• Title/Summary/Keyword: 모의치료

Search Result 327, Processing Time 0.032 seconds

Radiation Dose Calculation using MIRD TYPE PHANTOM in the Surrounding Organs during Brachytherapy of Breast Cancer (유방암의 근접치료 시 수학적 모의피폭체를 이용한 인접장기의 선량평가)

  • Park, Eun-tae;Kim, Jung-hoon;Im, In-chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.271-278
    • /
    • 2016
  • This study was fulfilled to evaluate the absorbed dose of breast and adjacent organs using MIRD type phantom in brachytherapy of breast cancer. The absorbed dose was analyzed assuming left or right breast is source organ which is $^{103}Pd$ or $^{192}Ir$. As a result, $^{192}Ir$ dose is higher than $^{103}Pd$ in source organ and also in contralateral breast. Particularly, significant adjacent organs are lung, liver, heart and contralateral breast in brachytherapy of breast cancer.

Bedside Teaching of Relaxation Technique for Terminal Cancer Patients Treated with Radiation Therapy (방사선치료를 받는 말기암환자들을 대상으로 한 이완요법)

  • Kim, Sang-Won;Chun, Mison;Kim, Hyo Shin
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.3
    • /
    • pp.256-261
    • /
    • 2016
  • Radiation therapy is an effective modality to alleviate cancer-related symptoms. To deliver radiation accurately, it is essential to secure stability of the treatment position in patients during each treatment time. However, some patients could be less cooperative due to their psychoemotional issues. We present two cases of terminal-stage cancer patients who were initially unable to lie still on the treatment table before simulation. A relaxation technique was taught to them on the bed, and they could relax and undergo radiation therapy with effective symptom relief.

The Effect of Low Level Laser Therapy on Pressure Pain Threshold in Patients with Temporomandibular Disorders : A Double-blind Study (저출력레이저 조사가 측두하악장애환자의 압력통각역치에 미치는 영향)

  • Cho, Kyung-Ah;Park, June-Sang;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.3
    • /
    • pp.281-300
    • /
    • 1999
  • 측두하악장애환자와 정상대조군의 두경부 근육에 있어서 실제 또는 위약 치료에 따른 저출력 레이저의 효과와 측두하악장애환자에서 저출력 레이저의 효과적인 치료기간을 평가하기 위하여, 측두하악장애를 가진 부산대학교 치과대학생 19명과 측두하악장애의 병력이나 증상이 없는 부산대학교 치과대학생 20명을 대상으로 치료전, 치료 2주 및 치료 4주에 구외촉진이 가능한 32 근골격 촉진점의 압력통각역치와 각각의 동통정도와 두개하악지수를 측정하여 다음과 갈은 결론을 얻었다, 1. 치료전 환자군의 압력통각역치는 정상대조군 압력통각역치보다 낮았다(p<0.05), 2. 환자군의 압력통각역치는 유의하게 증가하였으며 (p<0.05) 레이저 조사 환자군의 증가된 압력통각역치는 레이저 모의조사-환자군의 증가된 압력통각역치보다 더 크게 나타났다. 3. 대조군에서는 레이저 조사나 모의 조사에 의해 압력통각역치와 변화가 없었다. 4. 레이저 조사-환자군의 압력통각역치가 안면근육에서는 치료2주부터 유의하게 증가하였고 경부근육에서는 치료4주부터 유의하게 증가하였다(p<0.05) 5. 레이저 조사-환자군에서 동통의 정도와 두개하악지수는 유의하게 감소하였다(p<0.05).

  • PDF

즉발감마선을 이용한 70MeV 양성자선량 급락지점 위치 측정에 관한 연구

  • Seo, Gyu-Seok;Kim, Jong-Won;Kim, Ju-Yeong;Min, Cheol-Hui;Jo, Seong-Gu;Kim, Chan-Hyeong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.100-102
    • /
    • 2005
  • 양성자 빔을 이용한 치료는 종양부위에 높은 선량을 균일하게 전달하고 정상세포에는 적은 선량을 전달할 수 있어 암치료 효과가 높으나 정확한 치료와 환자의 안전을 위해서는 양성자선량의 급락지점을 정확히 아는 것이 중요하다. 본 연구에서는 양성자와 물질과의 핵반응으로 직각방향으로 방출되는 즉발감마선을 측정하여 양성자선량 급락지점을 측정할 수 있는 검출시스템을 몬테칼로 전산코드로 전산모사하였으며, 70MeV 단일에너지 빔과 최대에너지가 70MeV인 SOBP 빔을 모의피폭체인 물팬텀에 조사하고 검출시스템을 통해 직각방향으로 방출되는 즉발감마선의 분포를 계산하였다. 모의피폭체 안에서의 양성자선량의 분포와 측정된 즉발감마선의 분포를 서로 비교하여 두 분포 사이의 상관관계를 찾고 이 상관관계를 이용하여 양성자선량 급락지점을 결정할 수 있음을 확인할 수 있었다.

