• Title/Summary/Keyword: 모드참여계수

Search Result 12, Processing Time 0.024 seconds

Estimation of the First Modal Participation Factor of a Shear Building under Earthquake Load (지진하중을 받는 전단구조물의 1차 모드참여계수 산정)

  • Hwang, Jae-Seung;Kim, Hong-Jin;Kang, Kyung-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.25-32
    • /
    • 2005
  • Seismic load is distributed to modes of a structure through the modal participation factor(MPF). The modal participation factor is essential to analyze structural response under earthquake load. MPF of a real structure differs from that of analytical mathematical model due to the error induced from analytical assumptions and during the construction. In this study, an identification method is proposed to calculate the 1st MPF of real structure based on $H^{\infty}$ optimal model reduction. The MPF is obtained from the relationship between observability and controllability matrices realized from system identification and those of a prototype 2-degree state space model. The proposed method is verified thorough numerical examples.

Seismic Evaluation of Structural Integrity of Main Cooling-Water Pump by Response Spectrum Analysis (응답스펙트럼법을 이용한 지진하중을 받는 원전용 주냉각수펌프의 내진 건전성 평가)

  • Chung, Chul-Sup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1773-1778
    • /
    • 2010
  • To evaluate the structural integrity of the main cooling-water pump of a nuclear power plant under different seismic conditions, the seismic analysis was performed in accordance with IEEE-STD-344 code. The finite element computer program, ANSYS, was used to perform both mode frequency analysis and response spectrum analysis for the pump assembly. The natural frequencies, the mode shapes, and the mode participation factors were obtained from the results of the mode frequency analysis. The stresses resulting from various loadings and their combinations were within the allowable limits specified in the above-mentioned IEEE code. The results of the seismic evaluation fully satisfied the structural acceptance criteria of the IEEE code. Thus, it was proved that the structural integrity of the pump assembly was satisfactory.

Modal Characteristics of a Structure with Stiffness and Damping Eccentricit (강성 및 감쇠 비대칭 구조물의 모드 특성)

  • 김진구;방성혁
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.421-432
    • /
    • 2002
  • In this study the modal characteristics and responses of an asymmetric structure with added viscoelastic dampers were investigated for design parameters such as eccentricity of stiffness and added dampers, the loss factor of the damping materials used. For modal characteristics, variation of the quantities such as natural frequencies, modal damping ratios, modal participation factors, and dynamic amplification factors were observed, and displacements at flexible and stiff edges, and at center of mass were obtained. Based on the results, the problem of the optimum damper distribution to minimize the torsional effects was addressed, and the proposed method for optimum damper distribution was applied to a multi-story structure to verify the applicability Finally the effect of viscous and viscoelastic dampers were compared by varying the loss factor of the viscoelastic material.

Efficient Dynamic Analysis Using Complex Modal Superposition for Tall Buildings with Viscoelastic Dampers (복소모드중첩법을 이용한 점탄성감쇠기를 가진 고층건물의 효율적인 동적해석)

  • 김진구;홍성일;이경아;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.4
    • /
    • pp.671-679
    • /
    • 1999
  • 건물의 진동에너지 소산능력을 향상하기 위하여 점탄성감쇠를 설치하게 되면 이른바 비비례 감쇠시스템이 되어 구조물은 복소수형태의 고유모드와 고유치를 가진다. 복소모드중첩법은 이러한 복소모드를 이용하여 중첩함으로써 비비례 감쇠시스템 구조물의 정확한 동적 거동을 얻을 수 있는 방법이다. 그러나 건물이 고층화되면 많은 자유도로 인하여 고유치해석 및 모드중첩과정에서 많은 시간과 노력이 필요하게 된다. 본 논문에서는 효율적인 구조물의 모형화를 위하여 강막가정과 행렬응축기법을 적용하였다. 또한 몇 개의 주요 모드만을 선택하여 중첩하는 방법에 대하여 연구하였으며 구조물의 진동에 영향을 주는 모드의 선택을 위한 복소모드 응답참여계수를 제안하였다. 제안된 해석방법의 정확성과 효율성을 검토하기 위하여 예제 구조물을 대상으로 해석한 결과, 응답의 정확성을 유지하면서 해석에 필요한 시간을 대폭 절감할 수 있었다.

  • PDF

The Applications of Viscoelastic Dampers for Vibration control (고층건물의 진동제어를 위한 점탄성 감쇠기의 활용)

  • 김진구;홍성일;이경아;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.77-88
    • /
    • 2000
  • 복소모드 중첩법은 점탄성 감쇠기가 설치된 비비례 감쇠시스템의 정확한 동적 거동을 예측할 수 있는 방법이지만 많은 자유도를 갖는 고층건물의 해석시 고유치 해석과 모드중첩과정에서 많은 시간과 노력이 필요하게 된다. 본 논문에서는 효율적인 모형화를 위하여 강막가정과 행렬응축기법을 적용하고 구조물의 진동에 영향을 주는 주요모드의 선택을 위한 복소모드 응답참여계수를 제안하므로써 복소모드 중첩법의 효율성은 높였다. 또한 비비례 감쇠시스템에서 감쇠를 고려하여 응답스펙트럼을 재구성한후 선택된 주요 모드를 중첩하여 최대층간변위가 발생하는 곳에 감쇠기를 설치하였다 이 방법은 감쇠기가 설치된 구조물에 대하여 만족되는 수준의 최대층간변위가 발생할 때 까지 고유치 해석만을 반복.수행하면서 감쇠기를 연속적으로 설치하는 방법이다. 제안된 방법의 정확성과 효율성을 검토하기 위하여 예제 구조물의 대상으로 해석한 결과 응답의 정확성을 유지하면서 해석에 필요한 시간을 대폭 절감할 수 있었다.

