• Title/Summary/Keyword: 모세관 모델

Search Result 49, Processing Time 0.025 seconds

Application of CFD-VOF Model to Autonomous Microfluidic Capillary System (마이크로 모세관 유동 해석을 위한 CFD-VOF 모텔 응용)

  • Jeong J.H.;Im Y.H.;Han S.P.;Suk J.W.;Kim Y.D.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.224-229
    • /
    • 2004
  • The objective of this work is not only to perform feasibility studies on the CFD (computational fluid dynamics) analysis for the capillary system design but also to provide an enhanced understanding of the autonomous capillary flow. The capillary flow is evaluated by means of the commercial CFD software of FLUENT, which includes the VOF (volume-of-fluid) model for multiphase flow analysis. The effect of wall adhesion at fluid interfaces in contact with rigid boundaries is considered in terms of static contact angle. Feasibility studies are first performed, including mesh-resolution influence on pressure profile, which has a sudden increase at the liquid/gas interface. Then we perform both 2D and 3D simulations and examine the transient nature of the capillary flow. Analytical solutions are also derived for simple cases and compared with numerical results. Through this work, essential information on the capillary system design is brought out. Our efforts and initial success in numerical description of the microfluidic capillary flows enhance the fundamental understanding of the autonomous capillary flow and will eventually pave the road for full-scale, computer-aided design of microfluidic networks.

  • PDF

An Assessment of Friction Factor and Viscosity Models for Predicting the Refrigerant Characteristics in Adiabatic Capillary Tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Lee, Sung-Hong;Kim, Lyun-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.140-148
    • /
    • 2009
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses and flashing simultaneously. In this paper flow characteristics of adiabatic capillary tubes were simulated with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models. The predicted pressure distribution and mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing suitable correlations of friction factor, two-phase viscosity and two-phase frictional multiplier.

An assessment of friction factor and viscosity models for predicting the refrigerant characteristics in adiabatic capillary tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Kim, Lyun-Su
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.47-54
    • /
    • 2008
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses, and flashing, simultaneously. In this paper flow characteristics of adiabatic capillary tubes with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models were simulated. The predicted pressure distribution, mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing the suitable correlations of friction factor and two-phase viscosity model, and two-phase frictional multiplier.

  • PDF

Structural Factors Affecting Comfort Related Fluid Transport Characteristics in Fabric (직물에서 구조적 요인이 쾌적성과 연관된 유체전달 특성에 미치는 영향)

  • 홍철재
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.11a
    • /
    • pp.1371-1372
    • /
    • 2003
  • 직물에서 구조적 요인이 쾌적성과 연관된 유체전달 특성들에 미치는 영향을 연구하였다. 고려된 구조변수는 직물을 구성하는 실의 구성성분 그리고 꼬임수이다. 측정한 쾌적성과 연관된 물성으로 수분 흡수성, 수분 증발성, 그리고 수분 투과성이다. 이들 물성은 고려된 구조 인자들에 의해 큰 영향을 받았다. 결과들에 대한 객관적 분석과 이해를 위해 실에서 접촉적각, 직물에서 모세관 흡수 곡선, 그리고 기공크기를 측정하였으며, 또한 기존 이론들을 수정한 모델을 도입하여 모사 설명하였다.

  • PDF

Experimentation and modeling on the flow of R407c and R290 through capillary tubes (R407C 및 R290 냉매에 대한 모세관내 유동특성 실험 및 모델링)

  • 김용찬;조일용;최종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.492-498
    • /
    • 1999
  • Mass flow rates of R407C and R290 through capillary tubes were measured with various capillary tube geometries and flow conditions. For all refrigerants tested in the present study, mass flow rate through the capillary tube was strongly dependent on the condensing pressure, subcooling and capillary length and diameter. The flow rate of R407C was 5~10[%] higher than that of R22 at the same condensing temperature and degree of subcooling, while flow rate for R290 was 40[%] lower than that for R22. Based on experimental results, an empirical correlation was developed using Pi theorem to predict the mass flow rate through capillary tubes. The predicted flow rates using the model were consistent with the experimental data within ${\pm}$10[%].

  • PDF

Analytic Model for Predicting the Permeability of Foam-type Wick (폼 타입 윅의 투과도를 예측하기 위한 해석 모델)

  • Ngo, Ich-Long;Byon, Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.391-396
    • /
    • 2016
  • Wicks play an important role in determining the thermal performance of heat pipes. Foam-type wicks are known to have good potential for enhancing the capillary performance of conventional types of wicks, and this is because of their high porosity and permeability. In this study, we develop an analytic expression for predicting the permeability of a foam-type wick based on extensive numerical work. The proposed correlation is based on the modified Kozeny-Carman's equation, where the Kozeny-Carman coefficient is given as an exponential function of porosity. The proposed correlations are shown to predict the previous experimental results well for an extensive parametric range. The permeability of the foam-type wick is shown to be significantly higher than that of conventional wicks because of their high porosity.