  • PDF

Study of Failure Mode and Effect Analysis in Brachytherapy (근접방사선치료에 관한 사고유형과 영향분석 연구)

  • Lee, Soon Sung;Park, Dong Wook;Shin, Dong Oh;Kim, Dong Wook;Kim, Kum Bae;Oh, Yoon-Jin;Kim, Juhye;Kwon, Na Hye;Kim, Kyeong Min;Choi, Sang Hyoun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.627-635
    • /
    • 2017
  • Brachytherapy is generally performed in conjunction with external radiation therapy, and the treatment course is very complicated, which can lead to radiation accidents. In order to solve this problem, we designed the process map by applying the failure mode and effects analysis (FMEA) method to the Brachytherapy and scored the risk priority number (RPN) for each treatment course based on this process map. The process map consisted of five steps, Patient consulting", "Brachytherapy simulation", "CT simulation", "Brachytherapy treatment planning" and "Treatment". In order to calculate the RPN, doctor, medical physicist, dose planners, therapist, and nurse participated in the study and evaluated occurrence, severity, and lack of detectability at each detail step. Overall, the process map is preceded by a patient identification procedure at each treatment stage, which can be mistaken for another patient, and a different treatment plan may be established to cause a radiation accident. As a result of evaluating the RPN for the detailed steps based on the process map, overall "Patient consulting" and "Brachytherapy treatment planning" step were evaluated as high risk. The nurses showed a tendency to be different from each other, and the nurses had a risk of 55 points or more for all the procedures except "Treatment", and the "Brachytherapy simulation" step was the highest with 88.8 points. Since the treatment stage differs somewhat for each medical institution performing radiotherapy, it is thought that the risk management should be performed intensively by preparing the process map for each institution and calculating the risk RPN.

Development of a Verification Tool in Radiation Treatment Setup (방사선치료 시 환자자세 확인을 위한 영상 분석 도구의 개발)

  • 조병철;강세권;한승희;박희철;박석원;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • In 3-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), many studies on reducing setup error have been conducted in order to focus the irradiation on the tumors while sparing normal tissues as much as possible. As one of these efforts, we developed an image enhancement and registration tool for simulators and portal images that analyze setup errors in a quantitative manner. For setup verification, we used simulator (films and EC-L films (Kodak, USA) as portal images. In addition, digital-captured images during simulation, and digitally-reconstructed radiographs (DRR) can be used as reference images in the software, which is coded using IDL5.4 (Research Systems Inc., USA). To improve the poor contrast of portal images, histogram-equalization, and adaptive histogram equalization, CLAHE (contrast limited adaptive histogram equalization) was implemented in the software. For image registration between simulator and portal images, contours drawn on the simulator image were transferred into the portal image, and then aligned onto the same anatomical structures on the portal image. In conclusion, applying CLAHE considerably improved the contrast of portal images and also enabled the analysis of setup errors in a quantitative manner.

  • PDF

Head & neck 환자의 방사선치료 시 tongue displacer 사용의 유용성 평가

  • 박용철;박영환;김경태;최지민
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2002
  • I. 목적 : 방사선 치료 시 최적화된 체내 선량분포를 얻는 것은 정상조직의 장애를 줄이고 종양선량을 높여 치료 효율을 극대화하는데 매우 중요하다. 본원에서는 병변 부위가 한쪽으로 치우친 head&neck 환자 치료 시 정상조직(tongue)을 보호하기 위해 tongue displacer를 만들어 사용한다. 이에 본 저자는 tongue displacer사용의 치료 유용성을 평가 하고자 한다. II. 대상 및 방법 : head & neck 치료 환자 중 병변 부위가 인체의 정중선(MSP)을 기준으로 한쪽으로 치우친 환자를 대상으로 하였다. 사용된 실험재료로는 C-T (high speed advantage, GE,US), RTP System (3D RTP system, prowess, US), 치과용 인상제 주입기(caulk system, quixx, japan), tongue displacer 등이 있다. 실험 방법은 모의 치료나 planning C-T를 시행하기 전에 치료 환자에게 사용할 개인용 tongue displacer를 치과용 인상제로 자체 제작하였다. 제작 후 모의 치료를 시행하고 3D plan을 하기 위해 planning C-T를 촬영하게 되는데 이때 tongue displacer사용 유. 무에 따라 각각 촬영을 하였다. 촬영된 두 가지의 CT영상을 prowess를 이용하여 3D plan을 하게 되는데 이때의 plan parameter나 beam direction등 plan에서의 모든 조건은 모두 동일시하고 선량 분포 및 DVH(dose volume histogram)값을 비교하였다. III. 결과 : tongue displace의 사용 유. 무에 따른 3D plan상의 DVH 비교 결과 tumor volume 주위의 다른 organ들은 모두 비슷한 양상의 DVH를 보였으나 tongue에 있어서 큰 변화를 보였다. tongue displacer를 사용 시, 미 사용시 보다 tongue의 위치를 변화시켜 치료 부위 외의 tongue에 받는 방사선 피폭 면적을 줄일 수 있었고 그 결과 DVH상의 $50\%$ volume이 $16\%$ 정도 줄어드는 것이 확인되었다. IV. 결론 : tongue에 방사선을 조사하면 방사선 부작용으로 mucositis, ulcer, hemorrhage등의 pain(동통)이 수반되므로 치료환자의 음식물 섭취불량으로 체증감소 등 전신 쇠약으로 이어질 수 있다. head & neck 환자 중에서 병소 위치가 한쪽으로 치우쳐서 있을 경우 인상제를 이용하여 tongue displacer를 만들어서 사용하면 tongue 의 위치를 변화시켜 방사선 조사 야에서 제외시켜준다. 그러므로 방사선 치료 시 tongue의 부작용을 최소화 할 수 있고 환자의 방사선 치료 만족도를 높일 수 있다고 사료된다.

