• 제목/요약/키워드: 모서리형 화재

검색결과 4건 처리시간 0.016초

FDS를 이용한 실내화재 모사의 문제점 II. 벽면형 및 모서리형 화재 (A Numerical Study of a Room Fire for Fire Sizes II. wall fire and corner fire)

  • 고경찬;박외철
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.9-13
    • /
    • 2004
  • To confirm the previous finding that FDS predicts a fire growth rate too rapid compared with an experiment in a center fire in a room with an opening, the same computational fluid dynamics was applied to two types of fires, wall fire and comer fire. First the grid size was chosen to eliminate possible numerical errors due to a coarse grid system. Then the two types of fires were simulated for three different fire sizes, 7.65, 21.25, and 51.57kW for each type, which are the same as in the experiment to be compared with. The fires were predicted to grow too fist although the average temperatures and heights of the neutral planes were in good agreement with measurement.

실내공간에서 화재 발생위치에 따른 연기거동에 대한 실험연구 (An Experimental Study of Smoke Movement of the Various Fire Location in Room)

  • 유홍선;정진용;이재하;홍기배
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.703-709
    • /
    • 2002
  • In order to investigate the smoke movement in three dimensional room fires, the center fire, wall fire and corner fire plume in different sized fires were studied experimentally by rectangular pool fire using methanol as a fuel. As the fire size became larger for the center fires placed at the center of the floor, the air flow rate entrained through the opening, average hot layer temperature, flame angle deflected backwards and mean flame height was observed to increase. On the other hand, as the fire size became smaller, the neutral plane height in the door and time reached steady-state was observed to decrease. The average hot layer temperature, mean flame height and doorway neutral plane height obtained from comer fire were higher than those produced by wall fires and center fires. The simple model for describing the effect of walls on the mean flame height was presented. It was shown that the model provides a good description of the present measurements, when used with the assumption by Hansell(1993), that the increase of the average flame height is equal to the ratio of the open to the total perimeters of the trays. Also the two models for predicting the effects of walls on the mean flame height were presented. These models overestimated the measured values of the mean flame height above fuel trays close to a wall and in a corner by approximately 19-26%, respectively.

선박 실내공간에서 화재의 크기 및 위치에 따른 연기거동특성 (Smoke Movement Characteristics in the Ship's Indoor Spaces with Fire Size and Location)

  • 한원희;조대환
    • 해양환경안전학회지
    • /
    • 제11권1호
    • /
    • pp.53-59
    • /
    • 2005
  • 항해 중 발생하는 선박의 화재는 외부로부터 소방 활동을 기대할 수 없으므로 선내에서 자체적으로 처리해야 하기 때문에 매우 위험하다. 더구나 여객선의 경우에는 재산상의 피해는 물론이고, 대형 인명 사고로 이어질 수 있으므로 더욱 심각하다 화재가 발생하며 연소과정에서 열 뿐만 아니라 많은 연기가 동시에 발생하고 다량의 유독성 연기는 질식사와 같은 인명피해를 가져오게된다. 이 연구의 목적은 선박의 실내공간에서 화재의 크기 및 위치에 따른 연기거동 특성을 규명하는 것이다. 화원의 크기를 두가지로 하고 세가지 형태의 화재 위치에 따라 실험적 연구를 수행하였다. 그 견과 연기 및 열의 확산 특성은 모서리형 화재에서 가장 가파른 상승 곡선을 보였다.

  • PDF

선박 실내공간에서 화재의 크기 및 위치에 따른 연기거동특성 (Smoke Movement Characteristics in the Ship's Indoor Spaces with Fire Size and Location)

  • 한원희;조대환
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2005년도 춘계학술발표회
    • /
    • pp.167-173
    • /
    • 2005
  • 항해 중 발생하는 선박의 화재는 외부로부터 소방 활동을 기대할 수 없으므로 선내에서 자체적으로 처리해야 하기 때문에 매우 위험하다. 더구나 여객선의 경우에는 재산상의 피해는 물론이고, 대형 인명 사고로 이어 질수 있으므로 더욱 심각하다. 화재가 발생하면 연소과정에서 열 뿐만 아니라 많은 연기가 동시에 발생하고 다량의 유독성 연기는 질식사와 같은 인명피해를 가져오게 된다. 이 연구의 목적은 선박의 실내공간에서 화재의 크기 및 위치에 따른 연기거동특성을 규명하는 것이다. 화원의 크기를 두가지로 하고 세가지 형태의 화재위치에 따라 실험적 연구를 수행하였다. 그 결과 연기 및 열의 확산 특성은 모서리형 화재에서 가장 가파른 상승 곡선을 보였다.

  • PDF