• Title/Summary/Keyword: 모터 댐퍼

Search Result 14, Processing Time 0.032 seconds

Vibration Control of Steel-Frame Structures by a Linear Motor Damper (선형 모터 댐퍼를 이용한 철골 구조물의 진동제어)

  • 문석준;정태영;임채욱;정정교;박진일;김두훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.49-58
    • /
    • 2003
  • The linear motor has not only no backlash and less friction, resulting in very high accuracy, but also mechanical simplicity, higher reliability, and longer lifetime. In this study, a large-capacity hybrid mass damper using linear motor principle has been developed to suppress vibration of large structures. It is designated linear motor damper in this paper. The LMD has been designed to be able to move the auxiliary damper mass of 155kg up to $\pm$250mm stroke. A series of performance tests for LMD control system with $H_{winfty}$ robust controller have been carried out on the full-scale steel frame structure. Through the performance tests, it is confirmed that vibration response levels are reduced down 10dB for the first and second modes of the test structure.

Linear Motor Damper for Vibration Control of Flexible Structure (유연 구조물의 진동제어를 위한 선형모터댐퍼)

  • Sim Sangdeok;Kang Hoshik;Song Ohseop;Kim Youngchan;Kim Doohoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.492-498
    • /
    • 2005
  • A linear motor damper based on the linear motor principle is developed to suppress structural vibration. This paper deals with the design, analysis, and manufacture of the linear motor damper. It is designed to be able to move the auxiliary mass of 1500kg, up to $\pm250mm$ stroke. The control algorithm was designed based on LQG control logic with acceleration feedback. Through performance tests, it was confirmed that the developed hybrid mass damper has reliable feasibility as a control device for structural control. In addition, the linear motor damper is more economical than both hydraulic and electric motor driving mass damper with respect to simple structure and low maintenance cost. A series of performance tests of the linear motor damper system were carried out on the full-scale steel frame structure in UNISON Corporation. Through the performance tests, it was confirmed that acceleration levels are reduced down 10dB for first mode of structure

Study on the control of VCM and its application to the vibration isolator (VCM의 제어 및 제진 장치 응용에 관한 연구)

  • Kim, Jin-Man;Nam, Taek-Kun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • The degradation of durability and increase of fatigue on the ship are mainly caused by vibration of the engine and rotating machineries. The damper to minimize the influence from vibration is usually attached between the machineries and its base. General damper applied on the vessel is passive damper which is designed to attenuate specified frequency signals, i.e, high frequency vibration signals. But it is hard to anticipate its performance for low frequency signals. In this research, active vibration isolator using VCM is developed to suppress wide band vibration signals. Routh-Huritz's stable condition, ultimate sensitivity method and parameter tuning are applied to derive PID parameters and 2 and 4 phase choppers are also adapted to drive VCM. Simulation and experiments are executed to confirm the effectiveness of the proposed control schemes.

Modeling of Non-linear and Analysis of Dynamic Characteristics of Linear Compressor (Linear Compressor의 비선형 모델링 및 동특성 해석)

  • Park, Dae-Geun;Jang, Jin-Hak;Kim, Sung-An;Kim, Kwang-Hee;Lee, Sang-Gun;Choi, Da-Wun;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.920-921
    • /
    • 2011
  • 본 연구는 비선형을 고려한 Linear Compressor의 스토로크의 동특성 해석 방법을 제안하고, 시작기에 대해서 특성실험 결과와 비교, 검토하였다. 비선형 특성으로 가스힘을 스트로크 및 전류에 대한 함수인 스프링 과 댐퍼로, 인덕턴스와 모터상수를 스트로크 및 전류에 대한 쇄교자속의 함수로 수식적 모델링 하였다. 이 관계식을 통해 동작특성을 해석하였다.

  • PDF

Vibration Control of Real-Size Steel Structure by Hybrid Linear Motor Damper (혼합형 리니어 모터 댐퍼를 이용한 실규모 철골 구조물의 진동제어)

  • 정정교;김두훈;박해동;박진일;정태영;문석준;임채욱
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.740-745
    • /
    • 2002
  • To control vibration of real-size steel structure, a hybrid-type linear motor damper was designed and applied to 30m steel structure at UNISON. The LMD was tuned to the first mode natural frequency of the building. In order to use for simulation data and control parameters, dynamic response characteristics of building and damper were tested. The response of building was reduced by 10 dB with LMD and H$\infty$ algorithm. This value was similar to the result of simulation.

  • PDF

Dynamic Analysis of the Valves installed in the swash plate type of Hydraulic Driving Motor (사판식 구동 모터에 장착된 밸브의 동적거동 해석)

  • Noh, D.K.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.62-69
    • /
    • 2012
  • Recently, hydraulic motor is getting the spotlight. It is resulted from rapid civil engineering public works by a lot of developing countries around the world. In this study, we divided the valves which are affixed in the hydraulic motor into some parts, implemented them through computer simulation, verified validation of each component, and analyzed behavior adding driving condition. Through the analyzed results with general driving condition, we found the reason why behavior became unstable as the motor had started spinning. Through the analyzed results with tough driving condition, we verified that the valve works well with it's production purpose.