  • PDF

Derivation of the Effective Energy Calculation Formula of the X-ray Beam Generated by the CT Simulator (CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식 유도)

  • Kim, Jong-Eon;Lee, Sang-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.869-875
    • /
    • 2021
  • The purpose of this study is to derive a formula for calculating the effective energy of an X-ray beam generated by a CT simulator. Under 90, 120, and 140 kVp X-ray beams, the CT number calibration insert part of the AAPM CT performance phantom was scanned 5 times with a CT simulator. The CT numbers of polyethylene, polystyrene, water, nylon, polycarbonate, and acrylic were measured for each CT slice image. The average value of CT number measured under a single tube voltage and the linear attenuation coefficients corresponding to each photon energy calculated from the data of the National Institute of Standards and Technology were linearly fitted. Among the obtained correlation coefficients, the photon energy having the maximum value was determined as the effective energy. In this way, the effective energy of the X-ray beam generated at each tube voltage was determined. By linearly fitting the determined effective energies(y) and tube voltages(x), y=0.33026x+30.80263 as an effective energy calculation formula was induced.

The Usefulness of Integrated PET/CT Simulator for Non-Small Cell Lung Cancer Using the F-18 Fluoro-2-deoxyglucose (FDG) (포도당 유도체 불소화합물(FDG)을 이용한 비소세포폐암의 Integrated PET/CT 전산화 모의치료기에 대한 유용성 평가)

  • Na, Jong Eok;Suh, Jeong Nam;Kim, Jin Soo;Kim, Dae Seob;Hong, Dong Ki;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Purpose: To evaluate the usefulness of Integrated PET/CT and compare the gloss tumor volume (GTV) identified on CT, PET, PET/CT to that obtained from fluorodeoxyglucose (FDG). Materials and Methods: This experimental study was obtained using GE Discovery 690 (General Electric Healthcare, Milwaukee, MI, USA) PET/CT simulator with Gammex Laser System for five non-small cell lung cancer (NSCLC) patients. In order to increase the reproducibility of the patient setup, We have to fixed to patients using the Extended Wing Board. GTV delineation was painted using the EclipseTM ver.10 contouring program for CT, PET, PET/CT images. And then, We were to compare the changes in the GTV. Results: These results are drawn from 5 patients who have atelectasis or pneumonitis. Compared to CT defined GTV, PET was decreased by 10.5%, 11.8% and increased by 67.9%, 220%, 19.4%. PET/CT was decreased by 7.7%, 6.7%, 28% and increased by 232%, 24%. Conclusion: We were able to determine the usefulness of PET/CT simulator for NSCLC. PET/CT simulator in radiation therapy is useful to define the target volume and It is possible to delineate Objective and accurate target volume. It seems to be applicable to other areas in the near future.

  • PDF

Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy (자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가)

  • Lee, Yun-Jong;Nho, Young-Chang;Lee, Jai-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.4
    • /
    • pp.387-391
    • /
    • 2006
  • Computational and experimental dosimetry of Henschke applicator with respect to high dose rate brachytherapy using the MIRD phantom and a remote control afterloader were performed. A comparison of computational dosimetry was made between the simulated Monte Carlo dosimetry and GAMMADOT brachytherapy Planning system's dosimetry. Dose measurements was performed using ion chamber in a water phantom. Dose rates are calculated using Monte Carlo code MCNP4B and the GAMMADOT. Thecomputational models include the detailed geometry of Ir-192 source, tandem tube, and shielded ovoids for accurate estimation. And transit dose delivered during source extension to and retraction from a given dwell position was estimated by Monte Carlo simulations. Point doses at ICRU bladder/rectal pointswhich have been recommened by ICRU 38 was assessed. Calculated and measured dose distribution data agreed within 4% each other. The shielding effect of ovoids leads to 19% and 20% dose reduction at bladder surface and rectal points.