• Title/Summary/Keyword: 모의실험장치

Search Result 380, Processing Time 0.037 seconds

Control of Left Ventricular Assist Device using Neural Network Feedback Feedforward Controller (인공신경망 Feedforward제어기를 이용한 좌심실보조장치의 제어실험)

  • 정성택;류정우;김상현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.150-155
    • /
    • 1997
  • In this paper,we present neural network for control of Left Ventricular Assist Device(LVAD)system with a pneumatically driven mock cirulation system. It is necessary to apply high perfomance control techniques, since the LVAD system represent nonlinear and time-varing characteristics. Fortunately, the neural network can be applied to control of a nonliner dynamic system by learning capability. In this study,we identify the LVAD system with neural network and control the LVAD system by PID controller and neural network feedforward controller. The ability and effectiveness of controlling the LVAD system using the proposed algorithm will be demonstrated by computer simulation and experiment.

  • PDF

A Novel High Frequency Linked Photovoltaic Power Conditioning System including Battery Storages (에너지 저장장치를 갖는 새로운 고주파 링크형 태양광 발전 시스템)

  • Yoo, Cheol-Hee;Ji, Sang-Keun;Park, Jung-Pil;Jung, Nam-Sung;Roh, Chung-Wook;Hong, Sung-Soo;Han, Sang-Kyoo
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.188-189
    • /
    • 2010
  • 기존의 에너지 저장장치를 갖는 계통연계형 태양광 발전 시스템은 태양광 모듈의 높은 개방전압으로 인하여 별도의 양방향 컨버터를 이용하여 배터리에 에너지를 충방전 해왔다. 이러한 시스템은 구조상 다수의 반도체 소자의 사용으로 인한 제작단가 상승 및 전기적 절연의 문제가 발생한다. 이러한 문제점을 개선하기 위하여 본 논문에서는 새로운 구조의 에너지 저장장치를 갖는 고주파 링크 방식의 계통연계형 태양광 발전 시스템을 제안하며, 제안된 시스템의 이론적 분석을 수행하고, PSIM 시뮬레이션 툴을 이용한 모의 실험을 통해 그 우수성을 검증한다.

  • PDF

Study on the Weight Reduction of Auxiliary Power Supply System for Electric Railway Vehicles (철도차량 보조전원장치의 경량화에 관한 연구)

  • Shin, H.K.;Cho, J.H.;Shin, H.C.;Kim, J.B.;Jho, J.M.;Baek, S.G.;Lee, G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.174-175
    • /
    • 2012
  • 철도 분야에서도 환경 보호 및 에너지 절감을 위한 경량화 연구가 활발히 진행 되고 있다. 본 논문에서는 철도차량의 보조전원장치 경량화에 대해 설명 한다. 기존의 철도차량의 보조전원 장치는 내부 필터 리액터, 변압기 등이 중량의 상당한 부분을 차지 하고 있고, 이는 시스템 중량 저감을 위한 고민에서 가장 큰 위치를 차지 한다. 본 논문에서는 공진형 컨버터를 사용하고 스위칭 주파수를 높여 필터 리액터, 변압기 등을 경량화 하였다. 150kW급 시제품에 대한 모의해석과 실험을 통해 입증 하였다.

  • PDF

Development of Two-Dimensional Sediment Transport Model Using Observed Erosion Rate (침식률 측정자료를 이용한 2차원 퇴적물 수송모형의 개발)

  • Jeong, Tae-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.687-699
    • /
    • 2001
  • A 2-dimensional numerical sediment transport model has been developed by using erosion rates observed by SEDFLUME. The model un boundary-fitted coordinate can reduce inaccuracy of sediment model with accurate erosion data. Suspended transport and bed load transport are included in the model together. The model results gave good agreement with particle size distributions in 1-d channel and was more accurate than that of HIDAS of 1-dimensional model. The model applied to an enlarging channel to check model performance in 2-dimensional domain. Bed coarsening reduced erosion and deposition.

