• Title/Summary/Keyword: 명중률

Search Result 149, Processing Time 0.029 seconds

Statue of Intestinal Parasitic Infections in a Remote Island, Yondo, Jeonranarn-do (Province) (전라남도 여천군 남면 연도 주민의 장내 기생충 감염상황)

  • 구기수;민득영
    • Parasites, Hosts and Diseases
    • /
    • v.26 no.4
    • /
    • pp.275-284
    • /
    • 1988
  • This study was performed to observe the present status of intestinal parasitic infections in a remote island, Yondo, located in southern part of Jeonranam-do (Province) , Korea. In February and May, 1988, total 1,011 individual stool samples were collected and examined for intestinal helminths and protozoa using formalin-ether centrifugal sedimentation technique. The results are summarized as follows: 1. Of 1,011 inhabitants examined, 398(39.4%) were positive for intestinal parasites. Helminth positives were 372(36.8%) , and protozoan cyst positives were 56(5.5%) . 2. Ten species of parasites were found. Trichuris trichiura revealed the highest infection rate of 27.5%, Ascaris lumbricoides 17.4%, Taenia sp. 5.8%, Entamoeba coli 3.3%, Ciardia Zamblia 1.5%, Endelimax nasa 0.8%, Hymenolepis nana 0.4%, Hookworm 0.2%, Trichostrongylus orientalis 0,2%, and Entamoeba histolytica 0.2%, respectively. 3. The female group showed higher positive rate(44.0%) than males (34.7%). Also, higher positive rates were observed among adults as compared with the group younger than 10 years old. 4. Average value of E.P.G. was 1,876(range 200∼17,800) in A. lumbricoides positives, and 327 (range 200∼1,600) in T. trichiura positive cases. 5. In helminth egg Positive cases, single in(traction was 63.4%, double infection 34.7%, and triple infection 1.9%, respectively. Among protozoan cyst positives, single infection was 94.6%, and double infection was 5.4%. The present study revealed that the prevalence of intestinal parasites among inhabitants in Yondo island is still so high that special control measures should be performed.

  • PDF

Comparison of X-ray VCUG with RI VCUG for Diagnosing VUR in Children (소아의 방광 요관 역류 진단시 X-ray 배뇨성 방광 요도 조영술(X-ray VCUG)과 방사성 동위원소 배뇨성 방광 요도 조영술(RI VCUG)의 비교)

  • Hong Hyun-Soook;Choi Deuk-Lin;Kim Eun-Mi;Kim Sung-Jun
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.187-195
    • /
    • 1999
  • Purpose : VUR is state where urine regurge from bladder to ureter and kidney. It is shown in about 1/3 of urinary tract infection patients and it is classified as grade I to V. We compared results from RI VCUG(Radiisotope voiding cystourethrography) and X-ray VCUG which used in diagnosing VUR in children, to evaluate which is better in diagnosing VUR in children. Methods : 41 Patients(19 males, 21 females), who visited Pediatric department, Soonchunhyang university Hospital from peroid of 1991. January to 1998. July for recurrent urinary tract infection or abnormalities in ultrasonogams, were enrolled in the study. The age ranged from 9 months to 17 years and mean age was 5 1/2 years. Both RI VCUG and X-ray VCUG were done and follow-up test of urine culture, renal ultrasonogram and RI VCUG were done every month, every 3 month and every 6 month, respectively to observe the disappearance of VUR and evaluated the prognosis. Results : 24 patients had taken RI VCUG and 17(70.1%) patients showed positive result. 22 patients had taken X-ray VCUG and 9(40.1%) patients showed findings of VUR. 17 patients had taken both tests and 14 patients showed positive result in RI VCUG and 6 of these patients also showed reflux in X-ray VCUG. 3 patients who showed negative in RI VCUG, showed negative also in X-ray VCUG. For prognosis, resolution and scar formation was shown in 8 patients each. Persistent VUR was shown in 6 patients and 2 of these patients VUR was corrected by operation, 1 patient showed decreased renal function, and 1 patient was not follwed up. 8 of 9 patients who showed findings of VUR on DMSA scan formed a scar and 8 patients who showed no findings of VUR didn't form a scar. Urine culture was positive in 17 of 19 patients with VUR. Positive rate in urine culture was higher than that of patients with no VUR who showed positivity in 15 of 21 patients for urine culture. E. coli was most common organism and the period free of UTI was 14 months in VUR patients and it was shorter compared to patients without VUR which was 26 months. Conclusion : In diagnosing VUR in children, the positive rate was higher in RI VCUG than X-ray VCUG. Therefore, in early diagnosis when VUR is suspicious but not shown in X-ray VCUG, RI VCUG should be done and it will help to make accurate diagnosis.

