의 정의, 그들의 측정 및 분석 방법의 간략한 소개와 더불어 이들 규격의 활용 방안을 예시한다. 제 2절에서 소음 측정관련 기본 양들의 정의와 전문 용어들을 간략히 소개한다. 이러한 측정치를 이용하여 우리 주위에서 가장 가까이 있는 컴퓨터의 소음 측정 및 평가 방안을 제 3장에서 토의 한다. 그리고, 전기 기기류의 대표적 소음원이며 산업의 동력원인 모터 및 발전기의 소음 측정 및 특성 평가방안을 검토한다. 끝으로, 우리 산업계와 소음 관련 업무의 향후 나아갈 길을 제 5장에서 요약한다.

  • PDF

Journal Bearing Design Retrofit for Process Large Motor-Generator - Part II : Rotordynamics Analysis (프로세스 대형 모터-발전기의 저어널 베어링 설계 개선 - Part II : 로터다이나믹스 해석)

  • Lee, An Sung
    • Tribology and Lubricants
    • /
    • v.28 no.6
    • /
    • pp.265-271
    • /
    • 2012
  • In the preceding Part I study, for improving the unbalance response vibration of a large PRT motor-generator rotor fundamentally by design, a series of design analyses were carried out for bearing improvement by retrofitting from original plain partial journal bearings, applied for operation at a rated speed of 1,800 rpm, to final tilting pad journal bearings. To satisfy evenly key basic lubrication performances such as the minimum lift-off speed and maximum oil-film temperature, a design solution of 5-pad tilting pad journal bearings and maximizing the direct stiffness by about two times has been achieved. In this Part II study, a detailed rotordynamic analysis of the large PRT motor-generator rotor-bearing system will be performed, applying both the original plain partial journal bearings and the retrofitted tilting pad journal bearings, to confirm the effect of rotordynamic vibration improvement after retrofitting. The results show that the rotor unbalance response vibrations with the tilting pad journal bearings are greatly reduced by as much as about one ninth of those with the plain partial journal bearings. In addition, for the tilting pad journal bearings there exist no critical speed up to the rated speed and just one instance of a concerned critical speed around the rated speed, whereas for the plain partial journal bearings there exist one instance of a critical speed up to the rated speed and two instances of concerned critical speeds around the rated speed.

The Study on Operability Improvement of the start motor for Auxiliary Power Unit of Rotorcraft (회전익 항공기 보조동력장치 시동모터 운용성 개선연구)

  • Lee, Gwang-Eun;Kang, Byoung-Soo;Na, Seong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.774-780
    • /
    • 2021
  • The auxiliary power unit (APU) of a rotorcraft starts the engine during operation/flying. The APU is composed of a gas turbine engine type. The starting principle of the component is that the electric start motor generates the power required for starting by rotating the shaft. In this study, quality improvement was performed by applying an over-running clutch (ORC) between the APU and the starter motor to secure the operability of the starter motor of the APU mounted on the rotorcraft. The starter motor has the main role of starting the APU, but during operation, it is rotated without load by the rotational force of the APU gear shaft, resulting in friction at the brush. This phenomenon causes abrasion of the brush of the starter motor. Consequently, when the APU operation time increases, the brush life decreases, and the operability of the APU is affected. In this study, an ORC that separates the interlocking between the start motor brush abrasion and the APU operation time was applied to improve the operability/durability of the APU starter motor. The effect was verified through a test, and the technical feasibility of the design change was analyzed.