• Title/Summary/Keyword: 모의치료기

Search Result 80, Processing Time 0.038 seconds

Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients (사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰)

  • Ahn, Seung-Kwon;Kim, Yong-Bae;Lee, Ik-Jae;Song, Tae-Soo;Son, Dong-Min;Jang, Yung-Jae;Cho, Jung-Hee;Kim, Joo-Ho;Kim, Dong-Wook;Cho, Jae-Ho;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.189-194
    • /
    • 2008
  • Purpose: We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by $4{\sim}4.4%$ to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the therapy owing to the reduction of the air gap using a vacuum pump and a vacuum valve. This set-up represents a promising alternative device for delivering a homogenous dose to the target volume.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

Carbon Fiber as Material for Radiation Fixation on Device : A comparative study with acrylic (고정기구 재질로써 탄소 섬유와 아크릴의 방사선량 감쇄 영향 비교)

  • Chie, Eui-Kyu;Park, Jang-Pil;Huh, Soon-Nyung;Hong, Se-Mie;Park, Suk-Won;Kim, In-Ah;Wu, Hong-Gyun;Kim, Jae-Sung;Kang, Wee-Saing;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Radiation absorption parameters of carbon fiber panel were measured in comparison to acrylic panel. $30{\times}30cm$ sized 2mm thick carbon fiber panel and identical sized 6mm thick acrylic panel were placed in tray holder position and 0cm, 5cm, 10cm from surface of phantom. Radiation field size was $10{\times}10cm$. 50MU of 4MV photon was irradiated to the phantom with dose rate of 300MU/min. Source-to-phantom distance was 120cm. Radiation dose was measured with 0.6cc Farmer-type ionization chamber with 1cm build-up. Measurement was repeated thrice and normalization was done to the dose of the open field. Radiation transmission rate of carbon fiber panel is approximately 1% lower than acrylic panel of equivalent thickness. However, considering the strength of the material, transmission rate is higher for carbon fiber panel. Although carbon fiber panel increases the radiation dose when attached to the surface for about 2%, it normalizes the radiation dose to 97-99% of irradiated dose which could have been lowered to as much as 5-7.5% with acrylic panel. As carbon fiber panel is stronger than acrylic panel, radiation fixation device could be made thinner and thus lighter and furthermore, with increased radiation transmission. This in turn makes carbon fiber more ideal material for radiation fixation device over conventionally used acrylic.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

The inhibitory effect of swimming exercise on inflammation in adipose tissue of obese mice after ovariectomy (수영 운동이 난소절제 후 비만 쥐의 지방조직에서 염증에 미치는 억제 효과)

  • Jeong, Sun-Hyo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1125-1137
    • /
    • 2020
  • This study investigated whether swimming exercise suppresses(: inhibites) the inflammatory response in adipose tissue in obese mice induced by a high fat diet after ovariectomy in female mice. Experimental group and control group were divided into sham-opereated group (Sham), ovariectomized group (OVX), and ovariectomized group with swimming exercise (OVX/Ex). All female mice fed high fat diet (45% fat) for 8 weeks. Compared with the Sham, the OVX increased the weight of visceral adipose tissue including parametrial, retroperitoneal, and mesenteric adipose tissue. Compared to the OVX, the OVX/Ex demonstrated reductions the weight of visceral adipose tissue. Compared to the Sham, the OVX decreased the mRNA expression of IκBα and increased the mRNA expression of inflammatory cytokines (L-6, MCP-1, TNF-α and leptin) in adipose tissue. But the OVX/Ex appeared to increase the mRNA expression of IκBα and decrease the mRNA expression of inflammatory cytokines in adipose tissue, compared with the OVX. This findings suggested that swimming exercise is useful for preventing adipose tissue inflammation, which will be effective in the prevention and treatment of obesity in obese mice induced obesity by a high fat diet after ovariectomy.

A Cephalometric Study on factors affecting the FHI (Facial Height Index) in Angle's Class II division 1 malocclusion Patients (한국인 2급 1류 부정교합자의FHI(Facial Height Index)에 영향을 미치는 요소에 관한 두부방사선 계측학적 연구)

  • Park, Young-il;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.401-413
    • /
    • 1996
  • Facial vertical dyscrepancies is decided on the relationship between the anterior vertical facial height and posterior vertical facial height. Thus this study was conducted to determine the factors that affect the FHI, and classify the Class II div.1, malocclusion, which success is dependent on the vertical control according to the FHI, which is the ratio of antero-inferior facial height, posterio-inferior facial height ratio, and to use this as a guideline for treatment. Angle between palatal plane and Mandibular plane were in the order of RH, ID. Thus showing that interrelated angle was more inportant than the independent angle of both, palatal plane and Mandibular plane. The tendency of Cl II div.1. Malocclusion according to FHI, showed the Low group to have Mx. protrusion, prominent development of Mn. ramus, and the Mn. body length and ant. post. position was normal. The Normo group showed slight protrusion of the Maxilla,. The development of the ramus was less than normal and the Mn. was in a slight retruded position. The High group showed the Mx. in a normal position, the development of the Mn. ramus and body was the lowest, and the Mn. was in a posterior position. In observation of the factors affecting the FHI between each groups of Cl II div.l, malocclusion; In the Low group the MP- PP angle was very small, the ID was smililar to the normal group, but the RH was very large thus the FHI was increased. In the Normo group, the PP-MP angle was normal, ID was slightly smaller than the normal group and the RH was slightly smaller than the normal group, thus maintaining a normal FHI ratio. In the High group the PP-MP angle was very large, the ID was similar to the normal group, but the RH was smaller than the normal group thus the FHI was small.