  • PDF

Empirical experiment to improve the applicability of the formula for time of concentration (홍수도달시간 산정식 적용성 개선을 위한 실증실험)

  • Keum, Ho Jun;Ko, Taekjo;Joo, Jaeseung;Kim, Yerim;Jung, Dojoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.123-123
    • /
    • 2021
  • 도시하천유역이나 복합유역 등 지역적 성향을 고려한 도달시간 산정에 관한 연구는 현재까지도 미흡한 실정이다. 소규모 유역의 홍수량을 산정할 경우 유하시간보다 유입시간 비중이 상대적으로 크다. 그러나 유하시간만을 고려하여 도달시간을 산정할 때, 소규모 유역의 경우 하도가 없고 유역면적이 5km2 내외 또는 하도의 저류 효과를 기대할 수 없는 경우 도달시간이 짧아 홍수량이 과대 산정된다. 이를 극복하고자 재해영향성평가등의 협의 실무지침에서는 도달시간 이외에 매개변수인 저류상수를 인위적으로 증가시키는 방법을 제안하고 있다. 하지만 이 방법 역시 유역의 물리적인 특성을 나타내는 변수를 왜곡한다는 근복적인 문제를 완전히 해결하지 못하였다. 이에 본 연구에서는 기존 중·대규모 하천을 대상으로 수행된 연구결과를 바탕으로 제안된 홍수 도달시간 산정방법의 한계를 극복하고, 유입시간이 지배적인 소규모 복합유역에 적용 가능한 도달시간 산정방안을 제시하고자 한다. 이를 위해 실증실험을 통해 기존 유입시간 산정식을 개선하고, 도시수문 모니터링 시범유역에 적용하여 정확성을 평가하고자 하였다. 먼저, 홍수도달 시간 측정을 위한 강우유출 실내 실험장치를 제작하였다. 실험장치는 본체(길이3m×폭1.2m×높이0.8m)와 경사조절 장치(0~15도)를 포함하고 있다. 본체 전면부를 타공(ø10mm)하고 상·하단에서 지표와 기저유출을 집수하여 티핑버킷으로 유량을 측정하였고, 토체 내에는 토양수분센서를 설치하여 강우유출 발생시간 동안 토양수분 변화를 측정하였다. 본 연구에서는 하도흐름인 유하시간(Kraven 공식)을 계산하여 도달시간을 산정하기 보다 지표면 흐름인 유입시간(Kerby 공식)에 보정계수를 도입하여 도달시간을 산정하는 방안을 검토하였다. 실험 결과, 불투수 면적비율이 증가함에 따라 도달시간은 감소하고, 불투수 유역이 하류에 위치할수록 유출발생시간이 빨라졌다. 실증실험 결과를 바탕으로 도시수문 모니터링 시범유역에 적용하여 기존 유하시간과 저류상수를 보정하는 도달시간 산정방식(연속형 Kraven)과 유입시간을 보정한 도달시간 산정(수정 Kerby)으로 도출된 유출량을 실측 유량과 비교하였다. 그 결과 제안된 홍수도달시간 산정식에서 모의된 홍수량이 기존 방식과 유사하거나 우수한 첨두홍수량을 보였으며, 설계자 임의성이 배제된 일관성있는 해석값을 제시해 줄 것으로 판단된다.

  • PDF

The Effects of Coolant Inventory and Noncondensible Gas on the Natural Circulation in a PWR Loop System (PWR루프계통에서 냉각재 재고량 및 비응축성 가스의 자연순환에 미치는 영향)

  • Cha, Jong-Hee;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.308-320
    • /
    • 1989
  • The objective of this work is to investigate the effects of diminished primary coolant inventory and the presence of noncondensible gas during single- and two-phase natural circulation in a PWR loop model. The test model was composed of two loops with a U-tube heat exchanger in each loop. Through a series of tests, it has been confirmed that the two-phase natural circulation flow rates were greatly dependent on primary coolant inventory as previous investigators observed. The primary coolant inventory limit to maintain two-phase natural circulation was found to be the amount of the coolant necessary to keep the waterline of the coolant nozzle hole center in this model. The presence of noncondensible gas impede the single-phase natural circulation, but it did not affect the two-phase natural circulation significantly.

