• Title/Summary/Keyword: 모니터링 인자

Search Result 349, Processing Time 0.031 seconds

Crack Source location Technique for nam Concrete Beam using Acoustic Emission (음향방출을 이용한 무근콘크리트 보의 균열 발생원 탐사기법)

  • 한상훈;이웅종;조홍동;김동규
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.107-113
    • /
    • 2001
  • This study was conducted preliminarily to develop the crack source location technique for plain concrete beam using acoustic emission(AE). Before the main experiment, the test of virtual An source location was achieved in plain concrete block. The sensor layout was mutually compared between triangular layout and rectangular layout. As the results of test, AE source location by triangular layout was evaluated more effective than that by rectangular layout. The specimen to apply he source location technique was man in total nine specimens (each three in 40 %, 50%, 60% of W/C ratio) which the experiment variable was the compressive strength level(W/C ratio). The bending loading method is selected by cyclic loadings to evaluate the degree of concrete damage. It is seen that Kaiser effect and Felicity effect exists through analysis of AE parameters in coming failure experiment. As a result of analyzing the felicity ratio(FR) values, it is shown that this values can be used for evaluating the degree of concerto damage. AE activity is started highly at the 70% of failure load without the compressive strength level. Thus considered by a index in constructing the system of the failure warning at application of the field structure. And the results compared the real cracking location with the source location has perceived by AE monitoring before it is appeared the primary crack by visual observation.

Impact Assessment of River Water Quality using Organic Pollutant Index - Industrial Waste Water - (유기물오염도 지표를 이용한 하천수질영향평가 - 산업폐수의 방류수질을 기준으로 -)

  • Jo, Soo-Hyun;Kang, Mee-A;Choo, Yang-Yeop;Jeong, Gyo-Cheol;Jung, Dong-Hee;Yi, Jun-Heung
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.373-379
    • /
    • 2006
  • We investigated the relationship of the organic pollutant index in wastewater where the high percentages of an organic load to a water body was found. Measuring of TOC was to identify the relationship with COD and BOD which were used already. The correlation coefficient (r) of TOC/COD, BOD/COD and TOC/BOD were effected by the types of industry such as paper, textile, chemical, food and metal industries. In food industry it was found that the highest correlation coefficient (r) of TOC/COD, BOD/COD and TOC/BOD as 0.967, 0.969 and 0.990, respectively. There is low correlation coefficient in many cases. Hence it was impossible that the use of TOC for the water standard or monitoring instead of COD and BOD directly. However it can be used as alternative index to management a water process in the case of waste water where there was found high correlation coefficient of TOC/ COD, BOD/COD and TOC/BOD. It was sure that the water quality of river body can be protected if we use these the relationship among organic index.

Optimizing the Hot-water Extraction Conditions for Acanthopanacis cortex Using Response Surface Methodology (반응표면분석법을 이용한 오가피의 열수 추출조건 최적화)

  • Kim, In-Ho;Kim, Seong-Ho;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.4
    • /
    • pp.512-520
    • /
    • 2008
  • In order to examine the effective components and antioxidative characteristics of Acanthopanacis cortex, response surface methodology was used to optimize the hot water extraction process by analyzing and monitoring the extraction condition characteristics. The total extraction yield was optimized using the extraction temperature of $84.28^{\circ}C$, extraction time of 3.59 hr and 18.37 mL/g as the amount of solvent per sample. For the effective component of eleutheroside E, the optimal extraction temperature, time and amount of solvent per sample were $81.16^{\circ}C$, 3.56 hr, and 19.06 mL/g, respectively; also, for total phenolics, the optimal conditions were $88.45^{\circ}C$, 4.33 hr, and 21.12 mL/g, respectively. Regression equations were deduced for each variable and then eleutheroside E, chlorogenic acid, and antioxidative characteristics were superimposed with the optimal conditions to obtain values for each extraction process factor. The predicted results were $81{\sim}88^{\circ}C$, $3.5{\sim}4.3hr$, and $18{\sim}21mL/g$, respectively. The estimated values for the optimal extraction conditions of Acanthopanacis cortex's effective components and antioxidative characteristics were similar to the experimental results.