Interpretation of Permeation Characteristics and Membrane Transport Models Through Polyamide Reverse Osmosis Membrane (Polyamide 역삼투막의 투과성능과 막 이동 모델의 해석)

  • 김노원;김영길;이용택
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.75-84
    • /
    • 2004
  • In this study, we present a noble study far membrane transport models using chlorine resistance of polyamide RO membranes. Membrane transport mechanism is investigated by the comparison of membrane permeation performance under the continuous and Intermittent operation modes with mixed feed solution containing NaOCl and NaCl. Analysis of permeation performance indicates that solution-diffusion model and preferential adsorption-capillary flow model are relatively efficient according to operation mode. Under the continuous flow state, mass transfer depends on preferential adsorption-capillary flow model rather than solution-diffusion model. On the other hand, it prefers solution-diffusion model to preferential adsorption-capillary flow model under the stationary state. SEM images of NaOCl treated membrane surfaces strongly support these conclusions. These surface images reveal that NaOCl treated membrane in continuous operation mode exhibits ridge and valley structure in some fraction of the surface area, whereas that in intermittent operation mode shows surface degradation entirely.

Analytical Modeling of a Loop Heat Pipe with a Flat Evaporator by Applying Thin-Film Theory (평판형 증발부를 갖는 루프히트파이프에 대해 박막이론을 적용한 해석적 모델링)

  • Jung, Eui-Guk;Boo, Joon-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1079-1085
    • /
    • 2010
  • A steady-state analytical model was presented for a loop heat pipe (LHP) with an evaporator that has a flat geometry. On the basis of a series of reviews of the relevant literature, a sequence of calculations was proposed to predict the temperatures and pressures at each important part of the LHP: the evaporator, liquid reservoir (compensation chamber), liquid line, vapor line, and condenser. The analysis of the evaporator, which is the only part in the LHP that has a capillary structure, was emphasized. Thin-film theory is applied to account for the pressure and temperature in the region adjacent to the liquid-vapor interface in the evaporator. The present study introduced a unique method to estimate the liquid temperature at the interface. Relative freedom was assumed in the configuration of a condenser with a simplified liquid-vapor interface. Our steady-state model was validated by experimental results available in the literature. The relative error was within 3% on the absolute temperature scale, and reasonable agreement was obtained.

Damped Oscill ations of the (Hard)Contact Lenses Posterior to the Blink (순목 후 콘택트(하드)렌즈의 감쇄 진동)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.173-184
    • /
    • 2005
  • A capillary action-induced tension develops in the tear layer between the contact lens and cornea, which leads to the restoring force due to difference in the layer thickness between either upper and lower or left and right side of the lens when it is displaced off the equilibrium position as a result of blinking. Suppose the lens was displaced a certain distance from the equilibrium position, lens starts to oscillate toward the equilibrium position with the decreasing amplitude due to the restoring force as well as the velocity dependent viscous damping force in the tear layer. A mathematical model which consists of the differential equations and their numerical solution was proposed to analyze the damped oscillations of lenses. The model predicts the time dependence of lenses after the blink varying the various parameters such as Be, diameters, masses and positions displaced from equilibrium. As the Be and mass of lens increases the rate of amplitude reduction decreases, which requires a more time for the lens to return to the equilibrium position. It seems that varying the lens' displacement and diameters affect the lens' motion very little.

  • PDF

Autogenous Shrinkage of Cement Paste Considering Disjoining Pressure in Thin Adsorbed Region (흡착 영역 분리 압력을 고려한 시멘트페이스트의 자기 수축)

  • Lee, Chang-Soo;Park, Jong-Hyok
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.213-218
    • /
    • 2006
  • Meniscus, adsorbed layer thickness, capillary pressure and disjoining pressure was deduced in extended meniscus region in cement paste pore by hydrostatic equilibrium. From the results, the relationship between pore size and adsorbed layer thickness could be derived and adsorbed layer thickness represents $0.299{\sim}2.700nm$ according to pore size $1nm{\sim}1{\mu}m$. Especially, disjoining pressure rapidly Increased in less than 10 nm pore size according to adsorbed layer thickness. Therefore, it is interpreted that autogenous shrinkage of cement paste is highly increases in formation of less than 10 nm pore size. Predictions of autogenous shrinkage in cement paste considering driving force for autogenous shrinkage with capillary pressure and disjoining pressure was low in comparison with experiment values between $1{\sim}4$ days and high in later period. These tendency could be thought that pore damage by mercury injection in early age makes shrinkage driving force underestimate and assumption for unsaturated independent pore makes overestimate. These interactions might be needed corrections considering on hydration or pore replacement model.