Transient-Sub transient Characteristic Modeling of Synchronous Generator using MATLAB-SIMULINK (MATLAB-SIMULINK를 이용한 동기발전기 과도-차과도 특성 모델링)

  • Lee, Gang;Jo, Jongmin;Kim, Jichan;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.164-165
    • /
    • 2019
  • 본 논문은 3상 동기발전기의 과도 특성을 분석하기 위해 MATLAB/ SIMULINK를 이용하여 모델링하였으며 동기발전기 출력단의 개방 및 3상 단락 회로 조건에 따른 특성곡선을 분석하였다. 정상상태, 과도상태 및 차과도상태 구간에서 고정자 권선, 회전자 권선 및 댐퍼 권선 등이 갖는 자기 인덕턴스 및 상호 인덕턴스 특성 관계와 자속 변화특성 등을 수학적 모델 기반의 소신호 모델링을 통해 3상 동기발전기를 등가적으로 모델링하였다. 시뮬레이션을 통해 얻은 값에 의해 과도상태와 차과도상태의 모터 데이터를 분석하고 단락상태의 시간 상수를 계산하여, 동기발전기의 3상 단락 조건에서 초기 과도 및 과도상태의 특성을 검증하였다.최종적으로, 이론적 공식에 의해 계산 된 동기 발전기의 파라미터는 시뮬레이션 결과와 일치하며 오차는 2 % 범위 내에 있다.

  • PDF

Development of a Large Capacity Hybrid-type Linear Motor Damper for the Vibration Control of Building Structures (건축 구조물 제진용 대용량 하이브리드형 리니어 모터 댐퍼의 개발)

  • 정태영;임채욱;허영철;장석명;정상섭;김두훈;박해동
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.951-957
    • /
    • 2001
  • A large capacity hybrid-type linear motor damper was designed and fabricated for the application to the vibration control of a large building structure model. It has been designed to be able to move the damper mass, 1,500kg up to $\pm$ 250mm strokes at the first mode natural frequency of the building structure model, 0.51Hz. Dynamic response characteristics of the fabricated damper were investigated by experimentally and analytically.

  • PDF

Development of Integrated drone measurement system for Flood discharge measurement (홍수기 유량측정을 위한 통합 드론측정시스템 개발)

  • Tae Hee Lee;Jong Wan Kang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.82-82
    • /
    • 2023
  • 홍수기 하천에서 유량측정은 예산, 인력, 안전 및 측정 시 편의성 등의 이유로 측정에 제한이 많다. 특히, 태풍 등으로 인한 호우사상 발생 시 위와 같은 문제로 홍수량 측정에 어려움이 따른다. 이러한 문제점을 개선하기 위해 Lee et al.(2021)은 드론과 전자파표면유속계의 기능을 융합한 DSVM(Dron and Surface Veloctity Meter using doppler radar) 측정방법을 개발하였다. 전자파표면유속계 측정의 제한 요소인 진동을 감소시키기 위해 댐퍼플레이트를 개발하였고 금강의 지류인 봉황천에 현장 적용을 통해 DSVM 측정방법의 실용성을 확인하였다. 기존 연구에서 DSVM 방법은 드론의 각 측선 이동을 위한 조종과 전자파표면유속계 측정의 제어를 측정자가 수행하였는데 본 연구에서는 통합 드론측정시스템(IDMS, Integrated Drone Measurement System) 개발을 통해 측정자의 조종 의존도를 줄임과 동시에 안전하고 정확한 유량측정을 위해 노력하였다. 기존 댐퍼플레이트의 상하 진동 흡수 기능뿐만 아니라 전자파표면유속계의 흔들림 현상 등 자세 제어 기능을 보완하기 3축 모터를 적용한 방수짐벌을 개발하여 측정 정확도를 향상시켰다. 미션컴퓨터 개발로 측정지점의 측정 임무정보를 DB화하여 각 측선별 헤딩, 고도, 이동 등 자동항법 기능과 기체의 안정화 이후 전자파표면유속계를 자동으로 제어하여 측정을 실시하는 기능을 구현하였다. 또한 통합 GCS(Ground Control System)를 통해 비행 및 측정에 대한 모든 정보를 확인하고 컨트롤 할 수 있게 하였다. 2022년 금산군(제원대교), 무주군(취수장), 경주시(서천교) 지점에서 홍수기 유량측정에 도입하여 중간단면적법, 지표유속법을 적용하여 통합드론측정시스템의 실용성을 검증 완료하였다. 2023년 현장에 18대의 통합 드론측정시스템을 도입하여 홍수기 유량측정에 활용할 계획이다.

  • PDF