• Title/Summary/Keyword: 모듈 정도

Search Result 807, Processing Time 0.027 seconds

Development of the Expert System for Diagnosing Silicone Oil-filled Transformer (실리콘 유입변압기 진단을 위한 전문가시스템 개발)

  • 문종필;김재철;임태훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • In this paper, the diagnostic expert system for silicone oil-filled transformer is developed using dissolved gas analysis(DGA). There are many diagnostic methods for diagnostic oil-immersed transformer. But DGA is used to the proposed expert system since it has been verified that DGA is very efficient diagnostic method for transformer. In addition, it is resonable that fuzzy rule, degree of inclusion and fuzzy measure must be considered to handle the uncertainty nature of gas boundary and rules. The proposed expert system consists of knowledge base module, inference engine module and human-machine interface(HMI) module. The knowledge base module consists of the knowledge using the rule. The inference engine module is used to the fuzzy rule. The history of the transformer gas data is managed by the database. the effect of the proposed expert system is verified by case studies.

An Experimental Study on Flexural Strength of Modular Composite profiled Beams (휨 보강된 모듈단면 합성 프로파일보의 휨 내력에 관한 실험적 연구)

  • Ahn, Hyung Joon;Ryu, Soo Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.323-333
    • /
    • 2007
  • This paper presents a study that attempted to improve the site applicability of profile sheets and check the effects of bending reinforcement in composite profiled beams, and consequently, to suggest an improved modular-type CB2 and two types of bending reinforcement methods. As a result of the reinforcing and reforming modular profiled beam experiment conducted, CBIIshowed an adequate deformation capacity as well as a sufficient plastic plateau at the maximum load and thereafter. For all the specimens, an insignificant modular slip occurred while linear relations were kept constant, at up to approximately 50% of the maximum load and at constant linear relations. The experimental values were very low. Probably, due to the small-scale experiment, the area of the concrete for the concrete filling and covering might have been insufficient, which might have led to the failure to improve the strength. Comparing the results with the standard design stress, all the specimens-except for T16 and B16-indicated more than 0.9. Based on the standard design stress, the reinforced modular profiled beam was consideredto have positive applicability.

Automatic Combination & Assembly System for Phone Camera Lens Module (폰 카메라 렌즈모듈 자동 조합시스템 개발)

  • Song, Jun Yeob;Ha, Tae Ho;Lee, Chang Woo;Kim, Dong Hoon;Jeon, Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.2
    • /
    • pp.219-225
    • /
    • 2014
  • An automatic combination and assembly system for phone-camera lens modules was developed. The system enables the assembly of the relative orientation of the individual lenses making up the lens module. Conventional assembly systems assemble a lens module from eight assembly units. The developed system reduces this number to half by combining each lens and a spacer into a single assembly unit. Also, the number of transfer stages for sequential assembly is minimized without increasing the assembly time. Therefore, high productivity and a footprint that is only about 25 % of that of a conventional assembly system can be realized. The system features a modular design to allow it to cope with rapid changes in the market. Only a few components, such as the picker and guide, need to be replaced for changing to a new assembly model.

Fine tuning of wavelength for the intenrnal wavelength locker module at 50 GHz composed of the photo-diode array black with the multi-channel tunable laser diodes in DWDM application (DWDM용 다채널 파장 가변 레이저 다이오드 모듈을 위한 다수개의 광 수신 소자를 갖는 50 GHz 내장형 파장 안정화 모듈의 파장 미세 조정)

  • 박흥우;윤호경;최병석;이종현;최광성;엄용성;문종태
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.5
    • /
    • pp.384-389
    • /
    • 2002
  • A new idea of the wavelength locking module for DWDM application was investigated in the present research. Only one etalon photo-diode is generally used in the internal/external wavelength locking system. For the internal wavelength locking module with 50 GHz applications, an algle tuning method of the etalon commonly applied. However, the alignment process of the etalon with the angle tuning method is limited because the lock performance is extremely sensitive accoriding to the change of the tilting angle. In an optical viewpoint, the alignment tolerance of the locker module with the etalon PD array block was good, and the precise tuning of the wavelength was possible. The characteristics of free spectral range (FSR) and peak shift of wavelength according to the tilting angle with the locker module was investigated. For the present module, the optimized initial tilting angle was experimentally obtained.