  • PDF

Study on Pulse Separation Device of Bulkhead Type for Solid Rocket Motors (고체 추진기관의 격벽형 펄스분리장치 연구)

  • Cho, Won-Man;Kim, Won-Hoon;Chang, Hong-Been;Oh, Jong-Yun;Lee, Bang-Eop;Lee, Jong-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.187-190
    • /
    • 2009
  • A multiple pulse rocket motor distributes the thrust energy more effectively compared to typical rocket motor as providing subsequent thrusts by the pulse motors of the missile. The pulse rocket motor is the advanced technology to improve an end game capability of the missile by increasing the range and final velocity. A pulse separation device is the core part of the pulse motor. The pulse separation device of bulkhead type was designed and developed. The elastic-plastic structural analysis of the bulkhead and rupture disc was conducted. Several air tests were also conducted to confirm the structural safety and acceptability about the design concept. Test results were compared with the analysis results, which showed reasonable agreements.

  • PDF

A Study on the Transmitter Design for Transmitting Output Power Enhancement of Active Magnetic Sensor (능동형 자기센서의 송신출력 향상을 위한 송신기 설계에 관한 연구)

  • Chung, Hyun-Ju;Yang, Chang-Seob;Jeon, Jae-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.5
    • /
    • pp.159-165
    • /
    • 2013
  • A active magnetic sensor has been widely used in the underwater guided weapon system because it is able to detect a target accurately in close range, but the target doesn't have any good countermeasure to overcome the threat from the active magnetic sensor. Recently, in order to increase the damage area of target by shock wave with explosion of the underwater weapon system and to detect small target, the maximum target detection range of the active magnetic sensor needs to be increased. One method for improving maximum target detection range is to improve output power from transmitter through demagnetization factor minimization of a transmitting core. Thus, in this paper, we describe the study results on the transmitter core shape design to enhance output power of the active magnetic sensor.

Study of Integrated-Flight M&S Application for the Anti-Tank Missile Configuration Design (대전차 유도무기의 형상 설계에서의 통합비행 M&S 적용 연구)

  • Jeong, Dong Gil;Kim, Sangman;Lee, Gunha;Hwang, Cheol Gyu
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • 6-DOF flight simulation program is most generally used M&S tool in domestic missile development procedure. The 6-DOF M&S method, however, cannot validate the performance of a imaging seeker-adopted missile in various conditions. A M&S tool for the analysis of the integrated-flight simulation is required since the tracking performance of the imaging seeker is highly dependent on the missile maneuvering, which introduces the displacement and rotation of the target in the seeker imagery. Through the development of the $3^{rd}$ generation anti-tank missile, Raybolt, the integrated-flight M&S tool was developed and applied to the missile configuration design. It integrates synthetic image generation S/W, imaging tracker, and flight simulation program and computes the main system performance criteria, hit probability by Monte-Carlo Simulation. In this paper, the issues in the $3^{rd}$ generation anti-tank missile configuration and the integrated-flight M&S method and results are described.