  • PDF

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

Comparison of Play Perception and Play Participation of Parents of Disabled Children and Non-disabled Children in Preschool Age (학령전기 장애 아동 부모와 비장애 아동 부모의 놀이 인식과 놀이 참여 비교 연구)

  • Park, DaSol;Lee, EunYoung;Lee, SunHee;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.9 no.1
    • /
    • pp.69-78
    • /
    • 2020
  • Objective : The purpose of this study was to conduct a comprehensive survey of children's play in parents of disabled and non-disabled children prior to commencing school. This study aimed to further understanding play recognition and to present a specific direction of play necessary to each parent. Methods : A questionnaire based on prior studies was sent to 700 people who had previously agreed to the take part. A total of 596 questionnaires were analyzed. Uncollected and insincere surveys, of which 106 were questionnaires for parents of disabled children, were exclused from analysis. The SPSS Window 23 program was used for data analysis and frequency analysis and the independent sample T test were performed. Results : Disabled children's parents perceived playing with their children as more important than that of non-disabled children's parents(p<0.01). There was no statistical difference between disabled children and non-disabled children's parents, but there were some differences(p=0,053). Both disabled and non-disabled children had more time to participate with their mothers than with their fathers. Mothers with disabilities had more time to play however, fathers with no disabilities had more time. Both disabled and non-disabled children's parents had the most "ordinary" frequency of buying toys and there was very littele difference between the 2 groups. Both disabled and non-disabled children's parents primarily used the internet to acquire play information, and consideration when buying fun was followed by interest inducement, development level and safety. Conclusion : Through this study, it was possible to compare the status of play recognition and participation by parents of children with or without disabilities. Based on this study, parents will be able to find out what they really need to play and will be provided as a basis for future play studies for children.

CLINICAL STUDY OF THE ABUSE IN PSYCHIATRICALLY HOSPITALIZED CHILDREN AND ADOLESCENTS (소아청소년 정신과병동 입원아동의 학대에 대한 임상 연구)

  • Lee, Soo-Kyung;Hong, Kang-E
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.10 no.2
    • /
    • pp.145-157
    • /
    • 1999
  • This study was performed by the children and adolescents who were abused or neglected physically, emotionally that were selected in child & adolescents psychiatric ward. We investigated the number of these case in admitted children & adolescents, and also observed characteristics of symptoms, developmental history, characteristics of abuse style, characteristics of abusers, family dynamics and psychopathology. We hypothesized that all kinds of abuse will influnced to emotional, behavioral problems, developmental courses on victims, interactive effects on family dynamics and psychopathology. That subjects were 22 persons of victims who be determined by clinical observation and clinical note. The results of the study were as follows:1) Demographic characteristics of victims:ratio of sex was 1:6.3(male:female), mean age was $11.1{\pm}2.5$. According to birth order, lst was 12(54.5%), 2nd was 5(23%), 3rd was 2(9%) and only child was 3(13.5%). 2) Characteristics of family:According to socioeconomic status, middle to high class was 3(13.5%), middle one was 9(41.% ), middle to low one was 9(41%), low one was 1(0.5%). according to number of family, under the 3 person was 3(13.5%), 4-5 was 17(77.5%), 6-7 was 2(9%). according to marital status of parents, divorce or seperation were 5(23%), remarriage 2(9%), severe marital discord was 19(86.5%). In father, antisocial behavior was 7(32%), alcohol dependence was 10(45.5%). In mother, alcohol abuse was 5(23%), depression was 17(77.3%), history of psychiatric management was 6(27%). 3) Characteristics of abuse:Physical abuse was 18(81.8%), physical and emotional abuse and neglect were 4(18.2%). according to onset of abuse, before 3 years was 15(54.5%), 3-6 years was 5(27.5%), schooler was 1(15%). Only father offender was 2(19%), only mother offender was 8(35.4%), both offender was 8(35.4%), accompaning with spouse abuse was 7(27%), and accompaning with other sibling abuse was 4(18.2%). 4) General characteristics and developmental history of victims:Unwanted baby was 12(54.5%), developmental delay before abuse was9(41%), comorbid developmental disorder was 15(68%). there were 6(27.5%) who didn‘t show definite sign of developmental delay before abuse. 5) Main diagnosis and comorbid diagnosis:According to main diagnosis, conduct disorder 6(27.3%), borderline child 5(23%), depression4(18%), attention deficit hyperactivity disorder(ADHD) 4(18%), pervasive developmental disorder not otherwise specified 2(9%), selective mutism 1(5%). According to comorbid diagnosis, ADHD, borderline intelligence, mental retardation, learning disorder, developmental language disorder, oppositional defiant disorder, chronic tic disorder, functional enuresis and encoporesis, anxiety disorder, dissociative disorder, personality disorder due to medical condition. 5) Course of treatment:A mean duration of admission was $2.4{\pm}1.5$ months. 11(15%) showed improvement of symtoms, however 11(50%) was not changed of symtoms.

  • PDF