  • PDF

Fast intra mode decision using DCT coefficient distribution in H.264/AVC (H.264/AVC에서 DCT계수 분포를 이용한 고속 인트라 모드 결정 방법)

  • Hong, Sung-Wook;Lee, Yung-Lyul
    • Journal of Broadcast Engineering
    • /
    • v.15 no.4
    • /
    • pp.582-590
    • /
    • 2010
  • he rate-distortion optimization (RDO) method in the H.264/AVC encoder is a technology that improves the coding efficiency, but increases the computational complexity. In this paper, a fast Intra mode decision algorithm using DCT (Discrete Cosine Transform) coefficients distribution is proposed to reduce the H.264 encoder complexity. The proposed method reduces the encoder complexity on average 68.40%, while the coding efficiency is slightly decreased compared with the H.264/AVC encoder.

Modal Analysis of Structures (구조물의 모달해석에 관한 연구)

  • Kim, Hong-Jin;Park, Je-Woo;Hwang, Jae-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.665-668
    • /
    • 2008
  • The load distribution to each mode of a structure under seismic loading depends on the modal participation factor. The factor of an idealized analytical model, however, is different to the actual one due to modeling and construction error. Therefore, there exist limits on the estimation of actual behavior. In this study, an identification procedure for participation factor based on vibration test is proposed. The procedure has an advantage that the mode shape vector can also be estimated directly from the participation factor. The numerical simulation using a three story building is performed to evaluate the proposed procedure.

  • PDF

Dynamic Load Factor for Floor Vibration due to Lively Concerts (공연하중에 의한 바닥진동 설계용 동하중계수)

  • Hong, Kap Pyo;Yoon, Kwang Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.721-728
    • /
    • 2002
  • Modern structrues are being built using high-strength and light-weight construction materials resulting in decreased structural mass and damping properties. Rhythmic activities such as jumping, dancing and clapping during lively concerts can produce excessive vibration of steel structures. In this study, dynamic load factors that occur during lively concerts were presented through vibration test and real-time monitoring of an existing concert hall. The vibration test included modal analysis and jumping test according to the forcing frequencies and the number of participants. Dynamic load foactors were acquired directly from peak acceleration responses of each harmonics. Comparing NBCC 1995, the 3rd harmonic must be included in the design of concert halls. Dynamic load factors must be increased as a result of the vibration test.

A Study on the Behavior of High-rise Buildings Considering Soil-Structure Interaction (지반-구조물 상호작용을 고려한 고층 구조물의 거동에 관한 연구)

  • Kim, Se-Hyun;Park, Sung-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.243-251
    • /
    • 2005
  • In the seismic design the pile foundation system of the buildings generally have been modeled to have a fixed end for its convenience and conservativeness. But it is necessary to consider the soil-structure interaction for more reliable design. In this study, the framed tube building and brace tube building with pile foundation system under earthquake were analyzed considering soil-structural interaction by 3 pile foundation modeling methods; fixed-end model, 6 springs model and p-y springs model. And 2 soil conditions were used in analysis. For each cases, displacements, drifts, maximum stress, periods and 1st mode mass participation ratios were compared.

A Numerical Study on Improvement in Seismic Performance of Nuclear Components by Applying Dynamic Absorber (동흡진기 적용을 통한 원전기기의 내진성능향상에 관한 수치적 연구)

  • Kwag, Shinyoung;Kwak, Jinsung;Lee, Hwanho;Oh, Jinho;Koo, Gyeong-Hoi
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.1
    • /
    • pp.17-27
    • /
    • 2019
  • In this paper, we study the applicability of Tuned Mass Damper(TMD) to improve seismic performance of piping system under earthquake loading. For this purpose, a mode analysis of the target pipeline is performed, and TMD installation locations are selected as important modes with relatively large mass participation ratio in each direction. In order to design the TMD at selected positions, each corresponding mode is replaced with a SDOF damped model, and accordingly the corresponding pipeline is converted into a 2-DOF system by considering the TMD as a SDOF damped model. Then, optimal design values of the TMD, which can minimize the dynamic amplification factor of the transformed 2-DOF system, are derived through GA optimization method. The proposed TMD design values are applied to the pipeline numerical model to analyze seismic performance with and without TMD installation. As a result of numerical analyses, it is confirmed that the directional acceleration responses, the maximum normal stresses and directional reaction forces of the pipeline system are reduced, quite a lot. The results of this study are expected to be used as basic information with respect to the improvement of the seismic performance of the piping system in the future.