Simulation for the Estimation of Design Parameters in an Aquifer Thermal Energy Storage (ATES) Utilization System Model (대수층 축열 에너지(ATES) 활용 시스템 모델의 설계인자 추정을 위한 시뮬레이션)

  • Shim Byoung-Ohan
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.54-61
    • /
    • 2005
  • An aquifer thermal energy storage (ATES) system can be very cost-effective and renewable energy sources, depending on site-specific parameters and load characteristics. In order to develop the ATES system which has certain hydrogeological characteristics, understanding the thermohydraulic process of an aquifer is necessary for a proper design of an aquifer heat storage system under given conditions. The thermohydraulic transfer for heat storage was simulated according to two sets of simple pumping and waste water reinjection scenarios of groundwater heat pump system operation in a two-layered aquifer model. In the first set of the scenarios, the movement of the thermal front and groundwater level was simulated by changing the locations of injection and pumping wells in a seasonal cycle. However, in the second set the simulation was performed in the state of fixing the locations of pumping and injection wells. After 365 days simulation period, the shape of temperature distribution was highly dependent on the injected water temperature and the distance from the injection well. A small temperature change appeared on the surface compared to other simulated temperature distributions of 30 and 50 m depths. The porosity and groundwater flow characteristics of each layer sensitively affected the heat transfer. The groundwater levels and temperature changes in injection and pumping wells were monitored and the thermal interference between the wells was analyzed to test the effectiveness of the heat pump operation method applied.

Experimental Study on Electrokinetic Streaming Potential in Micropore Channels of Hollw-Fiber Based on General Helmholtz-Smoluchowski's Principle (일반적 Helmholtz-Smoluchowski 원리에 따른 중공사 미세기공 채널에서의 계면동전기 흐름전위에 관한 실험연구)

  • 전명석;조홍일
    • Membrane Journal
    • /
    • v.12 no.1
    • /
    • pp.41-50
    • /
    • 2002
  • The streaming potential generated by the electrokinetic flow within electric double layer of charged microchannel is applied to determine the zeta potential of hollow-fiber membrane pore by using the general Helmholtz-Smoluchowski equation. The streaming potential is know to provide a useful real-time information on the surface property and the interaction between pore and particles in actual situations and physicochemical conditions. The influence of physicochemical parameters upon the filtration with hollow-fibers has been examined with an in-situ and simultaneously monitoring the streaming potential as well as permeate flux. In particular, the present study examined an experimental method to identify the effect of cake layer which can vary according to the axial position of a hollow-fiber and the progress of membrane fouling by measuring the position-dependent streaming potential. As the latex concentration increases, the permeate flux decreased but the streaming potential increased. The growth of cake layer has been mire developed with increasing latex concentration, however, the effect of surface charges of latexes deposited on the membrane surface leads to increase the streaming potential. With increasing ionic concentration of KCI, both the permeate flux and the streaming potential decrease. The increase of ionic concentration provides a compact cake layer due to the shrinkage of Debye length and the decreased streaming potential results from the weakened ionic flows owing to a thin diffusive double layer.

Performance Assessment and Design Evaluation of Bioretention Planter Boxes Treating Urban Stormwater Runoff (도심지역 강우유출수 처리목적 식물재배화분의 성능 및 설계인자 분석)

  • Guerra, Heidi B.;Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.72-79
    • /
    • 2018
  • Two planter boxes were monitored during their initial year of operation to be able to assess their stormwater runoff and pollutant reduction capabilities and investigate on the design factors affecting their performance. One of the planter boxes provided 85-100% runoff volume reduction for rainfall less than 15 mm and rainfall intensities lower than 5 mm/hr. This reduced to 50-64% during higher rainfall intensities and depths of up to 50 mm. Suspended solids, organics, nutrients, and heavy metals were satisfactorily removed at a range of 40-95%. The other planter box, however, did not produce outflow in all the events and allowed total capture of stormwater. The uncertainty regarding the fate of the runoff in that case required an investigation of the planter box's actual drainage and underground conditions which was deemed outside the scope of the study. Nonetheless, several design improvements and retrofits were suggested based on the provisions of current design guidelines to ensure that the hydraulic and water quality goals are achieved without potential damage to nearby structures. Moreover, continuous monitoring data is required to provide more accurate design evaluation and can serve as a guide in the construction of similar facilities in the future.

Analysis of Antimicrobial Resistance Pattern and Distribution of Multi-drug Efflux Pump Genes and Virulence Genes in Enterococcus faecalis Isolated from Retail Meat in Seoul (서울시내 시판 식육에서 분리한 Enterococcus faecalis의 항생제 내성 유형, 다중약물 유출 펌프 유전자 및 병독성 유전자의 분포도 분석)

  • Choi, MinKyung;Choi, SungSook
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.135-140
    • /
    • 2017
  • The aim of this study was to investigate the distribution of genes that encode multi-drug efflux pumps and virulence factors in Enterococcus faecalis isolated from retail meat and antibiotic resistance patterns of these strains. Of the 277 retail meat samples, 93 Enterococcus faecalis were isolated. The strains exhibited resistance to ampicillin (35.5%), chloramphenicol (6.4%), ciprofloxacin (4.3%), erythromycin (18.3%), levofloxacin (0%), quinupristin-dalfopristin (76.3%), tetracycline (45.2%), teicoplanin (0%) and vancomycin (0%). The strains were positive for MFS type eme(A) (100%), ABC type efr(A) (100%), ABC type efr(B) (98.9%) and ABC type lsa (91.4%) efflux pump gene. The strains were positive for gelE (68.8%), ace (90.3%), asa1 (47.3%), efaA (91.4%) and esp (12.9%) virulence gene. This research will help to assess the hazards associated with the occurrence of drug resistance among enterococci from retail meat. Therefore, it is necessary to monitor enterococcus spp. isolated from retail meat continuously.