Design for Enhanced Precision in 300 mm Wafer Full-Field TTV Measurement (300 mm 웨이퍼의 전영역 TTV 측정 정밀도 향상을 위한 모듈 설계)

  • An-Mok Jeong;Hak-Jun Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.88-93
    • /
    • 2023
  • As the demand for High Bandwidth Memory (HBM) increases and the handling capability of larger wafers expands, ensuring reliable Total Thickness Variation (TTV) measurement for stacked wafers becomes essential. This study presents the design of a measurement module capable of measuring TTV across the entire area of a 300mm wafer, along with estimating potential mechanical measurement errors. The module enables full-area measurement by utilizing a center chuck and lift pin for wafer support. Modal analysis verifies the structural stability of the module, confirming that both the driving and measuring parts were designed with stiffness exceeding 100 Hz. The mechanical measurement error of the designed module was estimated, resulting in a predicted measurement error of 1.34 nm when measuring the thickness of a bonding wafer with a thickness of 1,500 ㎛.

Dynamic Reliability Analysis (시스템다이내믹스 기법의 공학적 응용)

  • 곽상만
    • Proceedings of the Korean System Dynamics Society
    • /
    • 2003.02a
    • /
    • pp.65-71
    • /
    • 2003
  • 장점 각종 Dynamic 특성을 모델화, Recovery action등 Hardware뿐만 아니라 다양한 민감도 분석이 가능, 절차서 개선, 조직 특성 등 모듈 개념을 활용할 시에 모델화 시간이 절약 기존 방법에 비해 1/2-1/10 정도의 노력, 다른 전략 모델과의 연계가 가능, 단점 정성적 Insight를 얻기 어려움, 평가 시간이 매우 김.(중략)

  • PDF

Molding and Optical Evaluation of Aspheric Glass Lenses for Camera Phone Module (카메라폰 모듈용 비구면 Glass렌즈의 성형 및 광학특성 평가)

  • Kim, Hye-Jeong;Cha, Du-Hwan;Kim, Jeong-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.3
    • /
    • pp.124-131
    • /
    • 2007
  • Aspheric glass lenses was fabricated by glass molding press(GMP), which is a plano-aspheric convox shape and intended for use as an optical design of 3 megapixel and 2.5 magnifications zoom in a camera phone module. Transcription ratio of form accuracy (PV) as well as resolution properties was measured for evaluation the molded lens. Form accuracy (PV) of the mold surface was $0.127\;{\mu}m$ in an aspheric and $0.168\;{\mu}m$ in a plano, in case of the molded lens it shows $0.205\;{\mu}m$ and $0.223\;{\mu}m$, respectively. Resolution of the molded lens was measured as a MTF[Contrast]. The molded lens shows contrast of 32.9% at 80 1p/mm and the value is similar with contrast of 33% obtained simulation.

  • PDF

The Function Construction based on Modular Design Technique (모듈러 설계기법에 기초한 함수구성)

  • Park, Chun-Myoung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.918-919
    • /
    • 2012
  • This paper present a method of function decomposition and input variable manipulation method based on modular design techniques. We obtain the column multiplicity of decomposition function according to row decomposition method. Also, the proposed partial decomposition function have advantage which is able to omit control function using t-Gate. We find the advantage for internal connection decrement 12% and T-gate number 16%, therefore we find the simple design circuit.

  • PDF

Evaluation of Power Generation Performance for Bifacial Si Photovoltaic Modules installed on Different Artificial Grass Floors (인조잔디 바닥종류에 따른 양면수광형 실리콘 태양광 모듈의 발전성능 평가)

  • Yoo, Younggyun;Seo, Yeongju;Park, Dohyun;Kim, Minsu;Jang, Hojun;Kwon, Young Hoon;Hwangbo, Chul;Kim, Woo Kyoung;Chang, Sungho
    • Journal of Energy Engineering
    • /
    • v.27 no.3
    • /
    • pp.1-9
    • /
    • 2018
  • In this study, the outdoor evaluation test was performed to characterize the highly-reflective artificial grass to be used for bifacial photovoltaic (PV) power generation system. The 60-cell n-type Si monofacial and bifacial PV modules were employed, where two types of bifacial modules were equipped with split-type and box-type junction boxes, respectively. The results showed that the split-type junction box improved the rear-side power production and thus energy yield of bifacial module compared to the box-type junction box causing the shadow effect. Highly-reflective artificial grass achieved relatively high albedo of 0.18, and excellent bifacial gain of 33%, compared to conventional artificial grass with an albedo of 0.14-0.15, and bifacial gain of 29-30%.