  • PDF

Study on Electrically Powered Left Ventricular Circulation Assist Device (좌심실 전동순환 보조장치에 관한 연구)

  • Kim, Myoung-Nam;Lee, Jeong-Woo;Chang, Bong-Hyun;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • This paper outlines the development of a non-pulsatile axial flow type blood pump control system. By utilizing blood pressure and heart rate, this system can assist the left ventricle in controlling blood pressure and blood volume. The system is comprised of a blood pump, signal sensor, signal interface, and signal-processing component. A control algorithm is also proposed which can control non-pulsatile, continuous blood flow in the human circulatory system. To facilitate the control required for non-pulsatile blood pump in a physiological system, an experimental control rule was developed utilizing ECG and blood pressure data, both of which are easily detectable variables in the body. The system was then tested using a mock-up circulation system and we found that it is possible that this systems could be temporarily used in clinic.

  • PDF

Optical Measurement of Blood Oxygen Saturation for Artificial Heart Using Wavelength of 665nm and 805nm (665nm와 805nm의 파장을 이용한 인공심장용 혈중 산소포화도의 광학적 측정)

  • Park, Se-Kwang;Kwon, Ki-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.75-80
    • /
    • 1993
  • This study describes a non-invasive optical sensor and system in order to obtain oxygen saturation of blood, in-vitro. The sensor contains LED 665nm and 805nm of wavelength for light source and PIN photodiode for light detector in flat pack. The sensor system for measurement of oxygen saturation has breadboarded, including signal amplifier, filter, displayer, A/D converter, microprocessor and memory. Experimental set-up for non-invasive measurement of oxygen saturation in-vitro was done. When the variation of oxygen saturation is compared with that of each wavelength, the variation of 665nm is more than that of 805nm by five times. As oxygen saturation varies from 100% to 60%, and the reflection ratio (R805/R665) is changed linearly. The oxygen saturation in $100%{\sim}60%$ range can be measured with about 5% resolution by the developed sensor, such that if this sensor connects with the main artery and vein, the artificial heart can be controlled rapidly and precisely from measurement of the sensor.

  • PDF

FADA: A fuzzy anomaly detection algorithm for MANETs (모바일 애드-혹 망을 위한 퍼지 비정상 행위 탐지 알고리즘)

  • Bae, Ihn-Han
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.6
    • /
    • pp.1125-1136
    • /
    • 2010
  • Lately there exist increasing demands for online abnormality monitoring over trajectory stream, which are obtained from moving object tracking devices. This problem is challenging due to the requirement of high speed data processing within limited space cost. In this paper, we present a FADA (Fuzzy Anomaly Detection Algorithm) which constructs normal profile by computing mobility feature information from the GPS (Global Positioning System) logs of mobile devices in MANETs (Mobile Ad-hoc Networks), computes a fuzzy dissimilarity between the current mobility feature information of the mobile device and the mobility feature information in the normal profile, and detects effectively the anomaly behaviors of mobile devices on the basis of the computed fuzzy dissimilarity. The performance of proposed FADA is evaluated through simulation.

Consideration on the helium leak detection in a large vacuum chamber (대형 진공용기의 헬륨 누설검사 방법에 대한 고찰)

  • In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.235-243
    • /
    • 2007
  • Nowadays, in our country, large vacuum chambers for huge experimental facilities such as the tokamak fusion device, high power neural beam test stand, and space simulator have been constructed. In such a vacuum chamber of very large size, it is quite complicate to check on leakage quantitatively, while the probability of a leak is relatively high. To investigate the feasibility of applying reliably a helium leak detection to the huge vacuum chambers, and to find a reasonable methodology of choosing an optimum set-up for leak detection, several virtual constructions of the leak detection system have been analyzed by calculating the pressure distribution in the system and the helium level in the sensor part.