• Title/Summary/Keyword: 멸균방법

Search Result 150, Processing Time 0.025 seconds

INFECTION CONTROL OF LIGHT CURING UNITS (광중합기 사용 시의 감염 조절)

  • Chang, Hoon-Sang
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.235-237
    • /
    • 2010
  • When curing the composite restorations with light curing units, the light guides are often in direct contact with oral tissues, therefore contamination of light guides is inevitable. Curing light guides fall into the "semicritical" instrument category according to the Centers for Disease Control and Prevention (CDC) and must be heat or vapor-sterilized or at a minimum, these semicritical instruments must be sterilized in a liquid chemical agent. Currently, most common methods of maintaining sterility of the light guides are wiping the guide with a disinfectant, such as glutaraldehyde, after each patient use; using autoclavable guides; using presterilized, single-use plastic guides; and using translucent disposable barriers to cover the guide.

Effect of Gamma-Irradiation Sterilization on the Creep and Wear of Ultra-High Molecular Weight Polyethylene (감마선 멸균처리가 초고분자량 폴리에틸렌의 크리프와 마모에 미치는 영향)

  • Lee, Kwon-Yong;Lee, Soo-Cheol;Lee, Keun-Ho
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.1-6
    • /
    • 1998
  • 인공관절 라이너에 널리 사용되는 대표적 생체재료인 초고분자량 폴리에틸렌(Ultra-High Molecular Weight Polyethylene)은 체내에 삽입되기 전에 멸균처리를 거쳐야 하며, 가장 보편적인 멸균방법은 감마선을 이용한 멸균처리이다. 그러나, 감마선은 폴리에틸렌의 화학분자 결합구조에 변화를 일으키며, 따라서 물리적, 기계적 물성치에 변화를 야기시킨다. 이는 인공관절 수명을 좌우하는 변형과 마모현상에도 결정적 영향을 줄 것으로 사려된다. 본 연구에서는 감마선 멸균처리가 UHMWPE의 크리프 변형 및 마모에 미치는 영향이 관찰되었고, 그 결과들은 감마선 멸균처리로 야기된 폴리에틸렌의 화학분자 결합구조의 변화(Crystallinity, Oxidation, Crosslinking)와 함께 분석되었다. 압축 제작된 초고분자량 폴리에틸렌 봉(extruded UHMWPE rod)으로부터 원통형의 시평을 제작하여 감마선 멸균처리를 행하고, 압축 크리프 실험과 마모 실험을 실시하여 멸균처리하지 않은 시편을 제작하여 감마선 멸균처리를 행하고, 압축 크리프 실험과 마모 실험을 실시하여 멸균처리하지 않은 시편 사이에는 크리프 복원정도를 제외하고 거의 차이가 없었으나, 반면에 마모의 경우, 감마선 멸균처리된 시편이 멸균처리하지 않은 시편보다 훨씬 적은 마모량을 보였다(p〈0.05). 이것은 crosslinking 증가에 따른 마모 저항력 향상으로 볼 수 있다.

Gamma-irradiated ultra-high molecular weight polyethylene (감마선 멸균처리된 초고분자량 폴리에틸렌)

  • ;;Lee, Keun-Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.227-233
    • /
    • 1998
  • 인공관절 라이너에 널리 사용되는 대표적 생체재료인 초고분자량 폴리에틸렌 (Ultra-High Molecular Weight Polyethylene)은 체내에 삽입되기 전에 멸균처리를 거쳐야 하며, 가장 보편적인 멸균 방법은 감마선을 이용한 멸균처리이다. 그러나, 감마선은 폴리에틸렌의 화학분자 결합구조에 변화를 일으키며, 따라서 물리적, 기계적 물성치에 변화를 야기 사려된다. 이는 인공관절 수명을 좌우하는 변형과 마모현상에도 결정적 영향을 줄 것으로 사려된다. 본 연구에서는 감마선 멸균처리가 UHMWPE의 크리프 변형 및 마모에 미치는 영향이 관찰되었고, 그 결과들은 감마선 멸균처리로 야기된 폴리에틸렌의 화학분자 결합구조의 변화(Crystallinity, Oxidation, Crosslinking)와 함께 분석되었다. 압출 제작된 초고분자량 폴리에틸렌 봉(extruded UHMWPE rod)으로부터 원통형의 시편을 제작하여 감마선 멸균처리를 행하고, 압축 크리프 실험과 마모 실험을 실시하여 멸균처리 하지 않은 시편의 결과와 비교하였다. 크리프 변형의 경우, 감마선 멸균처리 된 시편과 멸균처리 하지 않는 시편 사이에는 크리프 복원정도를 제외하고 거의 차이가 없었으나, 반면에 마모의 경우, 감마선 멸균처리 된 시편이 멸균처리 하지 않은 시편보다 훨씬 적은 마모량을 보였다 (p<0.05). 이것은 crosslinking 증가에 따른 마모 저항력 향상으로 볼 수 있다.