Target Recognition Algorithm Based on a Scanned Image on a Millimeter-Wave(Ka-Band) Multi-Mode Seeker (스캔 영상 기반의 밀리미터파(Ka 밴드) 복합모드 탐색기 표적인식 알고리즘 연구)

  • Roh, Kyung A;Jung, Jun Young;Song, Sung Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.177-180
    • /
    • 2019
  • To improve the accuracy rate of guided weapons, many studies have been conducted on the accurate detection and identification of targets from sea clutter. Because of the variety and complicated characteristics of both sea-clutter and target signals, an active target recognition technique is required. In this study, we propose an algorithm to distinguish clutter and recognize targets by applying a fractal signature(FS) classifier, which is a fractal dimension, and a high-resolution target image(HRTI) classifier, which applies scene matching to an image formed from a scanned image. Simulation results using the algorithm revealed that the HRTI classifier recognized targets 1 and 2 at a 100 % rate, whereas the FS classifier recognized targets 1 and 2 at rates of 90 % and 93 %, respectively.

Novel Two Stage AC-to-DC Converter with Single Switched Zero Voltage Transition Boost Pre-Regulator using DC-Linked Energy Feedback (새로운 영전압 스위칭 이단방식의 고역률 컨버터)

  • Roh, Chung-Wook;Moon, Gun-Woo;Jung, Young-Seok;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.385-387
    • /
    • 1996
  • A novel two stage soft-switching ac-to-dc convener with power factor correction is proposed. The proposed convener provides zero-voltage-switching (ZVS) condition to main switch of boost pre-regulator without auxiliary switch. Comparing to the conventional two stage approach(ZVS-PWM boost rectifier followed by off-line ZVS dc-dc step down converter), the proposed approach is simple and reducing EMI noise problem. A new simple DC-linked energy feedback circuit provides zero-voltage-switching condition to boost pre-regulator without imposing additional voltage and current stresses and loss of PWM capability. Operational principle, analysis, control of the proposed converter together with the simulation results of 1KW prototype are presented.

  • PDF

A New Single Stage AC/DC Converter with High Power Factor and High Efficiency (고역률과 고효율을 갖는 새로운 단일 전력단 AC/DC 컨버터)

  • Lee, Jun-Young;Moon, Gun-Woo;Jung, Young-Suk;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.582-584
    • /
    • 1996
  • A new single stage AC/DC converter with a high power factor is proposed. The proposed converter gives good power factor correction, low current harmonic distortions, and tight output regulations. This converter also has an high efficiency by employing Active-clamp method and synchronous rectifiers. To verify performances of the proposed converter, 90W-converter is designed. This prototype meets the IEC555-2 requirements satisfactorily with nearly unity power factor.

  • PDF

Novel Reset Winding Clamped Forward Converter with Transformer Voltage Feedback Technique for Power Factor Correction (변압기 전압 되먹임방식을 이용한 고역률의 리셋권선을 갖는 새로운 포워드 컨버터)

  • Moon, Gun-Woo;Roh, Chung-Wook;Jung, Young-Seok;Lee, Jun-Young;Youn, Myung-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.348-350
    • /
    • 1996
  • A new reset winding clamped forward converter with transformer voltage feedback technique for power factor correction with a single-switch/single-stage is proposed. The proposed converter gives the good power factor correction, low current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC555-2 requirements are met satisfactorily with nearly unity power factor.

  • PDF

High Power Factor High Efficiency PFC AC/DC Converter for LCD Monitor Adapter (LCD 모니터의 어댑터를 위한 고역률 고효율 PFC AC/DC 컨버터)

  • Park K. H.;Kim C. E.;Youn M. J.;Moon G. W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.85-89
    • /
    • 2003
  • Many single-stage PFC(power-facto.-correction) ACHC converters suffer from the high link voltage at high input voltage and light load condition. In this paper, to suppress the link voltage, a novel high power factor high efficiency PFC AC/DC converter is proposed using the single controller which generates two gate signals so that one of them is used far gate signal of the flyback DC/DC converter switch and the other is applied to the Boost PFC stage. A 130w prototype for LCD monitor adapter with universal input $(90-265V_{rms})$ and 19.5V 6.7A output is implemented to verify the operational principles and performances. The experimental results show that the maximum link voltage stress is about 450V at 270Vac input voltage. Moreover, efficiency and power factor are over $84\%$ and 0.95, respectively, under the full load condition.

  • PDF