Analysis of Hydraulic Gradient at Coastal Aquifers in Eastern Part of Jeju Island (제주도 동부지역 해안대수층의 조석에 의한 수리경사 변화 연구)

  • Kim, Kue-Young;Shim, Byoung-Ohan;Park, Ki-Hwa;Kim, Tae-Hee;Seong, Hyeon-Jeong;Park, Yun-Seok;Koh, Gi-Won;Woo, Nam-Chil
    • Economic and Environmental Geology
    • /
    • v.38 no.1
    • /
    • pp.79-89
    • /
    • 2005
  • Groundwater level changes in coastal aquifers occur due to oceanic tides, where the properties of oceanic tides can be applied to estimate hyadraulic parameters. Hydraulic parameters of coastal aquifers located in eastern part of Jeju island were estimated using the tidal response technique. Groundwater level data from a saltwater intrusion monitoring well system was used which showed tidal effects from 3 to 5 km. The hydraulic gradient was assessed by utilizing the filtering method from 71 consecutive hourly water-level observations. Calculated hydraulic diffusivity ranged from 2.94${\times}10^7m^2d^{-1}$ to 4.36${\times}10^7m^2d^{-1}$ . The hydraulic gradient of the coastal aquifer area was found to be ~$10^{-4}$, whereas the gradient of the area between wells Handong-1 and 2 was found to be ~$10^{-6}$, which is very low comparatively. Analysis of groundwater monitoring data showed that groundwater levels are periodically higher near coastal areas compared to that of inner land areas due to oceanic tide influences. When assessing groundwater flow direction in coastal aquifers it is important to consider tidal fluctuation.

Marine Environmental Characteristics around the Test Phase of Offshore Wind Farm in the Southwestern Coast of Yellow Sea (서남해 해상풍력 실증단지 해역의 해양 환경 특성)

  • Seo, Jinsung;Maeng, Junho;Lim, Eunpyo;Jin, Seungjoo;Kim, Hyunmin;Kim, Taeyun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.5
    • /
    • pp.457-470
    • /
    • 2019
  • This study aims to present the characteristics of marine physics, water quality, and sediment quality around offshore wind farm near the Gochang and Buan sea areas through the analysis of monitoring data. The relationships between suspended solid and wave height as well as suspended solid and flow velocity were analyzed. We found that Correlation Coefficient values of 0.61~0.69 between wave height and suspended solid, and suspended solid concentration reaches 75 mg/L or higher when wave height of more than 1m occurred in the spring (1 month). The water quality index (WQI) was used to identify the status of the water quality in the study area. Most of the measured points were rated first grade (very good). The variation of chlorophyll-a was relatively hight compared to the other criteria, indicating that it is a major factor affecting the quality index. In the sediment column, all heavy metals were detected below the Threshold Effects Level(TEL), and ignition loss and grain size show a positive correlation.

Assessment of Water Circulation and Hydro-characteristics with LID techniques in urbanized areas (도시지역에 적용된 LID 기법의 강우시 수문특성 및 물순환 평가)

  • Choi, Hyeseon;Hong, Jungsun;Jeon, Minsu;Geronimo, Franz Kevin;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.191-198
    • /
    • 2019
  • High impervious surfaces increase the surface runoff during rainfall and reduces the underground infiltration thereby leading to water cycle distortion. The distortion of water cycle causes various urban environmental problems such as urban flooding, drought, water pollutant due to non-point pollution runoff, and water ecosystem damage. Climate change intensified seasonal biases in urban rainfall and affected urban microclimate, thereby increasing the intensity and frequency of urban floods and droughts. Low impact development(LID) technology has been applied to various purposes as a technique to reduce urban environmental problems caused by water by restoring the natural water cycle in the city. This study evaluated the contribution of hydrologic characteristics and water cycle recovery after LID application using long-term monitoring results of various LID technology applied in urban areas. Based on the results, the high retention and infiltration rate of the LID facility was found to contribute significantly to peak flow reduction and runoff delay during rainfall. The average runoff reduction effect was more than 60% at the LID facility. The surface area of the LID facility area ratio(SA/CA) was evaluated as an important factor affecting peak flow reduction and runoff delay effect.