  • PDF

A COMPARATIVE STUDY ON THE PHYSICAL PROPERTIES OF ORTHODONTIC PLIERS ACCORDING TO TYPES OF STERILIZATION (멸균 방법에 따른 교정용 플라이어의 물성 변화에 대한 비교 연구)

  • Cho, Il-Je;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.329-341
    • /
    • 1998
  • Sterilization has received much attention in orthodontic practices over the past several years. The present study was undertaken to investigate the effects of sterilization on the physical properties of orthodontic pliers-AEZ, Unitek, and Dentronix ligature cutters. This study was designed to examine the tips of ligature cutters before and after 200 and 400 sterilization cycles using the Bowmar RHT-1000, the Dentronix DDS-5000, and the Eschmann SES-2000. The tip surface and the fracture surface were observed with a scanning electron microscope. The microstructure was observed with an optical microscope. The hardness test was carried out with the mic개-Vickers hardness tester and the Rockwell C Scale hardness tester. The chemical composition was analyzed by energy dispersive X-ray spectrometer. The results of this study were as follows : 1. The number and the size of corrosion products on the tip surface and the proportion of cleavage planes in fractured specimen increased, but the hardness of the tip decreased in proportion to sterilization cycles. From these observations, it was considered that mechanical properities decreased in proportion to sterilization cycles. 2. The number and the size of chromium carbides increased in proportion to sterilization cycles. Coarse microstructure decreased mechanical properities. 3. The AEZ and Unitek ligature cutters were Fe-Cr stainless steels, but the Dentronix ligature cutter was Co-Cr alloy. There were many differences among manufactures, but the chemical composition was .not changed after sterilization cycles. 4. The tip edge of ligature cutter used in a clinic revealed microcracks with the SEM observation. Clinical experience confirmed that ligature cutters were gradually degraded by sterilization.

  • PDF

Study on the Infection Control and Dental waste Disposal in Dental Clinic Located in Seoul City (서울시 치과의원의 진료실 감염관리 및 폐기물 처리 실태 조사연구)

  • Kang, Jae-Kyoung;Kim, Eun-Sook;Kim, Kyung-Mi
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.105-113
    • /
    • 2002
  • This study was aimed to investigate the practice on the infection control and dental waste disposal in dental clinic. The data used in this study had been collected in 100 dental clinics located in Seoul city from August to October, 2001. It was shown that examination instruments, oral surgery instruments, and periodontal instruments were almost sterilization in dental clinic. It was high in the recognition of individual protection but it was low in the degree of practice. Therefore, the practice in infection control is very important to dental team for safety of patients and operators.

  • PDF

THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES (차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구)

  • Yang, Won-Kyung;Ra, Yoon-Sik;Lee , Young-Kyoo;Son, Ho-Hyun;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.121-127
    • /
    • 2005
  • A variety files made of stainless steel (S-S) or nickel-titanium (Ni-Ti) are used during endodontic treatment. The purpose of tt)is study was to evaluate the corrosion susceptibility of S-S and Ni-Ti endodontic files. Three brands of files were used for this study: $K-flex^{(R)}$ S-S files (Maillefer, USA), $Profile^{(R)}$ Ni-Ti files (Maillefer, USA), $K-3^{(R)}$ Ni-Ti files (SybronEndo. USA). 120 files of each brands (21mm, ISO size $\#20$) were divided into 12 groups according to 1) sterilization methods using Autoclave or Ethylene Oxide (E-O) gas, 2) Irrigation solutions using $5.25\%$ NaOCl or Saline, 3) the number of sterilization (1, 5, 10 times), After above procedures, each of the files was inspected by three examiners with a light microscope and camera at X25. Each file was judged and ranked according to the following criteria: 0;, no corrosion, 1; mild corrosion, 2; moderate corrosion, and 3; severe corrosion. The files of high score were examined under the Scanning Electron Microscope. Data were statistically analyzed with the Kruskal-Wallis test (p < 0.05). Most of the ten time-autoclaved files had showed mild to moderate corrosion. But, one or five time-autoclaved files did not show corrosive surface. NaOCl treatment and E-O gas sterilization did not influence on corrosion. There was a significant difference in corrosion susceptibility between sterilization methods and the number of autoclaving. However, there was no significant difference between brands and file materials.

Significant Attenuation of Aden-associate Virus Gene Expression by Catechol-conjugated Heparin Surface Coating (카테콜기가 도입된 헤파린의 표면고정화에 의한 아데노연관바이러스의 발현 억제에 관한 연구)

  • Do, Minjae;Lee, Slgirim;Jang, Jae-Hyung;Lee, Haeshin
    • Journal of Adhesion and Interface
    • /
    • v.17 no.4
    • /
    • pp.149-154
    • /
    • 2016
  • In this study, natural polymer-based virus neutralizing agent was developed in an attempt to replace the conventional sterilization method for mammalian cell culture. A catechol conjugated heparin was synthesized by using EDC chemistry, and it show unique binding ability to virus which has heparin affinity (adenovirus, adeno-associated virus). To evaluate neutralization ability of catechol conjugated heparin, adeno-associated virus was used for test model, instead of using a pathogenic virus. The catechol conjugated heparin exhibited resistance to high concentration of salt and complete inactivation of adeno-associated virus. The result suggests that the catechol conjugated heparin, which is biocompatible and efficiency, may replace conventional sterilization method for mammalian cell culture.

A Study on Characteristics of Incinerator for Medical Wastes (감염성 폐기물 처리용 소각로 특성에 대한 연구)

  • 채호준;조석연;박용한;장필수
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.471-472
    • /
    • 2003
  • 국민의 보건의식이 높아짐에 따라서, 병원에서 배출되는 감염성 폐기물의 안정적 처리에 대한 요구가 높아지고 있다. 감염성 폐기물 처리방법으로는 가압멸균과 산화소각 및 건류소각이 있는데, 본 연구 목적은 100%멸균이 보장되는 중형 산화소각을 설계하고 이의 운영특성을 파악하는데 있다. 감염성 폐기물은 일정규격의 상자에 담아서 배출되며, 저온에서 이송과 저장이 이루어지며, 소각로 투입시에도 상자를 파손하지 않고 투입되어야 하는 등의 엄격한 규정에 따라서 소각하여야 한다. 본 연구는 이러한 감염성 폐기물처리 법규 및 감염성 폐기물의 연소 특성을 파악하여 소각로 설계의 기본자료로 활용하였다. (중략)

  • PDF

ARC-NUCLEART연구소의 보존, 복원, 멸균작업

  • Duchene, Jacques
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.31-40
    • /
    • 2002
  • 1. 프랑스의 문화재보존과 복원 연구소 조직 현황소개 2. ARC-NUCLEART연구소 소개-연구소에서 문화재 보존을 위해서 사용 기술소개 - 지상과 해양의 고고학 발굴시 젖은 목재와 가죽작품 건조작업, 강화작 업, 보수작업 수행 -목재문화재 (조각상, 가구, 사적 바닥마루), 멸균 및 강화처리 - 가죽문화재의 복원 3. 연구소 시설 4. 화재 자질의 파손상태파악과 고고학가치의 목재와 가죽작품 보존 방법에 대한 연구 수행 5. ARC-NUCLEART에서 보존, 복원하는 문화재의 처리 용례 아크 뉘클레아르(ARC Nucleart)의 감마선조사기 설치

  • PDF